1.
Investigation of isoelectric focusing (IEF) kinetics has been performed to provide the theoretical basis for miniaturization of classical IEF in immobilized pH-gradients. Standard IEF demands colinearity of the electric field and pH-gradient directions (serial devices). It is shown that the IEF separation process based on a continuous, serial pH gradient is incompatible with miniaturization of separation devices. The new realization of the IEF device by a parallel IEF chip is suggested and analyzed. The main separation tool of the device is a dielectric membrane (chip) with conducting channels that are filled by Immobiline gels of varying pH. The membrane is held perpendicular to the applied electric field and proteins are collected (trapped) in the channels whose pH are equal to the pI of the proteins. The pH value of the surrounded aqueous solution is not equal to any channel's pH. The fast particle transport between different channels takes place due to convection in the aqueous solution. The new device geometry introduces two new spatial scales to be considered: the scale of transition region from a solution to the gel in a channel and a typical channel size. The corresponding time scales defining the IEF process kinetics are analyzed and scaling laws are obtained. It is shown both theoretically and experimentally that parallel IEF accelerates the fractionation of proteins by their pI down to several minutes and enables possible efficient sample collection and purification.  相似文献   

2.
Isoelectric focusing (IEF), traditionally accomplished in slab or tube gels, has also been performed extensively in capillary and, more recently, in microchip formats. IEF separations performed in microchips typically use electroosmotic flow (EOF) or chemical treatment to mobilize the focused zones past the detection point. This report describes the development and optimization of a microchip IEF method in a hybrid PDMS-glass device capable of controlling the mobilization of the focused zones past the detector using on-chip diaphragm pumping. The microchip design consisted of a glass fluid layer (separation channels), a PDMS layer and a glass valve layer (pressure connections and valve seats). Pressure mobilization was achieved on-chip using a diaphragm pump consisting of a series of reversible elastomeric valves, where a central diaphragm valve determined the volume of solution displaced while the gate valves on either side imparted directionality. The pumping rate could be adjusted to control the mobilization flow rate by varying the actuation times and pressure applied to the PDMS to actuate the valves. In order to compare the separation obtained using the chip with that obtained in a capillary, a serpentine channel design was used to match the separation length of the capillary, thereby evaluating the effect of diaphragm pumping itself on the overall separation quality. The optimized mIEF method was applied to the separation of labeled amino acids.  相似文献   

3.
This review focuses on capillary electrophoretic separations performed on capillary electrophoresis chips (CE chips) with hydrodynamically closed separation systems in a context with transport processes (electroosmotic flow (EOF)) and hydrodynamic flow (HDF)) that may accompany the separations in these devices. It also reflects some relevant works dealing with conventional CE operating under such hydrodynamic conditions. The use of zone electrophoresis (ZE), isotachophoresis (ITP) and their on-line combination (ITP-ZE) on the single-column and column-coupling CE chips with the closed separation systems and related problems are key topics of the review. Some attention is paid to sample pretreatment in the separations performed on the CE chips. Here, mainly potentialities of the ITP-ZE combination in trace analysis applications of the miniaturized systems are discussed in a broader extent. Links between the ZE separation and detection provide a frame for the discussion of current status of the detection on the CE chips. Analytical applications illustrate potentialities of the CE chips operating with the closed separation systems (suppressed HDF and EOF) to the determination of small ions present in various matrices by ZE, ITP and ITP-ZE.  相似文献   

4.
Electrophoretic separations at typical experimental electric field strengths have been simulated by applying the flux-corrected transport (FCT) finite difference method to the transient, one-dimensional electrophoresis model. The performance of FCT on simulations of zone electrophoresis (ZE), isotachophoresis (ITP), and isoelectric focusing (IEF) has been evaluated. An FCT algorithm, with a three-point, central spatial discretization, yields numerical solutions without numerical oscillations or spurious peaks, which have plagued previously-published second-order solutions to benchmark ZE and ITP problems. Moreover, the FCT technique captures sharp zone boundaries and IEF peaks more accurately than previously-published, first-order upwind schemes.  相似文献   

5.
This feasibility study deals with column switching in zone electrophoresis (ZE) separations on a column coupling (CC) chip. The column switching implemented into the ZE separations an on-chip sample clean up applicable for both the multicomponent and high salinity samples. In addition, complemented by different separation mechanisms in the coupled columns (channels), it provided benefits of two-dimensional separations. Properly timed column switching gave column-to-column transfers of the analytes, characterized by 99-102% recoveries, delivered to the second separation stage on the chip the analyte containing fractions contaminated only with minimum amounts of the matrix constituents. A diffusion driven transport of the matrix constituents to the second channel of the chip (due to direct contacts of the electrolyte solutions in the bifurcation region), representing 0.1-0.2% of the loaded sample constituents, was found to accompany the sample clean up performed on the CC chip. This source of potential disturbances to the separation in the second channel, however, is not detectable in a majority of practical situations. With respect to a 900 nl volume of the sample channel on the CC chip, the electric field and isotachophoresis (ITP) stackings were employed to minimize the injection dispersion in the separations and concentrate the analytes. Here, the column switching, removing a major part of the stacker from the separation system, provided a tool effective in a control of the destacking of analytes. Highly reproducible ZE separations as attained in this work also for the chip-to-chip and equipment-to-equipment frames can be ascribed, at least in part, to suppressions of electroosmotic and hydrodynamic flows of the solutions in which the separations were performed.  相似文献   

6.
Two-dimensional gel electrophoresis practitioners have long waited for a fully automated system. This article presents an integrated platform that is capable of complete automation from sample introduction to spots detection. The strip gel for the first dimensional separation is fixed on the edge of a discrete planar stage before separation. A pair of platinum pin electrodes for isoelectric focusing (IEF) makes contact from underneath the stage. IEF is performed directly after rehydration and protein loading. After the first dimensional separation, sodium dodecyl sulfate (SDS) equilibration is done on the same stage without moving the gel. The IEF stage is then moved horizontally to couple with a precast second dimensional gel. The <0.5 mm gap between the two gels is filled with poly (ethylene oxide) solution. After SDS-polyacrylamide gel electrohporesis separation, a charge-coupled device camera is used to detect spots via protein native fluorescence excited by a Hg (Xe) lamp with the gel inside the running cell. Potential for full automation is demonstrated with 0.5 microg of Escherichia coli proteins on this miniaturized platform. More than 240 spots are detected in a total experiment time of <2.5 h.  相似文献   

7.
We have evaluated double-stranded DNA separations in microfluidic devices which were designed to couple a sample preconcentration step based on isotachophoresis (ITP) with a zone electrophoretic (ZE) separation step as a method to increase the concentration limit of detection in microfluidic devices. Developed at ACLARA BioSciences, these LabCard trade mark devices are plastic 32 channel chips, designed with a long sample injection channel segment to increase the sample loading. These chips were designed to allow stacking of the sample into a narrow band using discontinuous ITP buffers, and subsequent separation in the ZE mode in sieving polymer solutions. Compared to chip ZE, the sensitivity was increased by 40-fold and we showed baseline resolution of all fragments in the PhiX174/HaeIII DNA digest. The total analysis time was 3 min/sample, or less than 100 min per LabCard device. The resolution for multiplexed PCR samples was the same as obtained in chip ZE. The limit of detection was 9 fg/microL of DNA in 0.1xpolymerase chain reaction (PCR) buffers using confocal fluorescence detection following 488 nm laser excitation with thiazole orange as the fluorescent intercalating dye.  相似文献   

8.
This work deals with the determination of free sulfite in wine by zone electrophoresis (ZE) with on-line isotachophoresis (ITP) sample pretreatment on a column-coupling (CC) chip with conductivity detection. A rapid pre-column conversion of sulfite to hydroxymethanesulfonate (HMS), to minimize oxidation losses of the analyte, was included into the developed analytical procedure, while ITP and ZE were responsible for specific analytical tasks in the separations performed on the CC chip. ITP, for example, eliminated the sample matrix from the separation compartment and, at the same time, provided a selective concentration of HMS before its transfer to the ZE stage of the separation. On the other hand, ZE served as a final separation (destacking) method and it was used under the separating conditions favoring a sensitive conductivity detection of HMS. In this way, ITP and ZE cooperatively contributed to a 900 microg/l concentration detectability for sulfite as attained for a 60 nl load of wine (a 15-fold wine dilution and the use of a 0.9 microl sample injection channel of the chip) and, consequently, to the determination of free sulfite when this was present in wine at the concentrations as low as 3 mg/l. The separations were carried out in a closed separation compartment of the chip with suppressed hydrodynamic and electroosmotic flows. Such transport conditions, minimizing fluctuations of the migration velocities of the separated constituents, made a frame for precise migration and quantitation data as achieved for HMS in both the model and wine samples. Ninety percent recoveries, as typically obtained for free sulfite in wine samples, indicate promising potentialities of the present method as far as the accuracies of the provided analytical results are concerned.  相似文献   

9.
《Electrophoresis》2018,39(8):1040-1047
Isoelectric focusing (IEF) is a powerful separation method, useful for resolving subtle changes in the isoelectric point of unlabeled proteins. While microfluidic IEF has reduced the separation times from hours in traditional benchtop IEF to minutes, the enclosed devices hinder post‐separation access to the sample for downstream analysis. The two‐layer open IEF device presented here comprises a photopatterned hydrogel lid layer containing the chemistries required for IEF and a thin polyacrylamide bottom layer in which the analytes are separated. The open IEF device produces comparable minimum resolvable difference in isoelectric point and gradient stability to enclosed microfluidic devices while providing post‐separation sample access by simple removal of the lid layer. Further, using simulations, we determine that the material properties and the length of the separation lanes are the primary factors that affect the electric field magnitude in the separation region. Finally, we demonstrate self‐indexed photomasks for alignment‐free fabrication of multi‐domain hydrogels. We leverage this approach to generate arrayed pH gradients with a total of 80 concurrent separation lanes, which to our knowledge is the first demonstration of multiple IEF separations in series addressed by a single pair of electrodes.  相似文献   

10.
This feasibility study deals with the separations of proteins by an on-line combination of zone electrophoresis (ZE) with isotachophoresis (ITP) on a poly(methylmethacrylate) column-coupling (CC) chip with integrated conductivity detection. ITP and ZE provided specific analytical functions while performing the cationic mode of the separation. ITP served, mainly, for concentrations of proteins and its concentrating power was beneficial in reaching a low dispersion transfer (injection) of the proteinous constituents, loaded on the CC chip in a 960 nL volume, into the ZE separation stage. This was complemented by an electrophoretically driven removal of the sample constituents migrating in front of the focused proteins from the separation system before the ZE separation. On the other hand, ZE served as a final separation (destacking) method and it was used under the separating conditions providing the resolutions and sensitive conductivity detections of the test proteins. In this way, ITP and ZE cooperatively contributed to low- or sub-microg/mL concentration detectabilities of proteins and their quantitations at 1-5 microg/mL concentrations. However, a full benefit in concentration detectabilities of proteins, expected from the use of the ITP-ZE combination, was not reached in this work. Small adsorption losses of proteins and detection disturbances in the ZE stage of separation, very likely due to trace constituents concentrated by ITP, appear to set limits in the detection of proteins in our experiments. The ITP-ZE separations were carried out in a hydrodynamically closed separation compartment of the chip with suppressed hydrodynamic and electroosmotic flows of the electrolyte solutions. Such transport conditions, minimizing fluctuations of the migration velocities of the separated constituents, undoubtedly contributed to highly reproducible migrations of the separated proteins (fluctuations of the migration time of a particular protein were typically 0.5% RSD in repeated ITP-ZE runs).  相似文献   

11.
Clay liners are charged membranes and show semipermeable behavior regarding the flow of fluids, electrical charge, chemicals and heat. At zero gradients of temperature and hydrostatic pressure, a salt concentration gradient across a compacted clay sample induces not only an osmotic flux of water and diffusion of salt across the membrane but also an electrical potential gradient, defined as membrane potential. Laboratory experiments were performed on commercially available bentonite samples in a rigid-wall permeameter connected to two electrically insulated fluid reservoirs filled with NaCl solutions of different concentrations and equipped with Ag/AgCl electrodes to measure the electrical potential gradient. The effect of membrane potential could be cancelled out by short-circuiting the clay with the so-called virtual shortcut. The potential gradient across the sample is brought to zero with a negative feedback circuit. It was observed that the water flux and the diffusion of Cl- were hindered by the occurrence of a membrane potential, indicating that an electroosmotic counterflow is induced. Flow parameters were calculated with modified coupled flow equations of irreversible thermodynamics. They were in excellent agreement with values reported in the literature. Comparing the method of short-circuiting with a study elsewhere, where the electrodes were physically short-circuited, it was shown that the virtual shortcut is more appropriate because physically short-circuiting induces additional effects that are attributed to the fluxes.  相似文献   

12.
The use of a poly(methylmethacrylate) capillary electrophoresis chip, provided with a high sample load capacity separation system (a 8500 nL separation channel coupled to a 500 nL sample injection channel) and a pair of on-chip conductivity detectors, for zone electrophoresis (ZE) determination of oxalate in urine was studied. Hydrodynamic and electroosmotic flows of the solution in the separation compartment of the chip were suppressed and electrophoresis was a dominant transport process in the separations performed on the chip. A low pH of the carrier electrolyte (4.0) provided an adequate selectivity in the separation of oxalate from anionic urine constituents and, at the same time, also a sufficient sensitivity in its conductivity detection. Under our working conditions, this anion could be detected at a 8 x 10(-8) mol/L concentration also in samples containing chloride (a major anionic constituent of urine) at 3.5 x 10(-3) mol/L concentrations. Such a favorable analyte/matrix concentration ratio (in part, attributable to a transient isotachophoresis stacking in the initial phase of the separation) made possible accurate and reproducible (typically, 2-5% relative standard deviation (RSD) values of the peak areas of the analyte in dependence on its concentration in the sample) determination of oxalate in 500 nL volumes of 20-100-fold diluted urine samples. Short analysis times (about 280 s), no sample pretreatment (not considering urine dilution) and reproducible migration times of this analyte (0.5-1.0% RSD values) were characteristic for ZE on the chip. This work indicates general potentialities of the present chip design in rapid ZE analysis of samples containing the analyte(s) at high ionic matrix/analyte concentration ratios.  相似文献   

13.
The use of a poly(methylmethacrylate) capillary electrophoresis chip, provided with a high sample load capacity separation system (a 8500 nL separation channel combined with a 500 nL sample injection channel) and a pair of on‐chip conductivity detectors, for zone electrophoresis (ZE) determination of oxalate in beer was studied. Hydrodynamic and electroosmotic flows of the solution in the separation compartment of the chip were suppressed and electrophoresis was a dominant transport process in the separations performed on the chip. A low pH of the carrier electrolyte (3.8), implemented by aspartic acid and bis‐tris propane, provided an adequate selectivity in the separation of oxalate from anionic beer constituents and, at the same time, also a sufficient sensitivity in its conductivity detection. Under our working conditions, this anion could be detected at a 0.5 μmol/L concentration also in samples containing chloride (a major anionic constituent of beer) at a 1800 higher concentration. Such a favorable analyte/matrix concentration ratio made possible accurate and reproducible [typically, 2–5% relative standard deviation (RSD) values of the peak areas of the analyte in dependence on its concentration in the sample] determination of oxalate in 500 nL volumes of 20–50‐fold diluted beer samples. Short analysis times (about 200 s), minimum sample preparation, and reproducible migration times of this analyte (0.5–1.0% RSD values) were characteristic for ZE on the chip.  相似文献   

14.
Slais K 《Electrophoresis》2008,29(12):2451-2457
Continuous-flow isoelectric focusing (IEF) has the potential to be an important method in proteome analysis. The current devices do not fully use the advantages of IEF, because they do not utilize all its important features including changes in background conductivity during the focusing. A novel continuous-flow IEF method has been developed based on planar divergent flow and control of local electric field by conductivity of electrode electrolytes. A hydrophilized polypropylene nonwoven fabric was used for creation of flow and electric manifold, making the assembled device cheap, flexible and easy to set up and operate. By using the colored low-molecular-weight pI markers we demonstrated much higher speed of focusing in the new designed channel in comparison with a channel based on currently used rectangular geometry. The developed divergent-flow IEF combines the speed of micro flow channels with the separation efficiency and sample load capacity of preparative devices.  相似文献   

15.
This work deals with zone electrophoresis (ZE) separations of proteins on a poly(methyl methacrylate) chip with integrated conductivity detection. Experiments were performed in the cationic mode of the separation (pH 2.9) with a hydrodynamically closed separation compartment and suppressed electroosmotic flow. The test proteins reached the detector in less than 10 min under these working conditions and their migration times characterized excellent repeatabilities (0.1–0.6% RSD values). The chip-to-chip agreements of the migration times, evaluated from the ZE runs performed on three chips, were within 1.5%. The conductivity detection provided for protein, loaded on the chip at 10–1000 μg/ml concentrations, detection responses were characterized by 1–5% RSD values of their peak areas. Such migration and detection performances made a frame for reproducible baseline separations of a five-constituent mixture (cytochrome c, avidin, conalbumin, human hemoglobin and trypsin inhibitor). On the other hand, a high sample injection channel/separation compartment volume ratio of the chip (500 nl/8500 nl) restricted the resolution of proteins of very close effective mobilities in spite of the fact that in the initial phase of the separation an electric field stacking was applied. A maximum macroconstituent/trace constituent ratio attainable for proteins on the chip was assessed for cytochrome c (quantifiable when its concentration in the loaded sample was 10 μg/ml) and apo-transferrin (containing a trace constituent migrating in the position of cytochrome c detectable when the load of apo-transferrin was 2000 μg/ml). This assessment indicated that a ratio of 1000:1 is attainable with the aid of conductivity detection on the present chip.  相似文献   

16.
A four-electrode impedance-based microfluidic device has been designed with tunable sensitivity for future applications to the detection of pathogens and functionalized microparticles specifically bound to molecular recognition molecules on the surface of a microfluidic channel. In order to achieve tunable sensitivity, hydrodynamic focusing was employed to confine the electric current by simultaneous introduction of two fluids (high- and low-conductivity solutions) into a microchannel at variable flow-rate ratios. By increasing the volumetric flow rate of the low-conductivity solution (sheath fluid) relative to the high-conductivity solution (sample fluid), increased focusing of the high-conductivity solution over four coplanar electrodes was achieved, thereby confining the current during impedance interrogation. The hydrodynamic and electrical properties of the device were analyzed for optimization and to resolve issues that would impact sensitivity and reproducibility in subsequent biosensor applications. These include variability in the relative flow rates of the sheath and sample fluids, changes in microchannel dimensions, and ionic concentration of the sample fluid. A comparative analysis of impedance measurements using four-electrode versus two-electrode configurations for impedance measurements also highlighted the advantages of using four electrodes for portable sensor applications.
A four-electrode sensor with hydrodynamic focusing to confine that the current was characterized for tunable sensitivity  相似文献   

17.
Albrecht JW  Jensen KF 《Electrophoresis》2006,27(24):4960-4969
Rapid free-flow IEF is achieved in a microfluidic device by separating the electrodes from the focusing region with porous buffer regions. Moving the electrodes outside enables the use of large electric fields without the detrimental effects of bubble formation in the active region. The anode and cathode porous buffer regions, which are formed by acrylamide functionalized with immobilized pH groups, allow ion transport while providing buffering capacity. Thermoelectric cooling mitigates the effects of Joule heating on sample focusing at high field strengths (approximately 500 V/cm). This localized cooling was observed to increase device performance. Rapid focusing of low-molecular-weight p/ markers and Protein G-mouse IgG complexes demonstrate the versatility of the technique. Simulations provide insight into and predict device performance based on a well-defined sample composition.  相似文献   

18.
As microfluidic technologies mature, increasingly complex solutions are employed, and accurate methods for the measurement of electroosmotic flow rates are becoming increasingly important. The methodologies of both a direct method and an indirect method of flow rate measurement are presented here. The direct method involves flow visualization using trace amounts of a caged fluorescent dye. The indirect method is based on the change in current that occurs when one solution in the microchannel is replaced by another. The results of concurrent and independent measurements of electroosmotic velocities of Tris-acetate with EDTA (TAE) and Tris-borate with EDTA (TBE) at 1x concentration in fused silica capillaries are presented. Although these buffers are commonly used in biological chemistry, these mobilities have not previously been reported. Strong agreement among data collected with both methods establishes confidence in the electroosmotic mobility values obtained and indicates that the current-based method, which requires less infrastructure than the direct method, can provide accurate flow rate measurements under these conditions. Constant electroosmotic mobilities of 4.90 x 10(-8) m(2) V(-1) s(-1) for TAE and 3.10 x 10(-8) m(2) V(-1) s(-1) for TBE were determined by tests in a range of electrical field strengths from 5 to 20 kV/m. A linear flow rate increase with applied field strength indicated that constant mobility and negligible Joule heating effects were present. Applicability and limitations of both the measurement methods and these buffers are discussed in the context of microfluidic applications.  相似文献   

19.
单级高压微流量电渗泵的研究   总被引:1,自引:0,他引:1  
陈令新  关亚风 《分析化学》2003,31(7):886-889
设计了一种高压微流量电渗泵。泵体主要由高压电源、电渗柱、毛细通道、导电空心电极以及气泡去除器、压力传感器等构成。单级电渗泵可以给出0~20MPa范围的输出压力和nL~μL级输出流量。输出压强和输出流量取决于电压、填充柱阻力和流体性质。  相似文献   

20.
2-DE proved to be a key technology in protein science since the two orthogonal separation dimensions are capable of protein isoform separation. Recently, Agilent introduced the OFFGEL 3100 fractionator for in solution IEF (off-gel) of proteins with the help of a 12- or 24-well frame. With this instrument also conventional focusing in IPG strips after passive in-tray rehydration can be performed. In this study, two novel IEF applications using the OFFGEL electrophoresis were developed. First, a sample cup was built and a cup-loading method for the OFFGEL device was implemented. Applying proteins via cup resulted in higher reproducibility and less protein loss compared with conventional in-tray rehydration loading. Especially, the recovery of basic and high-molecular-mass proteins seems to be favored by cup loading. These effects are more pronounced with low microgram sample amounts. Second, a 48-well OFFGEL frame was developed, which doubles the resolution of the commercially available 24-well frame. It is capable of separating proteins with small pI differences and shows potential for isoform/PTM separation.  相似文献   