首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
本文概述了7种以高分子为膜材料、用于混合液体分离的膜分离过程,即离子交换膜与电渗析、反渗透、超滤、微孔过滤、膜萃取、渗透汽化和膜蒸馏。对其原理、高分子膜材料、应用和发展趋向作了简要介绍;并阐述了我国膜分离发展的现状和展望。  相似文献   

2.
The most important factor in the electrodialysis (ED) process is the permselectivity of the ion exchange membranes, which permit not only the separation of cations and anions in a solution, but also the separation of ions with the same sign but different valences. In this work, the mechanism of the permselectivity has been studied through the measurement of the potentials at different planes of the membrane. The experimental results have shown that there was a secondary potential inside ion exchange membranes in an electrodialysis process. At the membrane side touched with dilute solution, this secondary potential enhanced the external electrical field, and thus speeded up the passage of the corresponding ions in the dilute solution through the membranes; at the membrane side touched with concentrated solution, the secondary potential was contrary to the external electrical field and thus counteracted it, which could be very helpful by preventing the ions in the concentrated solution from entering the membranes. Obviously, the existence of the secondary potential might play an important role in the permselectivity of ion exchange membranes in ED processes.  相似文献   

3.
The off-line coupling of an isoelectric trapping device termed membrane separated wells for isoelectric focusing and trapping (MSWIFT) to mass spectrometry-based proteomic studies is described. The MSWIFT is a high capacity, high-throughput, mass spectrometry-compatible isoelectric trapping device that provides isoelectric point (pI)-based separations of complex mixtures of peptides. In MSWIFT, separation and analyte trapping are achieved by migrating the peptide ions through membranes having fixed pH values until the peptide pI is bracketed by the pH values of adjacent membranes. The pH values of the membranes can be tuned, thus affording a high degree of experimental flexibility. Specific advantages of using MSWIFT for sample prefractionation include: (1) small sample volumes (~200 μL), (2) customized membranes over a large pH range, (3) flexibility in the number of desired fractions, (4) membrane compatibility with a variety of solvents systems, and (5) resulting fractions do not require sample cleanup before MS analysis. Here, we demonstrate the utility of MSWIFT for mass spectrometry-based detection of peptides in improving dynamic range and the reduction of ion suppression effects for high-throughput separations of tryptic peptides.  相似文献   

4.
The conversion of sodium lactate to lactic acid with water-splitting electrodialysis was investigated. One way of reducing the power consumption is to add a conductive layer to the acid compartment. Doing this reduced the power consumption by almost 50% in a two-compartment cell, whereas the electric current efficiency was not affected at all. Three different solutions were treated in the electrodialysis unit: a model solution with 70 g/L of sodium lactate and a fermentation broth that had been prefiltered two different ways. The fermentation broth was either filtered in an open ultrafiltration membrane (cut-off of 100,000 Dalton) in order to remove the microorganisms or first filtered in the open ultrafiltration membrane and then in an ultrafiltration membrane with a cut-off of 2000 Dalton to remove most of the proteins. The concentration of sodium lactate in the fermentation broth was 70 g/L, as well. Organic molecules present in the broth (peptides and similar organic material) fouled the membranes and, therefore, increased power consumption. Power consumption increased more when permeate from the more open ultrafiltration membrane was treated in the electrodialysis unit than when permeate from the membrane with the lower cut-off was treated, since there was a higher amount of foulants in the former permeate. However, the electrodialysis membranes could be cleaned efficiently with a 0.1 M sodium hydroxide solution.  相似文献   

5.
In the present study, we evaluated for the first time the photoprotective effect of fish bone bioactive peptides (FBBP) preparation isolated from silver carp (Hypophthalmichthys molitrix) discarded tissue using in vitro experimental models of skin cells exposed to ultraviolet B (UVB) irradiation and stressing agents. FBBP preparation was obtained by papain treatment of minced bones and centrifugal ultrafiltration, and the molecular weight (MW) distribution was characterized by size exclusion and reversed-phase high performance liquid chromatography (RP-HPLC). In vitro assessment of the effect of FBBP pretreatment in UVB-irradiated L929 fibroblasts and HaCaT keratinocytes revealed their cytoprotective activity. Their capacity to efficiently reduce reactive oxygen species (ROS) production and lipid peroxidation varied in a dose-dependent manner, and it was greater in fibroblasts. A decrease of proinflammatory cytokines secretion, in particular of tumor necrosis factor alpha (TNF-α), was found after FBBP pretreatment of THP-1-derived inflamed macrophages. Melanin production and tyrosinase activity investigated in UVB-irradiated Mel-Juso cells were lowered in direct relation to FBBP concentrations. FBBP fractions with high radical scavenging activity were separated by ion exchange chromatography, and two collagenic sequences were identified. All these results offer new scientific data on aquaculture fish bone-derived peptides confirming their ability to control the antioxidant, anti-inflammatory and pigmentation processes developed during UV irradiation of skin cells and recommend their use as valuable natural ingredients of photoprotective cosmeceutical products.  相似文献   

6.
Application of Micellar enhanced ultrafiltration (MEUF) for the removal of different heavy metals has been reviewed. It is considered an economical alternative available to the conventional membrane separation process, because it reduces the requirement of higher pressure and high membrane costs. MEUF is a separation processes which uses surfactants and ultrafiltration membranes to remove multivalent ions from wastewater with high percent rejection using electrostatic attraction between metals and micelles.  相似文献   

7.
Chemical cross-linking anion exchange series membranes were prepared from linear engineering plastics poly(2,6-dimethyl-1,4-phenylene oxide) (PPO) by conducting the processes of bromination and amination at both benzyl and aryl positions. Compared with the traditional technologies, the membrane route described in this paper has cancelled the chloromethylation process and thus, given up the use of chloromethyl methyl ether, which has been considered as a potential harmful toxicity material. The ion exchange capacity, water content, membrane potential and transport number of membranes were studied. The results show that the membrane properties are significantly affected by the bromination processes: benzyl-substitution will enhance the ion exchange capacity and water content, while the aryl-substitution will decrease the water content with approximately unchanged ion exchange capacity. By properly balancing them, a series of membranes can be obtained to comply with different industrial requirements, such as diffusional dialysis, electrodialysis, and water splitting processes.  相似文献   

8.
Plasmid DNA isoforms can be separated by both agarose gel electrophoresis and a variety of chromatographic methods, but both of these approaches have significant shortcomings in terms of scalability, throughput, and/or resolution. This study provides the first demonstration that the supercoiled, linear, and open-circular isoforms of plasmid DNA can be effectively separated based on differences in their elongational flexibility in the highly converging flow field that is established during membrane ultrafiltration. Data were obtained with plasmids from 3 to 17 kbp in size using commercially available cellulose ultrafiltration membranes with pores an order of magnitude smaller than the DNA root-mean-square radius of gyration. High-resolution separations were achieved by controlling the filtrate flux between the critical flux values required for transmission of the individual isoforms. The separation behavior in ultrafiltration was very different than that observed in size exclusion chromatography or agarose gel electrophoresis due to differences in the underlying separation mechanisms. The simplicity of the ultrafiltration process makes this approach attractive for a wide range of applications, including large-scale purification of plasmid DNA for gene therapy.  相似文献   

9.
Microfluidic electrocapture of peptides and proteins in an inert capillary with electric contacts via conductive membranes is useful for sample handling before mass spectrometry. The use of electrocapture has already been demonstrated for sample clean-up, pre-concentration, chemical modification and peptide separation, all without the need for supporting gels or chemical binding. This method allows multiple micro-reactions, extensive peptide separations and work with membrane proteins from detergent-solubilized samples. Until now, electrocapture has utilized MALDI mass spectrometry, but here we demonstrate that it can be interfaced with electrospray ionization and hence with on-line mass spectrometric analysis of peptides separated from protein digests. These applications combined with the present on-line approach show electrocapture to be a versatile technology with great potential.  相似文献   

10.
设计合成了具有2个活性序列的线性和环状多肽及具有单个活性序列的短链多肽, 研究了它们的杀菌活性、 细胞毒性及溶血性. 结果表明, 线性肽和环状肽的杀菌活性高于短链肽. 利用计算模拟的方法计算了多肽与细菌细胞膜中一种重要的成分磷脂酰甘油(DMPG)的结合能. 结果表明, 多肽-DMPG的结合能与多肽的杀菌活性具有较高的相关性, 线性和环状多肽与DMPG的结合能大于短链肽. 线性和环状多肽均含有2个活性序列, 可提供多个荷正电氨基酸与荷负电的磷脂结合, 结合能较大, 杀菌活性较强. 采用模拟生物膜对其中几条多肽的作用机理进行了初步研究. 结果表明, 该类多肽有可能使正常哺乳动物细胞的细胞膜产生孔洞; 而对于细菌细胞膜, 多肽并未在膜上产生明显孔洞, 而是引起了细菌细胞膜的聚集.  相似文献   

11.
在蛋白质组学研究中,多肽混合物的有效分离对蛋白质鉴定和蛋白质之间相互作用的研究起着决定性的影响。基于此,用反相液相色谱研究了在两个不同长度的色谱柱上分离多肽混合物时色谱柱长度与峰容量的关系,同时考察了梯度洗脱时间对峰容量和峰宽的影响。实验结果表明,色谱柱长度对峰容量有显著的影响,而延长梯度洗脱时间不仅可以增加峰容量,而且可以增加峰宽。这说明用毛细管液相色谱 串联质谱联用方法对多肽混合物进行分离鉴定时,采用较长的色谱柱和较长的梯度洗脱时间有利于对更多的多肽进行分析鉴定。  相似文献   

12.
Electrodialysis of Amino Acid Solutions with Bipolar Ion-Exchange Membranes   总被引:1,自引:0,他引:1  
Bipolar membranes intended for the generation of hydrogen and hydroxyl ions in order to convert bipolar ions of amino acid into cations or anions migrating through cation- or anion-exchange membranes under a gradient of electric potential applied to the electromembrane system are studied. The transport processes occurring in glycine and sucrose solutions under electrodialysis with bipolar and unipolar ion-exchange membranes are examined. The proposed method permits the separation of a mixture of amino acids and sugars.  相似文献   

13.
Caustic regeneration procedures are often used in chromatographic purification processes of peptides and proteins to remove irreversibly bound impurities from the stationary phase. Silica-based materials are the most commonly used materials in reversed phase chromatography of peptides. Their limited chemical stability at high pH can be, however, problematic when high pH column regeneration (i.e. cleaning in place) is required. The effect of cleaning in place on the surface chemistry of the stationary phase has been investigated using the Tanaka test. It has been shown that the high pH treatment does not significantly affect the hydrophobicity of the material, but it strongly increases its silanol activity. A representative peptide purification process has been used to investigate the impact of cleaning in place on the separation performance. It has been shown that the caustic regeneration increases the peptide retention at high pH (pH 6.5), due to the interactions between the peptide and the negatively charged silanol groups. These unwanted interactions reduce the separation performances by decreasing the selectivity between the late eluting impurities and the main peptide. However, it has been shown that the effect of the silanol groups on the peptide adsorption and on the separation performance can be minimized by carrying out the purification process at low pH (pH ∼ 2). In this case, the silanol groups are protonated and their electrostatic interactions with the positively charged analyte (i.e. peptides) are suppressed. In these conditions, the peptide adsorption and the impurity selectivity is not changing upon high pH column regeneration and the separation performance is not affected.  相似文献   

14.
Selectively targeting the membrane‐perturbing potential of peptides towards a distinct cellular phenotype allows one to target distinct populations of cells. We report the de novo design of a new class of peptide whose ability to perturb cellular membranes is coupled to an enzyme‐mediated shift in the folding potential of the peptide into its bioactive conformation. Cells rich in negatively charged surface components that also highly express alkaline phosphatase, for example many cancers, are susceptible to the action of the peptide. The unfolded, inactive peptide is dephosphorylated, shifting its conformational bias towards cell‐surface‐induced folding to form a facially amphiphilic membrane‐active conformer. The fate of the peptide can be further tuned by peptide concentration to affect either lytic or cell‐penetrating properties, which are useful for selective drug delivery. This is a new design strategy to afford peptides that are selective in their membrane‐perturbing activity.  相似文献   

15.
Oil/water separation membranes with different wettability towards water are attractive for their economic efficiency and convenience. The key factor for the separation process is the roughness‐enhanced wettability of membranes based on the intrinsic wetting threshold (IWT) of water, that is, the limitation of the wettability caused by hydrophobicity and hydrophilicity. However, the separation of organic liquids (OLs) remains a challenge. Herein, we manipulate the surface tensions of nanofibrous membranes to lie between the IWTs of the two OLs to be separated so that the nanofibrous membranes can be endowed with superlyophobicity and superlyophilicity for the two liquids, and thus lead to successful separation. Our investigations provide a general strategy to separate any immiscible liquids efficiently, and may lead to the development of membranes with a large capacity, high flux, and high selectivity for organic reactions or liquid extraction in chemical engineering.  相似文献   

16.
Biomaterials made from self-assembling, short peptides and peptide derivatives have great potential to generate powerful new therapies in regenerative medicine. The high signaling capacity and therapeutic efficacy of peptidic scaffolds has been established in several animal models, and the development of more complex, hierarchical structures based on peptide materials is underway. This highlight discusses several classes of self-assembling peptide-based materials, including peptide amphiphiles, Fmoc-peptides, self-complementary ionic peptides, hairpin peptides, and others. The self-assembly designs, bioactive signalling strategies, and cell signalling capabilities of these bioactive materials are reported. The future challenges of the field are also discussed, including short-term goals such as integration with biopolymers and traditional implants, and long term goals, such as immune system programming, subcellular targeting, and the development of highly integrated scaffold systems.  相似文献   

17.
In this study, methodology was developed for on-line and miniaturized enzymatic digestion with liquid chromatographic (LC) separation and mass spectrometric (MS) detection. A packed capillary LC-MS system was combined with on-line trypsin cleavage of a model protein, lactate dehydrogenase, to provide an efficient system for peptide mapping. The protein was injected onto an enzymatic capillary reactor and the resulting peptides were efficiently trapped on a capillary trapping column. Different trapping columns were evaluated to achieve a high binding capacity for the peptides generated in the enzyme reactor. The peptides were further eluted from the pre-column and separated on an analytical capillary column by a buffer more suitable for the following an electrospray ionisation (ESI) MS process. An important aspect of the on-line approach was the desalting of peptides performed in the trapping column to avoid detrimental signal suppression in the ESI process. The developed on-line system was finally compared to a classical digestion in solution, with reference to peptide sequence coverage and sensitivity. It was shown that the on-line system gave more than 100% higher peptide sequence coverage than traditional digestion methods.  相似文献   

18.
A simple and efficient method based on ultrafiltration with liquid chromatography and mass spectrometry was used for the rapid screening and identification of ligands in the extracts of Stellera chamaejasme. The bound ligands, i.e. daphnoretin, isopimpinellin, chamaechromone, neochamaejasmin A, and chamaejasmine (purity of 96.8, 90.75, 91.41, 93.98, and 98.91%, respectively), were separated by semi‐preparative high‐performance liquid chromatography combined with high‐speed counter‐current chromatography. To the best of our knowledge, this is the first study to report the detection of potent lipoxidase and lactate dehydrogenase inhibitors in Stellera chamaejasme extracts. The results demonstrate that our method of ultrafiltration with liquid chromatography and mass spectrometry combined with mixed chromatography can be used to screen and confirm the bioactivity of all isolated compounds. This method also eliminates the need for separation of inactive compounds, thereby improving efficiency when studying bioactive substances. For some complex mixtures, neither semi‐preparative high‐performance liquid chromatography nor high‐speed counter‐current chromatography can purify all the target active compounds with high purity in a one‐step separation. The combination of the two methods allow for efficient purification of target bioactive compounds with different polarities and physicochemical properties based on their complementary properties.  相似文献   

19.
Inter-molecular interactions involved in the hydrolysate were studied in order to explain heme and peptide high retentions observed during the ultrafiltration of a bovine hemoglobin peptidic hydrolysate with a 10 kDa modified polyethersulfone membrane.Physico-chemical properties of the peptidic fractions of the retentate and of the permeate were characterized by UV/vis spectroscopy, SDS-PAGE electrophoresis, size-exclusion chromatography, reversed phase HPLC, hydrophobic interaction chromatography on hemin agarose, precipitation with sodium chloride and amino acid compositions. Two populations of peptides were revealed in the hydrolysate: one forming high-molecular weight hydrophobic associations retained by the membrane, and another more hydrophilic, giving no associations and freely passing through the membrane. Contrary to the peptides of the permeate, peptides retained by the membrane had a high affinity and a large binding capacity for the heme. Heme as polymers is mainly linked by hydrophobic interactions with peptide associations to form large heme–peptide aggregates. These results suggest that high rejections of heme and peptide, often reported in the literature, during ultrafiltration of hemoglobin hydrolysates, could be largely explained by these associations.  相似文献   

20.
In electrodialysis desalination processes, the operating current density is limited by concentration polarization. In contrast to other membrane processes such as ultrafiltration, in electrodialysis, current transport above the limiting current is possible. In this work, the origin of the overlimiting current at cation-exchange polymers is investigated. We show that, under certain experimental conditions, electroconvection is the origin of the overlimiting conductance. The theory concerning electroconvection predicts a shortening of the plateau length of membranes with increased conductive or geometrical heterogeneity. We investigate the influence of these two parameters and show that the creation of line undulations on the membrane surface normal to the flow direction, having distances in the range of approximately 50-200% of the boundary-layer thickness, lead to an earlier onset of the overlimiting current. The plateau length of the undulated membranes is reduced by up to 60% compared to that of a flat membrane. These results verify the existence of electroconvection as a mechanism destabilizing the laminar boundary layer at the liquid-membrane interface and causing ionic transport above the limiting current density.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号