首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 843 毫秒
1.
A high‐throughput LC–MS/MS bioanalytical method was developed and validated for the determination of hydrocortisone in mouse serum via supported liquid extraction (SLE) in a 96‐well plate format. Although sample extracts from SLE result in similar matrix effects compared with conventional liquid–liquid extraction (LLE), greater analyte extraction recovery and much higher analysis throughput for the quantitative analysis of hydrocortisone in mouse serum were obtained. The current LC‐MS/MS method was validated for a concentration range of 2.00–2000 ng/mL for hydrocortisone using a 0.100 mL volume of mouse serum. The intra‐ and inter‐day precision and accuracy of the quality control samples at low, medium and high concentration levels showed ≤12.9% CV and ?3.4–6.2% bias for the analyte in mouse serum. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography–tandem mass spectrometry (LC‐MS/MS) was developed. This assay represents the first LC‐MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3‐atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/mL and 10 nm for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3–900 ng/mL and 10 nm to 10 µm for human plasma and cellular samples, respectively (r2 > 0.999). The intra‐ and inter‐day assay accuracy and precision were evaluated using quality control samples at three different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect and recovery were also successfully demonstrated. The present assay is superior to previously published LC‐MS and LC‐MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
Metformin is a well‐known oral antihyperglycemic drug used in treatment of type II diabetes. Analysis of metformin in biological fluids is a challenge owing to its high polarity and small molecular size, which lead to poor retention of metformin on reversed‐phase liquid chromatographic columns. A high‐throughput method was developed and validated for the determination of metformin in rat plasma in support of preclinical toxicology studies, using hydrophilic interaction liquid chromatography tandem mass spectrometry (HILIC‐MS/MS) and Tecan automated sample preparation. Extracted samples were directly injected onto the unbounded silica column with an aqueous–organic mobile phase. This HILIC‐MS/MS method was validated for accuracy, precision, sensitivity, stability, matrix effect, recovery and calibration range. Acceptable intra‐run and inter‐run assay precision (coefficient of variation ≤ 3.9%) and accuracy (99.0–101.8%) were achieved over a linear range of 50–50,000 ng/mL. Metformin is stable in rat plasma for at least 6 h at room temperature, 147 days at ?70°C and through three freeze (?70°C) and thaw cycles. Metformin is also stable in rat whole blood for at least 2 h at room temperature and in an ice–water bath. The validated method was successfully used in support of several preclinical studies where metformin is dosed together with an investigational drug substance. The ruggedness of the validated method was demonstrated by the incurred sample reproducibility test. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
A sensitive and specific method based on liquid chromatography‐tandem mass spectrometry using electrospray ionization (LC‐ESI‐MS/MS) has been developed for the determination of Schisandrin and Schisandrin B in rat plasma. A 100 μL plasma sample was extracted by methyl tert‐butyl ether after spiking the samples with nimodipine (internal standard) and performed on an XTerra®MS‐C18 column (150 mm × 2.1 mm, 3.5 μm) with the mobile phase of acetonitrile–water–formic acid (80:20:0.2, v/v) at a flow rate of 0.2 mL/min in a run time of 8.5 min. The lower limit of quantification of the method was 40 ng/mL for Schisandrin and 20 ng/mL for Schisandrin B. The method showed reproducibility with intra‐day and inter‐day precision of less than 13.8% RSD, as well as accuracy, with inter‐ and intra‐assay accuracies between 93.5 and 107.2%. Finally, the LC‐ESI‐MS/MS method was successfully applied to study the pharmacokinetics of Schisandrin and Schisandrin B in rats after administration of Wurenchun commercial formulations to rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
Complementary and alternative medicines (CAM) can affect the pharmacokinetics of anticancer drugs by interacting with the metabolizing enzyme cytochrome P450 (CYP) 3A4. To evaluate changes in the activity of CYP3A4 in patients, levels of 1‐hydroxymidazolam in plasma are often determined with liquid chromatography–quadrupole mass spectrometry (LC‐MS/MS). However, validated LC‐MS/MS methods to determine in vitro CYP3A4 inhibition in human liver microsomes are scarce and not optimized for evaluating CYP3A4 inhibition by CAM. The latter is necessary because CAM are often complex mixtures of numerous compounds that can interfere with the selective measurement of 1‐hydroxymidazolam. Therefore, the aim was to validate and optimize an LC‐MS/MS method for the adequate determination of CYP3A4 inhibition by CAM in human liver microsomes. After incubation of human liver microsomes with midazolam, liquid–liquid extraction with tert‐butyl methyl ether was applied and dried samples were reconstituted in 50% methanol. These samples were injected onto a reversed‐phase chromatography consisting of a Zorbax Extend‐C18 column (2.1 × 150 mm, 5.0 µm particle size), connected to a triple quadrupole mass spectrometer with electrospray ionization. The described LC‐MS/MS method was validated over linear range of 1.0–500 nm for 1‐hydroxymidazolam. The results revealed good inter‐assay accuracy (≥85% and ≤115%) and within‐day and between‐day precisions (coefficient of variation ≤ 4.43%). Furthermore, the applicability of this assay for the determination of CYP3A4 inhibition in complex matrix mixtures was successfully demonstrated in an in vitro experiment in which CYP3A4 inhibition by known CAM (β‐carotene, green tea, milk thistle and St. John's wort) was determined. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
A sensitive, selective and rapid liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed for the quantification of gypenoside XLIX, a naturally occurring gypenoside of Gynostemma pentaphyllum in rat plasma and then validated according to the US Food and Drug Administration's Guidance for Industry: Bioanalytical Method Validation . Plasma samples were prepared by a simple solid‐phase extraction. Separation was performed on a Waters XBridgeTM BEH C18 chromatography column (4.6 × 50 mm, 2.5 μm) using a mobile phase of acetonitrile and water (62.5:37.5, v /v). Gypenoside XLIX and the internal standard gypenoside A were detected in the negative ion mode using selection reaction monitoring of the transitions at m/z 1045.6 → 913.5 and 897.5 → 765.4, respectively. The calibration curve was linear (R 2 > 0.990) over a concentration range of 10–7500 ng/mL with the lower quantification limit of 10 ng/mL. Intra‐ and inter‐day precision was within 8.6% and accuracy was ≤10.2%. Stability results proved that gypenoside XLIX and the IS remained stable throughout the analytical procedure. The validated LC–MS/MS method was then applied to analyze the pharmacokinetics of gypenoside XLIX after intravenous administration to rats (1.0, 2.0 and 4.0 mg/kg).  相似文献   

7.
A simple, rapid and sensitive liquid chromatography–tandem mass spectrometric (LC‐MS/MS) assay method has been developed and validated for simultaneous quantification of sitagliptin and simvastatin in human plasma. Carbamazepine was used as an internal standard (IS). The analytes and IS were extracted from the human plasma by liquid–liquid extraction technique. The reconstituted samples were chromatographed on an Alltima HP C18 column using an isocratic solvent mixture [acetonitrile–5 mm ammonium acetate (pH 4.5), 85:15 (v/v)] at a flow rate of 1.0 mL/min. Method validation was performed as per Food and Drug Administration guidelines and the results met the acceptance criteria. The calibration curves obtained were linear (r2 ≥ 0.99) over the concentration range of 0.10–501 and 0.05–105 ng/mL for sitagliptin and simvastatin, respectively. The results of the intra‐ and inter‐day precision and accuracy studies were well within the acceptable limits. Both the analytes were found to be stable in a battery of stability studies. The method is precise and sensitive enough for its intended purpose. A run time of 3.0 min for each sample made it possible to analyze more than 300 plasma samples per day. The developed assay was successfully applied to a pharmacokinetic study in human volunteers. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

8.
A rapid, sensitive and rugged solid‐phase extraction ultraperformance liquid chromatography tandem mass spectrometry (LC‐MS/MS) method was developed for determination of oseltamivir phosphate (OP) and oseltamivir carboxylate (OC) in human plasma. The procedure for sample preparation includes a simple SPE extraction procedure coupled with a Chromatopack C18 column (50 × 3.0 mm, i.d., 3.0 µm) with isocratic elution at a flow‐rate of 0.600 mL /min and acyclovir was used as the internal standard. The analysis was performed on a triple‐quadrupole tandem mass spectrometer by multiple reaction monitoring mode via electrospray ionization. Using 500 µL plasma, the methods were validated over the concentration ranges 0.92–745.98 and 5.22–497.49 ng/mL for OP and OC, with a lower limit of quantification of 0.92and 5.22 ng/mL. The intra‐ and inter‐day precision and accuracy of the quality control samples were within 10.1%. The recovery was 68.72, 70.66 and 71.59% for OP, OC and IS, respectively. Total run time was only 1.0 min. The method was highly reproducible with excellent chromatography properties. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
The authors proposed a sensitive, selective and rapid liquid chromatography–tandem mass spectrometric (LC‐MS/MS) assay procedure for the quantification of lurasidone and its active metabolite, i.e. ID‐14283 in human plasma simultaneously using corresponding isotope labeled compounds as internal standards as per regulatory guidelines. After liquid–liquid extraction with tert‐butyl methyl ether, the analytes were chromatographed on a C18 column using an optimized mobile phase composed of 5 mm ammonium acetate (pH 5.0) and acetonitrile (15:85, v/v) and delivered at a flow rate of 1.00 mL/min. The assay exhibits excellent linearity in the concentration ranges of 0.25–100 and 0.10–14.1 ng/mL for lurasidone and ID‐14283, respectively. The precision and accuracy results over five concentration levels in four different batches were well within the acceptance limits. Lurasidone and ID‐14283 were found to be stable in battery of stability studies. The method was rapid with the chromatographic run time 2.5 min, which made it possible to analyze 300 samples in a single day. Additionally, this method was successfully used to estimate the in vivo plasma concentrations of lurasidone and ID‐14283 obtained from a pharmacokinetic study in south Indian male subjects and the results were authenticated by conducting incurred samples reanalysis. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
A liquid chromatography–triple quadrupole mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of 5‐nitro‐5′‐hydroxy‐indirubin‐3′‐oxime (AGM‐130) in human plasma to support a microdose clinical trial. The method consisted of a liquid–liquid extraction for sample preparation and LC‐MS/MS analysis in the positive ion mode using TurboIonSprayTM for analysis. d3‐AGM‐130 was used as the internal standard. A linear regression (weighted 1/concentration) was used to fit calibration curves over the concentration range of 10–2000 pg/mL for AGM‐130. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 96.6% with a precision (coefficient of variation, CV) of 4.4%. For quality control samples at 30, 160 and 1600 pg/mL, the between run CV was ≤5.0 %. Between‐run accuracy ranged from 98.1 to 101.0%. AGM‐130 was stable in 50% acetonitrile for 168 h at 4°C and 6 h at room temperature. AGM‐130 was also stable in human plasma at room temperature for 6 h and through three freeze–thaw cycles. The variability of selected samples for the incurred sample reanalysis was ≤12.7% when compared with the original sample concentrations. This validated LC‐MS/MS method for determination of AGM‐130 was used to support a phase 0 microdose clinical trial. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
Isoginkgetin is a biflavonoid compound isolated from the leaf extracts of Ginkgo biloba. In this study, an liquid chromatography–tandem mass spectrometry (LC/MS/MS) with liquid–liquid extraction was developed and validated for the analysis of isoginkgetin in rat plasma. In the process of chromatographic separation, selected reaction monitoring transitions for isoginkgetin and IS were m/z 566.8 → 134.7 and m/z 430.8 → 269.3, respectively. The validation parameters including selectivity, linearity, LLOQ, accuracy, precision, matrix effect, stability and recovery were satisfactory. The intra‐ and inter‐batch precision (RSD) were <12.1% in plasma, while the accuracy (RE) was within ±14.3%. This method was employed in a pharmacokinetic study on rats after the intravenous administration of isoginkgetin.  相似文献   

12.
A high‐throughput, sensitive, and rugged liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for the rapid quantitation of β ‐hydroxy‐β ‐methylbutyrate (HMB) in human plasma has been developed and validated for routine use. The method uses 100 μL of plasma sample and employs protein precipitation with 0.1% formic acid in methanol for the extraction of HMB from plasma. Sample extracts were analyzed using LC–MS/MS technique under negative mode electrospray ionization conditions. A 13C–labeled stable isotope internal standard was used to achieve accurate quantitation. Multiday validation was conducted for precision, accuracy, linearity, selectivity, matrix effect, dilution integrity (2×), extraction recovery, freeze–thaw sample stability (three cycles), benchtop sample stability (6 h and 50 min), autosampler stability (27 h) and frozen storage sample stability (146 days). Linearity was demonstrated between 10 and 500 ng/mL. Inter‐day accuracies and coefficients of variation (CV) were 91.2–98.1 and 3.7–7.8%, respectively. The validated method was proven to be rugged for routine use to quantify endogenous levels of HMB in human plasma obtained from healthy volunteers.  相似文献   

13.
For sample assay to support global clinical studies of perampanel, a novel AMPA receptor antagonist, six chromatographic assay methods in human plasma were developed and fully validated at each laboratory using liquid chromatography with tandem mass spectrometry (LC‐MS/MS) or LC with fluorescence detection (LC‐FL). In this study, samples fortified with known perampanel concentrations were assayed at six laboratories to find whether assay data are comparable. Perampanel was extracted by protein precipitation or liquid–liquid extraction, chromatographed on a reverse‐phase column then detected by MS/MS or FL to achieve the limit of quantification of 0.25 or 1 ng/mL. Cross‐validation samples at four concentrations prepared at a central laboratory were determined at six laboratories and the mean accuracy at each concentration was within ±15% except the low concentration at one laboratory (relative error ?17.4%), suggesting that plasma concentrations of perampanel in clinical trials can be compared across laboratories.  相似文献   

14.
A rapid and sensitive high‐performance liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated to quantify tilmicosin in pig plasma. Plasma samples were prepared by liquid–liquid extraction. Chromatographic separation was achieved on a C18 column (2.1 × 30 mm, 3.5 μm) using acetonitrile–water (90:10, v /v; water included 0.1% formic acid) as the mobile phase. Mass detection was carried out using positive electrospray ionization in multiple reaction monitoring mode. The calibration curve was linear from 0.5 to 2000 ng/mL (r 2 = 0.9998). The intra‐ and inter‐day accuracy and precision were within the acceptable limits of ±10% for all tilmicosin concentrations. The recoveries ranged from 95 to 99% for the three tested concentrations. The LC–MS/MS method described herein was simple, fast and less laborious than other methods, achieved high sensitivity using a small sample volume, and was successfully applied to pharmacokinetic studies of tilmicosin enteric granules after oral delivery to pigs. In comparison with tilmicosin premix, tilmicosin enteric granules slowed the elimination rate of tilmicosin, prolonged its period of action and significantly improved its bioavailability.  相似文献   

15.
A rapid and sensitive liquid chromatography–tandem mass spectrometric (LC‐MS/MS) assay method has been developed and fully validated for simultaneous quantification of donepezil and its active metabolite, 6‐o‐desmethyl donepezil in human plasma. Analytes and the internal standard were extracted from human plasma by liquid–liquid extraction technique using a 30:70 v/v mixture of ethyl acetate and n‐hexane. The reconstituted samples were chromatographed on a C18 column by using a 70:30 v/v mixture of acetonitrile and ammonium formate (5 mm , pH 5.0) as the mobile phase at a flow rate of 0.6 mL/min. The calibration curve obtained was linear (r ≥ 0.99) over the concentration range of 0.09–24.2 ng/mL for donepezil and 0.03–8.13 ng/mL for 6‐o‐desmethyl donepezil. The results of the intra‐day and inter‐day precision and accuracy studies were well within the acceptable limits. The proposed method was successfully applied for the estimation of the drug in real time plasma samples for pharmacokinetic studies. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for the determination of GDC‐0425 concentrations in human plasma has been developed and validated. Supported liquid extraction was used to extract plasma samples (50 μL) and the resulting samples were analyzed using reverse‐phase chromatography and mass spectrometry coupled with a turbo‐ionspray interface. The mass analysis of GDC‐0425 was performed using multiple reaction monitoring transitions in positive ionization mode. The method was validated over the calibration curve range of 1.00–1000 ng/mL using linear regression and 1/x2 weighting. Within‐run relative standard deviation ranged from 0.8 to 5.1%, while between‐run RSD varied from 1.9 to 4.7% for QCs. The accuracy ranged from 90.0 to 101.0% of nominal for within‐run and from 94.0 to 100.0% of nominal for between‐run. Overall extraction recovery was 87.4% for GDC‐0425 and 87.9% for GDC‐0425‐d9. Stability of GDC‐0425 was established in human plasma for 374 days at ?20 and ?70 °C and established in reconstituted sample extracts for 88 h when stored at 2–8 °C. Stable‐labeled internal standard was used to minimize matrix effects. This assay was used to characterize the pharmacokinetics of GDC‐0425 in cancer patients.  相似文献   

17.
A rapid, simple, sensitive and specific LC‐MS/MS method has been developed and validated for the simultaneous estimation of atorvastatin (ATO), amlodipine (AML), ramipril (RAM) and benazepril (BEN) using nevirapine as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under the multiple‐reaction monitoring mode using electrospray ionization. Analytes and IS were extracted from plasma by simple liquid–liquid extraction technique using ethyl acetate. The reconstituted samples were chromatographed on C18 column by pumping 0.1% formic acid–acetonitrile (15:85, v/v) at a flow rate of 1 mL/min. A detailed validation of the method was performed as per the FDA guidelines and the standard curves were found to be linear in the range of 0.26–210 ng/mL for ATO; 0.05–20.5 ng/mL for AML; 0.25–208 ng/mL for RAM and 0.74–607 ng/mL for BEN with mean correlation coefficient of ≥0.99 for each analyte. The intra‐day and inter‐day precision and accuracy results were well with in the acceptable limits. A run time of 2.5 min for each sample made it possible to analyze more than 400 human plasma samples per day. The developed assay method was successfully applied to a pharmacokinetic study in human male volunteers. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
JCC76 is a novel nimesulide analog that selectively inhibits the human epidermal growth factor receptor 2 (HER2) overexpressing breast cancer cell proliferation and tumor progression. To support further pharmacological and toxicological studies of JCC76, a novel and rapid method using liquid chromatography and electrospray ionization tandem mass spectrometry (LC‐ESI‐MS/MS) has been developed and validated for the quantification of the compound in rat plasma. A C18 column was used for chromatographic separation, and the mobile phase was aqueous ammonium formate (pH 3.7; 5 mm )–methanol (1:9, v/v) with an isocratic elution. With a simple liquid–liquid extraction procedure using the mixture of methyl tert‐butyl ether–hexane (1:2, v/v), the mean extraction efficiency of JCC76 in rat plasma was determined as 89.5–97.3% and no obvious matrix effect was observed. This method demonstrated a linear calibration range from 0.3 to 100 ng/mL for JCC76 in rat plasma and a small volume of sample consumption. The intra‐ and inter‐assay accuracy and precision were within ±10%. The pharmacokinetics of JCC76 was also profiled using this validated method in rats. In conclusion, this rapid and sensitive method has been proven to effectively quantify JCC76 for pharmacokinetics study. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
This paper presents the multiresidue determination of the series of quinolones regulated by the European Union (marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, sarafloxacin, difloxacin, oxolinic acid and flumequine) in bovine and porcine plasma using capillary electrophoresis and liquid chromatography with ultraviolet detection (CE‐UV, LC‐UV), liquid chromatography–mass spectrometry and –tandem mass spectrometry (LC‐MS, LC‐MS/MS) methods. These procedures involve a sample preparation by solid‐phase extraction for clean‐up and preconcentration of the analytes before their injection into the separation system. All methods give satisfactory results in terms of linearity, precision, accuracy and limits of quantification. The suitability of the methods to determine quinolones was evaluated by determining the concentration of enrofloxacin and ciprofloxacin in real samples from pig plasma and cow plasma. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
The prerequisites for forensic confirmatory analysis by LC/MS/MS with respect to European Union guidelines are chromatographic separation, a minimum number of two MS/MS transitions to obtain the required identification points and predefined thresholds for the variability of the relative intensities of the MS/MS transitions (MRM transitions) in samples and reference standards. In the present study, a fast, sensitive and robust method to quantify tramadol, chlorpheniramine, dextromethorphan and their major metabolites, O‐desmethyltramadol, dsmethyl‐chlorpheniramine and dextrophan, respectively, in human plasma using ibuprofen as internal standard (IS) is described. The analytes and the IS were extracted from plasma by a liquid–liquid extraction method using ethyl acetate–diethyl‐ether (1:1). Extracted samples were analyzed by ultra‐high‐performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (UHPLC‐ESI‐MS/MS). Chromatographic separation was performed by pumping the mobile phase containing acetonitrile, water and formic acid (89.2:11.7:0.1) for 2.0 min at a flow rate of 0.25 μL/min into a Hypersil‐Gold C18 column, 20 × 2.0 mm (1.9 µm) from Thermoscientific, New York, USA. The calibration curve was linear for the six analytes. The intraday precision (RSD) and accuracy (RE) of the method were 3–9.8 and ?1.7–4.5%, respectively. The analytical procedure herein described was used to assess the pharmacokinetics of the analytes in 24 healthy volunteers after a single oral dose containing 50 mg of tramadol hydrochloride, 3 mg chlorpheniramine maleate and 15 mg of dextromethorphan hydrobromide. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   