首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
Kang J  Wistuba D  Schurig V 《Electrophoresis》2002,23(7-8):1116-1120
A method for the preparation of a silica monolithic capillary electrochromatography (CEC) column for the separation of enantiomers has been developed. The porous silica monolith was fabricated inside a fused-silica capillary column by using the sol-gel process. After gelation for 24 h, hydrothermal treatment at 100 degrees C for 24 h was performed to prevent the sol-gel matrix from cracking. The prepared monolith was then coated with Chirasil-beta-Dex which represents a chiral polymer prepared by grafting permethyl-beta-cyclodextrin to polymethylsiloxane with an octamethylene spacer. Immobilization of Chirasil-beta-Dex was performed by heat treatment at 120 degrees C for 48 h to give a nonextractable coating. The column performance was evaluated by using racemic hexobarbital as a model compound. The efficiency of 9.2 x 10(4) theoretical plates/m for the first eluted enantiomer of hexobarbital was obtained at an optimal flow rate of the mobile phase. The effect of mobile phase composition on enantiomeric separation of hexobarbital was also investigated. The column proved to be stable for more than one hundreds of runs during a two-months period. The enantiomers of several neutral and negatively charged chiral compounds were baseline separated on this column.  相似文献   

2.
This work reports the preparation of monolithic zirconia chiral columns for separation of enantiomeric compounds by capillary electrochromatography (CEC). Using sol–gel technology, a porous monolith having interconnected globular-like structure with through-pores is synthesized in the capillary column as a first step in the synthesis of monolithic zirconia chiral capillary columns. In the second step, the surface of the monolith is modified by coating with cellulose tris(3,5-dimethylphenylcarbamate) (CDMPC) as the chiral stationary phase to obtain a chiral column (CDMPCZM). The process of the preparation of the zirconia monolithic capillary column was investigated by varying the concentrations of the components of the sol solution including polyethylene glycol, water and acetic acid. CDMPCZM is mechanically stable and no bubble formation was detected with the applied current of up to 30 μA. The enantioseparation behavior of the CDMPCZM columns was investigated by separating a set of 10 representative chiral compounds by varying the applied voltage and pH and organic composition of the aqueous organic mobile phases.  相似文献   

3.
Chen Z  Ozawa H  Uchiyama K  Hobo T 《Electrophoresis》2003,24(15):2550-2558
We describe beta- and gamma-cyclodextrins (beta- and gamma-CD)-modified monolithic columns prepared by sol-gel process and chemical modifications. The monolithic silica column was fabricated inside a fused-silica capillary with 100 microm inner diameter by sol-gel process. The monolithic silica matrix was chemically modified chiral selectors of beta- or gamma-CDs with a spacer of 3-glycidoxypropyltrimethoxysilane by on-column reactions. Gamma-CD-modified monolithic column has successfully been applied for the separation of dansyl amino acid enantiomers. Beta-CD-modified monolithic column has been used for the separation of the positional isomers of o-, m-, and p-cresols and the enantioseparation of racemates of benzoin and several dansyl amino acids by capillary electrochromatography, respectively. For the separation of neutral positional isomers, a positive electric field was applied. However, for the separation of negatively charged analytes, a negative electric field was applied at the inlet of column. The separation efficiency of 5.0 x 10(4) theoretical plates/m for dansyl-L-threonine was obtained at electric field strength of -300 V/cm in the mobile phase of 50 mM 2-(N-morpholino)ethanesulfonic acid (MES)-Tris/methanol (70/30) buffer at pH 7.0. L-enantiomers were eluted as the first peak. Scanning electron micrograph showed that monolithic columns have the morphology of continuous skeleton and large through-pores.  相似文献   

4.
Dong X  Dong J  Ou J  Zhu Y  Zou H 《Electrophoresis》2007,28(15):2606-2612
Enantiomeric separations in CEC with the macrocyclic antibiotic vancomycin immobilized silica monolith as a chiral stationary phase are presented. The monolithic silica capillary columns were prepared by a sol-gel process in fused-silica capillaries with an inner diameter of 50 mum and subsequently in situ immobilization of vancomycin as a chiral selector by reductive amination. Enantioselectivity was obtained for eight pairs of enantiomers in nonaqueous polar organic or aqueous mobile phases and most of them were baseline-separated with high column efficiencies. It was observed that the organic modifier ratio (MeOH/ACN) in the polar organic mobile phase played a significant role in controlling the resolution and efficiency of the enantiomers. In enantiomeric separation of propranolol, repeatability for column efficiency and resolution in the nonaqueous mobile phase was given in terms of RSD values at 1.1 and 2.3% (n = 5) for run-to-run injections and 7.2 and 9.6% (n = 5) for column-to-column testing while repeatability for the separation of thalidomide in the aqueous mobile phase was given in terms of RSD values at 1.5, 2.8% and 6.1, 10.5%, respectively.  相似文献   

5.
采用一步键合法制备了烯丙胺-β-环糊精/Cu_2O(Ally-β-CD/Cu_2O)毛细管电色谱整体柱,并考察了制备整体柱的主要影响因素。通过扫描电子显微镜(SEM)、X-射线光电子能谱(XPS)、X-射线衍射(XRD)对整体柱柱内固定相进行表征。以硫脲为中性标记物测定了柱效,柱效达到47 658 N/m。对D,L-组氨酸对映体的分离度RS达到3.82,整体柱在连续使用72h或间歇使用2个月后仍具有良好的分离能力,表明整体柱具有良好的重现性和稳定性,同时具备较好的手性拆分能力。运用该整体柱对盐酸克伦特罗对映体进行了拆分,达到基线分离,分离度达到2.89。  相似文献   

6.
The 3,5-dimethylphenylcarbamate derivatives of cellulose bearing 3-(triethoxysilyl)propyl residues were immobilized in a capillary format onto a monolithic silica support by intermolecular polycondensation of the triethoxysilyl groups. The resulting columns were used for chiral separations using capillary electrochromatography. The effects of the synthesizing solvent, the selector coating procedure, the chiral selector concentration onto the silica monolith and the mobile phase pH value, on the separation of enantiomers were studied. The column-to-column reproducibility and stability also were evaluated. A test set of 14 chiral substances, including acidic, neutral, bifunctional and basic compounds, was used to investigate the effects of the factors mentioned above. Twelve pairs of enantiomers showed enantioselectivity at some of the different conditions tested. The column-to-column repeatability was satisfactory, and the prepared columns were stable under the adopted analysis conditions.  相似文献   

7.
胃蛋白酶亲和有机聚合物毛细管整体柱的制备及性能考察   总被引:1,自引:0,他引:1  
池翠杰  王伟  季一兵 《色谱》2014,32(8):791-797
以热引发原位聚合方法制备了聚(甲基丙烯酸缩水甘油酯(glycidyl methacrylate,GMA)-乙二醇二甲基丙烯酸酯(ethyleneglycol dimethacrylate,EDMA))毛细管整体柱,对整体柱的性能进行了表征。结果表明,柱内部结构均匀、渗透性好;整体柱能够实现苯等中性小分子化合物的分离,具有反相色谱特征,重现性和稳定性良好。利用整体柱环氧基团的活性,采用间接法,以戊二醛为连接臂制备胃蛋白酶亲和手性整体柱。在毛细管电色谱模式下进行了柱分离性能研究,并对缓冲液pH值和运行电压等分离条件进行了考察。结果表明,亲和整体柱对4种碱性手性药物(奈福泮、氨氯地平、西酞普兰、扑尔敏)有拆分效果,奈福泮、氨氯地平、西酞普兰能达到基线分离。本文为蛋白质亲和毛细管电色谱整体柱的制备和应用提供了新的思路和方法。  相似文献   

8.
A chiral capillary monolithic column for enantiomer separation in capillary electrochromatography was prepared by coating cellulose tris(3,5‐dimethylphenylcarbamate) on porous glycidyl methacrylate‐co‐ethylene dimethacrylate monolith in capillary format grafted with chains of [2(methacryloyloxy)ethyl] trimethylammonium chloride. The surface modification of the monolith by the photografting of [2(methacryloyloxy)ethyl] trimethylammonium chloride monomer as well as the coating conditions of cellulose tris(3,5‐dimethylphenylcarbamate) onto the grafted monolithic scaffold were optimized to obtain a stable and reproducible chiral stationary phase for capillary electrochromatography. The effect of organic modifier (acetonitrile) in aqueous mobile phase for the enantiomer separation by capillary electrochromatography was also investigated. Several pairs of enantiomers including acidic, neutral, and basic analytes were tested and most of them were partially or completely resolved under aqueous mobile phases. The prepared monolithic chiral stationary phases exhibited a good stability, repeatability, and column‐to‐column reproducibility, with relative standard deviations below 11% in the studied electrochromatographic parameters.  相似文献   

9.
Macroporous poly(styrene-divinylbenzene) monolithic columns were prepared in fused silica capillaries of 100 microm id by in-situ copolymerization of styrene with divinylbenzene in the presence of propan-1-ol and formamide as the porogen system. The monoliths were subsequently alkylated with linear alkyl C-18 groups via Friedel-Crafts reaction to improve the retention and chromatographic resolution of strongly polar phenolic acids. A new thermally initiated grafting procedure was developed in order to shorten the time of the alkylation process. The grafting procedure was optimized with respect to the reaction temperature, time, the grafting reactant concentration, and the solvent used. The type of solvent and the grafting temperature are the most significant factors affecting the hydrodynamic properties, porosity, and efficiency of the columns. While the equivalent particle diameter of the grafted column increased, the capillary-like flow-through pore diameter decreased in comparison to non-alkylated monoliths. The hydrodynamic permeability of the monolith decreased, but the monolithic column still permitted fast micro-HPLC separations.  相似文献   

10.
A silica-based monolithic stationary phase prepared by the sol-gel process in a 100 microm I.D. fused-silica (FS) capillary has been modified chemically with 3-mercaptopropyl trimethoxysilane followed by immobilization of a strong cation-exchange (SCX) type chiral selector, (S)-N-(4-allyloxy-3,5-dichlorobenzoyl)-2-amino-3,3-dimethylbutane phosphonic acid, by radical addition reaction onto the reactive sulfhydryl surface. After a fine-tuning of the mobile phase composition, the enantioselective capillary column was evaluated for the separation of various chiral basic drugs by enantioselective non-aqueous capillary electrochromatography (CEC), in comparison to capillary column analogs packed with 3.5 microm silica particles having attached the same selector. The performance of the monolithic silica column was further compared to corresponding polymethacrylate-based organic polymer monoliths. The study indicated that strong counter-ions such as 2-aminobutanol or N,N,N',N'-tetramethylethylenediamine are needed, although they reduce the electroosmotic flow velocity and separation factors in comparison to less efficient counter-ions, in order to allow the elution of the oppositely charged solutes in the ion-exchange retention mode within reasonable run time and as sharp zones. In contrast, weak counter-ions such as N,N-diisopropylethylamine (Huenig base) provided stronger electroosmotic flow and much better separation factors, but relatively poor peak efficiencies. Overall, with the chemically functionalized monolithic silica column the high quality separations of packed column analogs could be approximated, with regards to both separation factors and peak performances. On the other hand, the monolithic capillary column certainly outperformed the packed column in terms of system robustness under capillary electrochromatography conditions and showed excellent column longevity. The enantioselective strong cation-exchange-type monolithic silica column performed also well in comparison to the organic polymer monolith.  相似文献   

11.
Liu Y  Heyden YV  Mangelings D 《Electrophoresis》2012,33(11):1613-1623
Chiral monolithic silica capillary columns were prepared by immobilization of amylose-3,5-dimethylphenylcarbamate (ADMPC) bearing a small fraction of 3-(triethoxysilyl)propyl residues through intermolecular polycondensation of the triethoxysilyl groups. The obtained columns were used for chiral separations in capillary electrochromatography (CEC). The effects of the silica monolith nature and the used chiral selector concentration on the resulting enantiomeric separations were investigated. Fifteen chiral compounds, including acidic, neutral, and basic substances were evaluated and twelve showed partial or baseline separation at some of the different conditions tested. These results demonstrated the promising applicability of ADMPC-immobilized monolithic silica columns in CEC enantioseparations, but also revealed the need for further improvements on the level of baseline separations and efficiencies.  相似文献   

12.
Porous zirconia monolith (ZM) modified with cellulose 3,5-dimethylphenylcarbamate (CDMPC) was used as chiral stationary phase to separate basic chiral compounds in capillary electrochromatography. The electroosmotic flow behavior of bare and CDMPC-modified zirconia monolithic (CDMPC-ZM) column was studied in ACN/phosphate buffer eluents of pH ranging from 2 to 12. The CDMPC-ZM column was evaluated by investigating the influences of pH, the type and composition of organic modifier of the eluent on enantioseparation. CEC separations at pH 9 provided the best resolutions for the analytes studied, which are better than those observed on CDMPC-modified silica monolithic columns under similar chromatographic conditions. No appreciable decline in retention and resolution factors after over 200 injections, and run-to-run and day-to-day repeatabilities of the column of less than 3% indicate the stability of the zirconia monolithic column in basic media.  相似文献   

13.
A new type of polymethacrylate‐based monolithic column with chiral stationary phase was prepared for the enantioseparation of aromatic amino acids, namely d ,l ‐phenylalanine, d ,l ‐tyrosine, and d ,l ‐tryptophan by CEC. The monolithic column was prepared by in situ polymerization of butyl methacrylate (BMA), N‐methacryloyl‐l ‐histidine methyl ester (MAH), and ethylene dimethacrylate (EDMA) in the presence of porogens. The porogen mixture included DMF and phosphate buffer. MAH was used as a chiral selector. FTIR spectrum of the polymethacrylate‐based monolith showed that MAH was incorporated into the polymeric structure via in situ polymerization. Some experimental parameters including pH, concentration of the mobile phase, and MAH concentration with regard to the chiral CEC separation were investigated. Single enantiomers and enantiomer mixtures of the amino acids were separately injected into the monolithic column. It was observed that l ‐enantiomers of aromatic amino acids migrated before d ‐enantiomers. The reversal enantiomer migration order for tryptophan was observed upon changing of pH. Using the chiral monolithic column (100 μm id and 375 μm od), the best chiral separation was performed in 35:65% ACN/phosphate buffer (pH 8.0, 10 mM) with an applied voltage of 12 kV in CEC. SEM images showed that the chiral monolithic column has a continuous polymeric skeleton and large through‐pore structure.  相似文献   

14.
An enantioselective silica rod type chiral stationary phase (CSP) is presented as a novel combination of the well-known enantiomer separation properties of immobilized tert-butyl-carbamoylquinine chiral anion-exchanger selector with the unique properties of monolithic silica material. The chromatographic behavior of the tert-butyl-carbamoylquinine silica rod was studied and compared with a similar prepared particulate material. Good selectivities were achieved for a spectrum of chiral test components like N-derivatized amino acids (DNB- Ac-, DNZ-, Bz-, Z-amino acids) and for Suprofen. The influence of mobile phase parameters, as well as the effect of serially coupling up to six 10 cm monolithic silica columns was studied and put in context to conventional columns of particulate 5 microm type CSP. Using that 60 cm long monolithic column it was possible to improve the enantiomer separation of Suprofen and achieve a baseline separation in less than 10 min of total separation time.  相似文献   

15.
This review draws attention to the use of chiral monolithic silica HPLC columns for the enantiomeric separation and determination of chiral compounds. Properties and advantages of monolithic silica HPLC columns are also highlighted in comparison to conventional particle-packed, fused-core, and sub-2-µm HPLC columns. Nano-LC capillary monolithic silica columns as well as polymeric-based and hybrid-based monolithic columns are also demonstrated to show good enantioresolution abilities. Methods for introducing the chiral selector into the monolithic silica column in the form of mobile phase additive, by encapsulation and surface coating, or by covalent functionalization are described. The application of molecular modeling methods to elucidate the selector–selectand interaction is discussed. An application for enantiomeric impurity determination is also considered.  相似文献   

16.
A porous zwitterionic monolith was prepared by in situ covalent attachment of lysine to a γ‐glycidoxypropyltrimethosysilane‐modified silica monolith. The prepared column was used to perform neutral and ionized solutes separations by pressurized (pCEC). Due to the zwitterionic nature of the resulting stationary phase, the monolithic column provided both electrostatic attraction and repulsion sites for electrochromatographic retention for ionized solutes. Separation of several nucleotides was investigated on the monolithic column. It was shown that the nucleotides could be separated based on hydrophilic and electrostatic interactions between the stationary phase and analyte. Besides, the separation property of the zwitterionic silica monolith was compared with the use of diamine‐bonded silica monolith as stationary phase. As expected, the lysine monolith exhibited a lower retention for the five nucleotides, which was due to the dissociation of the external carboxylic acid groups, leading to electrostatic repulsion with negatively charged solutes. Under the same experimental conditions, separation of the five nucleotides on the zwitterionic column was in less than 8 min, while that on the diamine column was in approximately 60 min.  相似文献   

17.
The separation of enantiomers of 10 chiral antimycotic drugs was studied on polysaccharide-based chiral columns with polar organic mobile phases. The emphasis was placed on some interesting examples of enantiomer elution order reversal observed depending on the chemistry of the chiral selector, separation temperature, major component, as well as the minor additive in the mobile phase. In particular, it was found that the elution order of enantiomers of chiral drug terconazole was opposite on cellulose- and amylose-based columns with the same pendant group. The affinity pattern of enantiomers of another chiral drug bifonazole was opposite towards to two amylose-based chiral selectors with different pendant groups. The affinity pattern of terconazole enantiomers also changed on some columns when the alcohol-based mobile phase was replaced with acetonitrile. An interesting effect of the minor acidic (formic acid) additives to the mobile phase on the affinity pattern of terconazole enantiomers was observed on Cellulose-2 and Cellulose-4 columns. In addition, a reversal of elution order of bifonazole enantiomers was observed on Amylose-2 column by variation of a separation temperature.  相似文献   

18.
Protein separations were carried out by micro-high performance liquid chromatography (micro-HPLC) with surface alkylated monolithic columns, which were prepared by in situ copolymerization of glycidyl methacrylate (GMA) and ethylene glycol dimethacrylate (EGDMA) in the presence of dodecanol and toluene as porogens. First, glycidyl groups at the surface of the porous monolith were hydrolyzed with sulfuric acid. The hydroxyl groups thus formed were then reacted with n-alkyl chloride to form alkylated stationary phase. Separation performance for proteins on columns with C18 and C8 stationary phases was compared. The results showed that a poly(GMA-EGDMA) support derivatized with octadecyl moieties could achieve much better resolution than one with octyl groups. A protein mixture was separated with the octadecylated poly-(GMA-EGDMA) monolithic column, and the effluent peaks were collected and analyzed by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). The physical properties of the monolithic columns such as column morphology, surface area, mesopore size distribution, and column permeability were further characterized by scanning electron microscopy (SEM), multipoint BET nitrogen adsorption/desorption, and Darcy's law, respectively.  相似文献   

19.
《Analytical letters》2012,45(16):2377-2388
Capillary electrochromatography (CEC) is important for applications in enantiomer separation. The problems associated with column fabrication bring a challenge in developing monoliths with ease of preparation, robustness of separation, enhanced mass transfer, and lower pressure drop. In this research, the covalent binding of proteins on to a monolithic matrix was investigated to overcome the drawback of loss and/or denaturing of the biomolecules from physical adsorption and encapsulation method. A chitosan/silica hybrid monolith was prepared and a protein, bovine serum albumin, was covalently immobilized on the column. The prepared monolith was evaluated using the enantioseparation of D,L-tryptophan by CEC. It was found that separation of tryptophan enantiomers with a resolution of 2.44 was achieved by using 20 mmol L?1 phosphate buffer at pH 7.5. A higher chitosan concentration was also proven to be of possible use in the synthesis with the aid of acetic acid as the solvent. The much shorter retention time and increased separation ability demonstrate the advantages of capillary column under investigation.  相似文献   

20.
An affinity monolith based on silica and containing immobilized alpha(1)-acid glycoprotein (AGP) was developed and evaluated in terms of its binding, efficiency and selectivity in chiral separations. The results were compared with data obtained for the same protein when used as a chiral stationary phase with HPLC-grade silica particles or monoliths based on a copolymer of glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA). The surface coverage of AGP in the silica monolith was 18% higher than that obtained with silica particles and 61% higher than that measured for a GMA/EDMA monolith. The higher surface area of the silica monolith gave materials that contained 1.5- to 3.6-times more immobilized protein per unit volume when compared to silica particles or a GMA/EDMA monolith. The retention, efficiency and resolving power of the AGP silica monolith were evaluated by injecting two chiral analytes onto this column (i.e., R/S-warfarin and R/S-propranolol). In each case, the AGP silica monolith gave higher retention plus better resolution and efficiency than AGP columns containing silica particles or a GMA/EDMA monolith. The AGP silica monolith also gave lower back pressures and separation impedances than these other materials. It was concluded that silica monoliths can be valuable alternatives to silica particles or GMA/EDMA monoliths when used with AGP as a chiral stationary phase.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏