首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 223 毫秒
1.
The 3,5-dimethylphenylcarbamate derivatives of cellulose bearing 3-(triethoxysilyl)propyl residues were immobilized in a capillary format onto a monolithic silica support by intermolecular polycondensation of the triethoxysilyl groups. The resulting columns were used for chiral separations using capillary electrochromatography. The effects of the synthesizing solvent, the selector coating procedure, the chiral selector concentration onto the silica monolith and the mobile phase pH value, on the separation of enantiomers were studied. The column-to-column reproducibility and stability also were evaluated. A test set of 14 chiral substances, including acidic, neutral, bifunctional and basic compounds, was used to investigate the effects of the factors mentioned above. Twelve pairs of enantiomers showed enantioselectivity at some of the different conditions tested. The column-to-column repeatability was satisfactory, and the prepared columns were stable under the adopted analysis conditions.  相似文献   

2.
3.
Porous zirconia monolith (ZM) modified with cellulose 3,5-dimethylphenylcarbamate (CDMPC) was used as chiral stationary phase to separate basic chiral compounds in capillary electrochromatography. The electroosmotic flow behavior of bare and CDMPC-modified zirconia monolithic (CDMPC-ZM) column was studied in ACN/phosphate buffer eluents of pH ranging from 2 to 12. The CDMPC-ZM column was evaluated by investigating the influences of pH, the type and composition of organic modifier of the eluent on enantioseparation. CEC separations at pH 9 provided the best resolutions for the analytes studied, which are better than those observed on CDMPC-modified silica monolithic columns under similar chromatographic conditions. No appreciable decline in retention and resolution factors after over 200 injections, and run-to-run and day-to-day repeatabilities of the column of less than 3% indicate the stability of the zirconia monolithic column in basic media.  相似文献   

4.
Monolithic columns for capillary electrochromatography (CEC) are receiving quite remarkable attention. Both the simplicity of the in situ preparation and the large number of readily available chemistries make the monolithic separation media a vital alternative to capillary columns packed with particulate materials. This review summarizes the current state-of-the-art in this rapidly growing area of CEC with a focus on monolithic capillary columns prepared from synthetic polymers. Recent achievements in column technologies for both high-performance liquid chromatography and capillary electrophoresis are used as the starting point to highlight the influence of these well established analytical methods on the development of monolithic capillary columns for CEC. The effects of individual variables on the separation properties of monolithic capillaries are discussed in detail. The analytical potential of these columns is demonstrated with separations involving various families of compounds in different chromatographic modes.  相似文献   

5.
Designed especially for capillary electrochromatography (CEC), silicate-entrapped columns are made by trapping particles of chromatographic packing material in a network of silica. Once entrapped, the capillary no longer requires frits. This renders a more homogeneous and stable packed bed. Accidental breakage of the fragile frits is not an issue with these robust columns. Columns packed with reverse-phase material subjected to silicate entrapment demonstrated faster separations of retained analytes and increased efficiencies compared with nonentrapped columns. The method was also used to prepare chiral CEC columns by entrapping a molecular imprinted polymeric (MIP) packing having minimal surface charge density, thus being unable alone to support sufficient electroosmotic flow for CEC.  相似文献   

6.
Enantioseparations of chiral compounds with different structures were studied in non-aqueous capillary electrochromatography (NAQ CEC). Three different polysaccharide derivatives, cellulose tris(3,5-dimethylphenylcarbamate) (Chiralcel OD), amylose tris(3,5-dimethylphenylcarbamate) (Chiralpak AD) and cellulose tris(4-methylbenzoate) (Chiralcel OJ) were used as chiral stationary phases (CSPs). Methanolic or ethanolic ammonium acetate solutions served as a mobile phase. The effect of the type of the CSP, the loading of the chiral selector on wide-pore aminopropyl derivatized silica gel and operational parameters such as apparent pH, applied voltage, etc. on the EOF and chromatographic characteristics (alpha, N, Rs) were studied. NAQ CEC represents a valuable alternative and an extension to chiral separations by HPLC with common-size columns as well as to capillary LC and CEC in aqueous buffers.  相似文献   

7.
Kang J  Wistuba D  Schurig V 《Electrophoresis》2002,23(22-23):4005-4021
Recent progress in enantiomeric separations by capillary electrochromatography (CEC) is reviewed. The development of simple and robust CEC column technologies plays an important role for popularization of CEC. During the last several years, various approaches for the preparation of enantioselective columns have been reported. Currently, the monolithic column technology (continuous beds) represents the most advanced approach for the preparation of CEC columns. The development of new chiral stationary phase used for CEC is another important issue in this field. Fundamental investigations on electrochromatographic behaviors of various CSPs are necessary in order to understand the separation mechanism and thus improve the separation performance. Some chiral stationary phases performed better under nonaqueous CEC conditions than reversed-phase conditions. Coupling CEC with mass spectrometry (MS) provides a powerful tool for enantiomeric separation. Finally, some applications of enantiomeric separation by CEC are summarized.  相似文献   

8.
Enantioseparations in nonaqueous capillary electrochromatography (CEC) are reported in this study for the first time, using wide-pore aminopropyl silica gel coated with helically chiral poly(diphenyl-2-pyridylmethyl methacrylate) (PDPM) as chiral stationary phase (CSP). The anodic electroosmotic flow (EOF) in a methanolic solution of ammonium acetate was used for the migration of neutral analytes through the packed bed in the capillaries. Four different techniques, high-performance liquid chromatography (HPLC) in common-size columns, capillary HPLC, pressure-assisted CEC and CEC were compared from the viewpoint of separation parameters. The latter three were performed with the same experimental setup, varying the relative contribution of the pressure-driven and the electrically driven flow to the overall mobility of the analyte. Capillary HPLC offers clear advantages compared to enantioseparations in common-size columns. However, for a given particle size of the packing material, CEC was not obviously advantageous compared to pressure-driven separations.  相似文献   

9.
Monolithic capillary columns containing native silica gel were modified with cellulose tris(3,5-dimethylphenylcarbamate) (CDMPC) and used for enantioseparations in capillary liquid chromatography. The method adopted for in situ enantioselective modification of monolithic fused silica capillary columns by coating with CDPMC appears to be fairly simple and fast. High efficiency enantioseparations of test racemic compounds and s(everal chiral drugs were achieved in a short time. It was possible to increase the amount of chiral selector present by multiple coating of monoliths with CDMPC. The baseline enantioseparation of 2,2,2-trifluoro-1-(9-anthryl)ethanol was achieved in an analysis time less than 30 s with this capillary column. In addition, reproducible enantioseparations were obtained when the chiral selector was removed from the monolithic column by flushing it with appropriate solvent and the column recoated.  相似文献   

10.
A nonaqueous CEC method for the simultaneous separation of the four stereoisomers of the N-benzyloxycarbonyl phosphinic pseudodipeptide methyl ester benzyloxycarbonyl-homophenylalanine Z-hPhepsi(PO2HCH2)Phe-OCH3 as well as of the corresponding N-2,4-dinitrophenyl (DNP)-derivative with free C-terminal carboxylic group DNP-hPhepsi(PO2HCH2)Phe-OH was developed. For this purpose, a monolithic silica capillary column modified with a cinchona alkaloid-derived anion-exchange-type chiral selector, namely O-9-(tert-butylcarbamoyl)quinidine (tBuCQD) was prepared. The mobile phase composition (ACN/methanol ratio, counterion type) was thoroughly optimized to end up with baseline resolution of all four stereoisomers with critical resolution of as high as about 2. The CEC method proved to be superior over the corresponding HPLC separations primarily due to significantly enhanced plate numbers (between 200,000 and 600,000 m(-1) in CEC). Diastereoselectivity contributions arising from electrophoretic mobility differences of the diastereomers facilitated the separation of the later eluted diastereomeric peak pair (peaks III and IV), but had a negative influence on the selectivity of the earlier eluted diastereomeric peak pair (peaks I and II). The stereoselective CEC assay allowed the assessment of the stereoisomeric purity of the individual isomers which were obtained by preparative HPLC on a CHIRALPAK QD-AX column that is based on the same tBuCQD selector. The present study demonstrates that there exist problems which are hard to solve by HPLC, yet can be conveniently solved by CEC. Moreover, it was intended to prove by this practical application that CEC with monolithic columns is robust enough to be used for solving real-life problems.  相似文献   

11.
Liu Z  Otsuka K  Terabe S  Motokawa M  Tanaka N 《Electrophoresis》2002,23(17):2973-2981
The physical adsorption method proposed previously has been successfully applied to a monolithic silica column. By virtue of the physical adsorption, a chiral stationary phase of avidin was prepared onto the silica monolith. The phase ratio of resulting stationary phase was evaluated with frontal analysis. The method proved to be comparable in phase ratio to the chemical bonding methods used in high-performance liquid chromatography (HPLC). Enantiomer separations were carried out in capillary electrochromatography (CEC) and capillary liquid chromatography (CLC) modes. Due to its larger phase ratio, the resulting column showed more powerful separation capability as compared to open-tubular CEC (OTCEC). Twelve chiral compounds were baseline-resolved. The resulting column showed high separation efficiency, with average theoretical plate numbers of 66 000/m for CLC and 122 000/m for CEC. Good reproducibility was observed, with RSD value less than 1.3% for retention time, retention factor and separation factor, and less than 6.6% for plate counts and resolution (n = 40). Fast separations were achieved with a short column. The test enantiomers were baseline-resolved within 4 min under CLC and CEC modes. In addition, field-enhanced sample injection (FESI) was coupled to CLC as well as CEC to improve the detection sensitivity.  相似文献   

12.
Monolithic silica columns of 2.7 mm ID were prepared and derivatized with C8-TEOS and TEOS by on-column sol-gel reaction. These C8 large diameter monolithic silica columns gave 21 000 theoretical plates for aromatic hydrocarbons in 60% acetonitrile and 40% Tris-HCI buffer. The surface areas as well as the separation reproducibility were improved on coating by the sol-gel approach. Joule heating was greatly reduced by using monolithic columns to which fine quartz sand had been added during column preparation. Since this is a preliminary investigation on a monolithic column with such a large inner diameter, the separation efficiency was not so high as that presently achieved in normal capillary electrochromatography (CEC). However, use of the columns improved sample loadability and concentration detectability of electrochromatography, and semi-preparative separations could be performed.  相似文献   

13.
The current popularity of capillary electrochromatography (CEC) has led to an increasing number of studies on the development and evaluation of enantioselective CEC systems. These studies clearly demonstrate that the most prominent advantage of electrically driven separation methods, the vastly increased column efficiency as compared to pressure-driven chromatography, can also be experimentally achieved for the separations of enantiomers. In analogy to high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE), several approaches have been used. The addition of a chiral selector to the mobile phase is the simplest method. Less erroneous and more elegant approaches are those that use open-tubular, conventional packed, and monolithic columns containing chiral stationary phases that stereoselectively interact with enantiomers. This review evaluates the new techniques and compares them to enantioselective HPLC and CE. Further, it describes the various concepts of enantioselective CEC and focuses on the current ‘state-of-the-art' column technology.  相似文献   

14.
Hilder EF  Svec F  Fréchet JM 《Electrophoresis》2002,23(22-23):3934-3953
This review summarizes the contributions of a number of groups working in the rapidly growing area of monolithic columns for capillary electrochromatography (CEC), with a focus on those prepared from synthetic polymers. Monoliths have quickly become a well-established stationary phase format in the field of CEC. The simplicity of their in situ preparation method as well as the good control over their porous properties and surface chemistries make the monolithic separation media an attractive alternative to capillary columns packed with particulate materials. A wide variety of approaches as well as materials used for the preparation of the monolithic stationary phases are detailed. Their excellent chromatographic performance is demonstrated by numerous separations of different analytes.  相似文献   

15.
胃蛋白酶亲和有机聚合物毛细管整体柱的制备及性能考察   总被引:1,自引:0,他引:1  
池翠杰  王伟  季一兵 《色谱》2014,32(8):791-797
以热引发原位聚合方法制备了聚(甲基丙烯酸缩水甘油酯(glycidyl methacrylate,GMA)-乙二醇二甲基丙烯酸酯(ethyleneglycol dimethacrylate,EDMA))毛细管整体柱,对整体柱的性能进行了表征。结果表明,柱内部结构均匀、渗透性好;整体柱能够实现苯等中性小分子化合物的分离,具有反相色谱特征,重现性和稳定性良好。利用整体柱环氧基团的活性,采用间接法,以戊二醛为连接臂制备胃蛋白酶亲和手性整体柱。在毛细管电色谱模式下进行了柱分离性能研究,并对缓冲液pH值和运行电压等分离条件进行了考察。结果表明,亲和整体柱对4种碱性手性药物(奈福泮、氨氯地平、西酞普兰、扑尔敏)有拆分效果,奈福泮、氨氯地平、西酞普兰能达到基线分离。本文为蛋白质亲和毛细管电色谱整体柱的制备和应用提供了新的思路和方法。  相似文献   

16.
毛细管电色谱具有高分离效率、多种保留机制和高选择性的优点。近年来,利用毛细管电色谱进行对映异构体的手性拆分受到了广泛关注。相对于传统的填充柱和开管柱,整体柱在手性拆分方面具有显著优势。与手性硅基整体柱相似,手性有机聚合物整体柱由于具有大孔,可产生较高的流速而压降较小。该文综述了近十年手性有机聚合物整体柱制备方法的研究进展,将手性有机聚合物整体柱的制备方法分为"原位聚合法"和"手性修饰法"两种,虽然前者制备简单并广泛应用于早期研究,但聚合混合液成分的微小改变即可引起最终聚合物的形态变化,并且大部分带丙烯基的手性选择剂较难从市场购买。因此,手性修饰法因作为手性选择剂基质的整体柱制备且优化只需进行一次的优势而受到普遍关注。亲核取代、杂环开环和点击化学是常用的修饰手段。该文总结了这两种制备方法的应用,同时对未来的研究方向提出参考性意见。  相似文献   

17.
Preparation methods of monolithic silica columns for HPLC including the surface modification were reviewed. Chemical modification methods recently reported to obtain stationary phases for reversed-phase (RP), chiral, ion-exchange, and hydrophilic interaction chromatography (HILIC) separations were discussed. Recent results related to preparation methods of monolithic silica were also covered. The characteristics and properties of silica monoliths and some applications of monolithic silica columns for different analytical and bioanalytical fields will be commented.  相似文献   

18.
A silica-bonded bovine serum albumin (BSA) chiral monolithic stationary phase for capillary electrochromatography(CEC) was introduced. An inorganic-organic hybrid monolithic column was firstly prepared by sol-gel chemistry with homogeneously distributed aminopropyl groups throughout the silica matrix. Then the chiral stationary phase was synthesized by the in situ covalent immobilization of BSA on the monolithic column activated with glutaraldehyde. The effects of pH value and concentration of phosphate buffer on the separation of D,L-tryptophan were investigated. The separation factor of D,L-tryptophan reached 3.37 on CEC mode.  相似文献   

19.
In this paper we report that Cu(II) complexes with L-amino acid amides were used as chiral selectors for enantioseparation by capillary electrophoresis, capillary electrochromatography (CEC) and micro liquid chromatography using chemically modified monolithic columns. The enantioselectivity, enantiomer migration order, and the performance have been compared when different chiral selectors were used in these modes. L-Enantiomers showed longer retention times than D-forms in both CEC and LC modes. However, it has interestingly been observed that the migration order of Dns-DL-Ser showed an exception in CEC using L-prolinamide-modified column that Dns-L-Ser was eluted as the first peak. On the basis of proposed structures of complexes in the chiral recognition, differences in migration orders and recognition mechanism were discussed.  相似文献   

20.
Gu C  Shamsi SA 《Electrophoresis》2011,32(19):2727-2737
Glycidyl methacrylate-bonded β-cyclodextrin (GMA-β-CD) is synthesized as a new chiral monomer by direct chemical bonding with GMA using a fast and simple alternative procedure. Next, rigid and homogenous monolithic columns were prepared by polymerization of GMA-β-CD monomer with ethylene dimethacrylate (EDMA), in the presence of commonly used porogens and a charged achiral monomer to form a versatile chiral monolith. This is the first report in which a preparation procedure for a methacrylate-bonded CD is introduced for chiral separations in CEC. The degree of substitution of GMA-β-CD monomer and mobile-phase parameters were optimized to achieve the highest enantioselectivity and plate number. To evaluate the GMA-β-CD monolithic column, different classes of chiral compounds were screened. Under the optimized β-CD monolith phase and the optimum mobile-phase conditions, 30 neutral and basic chiral compounds and two acidic compounds could be separated. The high chemical and mechanical stability, homogenous microflow and no loss of material at the interface allows for the first time the feasibility of applying this polymer-based monolithic column for CEC coupled to ESI-MS. Compared with CEC-UV, CEC-ESI-MS showed higher sensitivity and lower resolution. However, resolution greater than 1.0 can still be obtained for majority of the select tested compound in CEC-ESI-MS with at least three out of seven compound providing Rs≥1.5. The results reinforce the potential of GMA-β-CD monolithic columns for chiral separations with high sensitivity in CEC-ESI-MS. Finally, using hexobarbital as the model chiral analyte, the monolithic column demonstrated excellent stability and reproducibility of retention time and enantioselectivity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号