首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Liquid chromatography coupled to tandem mass spectrometry with a triple quadrupole analyser was used to determine selected (medium) polar organic pollutants—isoproturon, diuron and pentachlorophenol, as the herbicides simazine, atrazine, terbuthilazine, alachlor, and metolachlor—in treated water from urban solid-waste leachates. Two millilitres of water was preconcentrated by on-line trace enrichment (solid-phase extraction liquid chromatography) which allowed rapid analysis, but still with a satisfactory sensitivity, as the limits of quantification were 0.05?µg?L?1, while the limits of detection were in the range of 0.001–0.01?µg?L?1. Confirmation of the identity of compounds was ensured by the use of two tandem mass spectrometry transitions. Moreover, a study of matrix effects was thoroughly investigated by applying the developed procedure to different ground and surface waters. A simple dilution of the water sample with high-performance-liquid-chromatography-grade water was sufficient to minimize and/or remove this undesirable effect in all water samples tested, this approach being feasible due to the excellent sensitivity of the method.  相似文献   

2.
采用毛细管气相色谱法快速测定甘宝素产品中的甲苯残留量。样品经甲醇稀释,氢火焰离子化检测器检测,外标法计算含量。甲苯的质量浓度在3.2~25.6 mg/L范围内与色谱峰面积线性良好,相关系数r=0.999 3,方法的检出限为1.16 mg/L,样品的加标回收率为96.5%~102.8%(n=6),测定结果的相对标准偏差为3.2%~4.5%。该方法操作简便,灵敏度高,适合于实际生产中甲苯残留量的快速测定。  相似文献   

3.
An immunoaffinity chromatography extraction capillary liquid chromatography separation has been coupled to electrospray ionization mass spectrometry for on-line characterization of drug metabolites of a therapeutic peptide in plasma. It is demonstrated that the selectivity, sensitivity and molecular weight data provided by immunoaffinity chromatography coupled to liquid chromatography/mass spectrometry provides a means of rapidly achieving qualitative determinations of small amounts of material in complicated biological matrices such as plasma. The ability to detect the peptide in rat plasma at a level of 10 ng/mL is demonstrated using this method. In addition, experiments to study the epitope of the peptide by enzymatic digestion and mass spectrometry are also discussed. The method is proposed as an alternative approach to studying the metabolism of therapeutic peptides.  相似文献   

4.
A method based on ultra performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) in combination with solid‐phase extraction for sample pretreatment has been developed for the simultaneous analysis of amitriptyline and its main metabolite in human plasma. The extraction of the analytes from plasma samples was carried out by means of a selective SPE procedure using hydrophilic–lipophilic balance cartridges. The assay involves a simple solid‐phase extraction (SPE) procedure of 0.2 mL of human plasma and analysis was performed on a triple‐quadrupole tandem mass spectrometer by multiple reactions monitoring (MRM) mode via electrospray ionization (ESI). The standard calibration curve was linear over the ranges 0.370–95.539 ng/mL for amitriptyline and 0.365–94.374 ng/mL for nortriptyline, expressed by the linear correlation coefficient r2, which was better than 0.995 for both. The intra‐ and inter‐day precision and accuracy of the quality control samples were within 10.0%. The recovery was 85.3, 88.4 and 80.7% for amitriptyline, nortriptyline and doxepin respectively. Total run time was 1.2 min only for each sample, which makes it possible to analyze more than 400 samples per day. The method was highly reproducible and gave peaks with excellent chromatography properties. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
The analytical methods which are often used for the determination of cocaine in complex biological matrices are a prescreening immunoassay and confirmation by chromatography combined with mass spectrometry. We suggest an ultra‐high‐pressure liquid chromatography combined with a potentiometric detector, as a fast and practical method to detect and quantify cocaine in biological samples. An adsorption/desorption model was used to investigate the usefulness of the potentiometric detector to determine cocaine in complex matrices. Detection limits of 6.3 ng mL?1 were obtained in plasma and urine, which is below the maximum residue limit (MRL) of 25 ng mL?1. A set of seven plasma samples and 10 urine samples were classified identically by both methods as exceeding the MRL or being inferior to it. The results obtained with the UPLC/potentiometric detection method were compared with the results obtained with the UPLC/MS method for samples spiked with varying cocaine concentrations. The intraclass correlation coefficient was 0.997 for serum (n =7) and 0.977 for urine (n =8). As liquid chromatography is an established technique, and as potentiometry is very simple and cost‐effective in terms of equipment, we believe that this method is potentially easy, inexpensive, fast and reliable. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
A method has been developed for the simultaneous determination of antifouling pesticides and some of their degradation products, e.g. dichlofluanid, diuron, demethyldiuron, 1-(3,4-dichlorophenyl)urea, sea-nine, Irgarol 1051 and one of its metabolites (2-methylthio-4-tert-butylamino-s-triazine) in marine sediments. The determination of these compounds in sediment samples was performed by means of methanolic ultrasonic extraction then clean-up on an Isolute ENV+ solid phase extraction (SPE) cartridge. The resulting extract was then analyzed by reversed-phase high-performance liquid chromatography coupled with atmospheric-pressure chemical-ionization mass spectrometry in negative and positive ion modes (HPLC-APCI-MS). Recovery ranged from 54-109% for the antifouling agents and their degradation products. The determination limits for the different compounds varied between 0.2 and 1.6 microg kg(-1) dry sediment. The analytical procedure was successfully applied to the determination of these pesticides and their degradation products in marine sediment samples from different marinas of the Catalan coast. The compounds detected were: diuron, dichlofluanid, demethyldiuron, sea-nine, and Irgarol 1051. The highest concentrations were those of diuron and Irgarol 1051--136 and 88 microg kg(-1), respectively.  相似文献   

7.
A reliable assay procedure for the determination of 3,4-dihydroxyphenyl-L-alanine (dopa) and its O-methylated metabolite 3-O-methyldopa (3-OMD) is described. Supernatants from deproteinized plasma samples were directly injected into a column-switching system, allowing on-line prepurification of the samples by cation-exchange chromatography followed by reversed-phase high-performance liquid chromatography with electrochemical detection. With this method, the detector response was linear from endogenous levels of dopa and 3-OMD up to microgram concentrations. This technique combines the simplicity of direct injection methods with advantages of procedures using a sample clean-up. It represents a valid tool for the rapid and accurate measurement of large numbers of plasma samples in animals treated with levodopa and in clinical trials with new levodopa formulations.  相似文献   

8.
Microwave-assisted leaching of organotin compounds from sediment samples followed by the simultaneous extraction-derivatization of the extracted species was revisited with the goal to compare the existing procedures, improve their recoveries and extend them to phenyltin compounds. The stability of butyl- and phenyltin compounds under microwave field, real recoveries of the whole analytical procedure, effect of the extraction solvent, and the necessity for an internal standard were evaluated using two candidate reference sediments. The combination of the optimized sample preparation procedure with multicapillary chromatography resulted in a rapid (2 min leaching + 5 min extraction-derivatization + 3 min chromatographic separation) and efficient analytical procedure for speciation analysis of organotin compounds in sediment samples. The detection limit achieved with a microwave-induced plasma atomic emission detector was 2 ng g–1. Received: 27 July 1998 / Revised: 31 August 1998 / Accepted: 4 September 1998  相似文献   

9.
Cefepime monitoring in deproteinized human serum and plasma by micellar electrokinetic capillary chromatography and liquid chromatography coupled to mass spectrometry in presence of other drugs is reported. For micellar electrokinetic capillary chromatography, sample preparation comprised dodecylsulfate protein precipitation at pH 4.5 using an increased buffer concentration compared to that of a previous assay and removal of hydrophobic compounds with dichloromethane. This provided robust conditions for cefepime analysis in the presence of sulfamethoxazole and thus enabled its determination in samples of patients that receive cotrimoxazole. The liquid chromatography assay is based upon use of a column with a pentafluorophenyl‐propyl modified and multiendcapped stationary phase and the coupling to electrospray ionization with a single quadrupole detector. The performances of both assays with multilevel internal calibration were assessed with calibration and control samples and both assays were determined to be robust. Cefepime levels monitored by micellar electrokinetic capillary chromatography in samples from patients that were treated with cefepime only and with cefepime and cotrimoxazole were found to compare well with those obtained by liquid chromatography coupled to mass spectrometry. Cefepime drug levels determined by micellar electrokinetic capillary chromatography could thereby be validated.  相似文献   

10.
A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method, characterized by complete automation and high-throughput, was developed for the determination of colistin A and B in human plasma. All sample preparation procedures were performed by using 2.2 mL 96-deep-well plates, whereas robotic liquid-handling workstations were utilized for all liquid transfer steps, including solid-phase extraction (SPE). The whole preparation procedure was very rapid, whereas the method had a very short chromatographic run time of just 2 min. Sample analysis was performed by reversed phase LC-MS/MS, with positive electrospray ionization, using multiple reaction monitoring. The absence of available purified colistin A and B standards led to the development of a novel LC method with evaporative light-scattering detector for the determination of their stoichiometries in the standard mixture, along with its purity. The proposed bioanalytical method was fully validated and it was proven to be selective, accurate, precise, reproducible and suitable for the determination of colistin A and B in human plasma. It was applied successfully to a pharmacokinetic study for the determination of both analytes in samples of patients.  相似文献   

11.
A method for the determination of Thiamethoxam in bee samples was set up by means of high performance liquid chromatography with an electrochemical detector and post-column photochemical reactor (HPLC-h nu-ED). Analytical method was based on a rapid sample extraction procedure with acetone, followed by chromatographic separation into a C18-RP column isocratically operated by 60 mM phosphate buffer/acetonitrile (75/25) mobile phase at pH 2.7. A photochemical reactor was used as a tool to verify and eventually quantify the presence of Thiamethoxam in the samples by distinguishing it from interference contribution. Detection was performed with a potential of 880 mV after a photoactivation with a 254 nm light. The least detectable dose was 0.002 mg kg(-1). Recovery rates ranged between 59.88 and 71.62%.  相似文献   

12.
An on-line immunoaffinity column with liquid chromatography/tandem mass spectrometry (IAC-LC-MS/MS) method for the determination of diuron in water matrices was described. This method used a sol-gel immunoaffinity column (20 mm x 4 mm I.D.) for on-line sample cleanup and enrichment, a monolithic analytical column (100 mm x 4.6 mm I.D.) for separation, and a triple quadrupole mass spectrometer for quantitation. The major challenges for the on-line set-up were discussed. The optimized on-line protocol was emphasized by the fact that low limit of quantitation (LOQ) of 1.0 ng/L was achieved with only 2.5-mL sample. In addition, a satisfactory accuracy ( approximately 90% of recovery) and precision (<6% of relative standard deviation) at 50 ng/L concentration were also obtained. Due to the ability of the sol-gel immunoaffinity column to eliminate matrix effect, the on-line IAC-LC-MS/MS analysis method can reliably determine diuron in wastewater treatment plant effluent sample.  相似文献   

13.
The identification of hemoglobin (Hb) variants is usually performed by means of different analytical steps and methodologies. Phenotypic methods, such as gel electrophoresis and high performance liquid chromatography, are used to detect the different electrophoretic or chromatographic behaviors of hemoglobin variants in comparison to HbA0 used as a control. These data often need to be combined with mass spectrometry analyses of intact globins and their tryptic peptide mixtures. As an alternative to a 'step-by-step' procedure, we have developed a 'single step' approach for the identification of Hb variants present in biological samples. This is based on the microHPLC-ESI-MS/MS analysis of the peptide mixture generated by a tryptic digestion of diluted Hb samples and an in-house new database containing solely the variant tryptic peptide of known human Hb variants. The experimental results (full MS and MS/MS spectra) are correlated with theoretical mass spectra generated from our in-house-built variant peptide database (Hbp) using the SEQUEST algorithm. Simple preparation of samples and an automated identification of the variant peptide are the main characteristics of this approach, making it an attractive method for the detection of Hb variants at the routine clinical level. We have analyzed 16 different samples, each containing a different known variant of hemoglobin.  相似文献   

14.
The recent development of high-throughput proteomic technologies has given us new methods to analyze how an organism responds to changes in its nutritional environment. The analysis of plasma samples by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) was investigated as a novel approach to the identification of new biomarkers of nutrient status. Pre-fractionation of rat plasma by anion-exchange chromatography in 96-well filter plates markedly increased the total number of unique peptides and proteins that could be observed in SELDI-TOF mass spectra. Replicate fractionations generated nearly identical pH fractions, not only in terms of peptide and protein composition but also in respect to the ion signal intensity of replicate SELDI-TOF mass spectra. The feasibility of this approach was tested with samples from retinol-sufficient and retinol-deficient rats. The comparative analysis revealed reduced levels of three proteins with molecular masses between 10,000 and 20,000 in plasma of retinol-deficient rats. These results demonstrate that plasma profiling by anion-exchange fractionation and SELDI-TOF-MS may be a promising surveillance tool to detect changes in nutritional status and whole body physiology.  相似文献   

15.
A method has been developed for the simultaneous determination of antifouling pesticides and some of their degradation products, e.g. dichlofluanid, diuron, demethyldiuron, 1-(3,4-dichlorophenyl)urea, sea-nine, Irgarol 1051 and one of its metabolites (2-methylthio-4-tert-butylamino-s-triazine) in marine sediments. The determination of these compounds in sediment samples was performed by means of methanolic ultrasonic extraction then clean-up on an Isolute ENV+ solid phase extraction (SPE) cartridge. The resulting extract was then analyzed by reversed-phase high-performance liquid chromatography coupled with atmospheric-pressure chemical-ionization mass spectrometry in negative and positive ion modes (HPLC–APCI–MS). Recovery ranged from 54–109% for the antifouling agents and their degradation products. The determination limits for the different compounds varied between 0.2 and 1.6 μg kg–1 dry sediment. The analytical procedure was successfully applied to the determination of these pesticides and their degradation products in marine sediment samples from different marinas of the Catalan coast. The compounds detected were: diuron, dichlofluanid, demethyldiuron, sea-nine, and Irgarol 1051. The highest concentrations were those of diuron and Irgarol 1051 – 136 and 88 μg kg–1, respectively.  相似文献   

16.
In this study, a simple, fast, and cheap sample preparation procedure for the analysis of three well-known representatives of perfluoroalkyl substances (perfluorooctane sulfonate, perfluorooctanoic acid, and perfluorooctane sulfonamide) was validated in accordance with Commission Decision 2002/657/EC. The method was based on extraction with methanol followed by a dispersive solid phase extraction cleanup step by addition of activated charcoal for fish tissue, fish feed, and milk samples. The novel analytical approach combined with liquid chromatography–tandem mass spectrometry makes it possible to achieve limits of quantification below 1 μg/kg (defined by Commission Recommendation 2010/161/EU). This method provides a high laboratory sample throughput: ten samples in 60 min. The validated procedure was successfully verified in an interlaboratory study.  相似文献   

17.
A simple, reliable and sensitive liquid chromatography tandem mass spectrometry (LC‐MS/MS) protocol was developed and validated for quantification of bisoprolol in human plasma. The sample was pretreated with a simple procedure of protein precipitation and an isotope‐labeled d5‐bisoprolol was used as internal standard. The chromatographic separation was performed on a Capcell Pak C18 MG III column (100 mm × 2.0 mm, 5 µm). The protonated ion of the analyte was detected in positive ionization by multiple reaction monitoring mode. The mass transition pairs of m/z 326.3 → 116.3 and m/z 331.3 → 121.3 were used to detect bisoprolol and the internal standard, respectively. Linearity, accuracy, precision, recovery, matrix effect, dilution test and stability were evaluated during method validation over the range of 0.5–100 ng/mL. The validated method was successfully applied to analyze human plasma samples in a bisoprolol bioavailability study. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
The application of inductively coupled plasma – time-of-flight mass spectrometry for the speciation analysis of organolead compounds in environmental waters is described. Construction of the transfer line was achieved by means of a relatively simple and rapid coupling procedure. Derivatization of the ionic lead species was achieved by in-situ propylation with sodium tetrapropylborate; simultaneous extraction of the derivatized compounds in hexane was followed by separation and detection by capillary gas chromatography hyphenated to inductively coupled plasma–time-of-flight mass spectrometry. Detection limits for the different organolead species ranged from 10 to 15 fg (as Pb), corresponding to procedural detection limits between 50 and 75 ng L–1, on the basis of a 50 mL snow sample, extraction with 200 μL hexane, and subsequent injection of 1 μL of the organic extract on to the column. The accuracy of the system was confirmed by additional analysis of the water samples by capillary gas chromatography coupled with microwave-induced plasma–atomic-emission spectrometry and the analysis of a standard reference material CRM 605 (road dust) with a certified content of trimethyllead.  相似文献   

19.
This paper focuses on the development of a novel approach to analyze underivatized fatty acids in human plasma. The method is based on liquid–liquid extraction followed by reversed phase liquid chromatography coupled to direct-electron ionization mass spectrometry (LC-Direct-EI-MS). The assay is validated. Calibrations show satisfactory linearity and precision in the investigated range of linearity. Recoveries span from 75% to 104%. The method limits of detection, varying from 0.53 to 5.35 μM, are satisfactory for the quantitation of non-esterified fatty acids (NEFAs) in plasma at physiological levels. The method has been successfully applied to the NEFAs profiling of plasma samples from healthy adult volunteers and subjects affected by diabetes mellitus. Compared with published protocols based on gas chromatography–mass spectrometry and liquid chromatography coupled to electrospray ionization mass spectrometry, this method does not require derivatization and does not show matrix effects, thus simplifying sample preparation procedure and reducing the total time of analysis to approximately 90 min. In addition, Direct-EI-MS allows the acquisition of high-quality NIST library-matchable EI spectra, allowing an easy-to-obtain identification of the target NEFAs.  相似文献   

20.
A simple plasma extraction method coupled with liquid chromatography–tandem mass spectrometry (LC/MS/MS) detection was developed and validated for the analysis of endogenous mevalonic acid (MVA), a biomarker indicative of the rate of cholesterol biosynthesis, in human plasma samples. The analyte was extracted from the plasma matrix using a straightforward liquid–liquid sample preparation procedure. The extract supernatants were evaporated, reconstituted in aqueous solvent and injected into the LC/MS/MS system without further processing. The chromatographic separation was achieved on a reverse‐phase high‐performance liquid chromatography column. The accuracy and precision of the method was determined over the concentration range 0.25–25 ng/mL MVA from human plasma extracts in three validation batch runs. Inter‐assay precision (%CV) and accuracy (%RE) of the quality control samples were ≤7.00% (at lower limit quality control) and ≤6.10%, respectively. The sensitivity and throughput of this assay was significantly improved relative to previously published methods, resulting in smaller sample requirements and shorter analysis time. Assay results from a clinical study following the oral administration of an exploratory statin demonstrate that this procedure could potentially be used in the investigation of therapies associated with hypercholesterolemia. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号