首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The oxidative behaviour of the antidiabetic agent glibenclamide on a bare carbon paste electrode (CPE) and a Sephadex-modified carbon paste electrode (SMCPE) was explored by cyclic and differential pulse voltammetry (DPV). The analysis procedure consisted of an open circuit accumulation step in stirred sample solution of Britton-Robinson buffer (0.04 mol L–1, pH 2.0). This was followed by medium exchange to a clean solution of Britton-Robinson buffer (0.04 mol L–1, pH 5.0), and subsequently an anodic potential scan was effected to obtain the voltammetric peak. The glibenclamide oxidation peak current obtained by DPV was proportional to the concentration of the glibenclamide in the range of 1.0×10–9 mol L–1 to 5.0×10–8 mol L–1 for 180 s accumulation time, with a detection limit of 4.0×10–10 mol L–1. A method was developed for the determination of glibenclamide in formulation and spiked human serum. Moreover, the proposed procedure was used to estimate the serum concentrations after oral administration of a 5 mg tablet of glibenclamide to three diabetic subjects.  相似文献   

2.
A sensitive procedure for determination of micro-traces of Co(II) by adsorptive stripping voltammetry is proposed. The procedure exploits the enhancement of the cobalt peak obtained by use of the system Co(II)–dimethylglyoxime–piperazine-1,4-bis(2-ethanesulfonic acid)–cetyltrimethylammonium bromide. Using the optimized conditions, a detection limit (based on the 3 criterion) for Co(II) of 1.2×10–11 mol L–1 (0.7 ng L–1) was achieved. The calibration plot for an accumulation time of 30 s was linear from 5×10–11 to 4×10–9 mol L–1. The procedure was validated by analysis of certified reference materials and natural water samples.  相似文献   

3.
We report the electroanalytical determination of lead by anodic stripping voltammetry at in-situ-formed, bismuth-film-modified, boron-doped diamond electrodes. Detection limits in 0.1 mol L–1 nitric acid solution of 9.6x10–8 mol L–1 (0.2 ppb) and 1.1x10–8 mol L–1 (2.3 ppb) were obtained after 60 and 300 s deposition times, respectively. An acoustically assisted deposition procedure was also investigated and found to result in improved limits of detection of 2.6×10–8 mol L–1 (5.4 ppb) and 8.5×10–10 mol L–1 (0.18 ppb) for 60 and 300 s accumulation times, respectively. Furthermore, the sensitivity obtained under quiescent and insonated conditions increased from 5.5 (quiescent) to 76.7 A mol–1 L (insonated) for 60 s accumulation and from 25.8 (quiescent) to 317.6 A mol–1 L (insonated) for 300 s accumulation. Investigation of the use of ultrasound with diluted blood revealed detection limits of the order of 10–8 mol L–1 were achievable with excellent inter- and intra-reproducibility and sensitivity of 411.9 A mol–1 L . For the first time, electroanalytical detection of lead in diluted blood is shown to be possible by use of insonated in-situ-formed bismuth-film-modified boron-doped diamond electrodes. This method is a rapid, sensitive, and non-toxic means of clinical sensing of lead in whole human blood.  相似文献   

4.
A square-wave voltammetric (SWV) method using a hanging mercury drop electrode (HMDE) has been developed for determination of the herbicide molinate in a biodegradation process. The method is based on controlled adsorptive accumulation of molinate for 10 s at a potential of –0.8 V versus AgCl/Ag. An anodic peak, due to oxidation of the adsorbed pesticide, was observed in the cyclic voltammogram at ca. –0.320 V versus AgCl/Ag; a very small cathodic peak was also detected. The SWV calibration plot was established to be linear in the range 5.0×10–6 to 9.0×10–6 mol L–1; this corresponded to a detection limit of 3.5×10–8 mol L–1. This electroanalytical method was used to monitor the decrease of molinate concentration in river waters along a biodegradation process using a bacterial mixed culture. The results achieved with this voltammetric method were compared with those obtained by use of a chromatographic method (HPLC–UV) and no significant statistical differences were observed.  相似文献   

5.
Accumulation of selected cephalosporin antibiotics cefazolin, cefotaxime, cefuroxime and ceftriaxone on hanging mercury drop electrode was studied. The effects of supporting electrolyte composition, pH, accumulation potential and time were examined and corresponding analytical parameters were established employing linear sweep (staircase) or differential pulse voltammetric detection. Britton-Robinson buffer of pH 4.0 for ceftriaxone and acetate buffer in the pH range 3.6–5.0 for the other three compounds were found to be the best media. Calibration curves were linear from micromolar down to nanomolar range with limits of detection 2 × 10–9 moll–1, 1 × 10–9 moll–1, 5 × 10–10 moll–1 and 5 × 10–9 moll–1 for cefazolin, cefotaxime, cefuroxime and ceftriaxone respectively, applying the accumulation times of 5 to 14 min. Direct and simple determination of cefazolin as a model compound in urine was established with no other manipulation of urine sample than dilution 1 + 500 with buffer and subsequent adsorptive stripping voltammetric determination. The detection limit of the method is 7 gml–1 (1.5 × 10–5 moll–1) of cefazolin in urine, and the relative standard deviation of 9 measurements was found to be 2.8% at 23 gml–1 of cefazolin in urine. Similar values were found for other three compounds as well. These values are comparable or even better than those obtained by high performance liquid Chromatographic methods and approve the suitability of the proposed method for urine level monitoring in clinical practice and pharmacological studies.  相似文献   

6.
The polarographic characteristics of telmisartan have been investigated in 0.8 mol L–1 NH3.H2O–NH4Cl (pH 8.9)–0.01 mol L–1 H2O2 as supporting electrolyte. The results demonstrate that the polarographic reduction wave at ca. –1.30 V in the absence of H2O2 is a catalytic hydrogen wave, and the reduction wave enhanced by H2O2 is a so-called parallel catalytic hydrogen wave. The analytical sensitivity of the parallel catalytic hydrogen wave is ca. 60 times higher than that of the corresponding catalytic hydrogen wave. Based on the parallel catalytic hydrogen wave a novel method has been developed for determination of telmisartan by linear sweep polarography. The calibration curve is linear in the range 2.0×10–8–2.0×10–6 mol L–1 and the detection limit is 1.0×10–8 mol L–1. The precision is excellent with relative standard deviations of 2.6% at a concentration of 1.0×10–7 mol L–1 telmisartan. The proposed method has been applied to the direct determination of the telmisartan in capsule forms and biological samples. The proposed method has been proved to be advantageous over existing CZE and MEKC methods in simplicity, rapidity, and reproducibility.  相似文献   

7.
Electrochemical detection of hydrogen peroxide using an edge-plane pyrolytic-graphite electrode (EPPG), a glassy carbon (GC) electrode, and a silver nanoparticle-modified GC electrode is reported. It is shown, in phosphate buffer (0.05 mol L–1, pH 7.4), that hydrogen peroxide cannot be detected directly on either the EPPG or GC electrodes. However, reduction can be facilitated by modification of the glassy-carbon surface with nanosized silver assemblies. The optimum conditions for modification of the GC electrode with silver nanoparticles were found to be deposition for 1 min at –0.5 V vs. Ag from 5 mmol L–1 AgNO3/0.1 mol L–1 TBAP/MeCN, followed by stripping for 2 min at +0.5 V vs. Ag in the same solution. A wave, due to the reduction of hydrogen peroxide on the silver nanoparticles is observed at –0.68 V vs. SCE. The limit of detection for this modified nanosilver electrode was 2.0×10–6 mol L–1 for hydrogen peroxide in phosphate buffer (0.05 mol L–1, pH 7.4) with a sensitivity which is five times higher than that observed at a silver macro-electrode. Also observed is a shoulder on the voltammetric wave corresponding to the reduction of oxygen, which is produced by silver-catalysed chemical decomposition of hydrogen peroxide to water and oxygen then oxygen reduction at the surface of the glassy-carbon electrode.  相似文献   

8.
An electrochemical method for the determination of trace levels of mercury based on a multi-walled carbon nanotubes (MWNT) film coated glassy carbon electrode (GCE) is described. In 0.1 mol L–1 HCl solution containing 0.02 mol L–1 KI, Hg2+ was firstly preconcentrated at the MWNT film and then reduced at –0.60 V. During the anodic potential sweep, reduced mercury was oxidized, and then a sensitive and well-defined stripping peak at about –0.20 V appeared. Under identical conditions, a MWNT film coated GCE greatly enhances the stripping peak current of mercury in contrast to a bare GCE. Low concentrations of I remarkably improve the determining sensitivity, since this increases the accumulation efficiency of Hg2+ at the MWNT film coated GCE. The stripping peak current is proportional to the concentration of Hg2+ over the range 8×10–10–5×10–7 mol L–1. The lowest detectable concentration of Hg2+ is 2×10–10 mol L–1 at 5 min accumulation. The relative standard deviation (RSD) at 1×10–8 mol L–1 Hg2+ was about 6% (n=10). By using this proposed method, Hg2+ in some water samples was determined, and the results were compared with those obtained by atomic absorption spectrometry (AAS). The two results are similar, suggesting that the MWNT-film coated GCE has great potential in practical analysis.  相似文献   

9.
In the NH4Cl supporting electrolyte, within the pH range from 1 to 5, an irreversible adsorptive reducing wave of salicyl fluorone(SAF) was obtained. The electrode process was verified as follow: On the surface of mercury electrode, the adsorption of SAF obeys Frumkin isotherm.In 0.2 mol/l potassium hydrogen phthalate/HCl buffer solution, at pH 3.0, the sensitive adsorptive complex wave of Ga-SAF was obtained by linear sweep voltammetry. The composition of the electroactive complex was determined as Ga:SAF = 11. The peak height of the complex is proportional to the concentration of Ga(III) in the range of 1.5 × 10–9 to 6.0 × 10–7 mol/l, the detection limit is 1.0× 10–9 mol/l. The proposed method has been applied to the determination of gallium content in aluminium alloys.  相似文献   

10.
Dimenhydrinate exhibits a single adsorptive stripping peak at a hanging mercury drop electrode after accumulation at 0.0V vs Ag/AgCl electrode at pH 3.8 (acetate buffer). The addition of trace amounts of copper ions enhanced the dimenhydrinate peak and its height depends on the concentration of each dimenhydrinate and Cu2+. The adsorptive stripping response was evaluated with respect to accumulation time and potential, concentration dependence, electrolyte, the presence of other purines, surfactants and other metal ions, and some variables. The calibration graph for dimenhydrinate determination is linear over the range 2.0×10–8–2.0×10–7 M (pre-concentration for 60s). The correlation factor is found to be 0.985 and RSD is 3.2% at 1.0×10–7 M. Detection limit is 1.0×10–8 M after 5 min accumulation. The determination of dimenhydrinate in pharmaceutical formulations by the proposed method is also reported.  相似文献   

11.
Procedures for trace cobalt determinations by adsorptive stripping voltammetry at in situ and ex situ plated bismuth film electrodes are presented. These exploit the enhancement of the cobalt peak obtained by using the Co(II)–dimethylglyoxime–cetyltrimethylammonium bromide–piperazine-N,N-bis(2-ethanesulfonic acid) system. The calibration graph for an accumulation time of 120 s was linear from 2 × 10–10 to 2 × 10–8 mol L–1. The relative standard deviation from five determinations of cobalt at a concentration of 5 × 10–9 mol L–1 was 5.2%. The detection limit for an accumulation time of 300 s was 1.8 × 10–11 mol L–1. The proposed procedure was applied to cobalt determination in certified reference materials and in tap and river water samples.  相似文献   

12.
Summary Accumulation voltammetry of copper(II) was investigated with a carbon-paste electrode containing salicylideneamino-2-thiophenol(SATP). Copper(II) was accumulated as the copper(II)-SATP complex on the electrode without an applied potential by immersing the electrode in 0.01 mol/l acetate buffer (pH 3.8) containing copper(II). The reduction peak of the copper(II)-SATP complex was observed at –0.12 V (vs. SCE) in 0.01 mol/l acetate buffer (pH 3.8) by scanning the potential in a negative direction. The calibration curve for copper(II) was linear in the range of 2×10–9–1×10–7 mol/l. Since the accumulation of copper(II) is based on a chemical reaction between copper(II) and SATP, copper(II) was selectively accumulated on the electrode. The presented method was applied to the determination of copper(II) in standard reference materials prepared by the National Institute for Environmental Studies.  相似文献   

13.
A novel solvent polymeric membrane electrode based on bis(1,3,4-thiadiazole) complexes of Hg(II) is described which has excellent selectivity and sensitivity toward iodide ion. The electrode, containing 1,4-bis(5-methyl-1,3,4-thiadiazole-2-yl-thio)butanemercury(II) [Hg(II)BMTB(NO3)4], has a Nernstian potentiometric response from 2.0×10–8 to 2.0×10–2 mol L–1 with a detection limit of 8.0×10–9 mol L–1 and a slope of –59.0±0.5 mV/decade in 0.01 mol L–1 phosphate buffer solution (pH 3.0, 20°C). The selectivity sequence observed is iodide>bromide>thiocyanate>nitrite>nitrate>chloride>perchlorate>acetate>sulfate. The selectivity behavior is discussed in terms of the UV–Vis spectrum, and the process of transfer of iodide across the membrane interface is investigated by use of the AC impedance technique. The electrode was successfully applied to the determination of iodide in Jialing River and Spring in Jinyun Mountains, with satisfactory results.  相似文献   

14.
Guanine is determined at the 5.0×10–10 –2.0×10–7 mol/l level by differential-pulse adsorptive stripping voltammetry at a hanging mercury drop electrode using the reduction peak of its copper (II) complex at –0.21 V vs. Ag-AgCl electrode. The optimum analytical conditions were found to be Britton-Robinson buffer solution (pH 4.8), an accumulation potential of 0.0 V and an accumulation time of 3 min. Under these conditions, the detection limit is 5.0×10–10 mol/l and the relative standard deviation 2.6% for 1.0×10–7 mol/l guanine. The method is compared with the previous voltammetric methods. The presence of some purine derivatives does not interfere.  相似文献   

15.
A carbon paste electrode incorporating silica (Si-MCPE) was fabricated to accumulate Metamitron at the electrode surface. Several electroanalytical techniques were used to explore its reductive behaviour. The results indicate that the system is irreversible and fundamentally controlled by adsorption. The adsorptive stripping response has been evaluated with respect to accumulation time, deposition potential, scan rate, pH and other variables, using differential pulse voltammetry (DPV) and square wave voltammetry (SWV) as redissolution techniques. In both cases a voltammetric peak is obtained, at –0.542 V (DPV) and –0.421 V (SWV) in Britton-Robinson buffer (pH 1.9). The detection limits were 3.66 × 10–1 M and 4.22 × 10–9 M for AdS-DPV and AdS-SWV, respectively. Under optimum conditions the Metamitron reduction peak gave two linear regions in the range from 4.0 × 10–9 M to 8.0 × 10–8 M by means of AdS-DPV, with a coefficient of variation of 2.19% (n = 10) for 1 × 10–8 M herbicide solution. A method was developed for determination of Metamitron in soils, with a recovery of 98.8% and a coefficient of variation of 5.26% (0.01 g/g of soil).  相似文献   

16.
A stable quercetin–thioglycolic acid-modified gold electrode (Qu–TCA/Au) was prepared as a self-assembled monolayer (SAM) and its electrochemical behavior was investigated by electrochemical methods. In 0.05-M phosphate buffer solution (pH 7.0) quercetin exhibits quasi-reversible signals at the Qu–TCA/Au electrode. The stability of the quercetin-modified gold electrode is very good. The quercetin self-assembled monolayer is an effective mediator for the oxidation of dopamine, which was investigated by cyclic voltammetry and differential pulse voltammetry. Ascorbic acid does not interfere with determination of dopamine at an electrode modified with a mixture of quercetin–thioglycolic acid and quercetin–11-mercaptoundecanoic acid. This modification allows dopamine to be determined in the presence of ascorbic acid in the range from 3×10–5 to 3×10–4 M. The detection limit is 1×10–6 M. Scanning electrochemical microscopy (SECM) was employed to study the electrochemical performances of the modified gold electrode indicating different feedback modes at differently modified surfaces.  相似文献   

17.
A flow-injection ultrafiltration sampling chemiluminescence system for on-line determination of cimetidine–bovine serum albumin (BSA) interaction is proposed in this paper. Cimetidine can be oxidized by N-bromosuccinimide (NBS) and sensitized by fluorescein to produce high chemiluminescence emission in basic media. The concentration of cimetidine is linear with the CL intensity in the range 3×10–7–1×10–4 mol L–1 with a detection limit of 1×10–7 mol L–1 (3). The drug and protein were mixed in different molar ratios in 0.067 mol L–1 phosphate buffer, pH 7.4, and incubated at 37 °C in a water bath. The ultrafiltration probe was utilized to sample the mixed solution at a flow rate of 5 µL min–1. The data obtained by the proposed ultrafiltration flow-injection chemiluminescence method was analyzed with Scrathard analysis and a Klotz plot. The estimated association constant (K) and the number of the binding site (n) on one molecule of BSA by Scrathard analysis and Klotz plot were 3.15×104 L mol–1 and 0.95, 3.25×104 L mol–1 and 0.92, respectively. The proposed system proved that flow-injection chemiluminescence analysis coupled with on-line ultrafiltration sampling is a simple and reliable technique for the study of drug–protein interaction.  相似文献   

18.
A simple capillary zone electrophoresis (CZE) method has been developed for analyzing seven nonsteroidal anti-inflammatory drugs (NSAIDs)—sulindac (SU), ketoprofen (KE), indomethacin (IN), piroxicam (PI), nimesulide (NI), ibuprofen (IB), and naproxen (NA). The separation was run using borate buffer (60 mmol L–1, pH 8.5) containing 13% (v/v) methanol at 20 kV, and detected at 200 nm. Several conditions were studied, including concentration and pH of borate buffer, methanol percentage, and separation voltage. In method validation, the calibration plots were linear over the range 40.0–500.0 mol L–1. In intra-day and inter-day analysis, relative standard deviations (RSD) and relative errors (RE) were all less than 5%. The limits of detection were 10 mol L–1 for SU, IN, PI, and 20 mol L–1 for KE, NI, IB, NA (S/N = 3, sampling 6 s by pressure). All recoveries were greater than 95%. This method was applied to the quality control of six NSAIDs in pharmaceuticals using NI as internal standard (IS). The assay results were within the labeled amount required by USP 25.  相似文献   

19.
This work describes an electroanalytical investigation of dopamine using cyclic voltammetry (CV) and the graphite–polyurethane composite electrode (GPU). In CV studies, well-defined redox peaks characterize the oxidation process at the GPU electrode, which is indicative of electrocatalytic effects associated with active sites on the GPU electrode surface. A new analytical methodology was developed using the GPU electrode and square wave voltammetry (SWV) in BR buffer solution (0.1 mol L–1; pH 7.4). Analytical curves were constructed under optimized conditions (f=60s–1, Ea=50 mV, EI=2 mV) and detection and quantification limits of 6.4×10–8 mol L–1 (12.1 g L–1) and 5.2×10–6 mol L–1 (0.9 mg L–1), respectively, were achieved. The precision of the method was checked by performing ten successive measurements for a 9.9×10–6 mol L–1 dopamine solution. For intra-assay and inter-assay precisions, the relative standard deviations were 1.9 and 2.3%, respectively. In order to evaluate the developed methodology, the determination of dopamine was performed with good sensitivity and selectivity, without the interference of ascorbic acid in synthetic cerebrospinal fluid, which indicates that the new methodology enables reliable analysis of dopamine.  相似文献   

20.
The electrochemical behavior of the copper-tyrosine complex has been studied by linear-sweep adsorption voltammetry. In 0.02 mol/L Na2HPO4 buffer solution (pH=9.6), the complex can be adsorped on a hanging mercury drop electrode and reduced at a peak potential of about –0.42 V (vs. SCE). The secondary derivative peak height is linear proportional to the concentration of tyrosine in the range 1.0×10–7–5.0×10–5 mol/L. The detection limit is 5×10–8 mol/L.Project supported by the Provincial Science Foundation of Shandong Province  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号