首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
Graphene‐based pipette tip solid‐phase extraction was combined with ultra‐high performance liquid chromatography and tandem mass spectrometry for the determination of carbamate pesticide residues in fruit juice samples. Four milligrams of graphene was used as sorbent material to pack a 1000 μL pipette tip for the extraction of pirimicarb, propoxur, isoprocarb, fenobucarb, and diethofencarb from 3 mL of fruit juice sample. The whole extraction process was finished in 12 min, and the volume of eluent used was only 1.5 mL. Under the optimized conditions, good linear relationship (R > 0.999) and lower limits of detection (0.0022–0.033 ng/mL) were achieved. The recoveries at three spiked levels ranged from 80.90 to 124.60% with relative standard deviations less than 4.88%. Compared with commercially available sorbents including propylsulfonic acid silica, graphitized carbon black, and C18, graphene was superior in extraction efficiency. The proposed method is simple, rapid, sensitive, selective, and solvent saving.  相似文献   

2.
In the current work, the Cu-based metal-organic framework (MOF) (Cu-BDC) was synthesized through a simple and one-pot solvothermal method and used as a sorbent for dispersive solid-phase extraction (DSPE) of gallic acid (GA) from orange juice samples followed by high-performance liquid chromatography-ultraviolet (HPLC-UV) determination. The prepared Cu-BDC was fully characterized using different analysis including Fourier-transform infrared spectroscopy (FT-IR), X-ray Powder Diffraction (XRD), Scanning Electron Microscopy (SEM), Energy-dispersive X-ray spectroscopy (EDS) and Brunauer-Emmett-Teller (BET). The prepared Cu-BDC had exceptional properties in terms of high specific surface area (400 m2 g−1) and high adsorption capacity (300 mg g−1) toward GA. The influence of effective factors on extraction recovery of GA such as sorbent dosage, ultrasonic time, washing solvent volume and eluent solvent volume was evaluated using a central composite design (CCD) based response surface methodology (RSM). Under the optimized conditions, the presented method showed a wide linear range of 0.5–15.0 mg L−1 with a detection limit of (0.145 mg L−1) and acceptable repeatability (RSD < 6.0%) which shows the applicability of the proposed method for accurate determination of GA from complicated orange juice samples.  相似文献   

3.
A simple and rapid method using microextraction by packed sorbent coupled with gas chromatography and mass spectrometry has been developed for the analysis of five phthalates, namely, diethyl phthalate, benzyl‐n‐butyl phthalate, dicyclohexyl phthalate, di‐n‐butyl phthalate, and di‐n‐propyl phthalate, in cold drink and cosmetic samples. The various parameters that influence the microextraction by packed sorbent performance such as extraction cycle (extract–discard), type and amount of solvent, washing solvent, and pH have been studied. The optimal conditions of microextraction using C18 as the packed sorbent were 15 extraction cycles with water as washing solvent and 3 × 10 μL of ethyl acetate as the eluting solvent. Chromatographic separation was also optimized for injection temperature, flow rate, ion source, interface temperature, column temperature gradient and mass spectrometry was evaluated using the scan and selected ion monitoring data acquisition mode. Satisfactory results were obtained in terms of linearity with R2 >0.9992 within the established concentration range. The limit of detection was 0.003–0.015 ng/mL, and the limit of quantification was 0.009–0.049 ng/mL. The recoveries were in the range of 92.35–98.90% for cold drink, 88.23–169.20% for perfume, and 88.90–184.40% for cream. Analysis by microextraction by packed sorbent promises to be a rapid method for the determination of these phthalates in cold drink and cosmetic samples, reducing the amount of sample, solvent, time and cost.  相似文献   

4.
A new method for quantification of 12 nitroaromatic compounds including 2,4,6‐trinitrotoluene, its metabolites and 2,4,6‐trinitrophenyl‐N‐methylnitramine with microextraction by packed sorbent followed by gas chromatography and mass spectrometric detection in environmental and biological samples is developed. The microextraction device employs 4 mg of C18 silica sorbent inserted into a microvolume syringe for sample preparation. Several parameters capable of influencing the microextraction procedure, namely, number of extraction cycles, washing solvent, volume of washing solvent, elution solvent, volume of eluting solvent and pH of matrix, were optimized. The developed method produced satisfactory results with excellent values of coefficient of determination (R2 > 0.9804) within the established calibration range. The extraction yields were satisfactory for all analytes (> 89.32%) for aqueous samples and (> 87.45%) for fluidic biological samples. The limits of detection values lie in the range 14–828 pg/mL.  相似文献   

5.
In the present study, we have developed a method based on pressurized liquid extraction (PLE) and liquid chromatography with fluorescence detection (LC-FLD) for the determination of residues of fluoroquinolones (FQs) in infant food products. PLE extraction has been optimized by the application of experimental design methodologies. Initially, a fractional factorial design (FFD) was used to screen the significance of four extraction parameters: solvent composition, temperature, pressure and number of cycles. The most significant factors, identified by ANOVA analysis, were the solvent composition, temperature and pressure, which were further optimized with the aid of a face centred design (FCD) and the desirability function. The optimized operating PLE conditions were as follows: ACN/o-phosphoric acid 50 mM pH 3.0 (80:20, v/v), 80 °C, 2000 psi and three extraction cycles of 5 min. Under these conditions, recoveries of the target FQs varied between 69% and 107% with RSDs below 9%. The whole method was validated according to the Commission Decision 2002/657/EC guidelines. The proposed method has been successfully applied to the analysis of different infant food products bought in local supermarkets and pharmacies. The results showed the presence of residues of enrofloxacin in a non-compliant baby food sample corresponding to a chicken-based formulation, which were also confirmed and quantified by LC–MS/MS analysis.  相似文献   

6.
A simple, rapid and efficient method termed dispersive liquid–liquid microextraction combined with liquid chromatography-fluorescence detection, has been developed for the extraction and determination of polycyclic aromatic hydrocarbons (PAHs) in water and fruit juice samples. Parameters such as the kind and volume of extraction solvent and dispersive solvent, extraction time and salt effect were optimized. Under optimum conditions, the enrichment factors ranged from 296 to 462. The linear range was 0.01–100 μg L?1 and limits of detection were 0.001–0.01 μg L?1. The relative standard deviations (RSDs, for 5 μg L?1 of PAHs) varied from 1.0 to 11.5% (n = 3). The relative recoveries of PAHs from tap, river, well and sea water samples at spiking level of 5 μg L?1 were 82.6–117.1, 74.9–113.9, 77.0–122.4 and 86.1–119.3%, respectively. The relative recoveries of PAHs from grape and apple juice samples at spiking levels of 2.5 and 5 μg L?1 were 80.8–114.7 and 88.9–123.0%, respectively. It is concluded that the proposed method can be successfully applied for determination of PAHs in water and fruit juice samples.  相似文献   

7.
In the present study, a natural sorbent based micro-solid phase extraction (μ-SPE) was developed for determination of phthalate esters in milk samples. For the first time, an efficient and cost effective natural material (seed powder of Moringa oleifera) was employed as sorbent in μ-SPE. The sorbent was found to be naturally enriched with variety of functional groups and having a network of interconnected fibers. This method of extraction integrates different steps such as removal of proteins and fatty stuff, extraction and pre-concentration of target analytes into a single step. Thirteen phthalate esters were selected as target compounds for the development and evaluation of method. Some key parameters affecting the extraction efficiency were optimized, including selection of membrane, selection and amount of sorbent, extraction time, desorption solvent, volume of desorption solvent, desorption time and effect of salt addition. Under the optimum conditions, very good linearity was achieved for all the analytes with coefficient of determinations (R2) ranging between 0.9768 and 0.9977. The limits of detection ranged from 0.01 to 1.2 μg L−1. Proposed method showed satisfactory reproducibility with relative standard deviations ranging from 3.6% to 10.2% (n = 7). Finally, the developed method was applied to tetra pack and bottled milk samples for the determination of phthalate esters. The performance of natural sorbent based μ-SPE was better or comparable to the methods reported in the literature.  相似文献   

8.
张咏  梅萌  刘祎  喻杰  黄晓佳  袁东星 《色谱》2014,32(9):981-987
以3-丙烯酰胺苯硼酸(APB)为单体,二乙烯基苯(DVB)为交联剂,“原位”聚合制备了聚(3-丙烯酰胺苯硼酸-二乙烯基苯)多孔硼亲和整体材料并作为搅拌饼固相萃取(SCSE-APBDVB)的萃取介质。以5种苯甲酰脲农药为目标化合物,详细考察了萃取过程中解吸溶剂、样品基底中pH值以及离子强度、萃取和解吸时间等实验条件对萃取效率的影响。在此基础上,与高效液相色谱-二极管阵列检测器联用建立了环境水样和果汁样品中苯甲酰脲农药残留的测定方法。在最佳条件下,在水样和果汁样品中,5种目标化合物的检出限(LOD,S/N=3)分别在0.055~0.11 μg/L和0.095~0.31 μg/L之间,所建立的方法具有理想的日内和日间重现性(RSD值均小于9.0%)。在对实际环境水样和果汁样品的测定中,不同加标浓度苯甲酰脲的回收率为75.6%~109%。研究表明,由于所制备吸附剂与目标化合物存在B-N配位作用、氢键和疏水等多种作用力,因此SCSE-APBDVB可对苯甲酰脲农药进行有效萃取,所建立的分析方法具有简便、灵敏和环境友好等特点。  相似文献   

9.

In this paper, a novel pipette tip micro-solid phase extraction based on molecularly imprinted polymer as a selective sorbent was developed and applied for extraction, pre-concentration and high-performance liquid chromatographic determination of trace amounts of malachite green (MG), rhodamine B (RB), methyl orange (MO) and acid red 18 (AR) dyes in seawater samples. Different parameters affecting the extraction efficiency such as type and volume of eluent solvent, sample volume, number of cycles of extraction and desorption, amount of sorbent and pH of the sample solution were evaluated using one-variable-at-a-time and response surface methodology. In order to optimize dyes extraction, seven factors in three levels were used for Box–Behnken experimental design. Under optimum extraction condition, pH of sample solution was 3.1 for MG, 3.0 for RB, 7.1 for MO and 6.1 for AR; volume of eluent solvent (HCl, 0.5 mol L−1) was 200 µL; volume of the sample solution was 10 mL (for MG) and 4 mL (for RB, MO and AR); the concentration of triton X-114 was 0.085 (MG), 0.10 (RB), 0.08 (MO) and 0.075 (AR) % v/v; the number of extraction cycles was 10 (MG), 6 (RB), 5 (MO) and 7 (AR); the number of elution cycles was 10, 6, 5 and 9, respectively, for MG, RB, MO and AR; NaCl concentration was 0.4 mol L−1; and amount of MIP was 2.0 mg for all dyes. The linear range of calibration curves was 0.5–250.0 µg L−1 for malachite green and methyl orange and 0.5–150.0 µg L−1 for both rhodamine B and acid red 18. The detection limits calculated to be 0.083, 0.10, 0.12 and 0.17 µg L−1 for MG, RB, MO and AR, respectively. The developed protocol was successfully used for determination of dyes in seawater of Chabahar Bay. The mean recoveries were ranged between 76.1 and 97.3% by mean relative standard deviations of 1.2–7.1%.

  相似文献   

10.
A sensitive, economical, and miniaturized self-assembly pipette tip graphene solid-phase extraction (PT-G-SPE) coupled with liquid chromatography fluorescence detection (LC-FD) was developed for rapid extraction and determination of three sulfonamide antibiotics (SAs) in environmental water samples. The PT-G-SPE cartridge, assembled by packing 1.0 mg of graphene as sorbent into a 100 μL pipette tip, showed high adsorption capacity for the SAs owing to the large surface area and unique structure of graphene. The factors that affected the extraction efficiency of PT-G-SPE, including sample volume, pH, sorbent amount, washing solvent and eluent solvent were optimized. Good linearity for SAs was obtained in a range of 2–4000 pg mL−1 with correlation coefficients (r2) ≥ 0.9993. The recoveries of the SAs at three spiked levels ranged from 90.4% to 108.2% with relative standard deviations (RSD) ≤ 6.3%. In comparison with other sorbents such as C18, HLB, SCX, PCX, and multiwalled carbon nanotubes, one advantage of using graphene as sorbent of pipette tip solid-phase extraction (PT-SPE) was that PT-G-SPE could adsorb larger sample volume (10 mL) at a small amount of sorbent (1 mg) and low solvent consumption with good extraction efficiency, which not only increased the fraction of analytes to LC and the sensitivity of SAs determination, but also reduced the cost and pollution.  相似文献   

11.
A rapid and sensitive method has been developed for the simultaneous determination of four avermectins and one milbemycin residues in bovine tissue. The isolation of the analytes from muscle and liver samples was accomplished utilizing a pressurized solvent extractor. The optimized extraction procedure using acetonitrile/water (40:60, v/v) as extraction solvent, was automatically carried out at 100 °C and 10 MPa, applying two static cycles for 3 min. The extracts were cleaned up on a C18 solid-phase extraction cartridge and analyzed by liquid chromatography with fluorescence detection after derivatization. Mean recoveries of the five analytes from fortified samples were between 84.8 and 101.8%, with relative standard deviations lower than 10.8%. The limit of detection and quantification were in the ranges of 0.1–0.2 and 0.5–0.6 μg kg–1, respectively. The application of the newly developed method was demonstrated by analyzing bovine meat samples from market.  相似文献   

12.
In this study, combined technique of solid-phase extraction based on multi-walled carbon nanotubes with bio-coacervation extraction (SPE-MWCNT-BCAE) has been developed as a new sample preparation method for the determination of atrazine from water samples. The proposed method involves two steps: analyte enrichment on the solid sorbent and subsequently elution of the analyte by an appropriate solvent. Multi-walled carbon nanotubes (MWCNTs) were used as the sorbent. They have high specific surface area, nano-scale structure and high diffusion rate. The second step is based on the use of bioaggregates for analyte re-enrichment, which consists of biosurfactants and ionic liquid. This method follows the principles of green chemistry. Parameters affecting the extraction efficiency were optimized. Under optimum conditions, the enrichment factor was 176. The linear dynamic range (LDR) and limit of detection (LOD) were 2–100 µg L?1 and 0.66 µg L?1, respectively. The relative standard deviation (RSD) for six replicate measurements was 3.8%. The method was applied to the determination of ultratrace levels of atrazine in environmental water samples with satisfactory results.  相似文献   

13.
Microextraction by packed sorbent, a miniaturized form of the solid‐phase extraction, is a new sample pretreatment technology mainly used for bioanalysis. In this work, self‐made device was fabricated by packing C18 sorbent into a microinjection needle (50 μL) and then applied for the analysis of polychlorinated biphenyls in bovine serum followed by gas chromatography with mass spectrometry determination. Compared with conventional solid‐phase extraction, the developed method bears many intriguing properties such as low consumption of the sample and organic solvent, time‐saving and easy operation, which are of great interest and desire for bioanalysis applications. A series of parameters that affect the analytical performance, such as the type of elution, the aspirating/dispensing cycles of sample loading and elution, washing solution, and matrix effects, was investigated in detail. Under the optimized conditions, the proposed method presented a good linearity (R ≥ 0.986) and satisfactory sensitivity and limits of detection (0.06–0.53 ng/mL) and quantification (0.20–1.77 ng/mL), respectively. In addition, satisfactory recoveries (60.0–91.4%) and accuracy (RSD ≤ 5.72%) were achieved after optimizing the conditions when applying the developed method to real sample analysis. The screening of polychlorinated biphenyls residues in bovine serum samples by the developed method demonstrated that the assay is ideally suited as a monitoring method for polychlorinated biphenyls residues in bioanalysis.  相似文献   

14.
A solid‐phase nanoextraction method has been developed for the extraction and preconcentration of polychlorinated biphenyls using carboxyl multiwalled carbon nanotubes as a solid nano‐sorbent. Parameters affecting extraction efficiency such as sorbent amount, desorption solvent type and volume, extraction time, pH, and salt content have been studied. Under optimized conditions, the correlation coefficient was up to 0.9989, the limits of detection was in the range of 1.4–3.5 ng/L, and limits of quantification was between 4.8 and 11.6 ng/L. The recoveries were in the range of 99–106% for different spiked analytes. The relative standard deviation for water samples spiked with two different spiking levels has been between 4 and 10%. The proposed sustainable method is rapid, easy to use, and small consumption of organic solvent for the detection and determination of trace levels of polychlorinated biphenyls in environmental waters.  相似文献   

15.
建立了气相色谱-质谱法(GC-MS/SIM)同时测定蔗汁样品中莠去津和莠灭净的方法,并优化了样品前处理和色谱条件.在优化条件下,两种除草剂在0.00-0.60 mg/L范围内线性关系良好,方法的检出限(S/N=3)均为0.001 mg/L.在加标水平为0.050-0.100 mg/L时,两种除草剂的回收率在93%-10...  相似文献   

16.
A β‐cyclodextrin‐modified attapulgite composite was prepared and used as a dispersive micro‐solid‐phase extraction sorbent for the determination of benzoylurea insecticides in honey samples. Parameters that may influence the extraction efficiency, such as the type and volume of the eluent, the amount of the sorbent, the extraction time and the ionic strength were investigated and optimized using batch and column procedures. Under optimized conditions, good linearity was obtained for all of the tested compounds, with R2 values of at least 0.9834. The limits of detection were determined in the range of 0.2–1.0 μg/L. The recoveries of the four benzoylurea insecticides in vitex honey and acacia honey increased from 15.2 to 81.4% and from 14.2 to 82.0%, respectively. Although the β‐cyclodextrin‐modified attapulgite composite did not show a brilliant adsorption capacity for the selected benzoylurea insecticides, it exhibited a higher adsorption capacity toward relatively hydrophobic compounds, such as chlorfluazuron and hexaflumuron (recoveries in vitex honey samples ranged from 70.0 to 81.4% with a precision of 1.0–3.7%). It seemed that the logPow of the benzoylurea insecticides is related to their recoveries. The results confirmed the possibility of using cyclodextrin‐modified palygorskite in the determination of relatively hydrophobic trace pharmaceutical residues.  相似文献   

17.
An ultrasound-assisted emulsification-microextraction (USAEME) procedure was developed for the extraction of US EPA 16 polycyclic aromatic hydrocarbons (PAHs) in 10 mL of water samples, with subsequent determination by gas chromatography-mass spectrometry (GC-MS). After determination of the most suitable solvent and solvent volume, several other parameters (i.e., extraction time, centrifugation time and ionic strength of the sample) were optimized using a 23 factorial experimental design. Limits of detection ranged from 0.001 to 0.036 μg L−1. The developed procedure was applied to fortified distilled water with different fortification levels (0.5, 2 and 5 μg L−1). Recoveries were over 92% and relative standard deviations of the recoveries were below 8%. The efficiency of the USAEME was compared with traditional liquid-liquid extraction (LLE) and solid-phase extraction on real water samples (i.e., tap water, well water and surface (lake) water as well as domestic and industrial wastewaters). The USAEME showed comparable efficiencies especially with LLE. The developed USAEME was demonstrated to be robust, viable, simple, rapid and easy to use for the determination of PAHs in water samples by GC-MS.  相似文献   

18.
An effective magnetic solid-phase extraction method was proposed using magnetic graphene oxide coated with poly(2-aminoterephthalic acid-co-aniline) as a sorbent for preconcentration and extraction of organophosphorus pesticides from environmental water and apple juice samples, and determined using the gas chromatography-mass spectrometry analysis. To approve the successful synthesis of the magnetic nanocomposite, the prepared sorbent was characterized by field emission scanning electron microscopy, X-ray diffraction, vibrating sample magnetometer, and Fourier transforms infrared techniques. The main parameters affecting the extraction efficiency were considered and studied to afford an optimized procedure. Systematic method validation verified its suitable recoveries (89.4–107.3%), and precision (relative standard deviations < 6.8%). The method showed a wide linear dynamic range (0.04–700 ng/mL) with low limits of detection (0.01–0.06 ng/mL) and quantification (0.04–0.21 ng/mL). This method presented good potential and great sensitivity for the pesticides determination.  相似文献   

19.
In this article, the use of magnetically separable sorbent polyaniline/silica‐coated nickel nanoparticles is evaluated under a dispersive micro‐solid‐phase extraction approach for the extraction of phenolic compounds from water samples. The sorbent was prepared by in situ chemical polymerization of aniline on the surface of silica‐modified nickel nanoparticles and was characterized by Fourier transform infrared spectroscopy, transmission electron microscopy, X‐ray powder diffraction, scanning electron microscopy, energy‐dispersive X‐ray spectrometry, and vibrating sample magnetometry. Effective variables such as amount of sorbent (milligrams), pH and ionic strength of sample solution, volume of eluent solvent (microliters), vortex, and ultrasonic times (minutes) were investigated by fractional factorial design. The significant variables optimized by a Box–Behnken design were combined by a desirability function. Under the optimized conditions, the calibration graphs of analytes were linear in a concentration range of 0.02–100 μg/mL, and with correlation coefficients more than 0.999. The limits of detection and quantification were in the ranges of 10–23 and 33–77 μg/L, respectively. This procedure was successfully employed in the determination of target analytes in spiked water samples; the relative mean recoveries ranged from 96 to 105%.  相似文献   

20.
In present study, a convenient, sensitive and environmentally friendly method for the determination of five benzoylurea insecticides (BUs) in water and juice samples was developed. To extract trace benzoylurea insecticides effectively, poly(methacrylic acid-co-ethylene dimethacrylate) monolith was prepared and used as the sorbent of multiple monolithic fiber solid-phase microextraction (MMF-SPME). The influences of preparation conditions of monolith and extraction parameters of MMF-SPME on BUs were studied thoroughly. Under the optimized conditions, the combination of MMF-SPME with high performance liquid chromatography-diode array detection (MMF-SPME-HPLC-DAD) showed expected analytical performance for target analytes. The limits of detection (S/N = 3) of the developed method were 0.026–0.075 μg L−1 in water and 0.053–0.29 μg L−1 in juice samples. Good linearity was obtained for analytes with the correlation coefficients (R2) above 0.99. Satisfactory repeatability and reproducibility was achieved, with relative standard deviations (RSD) of both less than 10%. Finally, the established MMF-SPME-HPLC-DAD method was successfully applied for the determination of BUs residues in juice and environmental water samples. Recoveries obtained for the determination of BUs in spiking samples ranged from 65.1% to 118%, with RSD below 10% in all cases.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号