1.
A rapid and sensitive analytical method was developed for the residue analysis of ten quinolones (enoxacin (ENO), ofloxacin (OFL), norfloxacin (NOR), ciprofloxacin (CIP), danofloxacin (DAN), enrofloxacin (ENR), sarafloxacin (SAR), oxolinic acid (OXO), nalidixic acid (NAL), and flumequine (FLU)) in cow's milk. The analytes were extracted from milk by a deproteinization step followed by a simple SPE cleanup procedure using LiChrolut RP-18 Merck cartridges. Recoveries varied between 75 and 92%. HPLC separation was performed at 25 degrees C using an ODS-3 PerfectSil Target (250 x 4 mm(2)) 5 microm analytical column (MZ-Analysentechnik, Germany). The mobile phase consisted of a mixture of TFA 0.1%-CH(3)CN-CH(3)OH, delivered by a gradient program at the flow rate of 1.2 mL/min. Elution of the ten analytes and the internal standard (caffeine, 7.5 ng/microL) was completed within 27 min. Column effluent was monitored using a photodiode array detector, set at 275 and 255 nm. The developed method was validated according to the criteria of Commission Decision 2002/657/EC. The LODs of the specific method of quinolones' determination in milk varied between 1.5 and 6.8 ng/microL.  相似文献   

2.
Qiu H  Yin XB  Yan J  Zhao X  Yang X  Wang E 《Electrophoresis》2005,26(3):687-693
A simultaneous electrochemical (EC) and electrochemiluminescence (ECL) detection scheme was introduced to both microchip and conventional capillary electrophoresis (CE). In this dual detection scheme, tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)3(2+)) was used as an ECL reagent as well as a catalyst (in the formation of Ru(bpy)3(3+)) for the EC detection. In the Ru(bpy)3(2+)-ECL process, Ru(bpy)3(3+) was generated and then reacted with analytes resulting in an ECL emission and a great current enhancement in EC detection due to the catalysis of Ru(bpy)3(3+). The current response and ECL signals were monitored simultaneously. In the experiments, dopamine and three kinds of pharmaceuticals, anisodamine, ofloxacin, and lidocaine, were selected to validate this dual detection strategy. Typically, for the EC detection of dopamine with the presence of Ru(bpy)3(2+), a approximately 5 times higher signal-to-noise ratio (S/N) can be achieved than that without Ru(bpy)3(2+), during the simultaneous EC and ECL detection of a mixture of dopamine and lidocaine using CE separation. The results indicated that this dual EC and ECL detection strategy could provide a simple and convenient detection method for analysis of more kinds of analytes in CE separation than the single EC or ECL detection alone, and more information of analytes could be achieved in analytical applications simultaneously.  相似文献   

3.
The present paper describes the development and validation of a new reversed-phase liquid chromatography–electrospray ionization tandem mass spectrometric method (RP-HPLC–ESI-MS/MS) for simultaneous determination of pyridine, 2-picoline, 4-picoline and quinoline from mainstream cigarette smoke. Liquid–liquid extraction followed by solid-phase extraction was applied to extract the target analytes from cigarette smoke. Baseline chromatographic separation was achieved by utilizing a Zorbax SB-Aq (4.6 × 150 mm, 5 μm) column in gradient chromatographic conditions with acetonitrile and ammonium acetate buffer as mobile phases. Popular commercially available Indian brand filtered and non-filtered cigarettes were analyzed using the same method. The identification of each chemical was established by chromatographic retention times, analyte specific fragmentation patterns and relative peak area ratios of two product/precursor ion pairs. The limit of detection of this method ranged from 1.74 to 14.32 ng/cig using an injection volume of 20 μl. The reproducibility of this method is excellent and better standard deviations were obtained compared to literature reported values for these chemicals. RSD value is less than 9% for all analytes.  相似文献   

4.
A rapid, accurate and robust method for the determination of catechin (C), epicatechin (EC), gallocatechin (GC), epigallocatechin (EGC), catechin gallate (Cg), epicatechin gallate (ECg), gallocatechin gallate (GCg) and epigallocatechin gallate (EGCg) concentrations in human plasma has been developed. The method utilizes protein precipitation following enzyme hydrolysis, with chromatographic separation and detection using reversed‐phase liquid chromatography–tandem mass spectrometry (LC–MS/MS). Traditional issues such as lengthy chromatographic runtimes, sample and extract stability, and lack of suitable internal standards have been addressed. The method has been evaluated using a comprehensive validation procedure, confirming linearity over appropriate concentration ranges, and inter/intra‐batch precision and accuracies within suitable thresholds (precisions within 13.8% and accuracies within 12.4%). Recoveries of analytes were found to be consistent between different matrix samples, compensated for using suitable internal markers and within the performance of the instrumentation used. Similarly, chromatographic interferences have been corrected using the internal markers selected. Stability of all analytes in matrix is demonstrated over 32 days and throughout extraction conditions. This method is suitable for high‐throughput sample analysis studies.  相似文献   

5.
A fast, sensitive and reliable ultra fast liquid chromatography‐tandem mass spectrometry (UFLC‐MS/MS) method has been developed and validated for simultaneous quantitation of polygalaxanthone III (POL), ginsenoside Rb1 (GRb1), ginsenoside Rd (GRd), ginsenoside Re (GRe), ginsenoside Rg1 (GRg1) and tumulosic acid (TUM) in rat plasma after oral administration of Kai‐Xin‐San, which plays an important role for the treatment of Alzheimer's disease (AD). The plasma samples were extracted by liquid–liquid extraction using ethyl acetate–isopropanol (1:1, v/v) with salidrdoside as internal standard (IS). Good chromatographic separation was achieved using gradient elution with the mobile phase consisting of methanol and 0.01% acetic acid in water. The tandem mass spectrometric detection was performed in multiple reaction monitoring mode on 4000Q UFLC‐MS/MS system with turbo ion spray source in a negative and positive switching ionization mode. The lower limits of quantification were 0.2–1.5 ng/ml for all the analytes. Both intra‐day and inter‐day precision and accuracy of analytes were well within acceptance criteria (±15%). The mean absolute extraction recoveries of analytes and IS from rat plasma were all more than 60.0%. The validated method has been successfully applied to comparing pharmacokinetic profiles of analytes in normal and AD rat plasma. The results indicated that no significant differences in pharmacokinetic parameters of GRe, GRg1 and TUM were observed between the two groups, while the absorption of POL and GRd in AD group were significantly higher than those in normal group; moreover, the GRb1 absorbed more rapidly in model group. The different characters of pharmacokinetics might be caused by pharmacological effects of the analytes. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
In this paper, a methodology to evaluate the probability of false non-compliance and false compliance for screening methods, which give first or second-order multivariate signals is proposed. For this task 120 samples of 6 different kinds of milk have been measured by excitation-emission fluorescence. The samples have been spiked with different amounts of three sulfonamides (sulfadiazine, sulfamerazine and sulfamethazine). These substances have been classified in group B1 (veterinary medicines and contaminants) of annex I of Directive 96/23/EC. The European Union (Commission Regulation EC no. 281/96) has set the maximum residue level (MRL) of total sulfonamides at 100 μg kg−1 in muscle, liver, kidney and milk.The work shows that excitation-emission fluorescence together with the partial least squares class modeling (PLS-CM) procedure may be a suitable and cheap screening method for the total amount of sulfonamides in milk. Three models, PLS-CM, have been built, for the emission and excitation spectra (first-order signals) and for the excitation-emission matrices (second-order signals). In all the cases it reaches probabilities of false compliance below 5% as required by Decision 2002/657/EC.With the same flourescence signals, the total quantity of sulfonamide was calibrated using 2-PLS, 3-PLS and PARAFAC regressions. Using this quantitative approach, the capability of detection, CCβ, around the MRL has been estimated between 114.3 and 115.1 μg kg−1 for a probability of false non-compliance and false compliance equal to 5%.  相似文献   

7.
This paper describes a new method for the effective extraction, clean-up and chromatographic analysis of residues of four fluoroquinolones (ciprofloxacin, enrofloxacin, danofloxacin and sarafloxacin) in powdered infant formulae and follow-on preparations. Samples were reconstituted following the manufacturer's recommendations and treated with trichloroacetic acid in methanol 10% (w/v) for deproteinization. Two solid-phase extraction cartridges have been evaluated for sample clean-up and preconcentration, Strata Screen A and Strata X and the later provided the best recoveries for all the analytes tested. Chromatographic analysis has been carried out using a polar endcapped column (AQUA C(18)) and fluorescence detection, with lomefloxacin (LOME) as internal standard. Method validation has been performed according to European Commission Decision 2002/657/EC criteria, in terms of linearity, recovery, precision, specificity, decision limit (CC(alpha)) and detection capability (CC(beta)). Typical recoveries ranged between 70 and 110% at levels below and above the maximum residue limits of the target analytes in bovine milk, with an excellent intralab reproducibility (RSDs<7%). Matrix effects did not significantly affect method accuracy, as evidenced by analyzing different brands of milk. The method has been successfully applied to the analysis of 100 samples of infant and follow-on formulae of the Spanish and Latin American market, using LC-MS/MS as confirmatory technique.  相似文献   

8.
A method based on ultra‐high performance liquid chromatography was developed and validated to detect six thyreostatic compounds: tapazole, thiouracil, methylthiouracil, dimethylthiouracil, propylthiouracil, and phenylthiouracil in faeces of bovine. Thyreostats were extracted from the matrix with a mixture of methanol and buffer (pH = 8). Next step was derivatization of analytes with 3‐iodobenzylbromide. The liquid chromatographic separation of derivatives was obtained on a SB‐C18 column (50 × 2.1 mm; 1.8 μm, Agilent) with gradient elution using a mobile phase consisting of acetonitrile/0.1% acetic acid within 7.5 min. The analysis was performed on a Shimadzu NEXERA X2 ultra‐high performance liquid chromatograph with triple quadrupole MS 8050 instrument operating in positive electrospray ionization mode. Depending on the target compound, two or three diagnostic signals (selected reaction monitoring transitions) were monitored. The procedure was validated according to the Commission Decision 2002/657/EC. Recovery and repeatability met the performance criteria specified by this document for banned compounds. The recovery ranged from 97.5 to 110.5%, and repeatability did not exceed 14.1%. Decision limits and detection capabilities were below 10 μg/kg. The highest decision limits and detection capabilities concentrations were observed for phenylthiouracil of 3.48 and 6.96 μg/kg, respectively.  相似文献   

9.
A simple, reliable and rapid ultra‐performance liquid chromatography–tandem mass spectrometry method was developed and validated for the simultaneous quantification of four secoiridoid (gentiopicroside, swertiamarin, sweroside) and iridoid glycosides (loganic acid), the bio‐active ingredients in rat plasma. After liquid–liquid extraction, chromatographic separation was accomplished on a Shim‐pack XR‐ODS column with a mobile phase consisting of methanol and 0.1% formic acid in water. A triple quadrupole tandem mass spectrometry equipped with an electrospray ionization source was used as detector operating both in positive and negative ionization mode and operated by multiple‐reaction monitoring scanning. The lower limits of quantitation were 0.25–30 ng/mL for all the analytes. Both intra‐day and inter‐day precision and accuracy of analytes were well within acceptance criteria (±15%). The mean extraction recoveries of analytes and internal standard (amygdalin) from rat plasma were all >71.4%. The validated method was successfully applied to a comparative pharmacokinetic study of four analytes in rat plasma between normal and arthritic rats after oral administration of Huo Luo Xiao Ling Dan and Gentiana macrophylla extract, respectively. Results showed significant differences in pharmacokinetic properties of the analytes among the different groups. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
In this paper, the past, present, and (possible) future of the European analytical criteria for residues are described. The elaboration of the revision of Commission Decision 9312561EC was a long process starting in 1996 and ending with the formation of a European Commission (EC) working group in 1998. This working group took account of developments in scientific and technical knowledge at that time and produced a draft version of the revision within 6 months. The revision, finally published in 2002 (2002/657/EC), includes new ideas on the identification of analytes and the criteria for performance assessment as well as validation procedures. Currently (2009), the evolution in analytical equipment and progress in scientific research, accompanied by recent European regulatory changes, demands an update or revision of the 2002/657/EC.  相似文献   

11.
The confirmatory LC-MS/MS method for the determination of residues for twelve coccidiostats including ionophore antibiotics (lasalocid, maduramycin, monensin, narasin, salinomycin, semduramycin) and chemical coccidiostats (clazuril, decoquinate, diclazuril, halofuginone, nicarbazin and robenidine) in poultry liver has been developed. The sample preparation was based on extraction with acetonitrile, defatting with Alumina columns and clean-up on Oasis HLB spe. The separation of analytes was performed on PhenylHexyl column with a gradient of acetonitrile, methanol and the ammonium formate pH 4.0. For all analytes, at least 2 diagnostic fragmentation ions were monitored. The validation, performed according to the CD 2002/657/EC, proved the suitability of the method for the confirmatory analysis of the coccidiostats. For lasalocid, however, low reproducibility was observed and the proper quantification could not be performed with this method.  相似文献   

12.
Neurotransmitters and their metabolites in central nervous system were known to play a significant role in sedation and hypnosis. A rapid and sensitive UFLC‐MS/MS method for simultaneous determination of serotonin, 5‐hydroxyindole acetic acid (5‐HIAA), tryptophan (Try), dopamine (DA), norepinephrine (NE), γ‐aminobutyric acid (GABA), glutamic acid (Glu) and acetylcholine (Ach) in rat brain without derivatization, ion‐pairing reagent or pre‐concentration was developed. Analytes and IS were separated on a Inertsil ODS‐EP column (150 mm × 4.6 mm, 5 µm particles) and analyzed in a single chromatographic run in less than 9.0 min, using gradient elution with the mobile phase consisting of methanol and 0.01% acetic acid in water at a flow rate of 1.2 ml min?1. The detection of the analytes was performed on 4000Q UFLC‐MS/MS system with turbo ion spray source in positive ion and multiple reaction monitoring mode. The developed method provided excellent linear calibration curves for the assay of analytes (R2 ≥ 0.9915). Limits of quantification were in the range of 1.0 ng ml?1 to 1.0 µg ml?1 for the analytes in rat brain. Intra‐ and inter‐day precision and accuracy of analytes were well within acceptance criteria (15%). Mean extraction recoveries of analytes and IS from rat brain were all more than 80.0%. Furthermore, the validated method was successfully applied to comparing profiles of analytes in normal and insomnic rat brains. Results indicated that there were statistically significant differences for serotonin, 5‐HIAA, DA, NE, Glu and Ach, but no significant difference for Try and GABA between two groups. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
Increasing the interlaboratory reproducibility of gas chromatographic retention indices requires avoiding measurements distorted by overloading effects. Several criteria of evaluating the limits of the mass overloading of gas chromatographic systems are compared and reconsidered. The criteria mostly appropriate for practical purposes are based on (i) the dependences of factors of peak broadening (ratio of peak height and its width) vs. amount of analyte injected into the chromatographic column and (ii) the dependence of parameters characterizing the peak distortion (asymmetry factor) vs. the amount of analyte. Both these criteria provide mutually comparable evaluations of the overloading limits for analytes of different polarity. At the same time, the dependence of retention indices vs. amounts of analyte injected in the chromatographic column cannot be recommended for overloading control, because the parameters of the corresponding linear regressions indicate temperature dependence. The interpretation of certain gas chromatographic anomalies requires the correct evaluation of overloading limits. For example, the unusual temperature dependence of retention indices of polar analytes on non‐polar stationary phases and the dependence of retention indices on ratio of amounts of target analytes and reference compounds.  相似文献   

14.
李跑  蔡文生  邵学广 《色谱》2017,35(1):8-13
化学计量学算法为重叠气相色谱-质谱(GC-MS)信号的解析提供了有效手段,但其在计算过程中一般需要将数据进行分段处理,然后只对信号的某些区间进行解析,难以实现真正意义上的高通量分析。该文结合移动窗口目标转换因子分析(MWTTFA)和非负免疫算法(NNIA),建立了一种高通量解析方法。首先,根据所有可能存在的目标组分的标准质谱信息,利用MWTTFA检验复杂信号中存在的组分,并确定目标组分的质谱信息和洗脱时间区域。以得到的质谱信息作为后续计算的输入值,利用NNIA解析得到相应的色谱信息。采用快速升温程序对17种和42种农药混合标准样品的GC-MS信号进行分析,利用所建立的方法可在10 min内得到全部组分的色谱和质谱信息。  相似文献   

15.
A sensitive, selective, specific and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric assay method was developed and validated for the simultaneous quantitation of alpha-,beta-arteether (alpha-,beta-AE) and its metabolite alpha-dihydroartemisinin (DHA) in monkey plasma using the propyl ether analogue of beta-arteether (PE) as an internal standard. The method involves a simple two-step liquid-liquid extraction with hexane. The analytes were chromatographed on a C(18) reversed-phase chromatographic column by isocratic elution with methanol-ammonium acetate buffer (pH 4) (92 : 8, v/v) and analysed by mass spectrometry in the multiple reaction monitoring mode. The chromatographic run time was 7 min and the weighted (1/x(2)) calibration curves were linear over the range 0.78-200 ng ml(-1). The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in monkey plasma were 0.39 and 0.78 ng ml(-1) respectively for all the analytes. The intra- and inter-batch precision and accuracy were found to be well within acceptable limits (<15%). All three analytes were stable even after three freeze-thaw cycles (deviation < 15%). The average absolute recoveries of alpha-,beta-AE, DHA and PE, used as an internal standard, from spiked plasma samples were 85.85 +/- 6.56, 70.10 +/- 7.06, 54.37 +/- 3.39 and 93.90 +/- 6.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of alpha-,beta-AE and DHA in rhesus monkeys.  相似文献   

16.
This paper describes a method for extraction of tapazol, thiouracil, methylthiouracil, propylthiouracil and mercaptobenzimidazol (MBI) from thyroid tissue. The solid-phase extraction procedure is optimized to obtain the maximum results for the main thyreostats including MBI. Different combinations of sample application, column conditioning and wash steps were tested. The analytes were extracted from the matrix with methanol. After solid-phase extraction they were derivatised with 7-chloro-4-nitrobenzo-2-furazan. Determination is carried out using liquid chromatography-electrospray mass spectrometry. The identification of the analytes was performed according to the final revision of the EU criteria (93/256/EC decision). The detection capability was 20 microg kg(-1) for all mentioned thyreostats.  相似文献   

17.
A new liquid chromatography/mass spectrometry interface, the laser spray, has been developed. Explosive vaporization and mist formation occur when an aqueous solution effusing out from the tip of the stainless-steel capillary is irradiated from the opposite side of the capillary by a 10.6 microm infrared laser. Weak ion signals could be detected when the plume was sampled through the ion sampling orifice. When a high voltage (3-4 kV) was applied to the stainless-steel capillary, strong ion signals appeared. The ion abundances were found to be orders of magnitude greater than those obtained by conventional electrospray ionization in the case of aqueous solutions. The present method is regarded as an electric-field assisted form of matrix-assisted laser desorption/ionization in which the liquid chromatographic solvent (water, etc.) acts as a liquid matrix. Laser spray ionization is expected to become a versatile method for biological mass spectrometry because this method is compatible with the natural solvent, water.  相似文献   

18.
A confirmatory multi-residue method has been developed to allow for the detection, confirmation and quantification of eleven coccidiostats in animal feed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method can be used to determine halofuginone, robenidine, nicarbazin, diclazuril, decoquinate, semduramicin, lasalocid, monensin, salinomycin, narasin, maduramicin at levels relating to unavoidable carry over as stated in Regulation 2009/8/EC. Feed samples are extracted with water and acetonitrile with the addition of anhydrous magnesium sulphate and sodium chloride. The extract then undergoes a freezing out step before being diluted and injected onto the LC-MS/MS system. The LC-MS/MS system is run in MRM mode with both positive and negative electrospray ionisation and can confirm all eleven analytes in a run time of 19 min. The sensitivity of the method allows quantification and confirmation for all coccidiostats at a 0.5% carry over level. The method was validated over three days in accordance with of European legislation; Commission Decision 2002/657/EC. Validation criteria of accuracy, precision, decision limit (CCα), and detection capability (CCβ) along with measurement uncertainty are calculated for all analytes. The method was then successfully used to analyse a number of feed samples that contained various coccidiostat substances.  相似文献   

19.
The H-Sensor reported herein is a micro-fluidic device compatible with flow injection analysis (FIA) and high performance liquid chromatography (HPLC). The device detects analytes at two separate off-chip absorbance flow cells, providing two simultaneous absorbance measurements. The ratio of these two absorbance signals contains analyte diffusion coefficient information. A theoretical model for the sensing mechanism is presented. The model relates the signal Ratio to analyte diffusion coefficient. The model is qualitatively evaluated by comparing theoretical and experimental signal Ratio values. Experimental signal Ratios were collected via FIA for a variety of analytes, including sodium azide, benzoic acid, amino acids, peptides, and proteins. Measuring absorbance at multiple wavelengths provides higher order data allowing the analyte signals from mixtures to be deconvolved via classical least squares (CLS). As a result of the H-Sensor providing two simultaneous signals as a function of time for each sample injection, two simulated second-order HPLC chromatograms were generated using experimental H-Sensor data. The chemometric deconvolution method referred to as the generalized rank annihilation method (GRAM) was used to demonstrate chromatographic and spectroscopic deconvolution. GRAM also provides the signal Ratio value, therefore simultaneously obtaining the analyte diffusion coefficient information during deconvolution. The two chromatograms successfully serve as the standard and unknown for the GRAM deconvolution. GRAM was evaluated on chromatograms at various chromatographic resolutions. GRAM was found to function to a chromatographic resolution at and above 0.25 with a percent quantitative error of less then 10%.  相似文献   

20.
Confirmation of suspected residues has been a long time domain of tandem triple quadrupole mass spectrometry (QqQ). The currently most widely used confirmation strategy relies on the use of two selected reaction monitoring signals (SRM). The details of this confirmation procedure are described in detail in the Commission Decision 93/256/EC (CD). On the other hand, high resolution mass spectrometry (HRMS) is nowadays increasingly used for trace analysis. Yet its utility for confirmatory purposes has not been well explored and utilized, since established confirmation strategies like the CD do not yet include rules for modern HRMS technologies.  相似文献   