首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 310 毫秒
1.
There is increasing interest in and demand for simultaneously monitoring pesticides as well as related degradation products (DPs) in natural waters, as the latter compounds can be even more toxic than the former ones. A method for determining parts per trillion levels of phenylurea herbicides and their DPs, that is their dealkylated forms and aromatic amines, is described. This method is based on solid-phase extraction with a Carbograph 4 cartridge followed by liquid chromatography (LC) with electrospray (ES) mass spectrometric detection. A study aimed at optimizing the response of the ES-MS detector for very weakly basic chloroanilines was conducted. Results showed that ion signal intensities of the above species were dependent on the composition of the LC mobile phase to an astonishing degree. At concentration levels of a few hundred ng/l, laboratory experiments showed that the aromatic amines considered here were mostly associated to dissolved humic acids (HAs) by both reversible and irreversible bindings. The addition of a reducing agent, i.e., NaBH4, succeeded in liberating that fraction of aromatic amines, which being reversibly bound to quinoidal structures of HAs are bioavailable. Analyte recoveries were better than 85% on extraction from 4 l of drinking water (spike level, 25 ng/l), 2 l of ground water (spike level, 50 ng/l) and 0.5 l of river water (spike level, 200 ng/l). Relative standard deviations ranged between 4.6 and 20% for drinking water, 4.3 and 15% for ground water, 5.9 and 13% for river water. Method detection limits calculated for drinking water, groundwater and surface water were between 3 and 11, 6 and 21, 36 and 75 ng/l, respectively.  相似文献   

2.
Summary A new method for the simultaneous identification and quantification of base/neutral and acidic pesticides at a low nanogram per liter concentration level in natural waters is presented. The method includes enrichment of the compounds by solid phase extraction on graphitized carbon black, followed by sequential elution of the base/neutral and acidic pesticides. Identification and quantification of the compounds is performed with HPLC-ESI-MS. This procedure involves passing 1 L of ground water and 2 L of drinking water samples through a 0.5 g graphitized carbon black (GCB) extraction cartridge. A conventional 4.6-mm-i.d. reversed phase LC C-18 operating with a 1 mL min−1 flow of the mobile phase was used to chromatograph the analytes. A flow of 100 μL min−1 of the column effluent was diverted to the ESI source. The ESI source was operated in positive ion mode for base/neutral pesticides and in negative-ion mode for acid pesticides. For the analyte considered, the response of the mass detector was linearly related to the amount of the analytes injected between 5 and 250 ng. In all cases, recoveries of the analytes were better than 90%. The limit of detection (signal-to-noise ratio=3) of the method for the pesticides considered in drinking water samples was estimated to be about 3–10 ng L−1.  相似文献   

3.
An evaluation was made of the feasibility of using reversed-phase liquid chromatography/tandem mass spectrometry with an electrospray interface (LC/ESI-MS/MS) to measure traces of phenoxyacid herbicides and their metabolites in surface and drinking water samples. The procedure involved passing 0.5 L of river and drinking water samples through a 0.5 g graphitized carbon black (GCB) extraction cartridge. Recovery was higher than 85% irrespective of the aqueous matrix in which the analytes were dissolved. A conventional 4.6-mm i.d. reversed-phase LC C-18 column operating with a mobile phase flow rate of 1 mL/min was used to chromatograph the analytes. A flow of 200 microL/min of the column effluent was diverted to the ESI source. The limits of detection (signal-to-noise ratio = 3) of the method for the pesticides considered in drinking and surface water samples are less than 0.1 ng/L for phenoxyacid herbicides, and about 5-10 ng/L for their metabolites (2,4-dichlorophenol and 4-chloro-2-methylphenol).  相似文献   

4.
A new analytical method is presented that allows simultaneous determination of neutral and acidic pharmaceuticals and pesticides in natural waters. The compounds investigated include frequently used pharmaceuticals, i.e., the anti-epileptic carbamazepine, four analgesic/anti-flammatory drugs (ibuprofen, diclofenac, ketoprofen and naproxen) and the lipid regulator clofibric acid and important pesticides including triazines, acetamides and phenoxy acids. Sample enrichment was achieved in one step with a newly developed solid-phase extraction procedure using the Waters Oasis HLB sorbent. The neutral compounds were analyzed by GC-MS in a first step, and then the acidic compounds after derivatization with diazomethane. Relative recoveries using isotope labeled internal standards were between 71 and 118% and the detection limits were in the range of 1 to 10 ng/l in drinking water, surface water and waste water treatment plant effluents (precision: 1-15%). The developed analytical method proved to be very durable during a 3-month field study and the target analytes were detected in concentrations of 5-3,500 ng/l in waste water treatment plant effluents, river water and lake water.  相似文献   

5.
This study investigated the effects of matrix interferences on the analytical performance of a triple quadrupole mass spectrometric (MS-MS) detector coupled to various reversed-phase liquid chromatographic (LC) modes for the on-line determination of various types of acidic herbicides in water using external calibration for quantification of the analytes tested at a level of 0.4 microg/l. The LC modes included (i) a single-column configuration (LC), (ii) precolumn switching (PC-LC) and (iii) coupled-column LC (LC-LC). As regards detection, electrospray (ESI) and atmospheric pressure chemical ionization (APCI) in both positive (PI) and negative (NI) ionization modes were examined. Salinity and dissolved organic carbon (DOC) were selected as interferences to study matrix effects in this type of analysis. Therefore, Milli-Q and tap water samples both fortified with 12 mg/l DOC and spiked with sulfometuron-methyl, bentazone, bromoxynil, 2-methyl-4-chlorophenoxyacetic acid, and 2-methyl-4-chlorophenoxypropionic acid at a level of about 0.4 microg/l were analyzed with the various LC-MS approaches. Direct sample injection was performed with volumes of 0.25 ml or 2.0 ml on a column of 2.1 mm I.D. or 4.6 mm I.D. for the ESI and APCI modes, respectively. The recovery data were used to compare and evaluate the analytical performance of the various LC approaches. As regards matrix effects, the salinity provided a dramatic decrease in response for early eluting analytes (k value of about 1) when using the LC mode. Both PC-LC and LC-LC efficiently eliminated this problem. The high DOC content hardly effected the responses of analytes in the ESI mode, while in most cases the responses increased when using APCI-MS-MS detection. Of all the tested configurations, LC-LC-ESI-MS-MS with the column combination Discovery C18/ABZ+ was the most favorable as regards elimination of matrix effects and provided reliable quantification of all compounds using external calibration at the tested low level. The major observed effects were verified with statistical evaluation of the data employing backwards ordinary least-square regression. All tested column-switching modes hyphenated to ESI- or APCI-MS-MS allowed the on-line multi-residue analysis of acidic pesticides in the reference water down to a level of 0.1 microg/l in less than 10 min, emphasizing the feasibility of such an approach in this field of analysis.  相似文献   

6.
Abstract

An automated on-line solid phase extraction procedure followed by liquid chromatography with diode array detection was investigated for the determination of different classes of pesticides in water samples containing varied amount of humic substances. The different pesticides used were: carbendazin, carbofuran, atrazine, diuron, propanil, molinate, alachlor, parathion-ethyl, diazinon, trifluralin and the degradation products deisopropylatrazine and deethylatrazine. Humic substances extracted from a Brazilian sediment were used from 5 to 80 mg/l and their influence on recoveries was evaluated in neutral and acidic media. Recoveries higher than 70% were obtained for all the pesticides, from the preconcentration of 75 ml of aqueous sample fortified at 2 ng/ml using precolumns packed with PLRP-S. Good recoveries were obtained at neutral pH for most of the analytes up to 40 mg/l of humic acid. Only at 80 mg/l the recoveries were significantly affected, both at acidic and neutral pH. The method was applied to the determination of pesticides in river water spiked at 0.1 to 1 ng/ml. Detection limits obtained for water containing 10 mg/l of humic acid were between 0.05 and 0.3 ng/ml.  相似文献   

7.
In this work we developed a sensitive and specific multiresidue method, based on reversed-phase liquid chromatography-mass spectrometry, with an ionspray interface (LC-ISI-MS), for determining 52 of most representative compounds of herbicides in water samples. The procedure used involved passing 0.5 l of surface water, 2 l of ground water and 4 l of drinking water samples, respectively, through a 0.5 g graphitized carbon black (GCB) extraction cartridge. Base-neutral and acid herbicides were differential eluted from GCB cartridge and follow analyzed by HPLC-ISI-MS apparatus. A conventional 4.6-mm-ID reversed-phase LC C18 column, operating with a mobile phase flow-rate of 1 ml/min, was used to chromatograph the analytes. A flow of 100 microl/min of the column effluent was diverted to the ISI source. The study demonstrates the sensitivity of the technique, with detection limit under 10 ng/l in drinking water samples. Performance data for the method such as recovery and precision are also reported.  相似文献   

8.
Varga R  Somogyvári I  Eke Z  Torkos K 《Talanta》2011,83(5):183-1454
Pharmaceuticals are emerging contaminants in surface water and they must be measured to follow their effects on the aquatic environment. We developed a solid-phase extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (SPE-LC-ESI-MS/MS) method for the determination of twenty-six pharmaceutical compounds - which belong to antihypertensive and anti-ulcer agents - from surface water samples. The selection of pharmaceuticals was based on usage frequency in Hungary. During method development Oasis HLB, SampliQ Polymer SCX and Si-SCX SPE cartridges were tested. As LC eluent ammonium formate, ammonium acetate buffers at pH 3 and 5 were investigated and for quantitation both matrix-matched and internal standard calibration was used. For matrix effect assessment post-extraction spike method was applied which can separate the extraction efficiency from ion suppression for better determination of recovery. Method detection limits (MDLs) varied between 0.2 and 10 ng/L. Precision of the method, calculated as relative standard deviation (RSD), ranged from 0.2 to 14.6% and from 1.2 to 22.4% for intra- and inter-day analysis, respectively. The method was applied to analyze Danube water samples. Measured average concentrations varied between 2 and 39 ng/L for eleven compounds and another one could be detected under LOQ.  相似文献   

9.
Two on-line SPE-LC-ESI-MS/MS methods have been developed for the rapid determination and confirmation of 18 polar pesticides and nine transformation products (TPs) in water samples. Given the very different physico-chemical characteristics of the analytes, it was not feasible the simultaneous determination of all selected compounds in only one method. Thus, it was necessary to use heptafluorobutyric acid and formic acid in order to obtain good retention in the SPE cartridge for basic and acidic analytes, respectively. The developed analytical methodology based on the direct injection of 2 mL of water sample in the system allowed the quantification of all analytes at the 25 ng/L level (LOQ) with limits of detection normally lower than 5 ng/L. Satisfactory recoveries (70-110%) were obtained for most compounds in ground and surface water samples. Some exceptions were found mainly in surface water, due to the ion suppression produced by the higher amount of matrix interferents in these samples. The acquisition of two MS/MS transitions for each compound allowed the reliable confirmation of positive findings even at the LOQ level. The developed methodology was applied to real ground and surface water samples showing the interest of including TPs in monitoring methods, as several of them were found at concentrations higher than that of parent compounds.  相似文献   

10.
建立了同时测定全血、尿液和肝组织等生物样品中18种氨基甲酸酯类农药的在线固相萃取/液相色谱-线性离子阱质谱(On-line SPE/LC-LIT/MS)分析方法。样品经乙腈处理,稀释和离心后直接进样。经Waters OasisHLB在线SPE柱富集纯化,以BETASIL C18柱为分析柱,甲醇-水(均含0.1%甲酸)为流动相进行梯度洗脱;使用电喷雾电离(ESI)正离子模式测定,扫描方式为选择反应监测(SRM)和连续反应监测(CRM)。18种农药在考察的质量浓度范围内线性关系良好(权重因子1/X),相关系数为0.994 3~0.999 4;在全血和尿液中的检出限为0.1~5 ng/m L,在肝组织中的检出限为0.1~5 ng/g;3个加标水平的回收率为90.2%~114.5%,相对标准偏差(n=4)为0.5%~7.5%。该方法简单准确,灵敏度高,能够满足生物样品中18种氨基甲酸酯类农药的快速分析要求。  相似文献   

11.
Ammonium perchlorate, a key ingredient in solid rocket propellants, has been found in ground and surface waters in a number of U.S. states, and perchlorate contamination of public drinking water wells is now a serious problem in California. Perchlorate poses a health risk and preliminary data from the U.S. EPA reports that exposure to less than 4-18 microg/l provides adequate human health protection. An improved ion chromatographic method was developed for the determination of low microg/l levels of perchlorate in ground and drinking waters based on a Dionex IonPac AS16 column, an hydroxide eluent generated using an EG40 automated eluent generator, large loop (1000 microl) injection, and suppressed conductivity detection. The method is free of interferences from common inorganic anions, linear over the range of 2-100 microg/l perchlorate, and quantitative recoveries are obtained for low microg/l levels of perchlorate in spiked ground and drinking water samples. The MDL of 150 ng/l permits quantification of perchlorate below the levels that ensure adequate health protection.  相似文献   

12.
A method for the determination of trace amounts of off-flavor compounds including 2-methylisoborneol, geosmin and 2,4,6-trichloroanisole in drinking water was developed using the stir bar sorptive extraction technique followed by thermal desorption-GC-MS analysis. The extraction conditions such as extraction mode, salt addition, extraction temperature, sample volume and extraction time were examined. Water samples (20, 40 and 60 ml) were extracted for 60-240 min at room temperature (25 degrees C) using stir bars with a length of 10 mm and coated with a 500 microm layer of polydimethylsiloxane. The extract was analyzed by thermal desorption-GC-MS in the selected ion monitoring mode. The method showed good linearity over the concentration range from 0.1 or 0.2 or 0.5 to 100 ng l(-1) for all the target analytes, and the correlation coefficients were greater than 0.9987. The detection limits ranged from 0.022 to 0.16 ng l(-1). The recoveries (89-109%) and precision (RSD: 0.80-3.7%) of the method were examined by analyzing raw water and tap water samples fortified at the 1 ng l(-1) level. The method was successfully applied to low-level samples (raw water and tap water).  相似文献   

13.
微波浓缩-离子法测定饮用水中的痕量溴酸根和高氯酸根   总被引:26,自引:0,他引:26  
刘勇建  牟世芬  杜兵  林爱武 《色谱》2002,20(2):129-132
 建立了一种简便的用于浓缩水中痕量BrO3 -和ClO4 -的样品前处理方法。水样经OnGuardAg柱过滤 ,用微波炉在 15min内可浓缩 2 0倍 ,所测离子的回收率均高于 90 %。又采用IonPacAS16型亲水性柱 ,用 15 0 μL定量环 ,以NaOH为流动相、梯度淋洗方式 ,在 35min内测定了包括BrO3 -和ClO4 -在内的 8种离子。BrO3 -和ClO4 -的检测限分别为 0 10 μg/L和 0 2 0 μg/L。该方法在实际应用中有较大的参考价值。  相似文献   

14.
Dispersive liquid-liquid microextraction (DLLME) combined with gas chromatography and mass spectrometry (GC-MS) was applied to the determination of six organophosphorous pesticides (OPPs) in water samples. The analytes included in this study were prophos, diazinon, chlorpyrifos methyl, methyl parathion, fenchlorphos and chlorpyrifos. Several extraction and dispersion solvents were tested for dispersive liquid-liquid microextraction of these analytes and the best results were obtained using chloroform as extraction solvent and 2-propanol as dispersion solvent. Calibration curves of the analytes in water samples were constructed in the concentration range from 100 to 1100 ng/L for prophos, diazinon and methyl parathion and in the range from 100 to 1000 ng/L for chlorpyrifos methyl, fenchlorphos and chlorpyrifos. Limits of detection (LODs) were in the range of 1.5-9.1 ng/L and limits of quantification (LOQs) were in the range of 5.1-30.3 ng/L, below the maximum admissible level for drinking water. Relative standard deviations (RSDs) were between 6.5 and 10.1% in the concentration range of 100-1000 ng/L. The relative recoveries (%RRs) of tap, well and irrigation water samples fortified at 800 ng/L were in the range of 46.1-129.4%, with a larger matrix effect being detected in tap water.  相似文献   

15.
The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2 1 samples spiked with a test mixture of oxamyl, methomyl and aldicarb sulfoxide were enriched on EnviCarb SPE cartridges or 47 mm diameter EACD and eluted with dichloromethane-methanol. After evaporation, a sample was injected onto a C18-bonded silica column and analysed by liquid chromatography with ultraviolet (LC-UV) detection. EACD performed better than EnviCarb cartridges in terms of breakthrough volumes (>2 1 for all test analytes), reproducibility (R.S.D. of recoveries, 4–8%, n=3) and smapling speed (100 ml/min); detection limits in drinking water were 0.05–0.16 μg/l. In the on-line experiments, 4.6 mm diameter pieces cut from original EACD and stacked onto each other in a 9 mm long precolumn, and EnviCarb and CPP-50 packed in 10×2.0 mm I.D. precolumn, were tested, and 50–200 ml spiked water samples were preconcentrated. Because of the peak broadening caused by the strong sorption of the analytes on carbon, the carbon-packed precolumns were eluted by a separate stream of 0.1 ml/min acetonitrile which was mixed with the gradient LC eluent in front of the C18 analytical column. The final on-line procedure was also applied for the less polar propoxur, carbaryl and methiocarb. EnviCarb could not be used due to its poor pressure resistance. CPP-50 provided less peak broadening than EACD: peak widths were 0.1–0.3 min and R.S.D. of peak heights 4–14% (n = 3). In terms of analyte trapping efficiency on-line SPE-LC-UV with a CPP-50 precolumn also showed better performance than when Bondesil C18/OH or polymeric PLRP-S was used, but chromatographic resolution was similar. With the CPP-50-based system, detection limits of the test compounds were 0.05–1 μg/l in surface water.  相似文献   

16.
A convenient and sensitive method for the simultaneous determination of trace level of bromate and chlorinated haloacetic acids in bottled drinking water with ion chromatography is presented. With a high capacity anion-exchange column and 11.5 mmol/l Na2CO3 eluent, all the 16 analytes could be separated in one injection within 31 min. By employing a microwave based evaporation technique, the bottled drinking water sample could be concentrated tenfold in 10 min. The recoveries of the compounds ranged from 90.6 to 107.2%. With a 500 μl large volume injection and high performance anion Atlas electrolytic suppressor, the detection limits were 0.06, 0.08, 0.06, 0.14 and 0.85 μg/l for BrO3, ClO3, monoacetic acid, dichloroacetic acid and trichloroacetic acid, respectively.  相似文献   

17.
Solid-phase extraction combined with dispersive liquid-liquid microextraction (SPE-DLLME) was applied for the extraction of six organophosphorous pesticides (OPPs) in water samples. The analytes considered in this study were determined by gas chromatography with mass spectrometry and included prophos, diazinon, chlorpyrifos methyl, methyl parathion, fenchlorphos and chlorpyrifos. Several extraction conditions (extraction solvent and elution/dispersion solvents nature, extraction solvent volume, elution solvent volume, water volume and sample volume) were tested for SPE-DLLME with these analytes and the best results were obtained using carbon tetrachloride as the extraction solvent and acetone as the elution/dispersion solvent. Calibration curves for the determination of OPPs in water samples were constructed in the concentration range of 10-100 ng/L. Limits of detection (LODs) ranged from 38 to 230 pg/L values that are below the maximum admissible level for drinking water (100 ng/L). Relative standard deviations (RSD) were between 8.6 and 10.4% for a fortification level of 100 ng/L. At the same fortification level, the relative recoveries (R.R.) of tap, well and irrigation water samples were in the range of 30.2-97.1%.  相似文献   

18.
The present work describes a fully automated method based on online solid phase extraction–liquid chromatography–tandem mass spectrometry for the determination of different classes of pesticides, including acidic and polar pesticides and six thiamethoxam metabolites. Sample preconcentration was performed by extracting 4 mL of the sample with a single styrene-divinylbenzene polymer. Elution of the compounds was done within the high performance liquid chromatography gradient and tandem mass spectrometry determination was performed in the selected reaction monitoring mode, by recording 1–3 transitions per compound. The overall pretreatment and analysis time per sample was less than 15 min. Method validation was performed in drinking, ground and surface water. For nearly all compounds a recovery between 70% and 120% could be achieved. The limit of detection ranges from 1.2 to 18 ng/L in drinking water and 3.0 to 23 ng/L in ground and surface water. The correlation coefficients for a calibration range of 0.05–2 µg/L are between 0.9915 and 0.9999. The limit of quantification (LOQ) for all compounds lies below the required limit of 0.1 µg/L, to fulfil the Council Directive 98/83/EC. Most of the compounds easily reach an LOQ below 0.05 µg/L.  相似文献   

19.
建立了高氯、高钠油田回注水中痕量无机阴、阳离子和有机酸的离子色谱分析方法。对高钠基质中痕量阳离子的测定,选用IonPac CS12A分析柱、H2SO4溶液梯度淋洗、电导检测器检测;对高氯基质中阴离子及有机酸的测定,选用对OH-具有高选择性的高容量的IonPac AS11-HC柱、KOH梯度淋洗、电导检测器检测。在优化的梯度淋洗条件下,高氯或高钠的存在不影响痕量阴离子或阳离子的测定。该方法具有良好的线性(r=0.9926~0.9990)和精密度(测定组分峰面积的相对标准偏差(n=7)在8.0%以下),回收率  相似文献   

20.
多壁纳米碳管固相萃取测定水中的有机氯农药   总被引:7,自引:3,他引:7  
对于水样中的有机氯农药的净化方法主要是采用传统的液液分配的方法,缺点是溶剂使用量和前处理复杂。近年来固相萃取及固相微萃取等技术被应用到水样中的有机污染物的测定。如利用键合在硅胶上的非极性(C18,LC18等)或极性物质(LC-CN,LC-NH2)对水中有机物进行富集,用GDX或XAD自填的固相柱的报道也很多。纳米技术和纳米材料的发展为开发固相萃取材料带来新契机。纳米材料是指尺寸大小在从1~100m之间物质。与普通的块体材料相比,纳米材料具有较大的比表面,因而有可能具有较大吸附容量。纳米材料在环境有机污染物分离富集方面的应用研究才刚刚开始。本文主要就纳米碳管对水样中的有机氯农药进行研究,优化固相萃取条件。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号