首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
关于金属卟啉、酞菁等化学修饰电极的研究已有大量工作发表.这类电极很不稳定,例如著名的面-面双钴卟啉修饰电报,虽然能直接催化氧还原为水,但经受不住几次电位扫描就失去催化活性.因此,如何提高稳定性就成为研究这类电极的关键.近年来有人报道,吸附在活性碳上的金属卟啉、酞菁类化合物经热处理,可改善其稳定性。热处理后得到的粉状碳催化剂,由于完全不溶于水及有机溶剂,制备电极非常困难。曾有过用这种  相似文献   

2.
A glassy carbon electrode modified with palladium/gold nanoparticles was successfully prepared by an electrodeposition process. It efficiently oxidizes hydrazine at a low overpotential of ?0.26 V versus SCE. The Pd‐AuNPs with an average size of 50–80 nm are uniformly dispersed at the GCE. The Pd‐AuNPs/GCE was used for determination of hydrazine in phosphate buffer solution of pH 7.0. The amperometric current response of the electrode was increased linearly over a hydrazine concentration of 0.1–500 µM with a limit of detection of 0.07 µM .The prepared hydrazine sensor exhibited high sensitivity, good selectivity reproducibility and long term stability.  相似文献   

3.
Hou W  Wang E 《Talanta》1991,38(5):557-560
The dispersion of alumina particles on a glassy-carbon surface serving as a modified electrode significantly enhances the amperometric detection of cysteine and glutathione following liquid chromatography. With an applied potential of 0.8 V vs. SCE, the detection limits were 1.2 ng for cysteine and 8 ng for glutathione and the electrode response was linear up to 600 ng for cysteine and 1.8 mug for glutathione. The modified electrode displayed high sensitivity and stability and was easy and inexpensive to prepare.  相似文献   

4.
A graphite electrode modified with cobalt hexacyanoferrate by mechanical immobilization was used for amperometric determination of hydrazine. The modified electrode exhibits good catalytic activity for the oxidation of hydrazine at a reduced overpotential with remarkable sensitivity. The modified electrode showed a linear response for hydrazine in the concentration range of 2.0 × 10–5 to 2.8 × 10–4 M. The detection limit was 9.8 × 10–6 M (S/N = 3). The proposed modified electrode was simple, sensitive, rapid, stable and promising.  相似文献   

5.
Zhou J  Wang E 《Talanta》1993,40(6):943-948
A glassy carbon electrode coated with an electrodeposited film of mixed-valent cobalt oxide/cyanocobaltate (CoO/CNCo) enabled hydrazine compounds to be catalytically oxidized at the greatly reduced overpotential and in a wide operational pH range (pH 2.0-7.0). Electrocatalytic activity at the CoO/CNCo modified electrode was evaluated with respect to solution pH, film thickness, supporting electrolyte ions, potential scan rate, operating potential, concentration dependence and other variables. The CoO/CNCo film electrode was completely compatible with a conventional reversed-phase liquid chromatographic (RP-LC) system. Practical RP-LC amperometric detection (RP-LCEC) of hydrazines was performed. A dynamic linear response range over three orders of magnitude and a detection limit at the pmol level were readily obtained. The CoO/CNCO film electrode exhibited excellent electrocatalytic stability in the flowing streams.  相似文献   

6.
张连明  李建平  韦革 《应用化学》2012,29(10):1199-1205
将镍粒子表面功能化,合成了磁性纳米铁氰化镍(NiHCF)粒子,制备了磁性NiHCF修饰磁控玻碳电极。 在pH=7.4的磷酸盐缓冲溶液中,磁性NiHCF纳米粒子修饰电极对水合肼氧化有显著的催化作用,NiHCF的氧化峰电流与水合肼浓度在0~1.29×10-4 mol/L范围内呈良好的线性关系(安培法),检出限为2.1×10-8 mol/L。 研究了磁性NiHCF粒子修饰电极对水合肼的电化学响应以及电极的性能,并将其应用于水样中肼的测定。 该修饰电极具有灵敏度高、选择性好、电极易更新、稳定性好和制作简单等优点。  相似文献   

7.
Sol-gel technique was used for construction of a carbon composite electrode. The prepared carbon ceramic electrode was modified with electroless deposition of chlorogenic acid for less than 1 min. The adsorbed thin films of chlorogenic acid on carbon composite electrode show one pair of peaks with a surface confined characteristic, which strongly depends on the solution pH, as anticipated for quinone /hydroquinone functionalities. The modified electrode shows highly catalytic activity toward hydrazine electrooxidation at wide pH range (5–11). Also the rotating modified electrode shows excellent analytical performance for amperometric determination of hydrazine. The detection limit, sensitivity, response time and linear dynamic range are 20 nM, 220 nA / μM, 1 second and 0.1 μM-1 mM, respectively. The catalytic rate constant for hydrazine oxidation at the surface of modified electrode was evaluated by cyclic voltammetry and was found to be around 1.5×103 M−1s−1in phosphate buffer solution (pH 8). The precision of chronoamperometric measurements was 1–3% for 5 replicate determinations in the concentration range of the linear calibration. The reproducibility of modified CCE was evaluated with 8 successive polishing and modifications and then the anodic peak current was measured (RSD 2%). The advantages of this sensor are excellent catalytic activity, high sensitivity, good reproducibility and simplicity of preparation at short time periods.  相似文献   

8.
于浩  郑建斌 《中国化学》2007,25(4):503-509
A copper hexacyanoferrate modified ceramic carbon electrode (CuHCF/CCE) had been prepared by two-step sol-gel technique and characterized using electrochemical methods. The resulting modified electrode showed a pair of well-defined surface waves in the potential range of 0.40 to 1.0 V with the formal potential of 0.682 V (vs. SCE) in 0.050 mol·dm^-3 HOAc-NaOAc buffer containing 0.30 mol·dm^-3 KCl. The charge transfer coefficient (a) and charge transfer rate constant (ks) for the modified electrode were calculated. The electrocatalytic activity of this modified electrode to hydrazine was also investigated, and chronoamperometry was exploited to conveniently determine the diffusion coefficient (D) of hydrazine in solution and the catalytic rate constant (kcat). Finally, hydrazine was determined with amperometry using the resulting modified electrode. The calibration plot for hydrazine determination was linear in 3.0 × 10^-6--7.5 × 10^-4 mol·dm^-3 with the detection limit of 8.0 × 10^-7 molodm^-3. This modified electrode had some advantages over the modified film electrodes constructed by the conventional methods, such as renewable surface, good long-term stability, excellent catalytic activity and short response time to hydrazine.  相似文献   

9.
The application of p-aminophenol as a suitable mediator, as a sensitive and selective voltammetric sensor for the determination of hydrazine using square wave voltammetric method were described. The modified multiwall carbon nanotubes paste electrode exhibited a good electrocatalytic activity for the oxidation of hydrazine at pH = 7.0. The catalytic oxidation peak currents showed a linear dependence of the peaks current to the hydrazine concentrations in the range of 0.5–175 μmol/L with a correlation coefficient of 0.9975. The detection limit (S/N = 3) was estimated to be 0.3 μmol/L of hydrazine. The relative standard deviations for 0.7 and 5.0 μmol/L hydrazine were 1.7 and 1.1%, respectively. The modified electrode showed good sensitivity and selectivity. The diffusion coefficient (D = 9.5 × 10–4 cm2/s) and the kinetic parameters such as the electron transfer coefficient (α = 0.7) of hydrazine at the surface of the modified electrode were determined using electrochemical approaches. The electrode was successfully applied for the determination of hydrazine in real samples with satisfactory results.  相似文献   

10.
Capillary electrpphoresis (CE)/electrochemical detection (EC) for the simultane-ous determination of hydrazine and isoniazid has been developed.The electrochemical method uses a novel modified electrode dispersed with ultrafine platinum particles on the surface of a 30μm carbon fiber microelectrode.The unique characteristic of the Pt-particles modified carbon fiber microelectrode is its excellent stability.The current measurement for hydrazine is more sensitive than that of isoniazid.Selective determination of trace amount of free hydrazine in isoniazid and its formulation can be achieved at applied potential of 0.5V.  相似文献   

11.
《Electroanalysis》2017,29(2):587-594
A sensitive and selective hydrazine sensor was developed by β‐cyclodextrin modified palladium nanoparticles decorated reduced graphene oxide (PdNPs‐β‐CD/rGO) nanocomposite. The PdNPs‐β‐CD/rGO hybrid material was prepared by simple electrochemical method. The hydrophobic cavity of β‐CD ineracts with palladium nanoparticles by hydrophobic interaction and further it is uniformly assembled on the rGO surface through hydrogen bond formation, which is clearly confirmed by FT‐IR, FESEM and TEM. The high electrocatalytic activity of hydrazine oxidation was observed at −0.05 V (vs. Ag/AgCl) on PdNPs‐β‐CD/rGO modified electrode; due to the excellent stabilization, high catalytic activity and large surface area of the PdNPs‐β‐CD/rGO composite. The PdNPs‐β‐CD/rGO fabricated hydrazine sensor exhibited an excellent analytical performance, including high sensitivity (1.95 μA μM−1 cm−2), lower detection limit (28 nM) and a wide linear range (0.05 to 1600 μM). We also demonstrated that the PdNPs‐β‐CD/rGO nanocomposite modified electrode is a highly selective and sensitive sensor towards detection of hydrazine among the various interfering species. Hence, the proposed hydrazine sensor is able to determine hydrazine in different water samples.  相似文献   

12.
This article reports on the use of cobalt(II) phthalocyanine (CoPc)-modified carbon paste amperometric detector for monitoring hydrazine compounds following their microchip separation. The marked catalytic electrochemical properties of CoPc-modified electrode display enhanced sensitivity compared with unmodified carbon pastes at a relatively low detection potential (+0.5 V versus Ag/AgCl). Factors influencing the on-chip separation and detection processes have been optimized. Three hydrazines (hydrazine, 1,1 dimethylhydrazine, and phenylhydrazine) have been separated within 130 s at a separation voltage of 1 kV using a 10 mM phosphate run buffer (pH 6.5). The detection limits obtained from using the CoPc-modified carbon paste electrodes for hydrazine and phenylhydrazine are 0.5 and 0.7 μM, respectively, with linearity over the 20–200 μM range examined. Such miniaturization and speed advantages of microchip CE are coupled to the highly sensitivity and convenient preparation of CoPc-modified carbon paste electrode. The resulting microsystem should be attractive for field monitoring of toxic hydrazine compounds in environmental applications.  相似文献   

13.
构建了不同百分含量的氮掺杂的多壁碳纳米管化学修饰石墨电极,利用线性扫描伏安法及循环伏安法研究了双酚A(BPA)在修饰电极上的电化学行为。提出了一种灵敏、简便的直接检测双酚A的电化学分析方法。在pH6.98的PBS缓冲溶液中,在电位0.20 V富集后,该修饰电极在0.680 V出现一个灵敏的、峰形好的氧化峰。表明氮掺杂多壁碳纳米管薄膜对双酚A的氧化表现出一定的催化作用,能显著提高双酚A的氧化峰电流。在优化条件下,采用线性扫描伏安法对双酚A进行测定。双酚A的氧化峰电流与其浓度在2.5×10-7~1.0×10-4 mol/L之间有很好的线性关系(R为0.996),检出限为5.0×10-8mol/L。电极已初步用于实际样品中BPA的测定。  相似文献   

14.
A sensitive hydrazine sensor has been fabricated using copper oxide nanoparticles modified glassy carbon electrode (GCE) to form nano-copper oxide/GCE. The nano-copper oxide was electrodeposited on the surface of GCE in CuCl2 solution at −0.4 V and was characterized by Scanning electron microscopy and X-ray diffraction. The prepared modified electrode showed a good electrocatalytic activity toward oxidation of hydrazine. The electrochemical behavior of hydrazine on nano-copper oxide/GCE was explored. The oxidative current increased linearly with improving concentration of hydrazine on nano-copper oxide/GCE from 0.1 to 600 μM and detection limit for hydrazine was evaluated to be 0.03 μM at a signal-to-noise ratio of 3. The oxidation mechanism of hydrazine on the nano-copper oxide/GCE was also discussed. The fabricated sensor could be used to determine hydrazine in real water.  相似文献   

15.
Salimi A  Miranzadeh L  Hallaj R 《Talanta》2008,75(1):147-156
A simple procedure was developed to prepare a glassy carbon (GC) electrode modified with carbon nanotubes (CNTs) and catechol compounds. First, 25 microL of DMSO-CNTs solutions (0.4 mg/mL) was cast on the surface of GC electrode and dried in air to form a CNTs film. Then the GC/CNTs modified electrode immersed into a chlorogenic acid, catechine hydrate and caffeic acid solution (electroless deposition) for a short period of time (2-80s). The cyclic voltammogram of the modified electrode in aqueous solution shows a pair of well-defined, stable and nearly reversible redox couple (quinone/hydroquinone) with surface confined characteristics. The combination of unique electronic and electrocatalytic properties of CNTs and catechol compounds results in a remarkable synergistic augmentation on the response. The electrochemical reversibility and stability of modified electrode prepared with incorporation of catechol compound into CNTs film was evaluated and compared with usual methods for attachment of catechols to electrode surfaces. The transfer coefficient (alpha), heterogeneous electron transfer rate constants (k(s)) and surface concentrations (Gamma) for GC/CNTs/catechol compound modified electrodes were calculated through the cyclic voltammetry technique. The modified electrodes showed excellent catalytic activity, fast response time and high sensitivity toward oxidation of hydrazine in phosphate buffer solutions at pH range 4-8. The modified electrode retains its initial response for at least 2 months if stored in dry ambient condition. The properties of modified electrodes as an amperometric sensor for micromolar or lower concentration detection of hydrazine have been characterized.  相似文献   

16.
In this work, edged plane pyrolytic graphite electrode EPPGE was modified with functionalised single‐walled carbon nanotubes and Prussian blue nanoparticles (PB). The modified electrode was characterised by techniques such as TEM, FTIR, XPS, EDX and cyclic voltammetry. The EPPGE‐SWCNT‐PB platform exhibited enhanced electron transport and catalytic efficiency towards the oxidation of Diethylaminoethanethiol (DEAET) and hydrazine compared with the other electrodes studied. The EPPGE‐SWCNT‐PB showed good electrochemical stability in the analytical solution, showing limit of detection in the micromolar range and catalytic rate constant of 3.71×106 and 7.56×106 cm3 mol?1 s?1 for DEAET and hydrazine respectively. The adsorption properties of these analytes that impact on their detection at the SWCNT‐PB film modified electrode were evaluated and discussed.  相似文献   

17.
A novel method for the determination of cobalt(II) by stripping voltammetry is described. It involves an adsorptive accumulation of the cobalt(II)-2-aminocyclopentene-1-dithiocarboxylic acid complex on a hanging mercury drop electrode, followed by a stripping voltammetric measurement of the catalytic reduction current of the complex at –1.4 V at pH = 9 (vs. Ag/AgCl). The effects of various experimental parameters on the catalytic current were investigated. An accumulation time of 60 s results in a low experimental limit of detection of 0.1 ng/mL of Co(II), and 0.50 to 40.0 ng/mL of cobalt can be determined. The relative standard deviation at 0.50 ng/mL is 2.8%. Possible interferences from co-existing ions were also investigated. Received: 17 August 1998 / Revised: 16 November 1998 / Accepted: 20 November 1998  相似文献   

18.
Tanaka S  Yoshida H 《Talanta》1988,35(11):837-840
The adsorptive voltammetry of lipoic acid and lipoamide was investigated with a hanging mercury drop electrode. These compounds produced a catalytic hydrogen wave at - 1.35 V in ammonia buffer solution containing cobalt(II), and the peak current increased with adsorptive accumulation at the electrode. Thus adsorptive voltammetry with the catalytic hydrogen wave could provide a sensitive method for determining trace amounts of lipoic acid and lipoamide. The calibration graphs for both compounds were linear over the range 2-10nM with accumulation for 5 min at -0.6 V, and the detection limit was ca. 0.5nM.  相似文献   

19.
A novel method for the determination of cobalt(II) by stripping voltammetry is described. It involves an adsorptive accumulation of the cobalt(II)-2-aminocyclopentene-1-dithiocarboxylic acid complex on a hanging mercury drop electrode, followed by a stripping voltammetric measurement of the catalytic reduction current of the complex at –1.4 V at pH = 9 (vs. Ag/AgCl). The effects of various experimental parameters on the catalytic current were investigated. An accumulation time of 60 s results in a low experimental limit of detection of 0.1 ng/mL of Co(II), and 0.50 to 40.0 ng/mL of cobalt can be determined. The relative standard deviation at 0.50 ng/mL is 2.8%. Possible interferences from co-existing ions were also investigated. Received: 17 August 1998 / Revised: 16 November 1998 / Accepted: 20 November 1998  相似文献   

20.
Cyclic voltammetry was used to investigate the electrochemical behaviour of ascorbic acid at a carbon—epoxy composite electrode modified with the electron mediator cobalt phthalocyanine. The modified electrode reduced the overpotential necessary for the oxidation of the vitamin by approximately 150 mV to 0.21 V vs. The saturated calomel electrode; the process was dependent on the pH of the supporting electrolyte, but independent of ionic strength over the range studied. The relative standard deviation (r.s.d.) of the peak heights of the cyclic voltammograms was 0.81% for a 1 × 10?4 M ascorbic acid solution (n = 7). The optimum supporting electrolyte was found to be 0.05 M phosphate buffer (pH 5).Amperometry in stirred solutions was then done at an applied potential of +0.25 V. The limit of detection was 0.65 ng ml?1 and the calibration graph was linear in the range 175 ng ml?1?50 μg ml?1. The method was used to determine ascorbic acid concentrations in single- and multivitamin preparations; the recovery was 97.86% for the vitamin added to one preparation. The r.s.d. for the analyses in these samples was about 5%. For comparison, the vitamin was also determined in these tablets using LC with UV detection at 254 nm; the correlation coefficient for the levels determined was 0.9989 (p = 0.0007).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号