首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
To assess temporal integration in normal hearing, cochlear impairment, and impairment simulated by masking, absolute thresholds for tones were measured as a function of duration. Durations ranged from 500 ms down to 15 ms at 0.25 kHz, 8 ms at 1 kHz, and 2 ms at 4 and 14 kHz. An adaptive 2I, 2AFC procedure with feedback was used. On each trial, two 500-ms observation intervals, marked by lights, were presented with an interstimulus interval of 250 ms. The monaural signal was presented in the temporal center of one observation interval. The results for five normal and six impaired listeners show: (1) normal listeners' thresholds decrease by about 8 to 10 dB per decade of duration, as expected; (2) listeners with cochlear impairments generally show less temporal integration than normal listeners; and (3) listeners with impairments simulated using masking noise generally show the same amount of temporal integration as normal listeners tested in the quiet. The difference between real and simulated impairments indicates that the reduced temporal integration observed in impaired listeners probably is not due to splatter of energy to frequency regions where thresholds are low, but reflects reduced temporal integration per se.  相似文献   

2.
Psychometric functions for level discrimination   总被引:1,自引:0,他引:1  
To determine the form of psychometric functions for 2I,2AFC level discrimination (commonly called intensity discrimination), ten increment levels were presented in random order within blocks of 100 trials. Stimuli were chosen to encompass a wide range of conditions and difference limens: eight 10-ms tones had frequencies of 0.25, 1, 8, or 14 kHz and levels of 30, 60, or 90 dB SPL; two 500-ms stimuli also were tested: a 1-kHz tone at 90 dB SPL and broadband noise at 63 dB SPL. For each condition, at least 20 blocks were presented in mixed order. Results for five normal listeners show that the sensitivity, d', is nearly proportional to delta L (= 20 log [(p + delta p)/p], where p is sound pressure) over the entire range of difference limens. When d' is plotted against Weber fractions for sound pressure, delta p/p, or intensity, delta I/I, exponents of the best-fitting power functions decrease with increasing difference limens and are less than unity for large difference limens. The approximately proportional relation between d' and delta L agrees with modern multichannel models of level discrimination and with psychometric functions derived for single auditory-nerve fibers. The results also support the notion that the difference limen, expressed as delta LDL and plotted on a logarithmic scale, is an appropriate representation of performance in level-discrimination experiments.  相似文献   

3.
To investigate how hearing loss of primarily cochlear origin affects the loudness of brief tones, loudness matches between 5- and 200-ms tones were obtained as a function of level for 15 listeners with cochlear impairments and for seven age-matched controls. Three frequencies, usually 0.5, 1, and 4 kHz, were tested in each listener using a two-interval, two--alternative forced--choice (2I, 2AFC) paradigm with a roving-level, up-down adaptive procedure. Results for the normal listeners generally were consistent with published data [e.g., Florentine et al., J. Acoust Soc. Am. 99, 1633-1644 (1996)]. The amount of temporal integration--defined as the level difference between equally loud short and long tones--varied nonmonotonically with level and was largest at moderate levels. No consistent effect of frequency was apparent. The impaired listeners varied widely, but most showed a clear effect of level on the amount of temporal integration. Overall, their results appear consistent with expectations based on knowledge of the general properties of their loudness-growth functions and the equal-loudness-ratio hypothesis, which states that the loudness ratio between equal-SPL long and brief tones is the same at all SPLs. The impaired listeners' amounts of temporal integration at high SPLs often were larger than normal, although it was reduced near threshold. When evaluated at equal SLs, the amount of temporal integration well above threshold usually was in the low end of the normal range. Two listeners with abrupt high-frequency hearing losses (slopes > 50 dB/octave) showed larger-than-normal maximal amounts of temporal integration (40 to 50 dB). This finding is consistent with the shallow loudness functions predicted by our excitation-pattern model for impaired listeners [Florentine et al., in Modeling Sensorineural Hearing Loss, edited by W. Jesteadt (Erlbaum, Mahwah, NJ, 1997), pp. 187-198]. Loudness functions derived from impaired listeners' temporal-integration functions indicate that restoration of loudness in listeners with cochlear hearing loss usually will require the same gain whether the sound is short or long.  相似文献   

4.
This study tests the hypothesis that temporal integration for detection of tone bursts with various durations can be explained by optimally combining multiple looks of brief signal segments whose contribution to detection increases over time. Detectability was measured for signals consisting of six consecutive 25-ms, 1-kHz tone pulses presented in a 50-Hz-wide masker or in maskers consisting of seven 50-Hz-wide noises, one critical band apart, with either coherent or incoherent envelopes. The level of each signal pulse varied randomly around masked threshold according to a Gaussian distribution. The slopes of conditional psychometric functions--plotted in terms of d'2 as a function of the squared signal-pulse intensity for pulses in a particular temporal position--yielded estimates of the contribution to detection provided by each pulse. Results for three normal listeners showed a small, but significant, effect of the temporal location of the pulse. Multiple-looks predictions of temporal-integration functions based on the measured weights and on measured psychometric functions were compared to measured temporal-integration functions. For the single-band and incoherent maskers, the predicted temporal-integration slopes were reasonably consistent with those measured, but for the coherent masker it was not. Whereas no current theory can explain the very steep temporal-integration functions obtained in the coherent masker, the present results are not inconsistent with the multiple-looks hypothesis as an explanation for the decrease in threshold with increasing duration of signals presented in random maskers.  相似文献   

5.
Lateralization and frequency selectivity in normal and impaired hearing   总被引:1,自引:0,他引:1  
The onset-time difference delta T required to lateralize a 30-ms bifrequency tone burst toward the leading ear was measured as a function of the frequency difference delta F between the tone in the left ear and the tone in the right ear. At center frequencies of 0.5 and 4 kHz, four normal listeners tested at 80 and 100 dB SPL had delta Ts that were relatively constant at subcritical delta Fs, but increased at delta Fs wider than a critical band. At 1 kHz, delta T increased with delta F even at subcritical delta Fs. Ten listeners with cochlear impairments were tested at 100 dB SPL. Seven had normal delta Ts at 4 kHz, despite hearing losses between 50 and 70 dB. At 0.5 and 1 kHz, mildly impaired listeners had nearly normal lateralization functions, whereas more severely imparied listeners had very large delta Ts and no frequency selectivity. These and other findings indicate that listeners even with moderate to severe hearing losses can lateralize normally on the basis of interaural differences in onset envelope, but not on the basis of temporal differences in the fine structure.  相似文献   

6.
Temporal masking curves were obtained from 12 normal-hearing and 16 hearing-impaired listeners using 200-ms, 1000-Hz pure-tone maskers and 20-ms, 1000-Hz fixed-level probe tones. For the delay times used here (greater than 40 ms), temporal masking curves obtained from both groups can be well described by an exponential function with a single level-independent time constant for each listener. Normal-hearing listeners demonstrated time constants that ranged between 37 and 67 ms, with a mean of 50 ms. Most hearing-impaired listeners, with significant hearing loss at the probe frequency, demonstrated longer time constants (range 58-114 ms) than those obtained from normal-hearing listeners. Time constants were found to grow exponentially with hearing loss according to the function tau = 52e0.011(HL), when the slope of the growth of masking is unity. The longest individual time constant was larger than normal by a factor of 2.3 for a hearing loss of 52 dB. The steep slopes of the growth of masking functions typically observed at long delay times in hearing-impaired listeners' data appear to be a direct result of longer time constants. When iterative fitting procedures included a slope parameter, the slopes of the growth of masking from normal-hearing listeners varied around unity, while those from hearing-impaired listeners tended to be less (flatter) than normal. Predictions from the results of these fixed-probe-level experiments are consistent with the results of previous fixed-masker-level experiments, and they indicate that deficiencies in the ability to detect sequential stimuli should be considerable in hearing-impaired listeners, partially because of extended time constants, but mostly because forward masking involves a recovery process that depends upon the sensory response evoked by the masking stimulus. Large sensitivity losses reduce the sensory response to high SPL maskers so that the recovery process is slower, much like the recovery process for low-level stimuli in normal-hearing listeners.  相似文献   

7.
A correlational analysis was used to assess the relative weight given to the levels of two monaurally presented tone pulses for interpulse intervals (IPIs) ranging from 2-256 ms. In three different experimental conditions, listeners were instructed to discriminate the level of the first pulse, the level of the second pulse, or the difference between the levels of the two pulses. The level of the target pulse was chosen randomly and independently from trial to trial from a Gaussian distribution. The level of the nontarget pulse was either fixed at 75 dB SPL or varied in the same manner as the level of the target. In the tasks in which one pulse was to be ignored, listeners gave increasing weight to the nontarget component as IPI decreased. Listeners weighted the level information in the pulses appropriately only when the IPI approached 256 ms. When the listeners were instructed to compare the pulse levels to one another, two of three listeners weighted the levels optimally at all IPIs, while the third listener did so only at the longest IPI. For the two listeners who weighted the pulses optimally, a minimum in performance was achieved at IPIs around 16-32 ms. Intensity discrimination thresholds were also measured for one pulse in the presence of a second fixed pulse for IPIs of 2-256 ms. Thresholds were higher in all the two-pulse conditions relative to a one-pulse condition, and were dependent on the level of the nontarget pulse but not on IPI. The results indicate that level information is integrated to some extent over fairly long durations, but not in a manner that is consistent with simple temporal integration.  相似文献   

8.
This study presents a psychoacoustic analysis of the integration of spectral and temporal cues in the discrimination of simple nonspeech sounds. The experimental task was a same-different discrimination between a standard and a comparison pair of tones. Each pair consists of two 80-ms, 1500-Hz tone bursts separated by a 60-ms interval. The just-discriminable (d' = 2.0) increment in duration delta t, of one of the bursts was measured as a function of increments in the frequency delta f, of the other burst. A trade off between the values of delta t and delta f required to perform at d' = 2.0 was observed, which suggests that listeners integrate the evidence from the two dimensions. Integration occurred with both sub- and supra-threshold values of delta t or delta f, regardless of the order in which the cues were presented. The performance associated to the integration of cues was found to be determined by the discriminability of delta t plus that of delta f, and thus, it is within the psychophysical limits of auditory processing. To a first approximation the results agreed with the prediction of orthogonal vector summation of evidence stemming from signal detection theory. It is proposed that the ability to integrate spectral and temporal cues is in the repertoire of auditory processing capabilities. This integration does not appear to depend on perceiving sounds as members of phonetic classes.  相似文献   

9.
The decrease in absolute threshold with increasing stimulus duration (often referred to as "temporal integration") is greater for listeners with normal hearing than for listeners with sensorineural hearing loss. It has been suggested that the difference is related to reduced basilar-membrane (BM) compression in the impaired group. The present experiment tested this hypothesis by comparing temporal integration and BM compression in normal and impaired ears at low levels. Absolute thresholds were measured for 4, 24, and 44 ms pure-tone signals, with frequencies (f(s)) of 2 and 4 kHz. The difference between the absolute thresholds for the 4 and 24 ms signals was used as a measure of temporal integration. Compression near threshold was estimated by measuring the level of a 100 ms off-frequency (0.45f(s)) pure-tone forward masker required to mask a 44 ms pure-tone signal presented at sensation levels of 5 and 10 dB. There was a significant negative correlation between amount of temporal integration and absolute threshold. However, there was no correlation between absolute threshold and compression at low levels; both normal and impaired ears showed a nearly linear response. The results suggest that the differences in integration between normal and impaired ears cannot be explained by differences in BM compression.  相似文献   

10.
This paper extends previous research on listeners' abilities to discriminate the details of brief tonal components occurring within sequential auditory patterns (Watson et al., 1975, 1976). Specifically, the ability to discriminate increments in the duration delta t of tonal components was examined. Stimuli consisted of sequences of ten sinusoidal tones: a 40-ms test tone to which delta t was added, plus nine context tones with individual durations fixed at 40 ms or varying between 20 and 140 ms. The level of stimulus uncertainty was varied from high (any of 20 test tones occurring in any of nine factorial contexts), through medium (any of 20 test tones occurring in ten contexts), to minimal levels (one test tone occurring in a single context). The ability to discriminate delta t depended strongly on the level of stimulus uncertainty, and on the listener's experience with the tonal context. Asymptotic thresholds under minimal uncertainty approached 4-6 ms, or 15% of the duration of the test tones; under high uncertainty, they approached 40 ms, or 10% of the total duration of the tonal sequence. Initial thresholds exhibited by inexperienced listeners are two-to-four times greater than the asymptotic thresholds achieved after considerable training (20,000-30,000 trials). Isochronous sequences, with context tones of uniform, 40-ms duration, yield lower thresholds than those with components of varying duration. The frequency and temporal position of the test tones had only minor effects on temporal discrimination. It is proposed that a major determinant of the ability to discriminate the duration of components of sequential patterns is the listener's knowledge about "what to listen for and where." Reduced stimulus uncertainty and extensive practice increase the precision of this knowledge, and result in high-resolution discrimination performance. Increased uncertainty, limited practice, or both, would allow only discrimination of gross changes in the temporal or spectral structure of the sequential patterns.  相似文献   

11.
Psychophysical pulse-train forward-masking (PTFM) recovery functions were measured in fifteen subjects with the Nucleus mini-22 cochlear implant and six subjects with the Clarion cochlear implant. Masker and probe stimuli were 500-Hz trains of 200- or 77-micros/phase biphasic current pulses. Electrode configurations were bipolar for Nucleus subjects and monopolar for Clarion subjects. Masker duration was 320 ms. Probe duration was either 10 ms or 30 ms. Recovery functions were measured for a high-level masker on a middle electrode in all 21 subjects, on apical and basal electrodes in 7 of the Nucleus and 3 of the Clarion subjects, and for multiple masker levels on the middle electrode in 8 Nucleus subjects and 6 Clarion subjects. Recovery functions were described by an exponential process in which threshold shift (in microA) decreased exponentially with increasing time delay between the offset of the masker pulse train and the offset of the probe pulse train. All but 3 of the 21 subjects demonstrated recovery time constants on a middle electrode that were less than 95 ms. The mean time constant for these 18 subjects was 54 ms (s.d. 17 ms). Three other subjects tested on three electrodes exhibited time constants larger than 95 ms from an apical electrode only. Growth-of-masking slopes depended upon time delay, as expected from an exponential recovery process, i.e., progressively shallower slopes were observed at time delays of 10 ms and 50 ms. Recovery of threshold shift (in microA) for PTFM in electrical hearing behaves inthe same way as recovery of threshold shift (in dB) for pure-tone forward masking in acoustic hearing. This supports the concept that linear microamps are the electrical equivalent of acoustic decibels. Recovery from PTFM was not related to speech recognition in a simple manner. Three subjects with prolonged PTFM recovery demonstrated poor speech scores. The remaining subjects with apparently normal PTFM recovery demonstrated speech scores ranging from poor to excellent. Findings suggest that normal PTFM recovery is only one of several factors associated with good speech recognition in cochlear-implant listeners. Comparisons of recovery curves for 10- and 30-ms probe durations in two subjects showed little or no temporal integration at time delays less than 95 ms where recovery functions have steep slopes. The same subjects exhibited large amounts of temporal integration at longer time delays where recovery slopes are more gradual. This suggests that probe detection depends primarily on detection of the final pulses in the probe stimulus and supports the use of offset-to-offset time delays for characterizing PTFM recovery in electric hearing.  相似文献   

12.
This study compared the ability of 5 listeners with normal hearing and 12 listeners with moderate to moderately severe sensorineural hearing loss to discriminate complementary two-component complex tones (TCCTs). The TCCTs consist of two pure tone components (f1 and f2) which differ in frequency by delta f (Hz) and in level by delta L (dB). In one of the complementary tones, the level of the component f1 is greater than the level of component f2 by the increment delta L; in the other tone, the level of component f2 exceeds that of component f1 by delta L. Five stimulus conditions were included in this study: fc = 1000 Hz, delta L = 3 dB; fc = 1000 Hz, delta L = 1 dB; fc = 2000 Hz, delta L = 3 dB; fc = 2000 Hz, delta L = 1 dB; and fc = 4000 Hz, delta L = 3 dB. In listeners with normal hearing, discrimination of complementary TCCTs (with a fixed delta L and a variable delta f) is described by an inverted U-shaped psychometric function in which discrimination improves as delta f increases, is (nearly) perfect for a range of delta f's, and then decreases again as delta f increases. In contrast, group psychometric functions for listeners with hearing loss are shifted to the right such that above chance performance occurs at larger values of delta f than in listeners with normal hearing. Group psychometric functions for listeners with hearing loss do not show a decrease in performance at the largest values of delta f included in this study. Decreased TCCT discrimination is evident when listeners with hearing loss are compared to listeners with normal hearing at both equal SPLs and at equal sensation levels. In both groups of listeners, TCCT discrimination is significantly worse at high center frequencies. Results from normal-hearing listeners are generally consistent with a temporal model of TCCT discrimination. Listeners with hearing loss may have deficits in using phase locking in the TCCT discrimination task and so may rely more on place cues in TCCT discrimination.  相似文献   

13.
Across-frequency integration of complex signals was investigated by measuring psychometric functions [log (d') versus signal level in dB SPL] for detection of brief and long signals presented in broadband noise. The signals were tones at 630, 1600, and 4000 Hz, and a nine-tone complex with components spaced at one-third-octave frequencies between 630 and 4000 Hz. The phase relationship of the components in the complex was varied such that adjacent components were in phase (at 0 degrees), 90, or 180 degrees out of phase. Signal durations (defined in terms of the number of cycles between the half-amplitude points of the Gaussian envelopes) of 4.7 and 150 cycles were tested. Results for six normal-hearing listeners showed that the slopes of the psychometric functions were steeper for the brief than for the long signals, and steeper for the tone complexes than for the tones, particularly for the brief signals. This suggests that the transformation from signal intensity to decision variable may be different for brief complex signals than for tonal signals and long complex signals. Thresholds obtained from the psychometric functions were in excellent agreement with those obtained with an adaptive procedure that employed three interleaved tracks. For the long signals, the threshold improvement for the tone complexes relative to a single tone was well described by a 5* log (n) integration rule. However, the threshold improvement for brief signals obeyed a more efficient integration rule of 7 to 8* log (n). A portion of this effect could be accounted for by the phase relationship of the tone complexes; thresholds for brief signals were lowest when the components were in phase at the envelope peak of the signal. This finding indicates that temporal synchrony across auditory channels may enhance detection of brief multi-tone complexes.  相似文献   

14.
Extracellular recordings from the cervical connectives in both long- and short-winged E. carolinus reveal auditory units that are sensitive to frequencies > 15 kHz with best sensitivity at 35 kHz (79 dB SPL threshold). Stimuli in this frequency range also elicit a startle response in long-winged individuals flying on a tether. For single-pulse stimuli, startle and neck connective thresholds decrease with increasing ultrasound duration, consistent with the operation of an exponential integrator with a approximately 32.5-ms time constant. There is evidence for adaptation to long duration pulses (> 20 ms) in the neck connectives, however, as it is more difficult to elicit responses to the later stimuli of a series. For paired-pulse stimuli consisting of 1-ms pulses of 40 kHz, temporal integration was demonstrated for pulse separations < 5 ms. For longer pulse separations, startle thresholds were elevated by 3 dB and appear to be optimally combined. Startle thresholds to 5 ms frequency modulated (FM) sweeps (60-30 kHz) and pure tone pulses (40 kHz) did not differ. The characteristics and sensitivity of this ultrasound-induced startle response did not differ between males and females. As in some other tympanate insects, ultrasound sensitivity in E. carolinus presumably functions in the context of predation from echolocating bats.  相似文献   

15.
Subjects discriminated a "standard" pair of tone bursts (T1, T2) from a "comparison" pair (T1 + delta t, T2 + delta f), containing increments in the duration delta t of the first burst and/or the frequency delta f of the second burst. The threshold (d' = 2.0) for delta t was measured as a function of delta f, and the threshold for delta f as a function of delta t. The integration of increments in duration and frequency was studied as a function of the spectral and temporal separation between T1 and T2. A trade-off between the values of delta t and delta f required for d' = 2.0 performance was observed. This integration takes place when delta t, delta f occur simultaneously in the same spectral region, and when they occur separated by up to 120 ms, or by up to a full octave. The efficiency of integration was similar for all conditions of temporal and spectral separation studied, because the discriminability of delta t and of delta f is also nearly uniform across experimental conditions. The results from all experimental conditions are adequately described by a vector summation model derived from TSD. In a subsidiary experiment, subjects categorized pure tones varying in duration and frequency as "high" or "low" in pitch and "long" or "short" in duration. It was found that combined variations in duration and frequency result in essentially independent perceptual processes, although pitch has a small effect upon the perceived duration. It is concluded that spectral-temporal integration is a general ability operating in a variety of stimulus conditions.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

16.
Psychometric functions for detecting increments or decrements in level of sinusoidal pedestals were measured for increment and decrement durations of 5, 10, 20, 50, 100, and 200 ms and for frequencies of 250, 1000, and 4000 Hz. The sinusoids were presented in background noise intended to mask spectral splatter. A three-interval, three-alternative procedure was used. The results indicated that, for increments, the detectability index d' was approximately proportional to delta I/I. For decrements, d' was approximately proportional to delta L. The slopes of the psychometric functions increased (indicating better performance) with increasing frequency for both increments and decrements. For increments, the slopes increased with increasing increment duration up to 200 ms at 250 and 1000 Hz, but at 4000 Hz they increased only up to 50 ms. For decrements, the slopes increased for durations up to 50 ms, and then remained roughly constant, for all frequencies. For a center frequency of 250 Hz, the slopes of the psychometric functions for increment detection increased with duration more rapidly than predicted by a "multiple-looks" hypothesis, i.e., more rapidly than the square root of duration, for durations up to 50 ms. For center frequencies of 1000 and 4000 Hz, the slopes increased less rapidly than predicted by a multiple-looks hypothesis, for durations greater than about 20 ms. The slopes of the psychometric functions for decrement detection increased with decrement duration at a rate slightly greater than the square root of duration, for durations up to 50 ms, at all three frequencies. For greater durations, the increase in slope was less than proportional to the square root of duration. The results were analyzed using a model incorporating a simulated auditory filter, a compressive nonlinearity, a sliding temporal integrator, and a decision device based on a template mechanism. The model took into account the effects of both the external noise and an assumed internal noise. The model was able to account for the major features of the data for both increment and decrement detection.  相似文献   

17.
Psychophysical forward-masked thresholds were estimated for 3- and 6-month-old infants and for adults. Listeners detected a repeated 1000-Hz probe, with 16-ms rise time, no steady-state duration, and 16-ms fall time. Unmasked thresholds were determined for one group of listeners who were trained to respond when they heard the probe but not at other times. In the masking conditions, each tone burst was preceded by a 100-ms broadband noise masker at 65 dB SPL. Listeners were trained to respond when they heard the probe and masker, but not when they heard the masker alone. The masker-probe interval, delta t, was either 5, 10, 25, or 200 ms. Four groups of subjects listened in the masked conditions, each at one value of delta t. Each listener attempted to complete a block of 32 trials including four probe levels chosen to span the range of expected thresholds. "Group" thresholds, based on average psychometric functions, as well as thresholds for individual listeners, were estimated. Both group and individual thresholds declined with delta t, as expected, for both infants and adults. Infants' masked thresholds were higher than those of adults, and comparison of masked to unmasked thresholds suggested that infants demonstrate more forward masking than adults, particularly at short delta t. Forward masking appeared to have greater effects on 3-month-olds' detection than on either 6-month-olds' or adults'. Compared to adults, 6-month-olds demonstrated more forward masking only for delta t of 5 ms. Thus, susceptibility to forward masking may be nearly mature by 6 months of age.  相似文献   

18.
The study measured listener sensitivity to increments in the inter-onset interval (IOI) separating pairs of successive 20-ms 4000-Hz tone pulses. A silent interval between the tone pulses was adjusted across conditions to create reference tonal IOI values of 25-600 ms. For each condition, a duration DL for increments of the tonal IOI was measured in listeners comprised of young normal-hearing adults and two groups of older adults with and without high-frequency hearing loss. Discrimination performance of all listeners was poorest for the shorter reference IOIs, and improved to stable levels for longer reference intervals exceeding about 200 ms. Temporal sensitivity of the young listeners was significantly better than that of the elderly listeners in each condition, with the largest age-related differences observed for the shortest reference interval. Age-related differences were also observed for duration DLs measured using single 4000-Hz tone bursts set to three reference durations in the range 50-200 ms. The tone DLs of all listeners were smaller than the corresponding tone-pair IOI DLs, particularly for the shorter reference stimulus durations. There were no significant performance differences observed between the older listeners with and without hearing loss for either discrimination task.  相似文献   

19.
Performance-intensity functions were defined for ten synthetic vowels whose durations (50 ms) were shorter than the time necessary for the acoustic reflex to alter the transmission characteristics of the middle ear. Recognition accuracy for ten listeners with normal auditory function was asymptotic from 72 to 90 dB and then fell linearly to 108 dB. Thus, at SPLs greater than approximately 90 dB, the auditory encoding of vowels is altered by the absence of the acoustic reflex.  相似文献   

20.
The induced reduction in the loudness (ILR) of a weaker tone caused by a preceding stronger tone was measured with both tones in the same ear (ipsilateral ILR) and also in opposite ears (contralateral ILR). The two tones were always equal in duration and were presented repeatedly over several minutes. When the tone duration was 200 ms, for 24 listeners the loudness reduction averaged 11 dB under ipsilateral ILR and 6 dB under contralateral ILR. When the duration was 5 ms, ILR was 8 dB whether ipsilateral or contralateral. For each duration, ipsilateral and contralateral ILR were strongly correlated (r around 0.80).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号