首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 671 毫秒
1.
A biosensor for glucose utilizing kinetics of glucose oxidase (EC 1.1.3.4.) was developed. The enzyme was immobilized on polyaniline by covalent bonding, using glutaraldehyde as a bifunctional agent. The system showed a linear response up to 2.2 mM of glucose with a response time of 2.5–4.0 min. In addition, the immobilized enzyme had a higher activity between pH 6.5 and 7.5. The system retained 50% of its activity after 30 d of daily use. The optical absorption spectra of the polyaniline/glucose oxidase electrode after glucose had been added to the buffer solution showed that the absorption band around 800 nm had changed considerably when glucose was allowed to react with the electrode. This optical variation makes polyaniline a very promising polymer for use as a support in optical sensor for clinical application.  相似文献   

2.
鱼鳔膜为基质的生物传感器测定葡萄糖的研究   总被引:1,自引:0,他引:1  
贾文娟  崔淼  张彦  双少敏 《分析化学》2011,(9):1423-1426
以鱼鳔膜为基质同定葡萄糖氧化酶,偶联氧电极,构建了葡萄糖生物传感器,通过测定溶解氧浓度的变化定量测定葡萄糖.考察了酶浓度、pH值、缓冲液浓度对传感器的影响,优化了实验条件:即酶浓度为1 mg,pH 7.0,缓冲液浓度为100 mmol/L.此传感器具有较宽的线性范围(0.016~1.2 mmol/L),较短的响应时间(...  相似文献   

3.
A novel amperometric glucose biosensor based on layer‐by‐layer (LbL) electrostatic adsorption of glucose oxidase (GOx) and dendrimer‐encapsulated Pt nanoparticles (Pt‐DENs) on multiwalled carbon nanotubes (CNTs) was described. Anionic GOx was immobilized on the negatively charged CNTs surface by alternatively assembling a cationic Pt‐DENs layer and an anionic GOx layer. Transmission electron microscopy images and ζ‐potentials proved the formation of layer‐by‐layer nanostructures on carboxyl‐functionalized CNTs. LbL technique provided a favorable microenvironment to keep the bioactivity of GOx and prevent enzyme molecule leakage. The excellent electrocatalytic activity of CNTs and Pt‐DENs toward H2O2 and special three‐dimensional structure of the enzyme electrode resulted in good characteristics such as a low detection limit of 2.5 μM, a wide linear range of 5 μM–0.65 mM, a short response time (within 5 s), and high sensitivity (30.64 μA mM?1 cm?2) and stability (80% remains after 30 days).  相似文献   

4.
Nanofibrous membranes have been produced by electrospinning to develop first generation glucose biosensors. The direct immobilization of glucose oxidase onto the polyamide nanofibrous surfaces by drop coating revealed a simple and efficient method for the development of sensitive, stable, and reproducible electrochemical biosensors. The biosensor showed a linear response over the range 1–9×10?3 glucose (R2=0.9997) with a sensitivity of 1.11 μA/mM and a limit of detection of 2.5×10?6 M (S/N=3). The uncertainty of repeatability was 2% (RSD%, n=30). After one month of storage, the signal decreased of 35%. The recovery of glucose, evaluated in real samples of honey, was 98% (RSD%=1%, n=3).  相似文献   

5.
铂纳米颗粒修饰直立碳纳米管电极的葡萄糖生物传感器   总被引:1,自引:0,他引:1  
基于Pt纳米颗粒修饰直立的碳纳米管电极制备了葡萄糖生物传感器.铂纳米颗粒是利用电位脉冲沉积法修饰到直立碳纳米管上的,可以增强电极对酶反应过程当中产生的过氧化氢的催化行为.用扫描电镜和透射电镜观察了直立碳纳米管在修饰Pt纳米颗粒前后的形态.该酶电极对葡萄糖的氧化表现出很好的响应,线性范围为1×10-5~7×10-3mol/L,响应时间小于5s,并且有很好的重现性.  相似文献   

6.
用蜘蛛丝素和聚乙烯醇的混合材料把葡萄糖氧化酶固定在氧电极表面,制成葡萄糖氧化酶电极。传感器对葡萄糖有灵敏的响应,平均响应时间为20s,电位变化值与葡萄糖浓度在3.0×10  相似文献   

7.
A novel glucose biosensor was developed based on the immobilization of glucose oxidase (GOx) on reduced graphene oxide incorporated with electrochemically deposited platinum and palladium nanoparticles (PtPdNPs). Reduced graphene oxide (RGO) was more hybridized by chemical and heat treatment. Bimetallic nanoparticles were deposited electrochemically on the RGO surface for potential application of the Pd? Pt alloy in biosensor preparation. The as‐prepared hybrid electrode exhibited high electrocatalytic activities toward H2O2, with a wide linear response range from 0.5 to 8 mM (R2=0.997) and high sensitivity of 814×10?6 A/mMcm2. Furthermore, glucose oxidase with active material was integrated by a simple casting method on the RGO/PdPtNPs surface. The as‐prepared biosensor showed good amperometric response to glucose in the linear range from 2 mM to 12 mM, with a sensitivity of 24×10?6 A/mMcm2, a low detection limit of 0.001 mM, and a short response time (5 s). Moreover, the effect of interference materials, reproducibility and the stability of the sensor were also investigated.  相似文献   

8.
《Analytical letters》2012,45(10):1817-1832
Abstract

Glucose was continuously determined by reaction in a packed-bed enzyme reactor containing glucose oxidase and catalase. Oxygen consumption was measured amperometrically with a polarographic Clark electrode. Glucose was sampled through a dialysis probe immersed in the solution to be measured. An extension of the normal range for the enzyme was achieved by modulating the flow rate through the dialysis probe and a linear response was obtained in the range of 1.0-60 mM glucose. The correlation between the glucose transfer and the membrane area of the dialysis probe was also studied. Six different membranes were used, all showing variations in the adhesion of yeast cells.  相似文献   

9.
姚慧  李楠  徐景忠  朱俊杰 《中国化学》2005,23(3):275-279
本文选用生物相容性好的壳聚糖作为基体材料,使其与戊二醛交联成网状结构包埋葡萄糖氧化酶制成电化学传感器。这种壳聚糖膜不仅可以减小葡萄糖氧化酶的流失,而且能为酶提供了适宜的微环境。用红外光谱、紫外光谱及透射电镜对膜的形态和性质进行了表征。实验结果表明该传感器具有很快的响应速度,很好的稳定性和重现性,能选择性地催化葡萄糖并测定其浓度。该传感器的制备方法简单,成本低,于冰箱中放置两周信号保持在90%以上,对葡萄糖测量的线性范围为1×10-5 - 3.4×10-3mol•L-1,当信噪比为3:1时检测限为5×10-6mol•L-1。  相似文献   

10.
《Electroanalysis》2006,18(15):1485-1491
A novel cheap and simple amperometric biosensor, based on the immobilization of glucose oxidase (GOD) into anionic clay; layered double hydroxides (LDHs) [Zn3‐Al‐Cl] is presented. GOD can be entrapped in the LDHs gel via electrostatic interaction. Amperometric detection of glucose with an unmediated sensor at 0.6 V (vs. SCE) results in a rapid response (5 s), a wide linear range of 0.001–12 mM, as well as good operational stability. The low detection limit was 0.1 μM at 3σ. The apparent Michaelis‐Menten constant (K is 4.4 mM. The general interferences that coexisted in blood serum do not affect glucose determination, except for uric acid. In addition, optimization of the biosensor construction and the effects of the applied potential on the amperometric response of the sensor were investigated and discussed herein.  相似文献   

11.
The Prussian blue/ionic liquid-polyaniline/multiwall carbon nanotubes (PB/IL-PANI/MWNTs) composite film was fabricated by using cyclic voltammetry. The ion liquid acting as a lubricating agent, could enhance the electron delocalization degree and reduce the struc-tural defects of the polyaniline. The surface morphology of the composite film revealed that the PB nanoparticles have smaller size than that in pure PB film. Due to the introduction of ion liquid, the PB/IL-PANI/MWNTs composite film showed wonderful synergistic effect which can remarkably enhance sensitivity, expand linear range and broaden acidic adapt-ability for hydrogen peroxide detection. The composite film demonstrated good stability in neutral solution contrast to pure PB film, with a linear range from 2.5 μmol/L to 0.5 mmol/Land a high sensitivity of 736.8 μA·(mmol/L)-1·cm-2 for H2O2 detection. Based on the com-posite film, an amperometric glucose biosensor was then fabricated by immobilizing glucose oxidase. Under the optimal conditions, the biosensor also exhibits excellent response to glucose with the linear range from 12.5 μmol/L to 1.75 mmol/L and a high sensitivity of 94.79 μA (mmol/L)-1·cm-2 for H2O2. The detection limit was estimated 1.1 μmol/L. The resulting biosensor was applied to detect the blood sugar in human serum samples without any pretreatment, and the results were comparatively in agreement with the clinical assay.  相似文献   

12.
《Electroanalysis》2006,18(15):1499-1504
An amperometric method for the determination of glucose using a screen printed carbon electrode is reported. The electrode material was bulk modified with rhodium dioxide and the enzyme glucose oxidase immobilized in a Nafion‐film on the electrode surface and investigated for its ability to serve as a detector of glucose in flow injection analysis. The sensor exhibited a linear increase of the amperometric signal with the concentration of glucose in the range of 1–250 mg L?1 with a detection limit (evaluated as 3σ) of 0.2 mg L?1 under optimized flow rate of 0.4 mL min?1 in 0.1 M phosphate buffer (pH 7.5) carrier. At the potential applied (?0.2 V vs. Ag/AgCl), interferences from redox species present in the sample matrix were negligible. The biosensor reported here retained its activity for more than 40 injections or 4 months of storage at 6 °C. The RSD was determined as 1.8% for a glucose concentration of 25 mg L?1 (n=5) with a typical response time of about 28 s.  相似文献   

13.
建立了多壁碳纳米管(MWNTs)负载铂二二氧化钌纳米颗粒的液相化学还原法.以Nafion为固定剂,将Pt-RuO2/MWNTs复合材料修饰于玻碳电极的表面,制备了一种无酶型葡萄糖传感器.实验表明:复合材料修饰的电极对葡萄糖响应电流明显,并且受抗坏血酸(AA)、多巴胺(DA)和尿酸(UA)的干扰小.本实验采用安培法测定葡萄糖,线性范围为2 0×10 3~1.0×10-2 mol/L(R~0.9965);灵敏度为119.26 μA cm-2(mmol/L)-1;检出限为1.25×10 -5 mol/L(信噪比为3);响应时间为4.8 s.PtRuO2/MWNTs修饰电极可作为性能良好的无酶型葡萄糖传感器.  相似文献   

14.
Glucose oxidase (GOD) was encapsulated in chitosan matrix and immobilized on a glassy carbon electrode, achieving direct electron transfer (DET) reaction between GOD and electrode without any nano‐material. On basis of such DET, a novel glucose biosensor was fabricated for direct bioelectrochemical sensing without any electron‐mediator. GOD incorporated in chitosan films gave a pair of stable, well‐defined, and quasireversible cyclic voltammetric peaks at about ?0.284 (Epa) and ?0.338 V (Epc) vs. Ag/AgCl electrode in phosphate buffers. And the peak is located at the potentials characteristic of FAD redox couples of the proteins. The electrochemical parameters, such as midpoint potential (E1/2) and apparent heterogeneous electron‐transfer rate constants (ks) were estimated to ?0.311 V and 1.79 s?1 by voltammetry, respectively. Experimental results indicate that the encapsulated GOD retains its catalytic activity for the oxidation of glucose. Such a GOD encapsulated chitosan based biosensor revealed a relatively rapid response time of less than 2 min, and a sufficient linear detection range for glucose concentration, from 0.60 to 2.80 mmol L?1 with a detection limit of 0.10 mmol L?1 and electrode sensitivity of 0.233 μA mmol?1. The relative standard deviation (RSD) is under 3.2% (n=7) for the determination of practical serum samples. The biologic compounds probably existed in the sample, such as ascorbic acid, uric acid, dopamine, and epinephrine, do not affect the determination of glucose. The proposed method is satisfactory to the determination of human serum samples compared with the routine hexokinase method. Both the unique electrical property and biocompatibility of chitosan enable the construction of a good bio‐sensing platform for achieved DET of GOD and developed the third‐generation glucose biosensors.  相似文献   

15.
《Analytical letters》2012,45(7):1173-1183
Abstract

An amperometric glucose biosensor based on the detection of the reduction of oxygen has been developed by combining an aminated glassy carbon electrode with a polystyrene (PS) membrane containing glucose oxidase (GOD) micelles. The structure of GOD micelles contained in PS membrane was observed by scanning electron microscope. The micelle has a roughly spherical shape, and the enzyme colony is contained inside the micelle. This glucose sensor exhibited good sensitivity with short response time (within 2 min). A good linear relationship was observed in the concentration range of 0.2 mM to 2.6 mM when the applied potential was ? 0.45 V vs. Ag/AgCl.  相似文献   

16.
Glucose oxidase(GOD) was encapsulated in the Graphene/Nafion film modified glassy carbon electrode(GCE) and used as an ECL sensor for glucose. The GOD retains its bioactivity after being immobilized into the composite film. The sensor gives a linear response for glucose in the range of 2.0×10?6–1.0×10?4 mol/L with a detection limit of 1.0×10?6 mol/L. The sensor showed good stability, the RSD for continuous scanning for 5.0×10?5 mol/L glucose was 4.21 % (n=5). After being stored in 0.05 mol/L pH 7.4 PBS in 4 °C for two weeks, the modified electrode maintains 80 % of its initial activity. The glucose sensor provides new opportunity for clinical diagnosis applications.  相似文献   

17.
用循环伏安法在石墨电极上制得纳米纤维聚苯胺, 并在其上固定葡萄糖氧化酶(GOD)和辣根过氧化物酶(HRP)制备葡萄糖双酶传感器. 用交流阻抗、SEM等技术对其进行表征; 考察了各种因素对双酶电极响应电流的影响以及双酶电极的稳定性. 该传感器对葡萄糖响应电流的测定在0.05 V(vs SCE)下进行, 有效避免了电活性物质的影响, 线性响应范围为0.05-2.0 mmol·L-1.  相似文献   

18.
A new concept is described for monitoring a biomolecule with a sensor having an enzyme entrapped in a conducting polymer. This is based on the sensitivity of the electroactive polymer itself to changes of pH in solution. The concept has been investigated for a glucose sensor with glucose oxidase (GOD) immobilized in a polypyrrole (PPy) layer on an inert platinum electrode. Measurements with a Pt/PPy/GOD electrode for glucose concentrations in the physiological range gave a linear correlation with logarithm of concentration over one decade with a satisfactory dynamic response. There was practically no change of slope or range of linear response to glucose after several days of use; this was in contrast to the amperometric response of the detector when there was about a 50% loss of sensitivity.  相似文献   

19.
An efficient amperometric biosensor based on well‐crystallized leaf‐like CuO nanoparticles for detecting glucose has been proposed. The leaf‐like CuO nanoparticles, synthesized by a simple one‐step hydrothermal method, were characterized by X‐ray diffraction (XRD), scanning electron microscope (SEM) and transmission electron microscopy (TEM) for the morphology study. Under the optimal condition, the electrochemical behaviour of the leaf‐like CuO nanoparticles modified electrode for detection of glucose exhibited high sensitivity of 246 µA/mM/cm2, short response time (within 5 s), linear dynamic range from 1.0 to 170 µM (R2=0.9995), and low limit of detection (LOD) (S/N=3) of 0.91 µM. The high sensitivity, good reproducibility, stability, and fast amperometric sensing towards oxidation of glucose, make this biosensor promising for future application.  相似文献   

20.
《Electroanalysis》2003,15(11):975-981
The redox chemistry of several substituted benzoquinones was investigated by cyclic voltammetry at a glassy carbon electrode and candidates for inclusion in a mediated biosensor for use in flow analysis were selected on the basis of oxidation potential, electrochemical reversibility and solubility. Glucose sensors constructed by sequential deposition onto a carbon pellet of 2,6‐dimethyl‐1,4‐benzoquinone, 2,3,5,6‐tetramethyl‐1,4‐benzoquinone or phenyl‐1,4‐benzoquinone mediator solution, followed by glucose oxidase in polyvinylalcohol‐Nafion solution, were tested for response to glucose using flow injection analysis. Sensors prepared from 2,6‐dimethyl‐1,4‐benzoquinone gave highest sensitivity, with a linear range of response to glucose of 2.5–40 mM. The use of an enzyme‐free comparative electrode to eliminate the response from interferents was investigated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号