首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
李健  王翼飞  周显青  施致雄 《分析化学》2016,(11):1742-1747
采用索氏提取、凝胶渗透色谱和固相萃取技术作为前处理方法,建立乳制品中6种新型溴系阻燃剂、8种多溴联苯醚、四溴双酚A和α、β、γ-六溴环十二烷异构体共18种溴系阻燃剂的同时提取与净化方法,并结合气相色谱-负化学源质谱法(GC-NCI/MS)和高效液相色谱-电喷雾电离-串联质谱法(HPLC-ESI-MS/MS)进行检测。奶样经冷冻干燥后以正己烷-丙酮(1:1, V/V)索氏提取,采用凝胶渗透色谱结合酸化硅胶柱净化,随后以LC-Si固相萃取柱分离气相和液相待测物。以GC-NCI/MS测定6种新型溴系阻燃剂和8种多溴联苯醚,以HPLC-MS/MS检测四溴双酚A和六溴环十二烷异构体,内标法定量。结果表明,以空白牛奶样品为加标基质,多数待测物平均回收率为80.1%~114.7%,方法具有良好的精密度(多数待测物相对标准偏差( RSD)在0.87%~14.9%)和灵敏度(检出限在0.2~119.2 pg/g之间),可满足乳制品中多种溴系阻燃剂同时提取、净化和检测需求。  相似文献   

2.
Xiao Z  Feng J  Shi Z  Li J  Zhao Y  Wu Y 《色谱》2011,29(12):1165-1172
建立了固相萃取同时提取、净化血清中四溴双酚A(TBBPA)、α, β, γ-六溴环十二烷(HBCD)和8种多溴联苯醚(PBDEs)同系物的样本前处理方法,并结合色谱-质谱分离分析技术检测人血清样本中该类化合物的含量。试样在加入各自的同位素内标物后以甲基叔丁基醚/正己烷(1:1, v/v)混合溶剂进行萃取,再经浓硫酸去除脂肪后,以LC-Si固相萃取柱分离HBCD/TBBPA和PBDEs。采用分步检测的方式,在50 mm长BEH C18反相色谱柱上以超高效液相色谱-串联质谱(UPLC-MS/MS)的多反应监测模式(MRM)检测HBCD和TBBPA,在15 m长的毛细管柱上以气相色谱-负化学源质谱(GC-NCI/MS)的选择离子监测模式(SIM)检测PBDEs。以胎牛血清为空白基质,当HBCD、TBBPA和BDE-209的加标水平为0.5 ng/g和5 ng/g、三溴至七溴联苯醚的加标水平为0.05 ng/g和0.5 ng/g时,它们的平均加标回收率为80.3%~108.8%,相对标准偏差为1.02%~11.42%(n=5);以信噪比(S/N)为3计算,方法的检出限(LOD)为1.81~42.16 pg/g。采用该方法对实际样品进行测定,结果表明,本方法快速、准确、灵敏度高,能够满足血清中HBCD、TBBPA和PBDEs残留的同时提取及测定的要求。  相似文献   

3.
An effective multi‐residue pretreatment technique, solid‐phase extraction (SPE) combined with dispersive liquid–liquid microextraction (DLLME), was proposed for the trace analysis of 14 polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) in milk samples using gas chromatography–mass spectrometry (GC‐MS). Interesting analytes in milk samples were extracted with hexane after protein precipitation. The hexane extracts were loaded on an LC‐Florisil column to isolate analytes from the milk matrix. The elutes were dried and dissolved in acetone, which was used as the disperser solvent in subsequent DLLME procedures. The effects of several important parameters on the extraction efficiency were evaluated. Under the optimized conditions, a linear relationship was obtained in the range of 0.02–10.00 μg/L (PCBs) and 0.5–100.00 μg/L (PBDEs). The LOD (S/N=3) and relative standard deviations (RSDs, n=5) for all analytes were 0.01–0.4 μg/L and 0.6–8.5%, respectively. The recoveries of the standards added to raw bovine milk samples were 74.0–131.8%, and the repeatabilities of the analysis results were 1.12–17.41%. This method has been successfully applied to estimating PCBs and PBDEs in milk samples.  相似文献   

4.
This study presents a time‐ and solvent‐saving method, pressurized liquid extraction (PLE), to extract polybrominated diphenyl ethers (PBDEs) in sediment samples. The effects of various operating parameters (i.e., extraction solution, temperature, pressure, static/dynamic extraction times) for the quantitative extraction of PBDEs by home‐made PLE were systematically investigated and optimized. The analytes were then identified and quantitated by gas chromatography‐mass spectrometry (GC‐MS) in selected ion monitoring (SIM) mode. The 16 PBDE congeners (from tri‐ to deca‐BDE) can be completely extracted by dichloromethane: n‐hexane (3/2, v/v) at 100 °C and 100 atm combined with 15 min static and then 15 min dynamic extraction steps. Recovery of PBDEs in spiked sediment samples ranged from 52 to 104% with 2‐16% RSD, except for BDE‐206. Limits of quantitation (LOQ) were established between 4 and 400 pg/g (dry weight) in 10 g of sediment sample. The extraction efficiency of the PLE was also compared with the traditional Soxhlet extraction method. The total contents of PBDEs ranged from 8.0 to 37.9 ng/g (dry weight) in various river and coastal sediment samples in Taiwan. Deca‐BDE (BDE‐209) was the major PBDE detected in these sediment samples.  相似文献   

5.
The concentrations of hexabromocyclododecanes (HBCD) in Sargassum fusiforme, the common Chinese edible seaweed, were investigated by LC‐MS/MS. For the recovery of HBCD, the efficiency levels of ultrasonic‐assisted extraction, microwave‐assisted extraction, Soxhlet extraction and pressurised liquid extraction were compared under different conditions. Pressurised liquid extraction and ultrasonic‐assisted extraction resulted in complete extraction of HBCD (92.7–102.5% recovery). Microwave‐assisted extraction and Soxhlet extraction, on the other hand, offered relatively low extraction recoveries (82.1–90.6%). The instrumental LODs on columns in this study were 1.0, 0.3 and 0.7 ng/g for α‐HBCD, β‐HBCD and γ‐HBCD, respectively. Because of its accuracy, this straightforward method is particularly suitable for routine HBCD analysis.  相似文献   

6.
A rapid and sensitive liquid chromatography–tandem mass spectrometric (LC‐MS/MS) assay method has been developed and fully validated for simultaneous quantification of donepezil and its active metabolite, 6‐o‐desmethyl donepezil in human plasma. Analytes and the internal standard were extracted from human plasma by liquid–liquid extraction technique using a 30:70 v/v mixture of ethyl acetate and n‐hexane. The reconstituted samples were chromatographed on a C18 column by using a 70:30 v/v mixture of acetonitrile and ammonium formate (5 mm , pH 5.0) as the mobile phase at a flow rate of 0.6 mL/min. The calibration curve obtained was linear (r ≥ 0.99) over the concentration range of 0.09–24.2 ng/mL for donepezil and 0.03–8.13 ng/mL for 6‐o‐desmethyl donepezil. The results of the intra‐day and inter‐day precision and accuracy studies were well within the acceptable limits. The proposed method was successfully applied for the estimation of the drug in real time plasma samples for pharmacokinetic studies. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
This study aimed at optimizing and validating a sensitive method for simultaneous determination of bisphenol A (BPA), triclosan (TCS), and tetrabromobisphenol A (TBBPA) in human serum using solid-phase extraction (SPE) and gas chromatography coupled to electron-capture negative-ionization mass spectrometry (GC-ECNI/MS). Sample preparation involved denaturation of serum proteins with formic acid followed by SPE on an Oasis HLB cartridge. Fractionation was performed on Florisil from which the phenolic compounds were eluted with methanol-dichloromethane (DCM) (5:1, v/v). The phenolic fraction was further derivatized with pentafluoropropionic acid anhydride (30 min at 70 degrees C). Further liquid-liquid partitioning using hexane-DCM (4:1, v/v) and K(2)CO(3) 3% aqueous solution was used to eliminate excess reagent and acidic by-products formed during derivatization. The cleaned extract was injected into a GC-ECNI/MS system operated in selected ion monitoring mode. For thorough method validation, each step of the procedure was rigorously optimized. The method limits of quantitation for BPA, TCS, and TBBPA were 0.28 ng mL(-1), 0.09 ng mL(-1) and 0.05 ng mL(-1), respectively. Furthermore, the method was applied to 21 Belgian human serum samples. The median concentrations obtained for BPA (0.71 ng mL(-1)) and TCS (0.52 ng mL(-1)) in Belgian human serum samples were similar to previously reported data for human fluids. Slightly higher levels of TBBPA (0.08 ng mL(-1)) were found in Belgium samples compared to Norwegian serum.  相似文献   

8.
A rapid, simple, sensitive and specific LC‐MS/MS method has been developed and validated for the simultaneous estimation of atorvastatin (ATO), amlodipine (AML), ramipril (RAM) and benazepril (BEN) using nevirapine as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under the multiple‐reaction monitoring mode using electrospray ionization. Analytes and IS were extracted from plasma by simple liquid–liquid extraction technique using ethyl acetate. The reconstituted samples were chromatographed on C18 column by pumping 0.1% formic acid–acetonitrile (15:85, v/v) at a flow rate of 1 mL/min. A detailed validation of the method was performed as per the FDA guidelines and the standard curves were found to be linear in the range of 0.26–210 ng/mL for ATO; 0.05–20.5 ng/mL for AML; 0.25–208 ng/mL for RAM and 0.74–607 ng/mL for BEN with mean correlation coefficient of ≥0.99 for each analyte. The intra‐day and inter‐day precision and accuracy results were well with in the acceptable limits. A run time of 2.5 min for each sample made it possible to analyze more than 400 human plasma samples per day. The developed assay method was successfully applied to a pharmacokinetic study in human male volunteers. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
Di‐(2‐ethylhexyl)phthalate (DEHP) was determined in environmental samples such as water and soil. DEHP was extracted from water samples using SPE, whereas for soils pressurized liquid extraction was applied as extraction method, using hexane/acetone (1:1, v/v) as extractant solvent. The use of HPLC coupled to MS provides the basis of the selective determination of DEHP in the analyzed samples. The extraction procedures were validated and good results were found. Recoveries were ranged from 86.0 to 99.8% with RSD lower than 18% and LODs were 0.02 mg/kg and 0.03 μg/L for soils and water, respectively. Finally, the optimized methods were applied to the analysis of real samples and DEHP was not found above the LOQ (0.05 mg/kg) in soil samples whereas it was detected in water samples at concentrations ranging between 0.19 to 0.88 μg/L.  相似文献   

10.
A method has been developed to determine α, β and γ diastereoisomers of hexabromocyclododecane (HBCD), a brominated flame retardant, in sewage sludge, based on the ultrasonic‐assisted extraction (UAE) of samples with dichloromethane–ACN (1:1) and the subsequent clean‐up of extracts by dispersive solid phase extraction with primary–secondary amine. Levels of HBCD diastereoisomers were determined by LC coupled with ESI MS/MS. Evaluation of the matrix effect showed a high ion suppression for all the diastereoisomers studied, which was counteracted by using a mixture of labelled HBCD diastereoisomers as internal standards. This method yielded recoveries in the range of 79.6–112.5% with SDs equal or lower than 9.1 The limits of detection were 0.3 ng/g for α‐ and β‐HBCD and 0.2 ng/g for γ‐HBCD. The developed method was successfully applied to 19 sludge samples collected from the province of Madrid (Spain). In most of the samples, β‐HBCD was below the method detection limit, whereas α‐ and γ‐HBCD were quantified in all of the sludge samples, and γ‐HBCD was the predominant diastereoisomer in 63% of the analyzed samples and α‐HBCD predominated in the rest.  相似文献   

11.
建立了一种同时测定沉积物中不同赋存形态的多溴联苯醚(PBDEs)和四溴双酚A(TBBPA)的分析方法.样品由等体积的丙酮和正己烷混合溶剂抽提得到自由态目标物,再通过碱性水解反应释放束缚态目标化合物.通过调节酸度(pH值)实现PBDEs和TBBPA的分离和提取.PBDEs由复合硅胶柱净化,运用气相色谱-质谱(负离子化学源)-分时段选择离子监测技术测定;TBBPA经重氮甲烷衍生化反应后由酸性硅胶柱预纯化,运用气相色谱-质谱(电子轰击源)-分时段选择离子监测技术测定.8种低溴联苯醚(BDE28,-47,-66,-100,-99,-154,-153,-183),十溴联苯醚(BDE209)和TBBPA的检出限分别为0.6~12.5 pg/g,172 pg/g,4 2 pg/g.方法具有良好的准确度和精确度,回收率均在74%~106%之间,RSD≤10%.对东江沉积物样品的分析表明,本方法能够实现不同形态的PBDEs 和TBBPA的有效检测.  相似文献   

12.
JCC76 is a novel nimesulide analog that selectively inhibits the human epidermal growth factor receptor 2 (HER2) overexpressing breast cancer cell proliferation and tumor progression. To support further pharmacological and toxicological studies of JCC76, a novel and rapid method using liquid chromatography and electrospray ionization tandem mass spectrometry (LC‐ESI‐MS/MS) has been developed and validated for the quantification of the compound in rat plasma. A C18 column was used for chromatographic separation, and the mobile phase was aqueous ammonium formate (pH 3.7; 5 mm )–methanol (1:9, v/v) with an isocratic elution. With a simple liquid–liquid extraction procedure using the mixture of methyl tert‐butyl ether–hexane (1:2, v/v), the mean extraction efficiency of JCC76 in rat plasma was determined as 89.5–97.3% and no obvious matrix effect was observed. This method demonstrated a linear calibration range from 0.3 to 100 ng/mL for JCC76 in rat plasma and a small volume of sample consumption. The intra‐ and inter‐assay accuracy and precision were within ±10%. The pharmacokinetics of JCC76 was also profiled using this validated method in rats. In conclusion, this rapid and sensitive method has been proven to effectively quantify JCC76 for pharmacokinetics study. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

13.
Fat‐soluble vitamins play a pivotal role in the progression of atherosclerosis and the development of cardiovascular disease. Therefore, plasma monitoring of their concentrations may be useful in the diagnosis of these disorders as well as in the process of treatment. The study aimed to develop and validate an HPLC–MS/MS method for determination of retinol, α‐tocopherol, 25‐hydroxyvitamin D2 and 25‐hydroxyvitamin D3 in plasma of patients with cardiovascular disease. The analytes were separated on an HPLC Kinetex F5 column via gradient elution with water and methanol, both containing 0.1% (v/v) formic acid. Detection of the analytes was performed on a triple‐quadrupole MS with multiple reaction monitoring via electrospray ionization. The analytes were isolated from plasma samples with liquid–liquid extraction using hexane. Linearity of the analyte calibration curves was confirmed in the ranges 0.02–2 μg/mL for retinol, 0.5–20 μg/mL for α‐tocopherol, 5–100 ng/mL for 25‐hydroxyvitamin D2 and 2–100 ng/mL for 25‐hydroxyvitamin D3. Intra‐ and inter‐assay precision and accuracy of the method were satisfactory. Short‐ and long‐term stabilities of the analytes were determined. The HPLC‐MS/MS method was applied for the determination of the above fat‐soluble vitamin concentrations in patient plasma as potential markers of the cardiovascular disease progression.  相似文献   

14.
A fast, sensitive, and high‐throughput ultra‐HPLC–MS/MS method has been developed and validated for the simultaneous determination of three main active constituents of Euphorbiae pekinensis Radix in rat plasma. After addition of the internal standard, plasma samples were extracted by liquid–liquid extraction with ethyl acetate/isopropanol (1:1, v/v) and separated on a CAPCELL PAK C18 column (100 × 2.0 mm, 2 μm, Shiseido, Japan), using a gradient mobile phase system of methanol/water. The detection of the analytes was performed on a 4000Q UHPLC–MS/MS system with turbo ion spray source in the negative ion and multiple reaction‐monitoring mode. The linear range was 1.0–1000 ng/mL for 3,3′‐di‐O‐methyl ellagic acid‐4′‐Oβ‐d ‐glucopyranoside (i), 1.5–1500 ng/mL for 3,3′‐di‐O‐methyl ellagic acid‐4′‐Oβ‐d ‐xylopyranoside (ii), and 5.0–5000 ng/mL for 3,3′‐di‐O‐methyl ellagic acid (iii). The intra‐ and interday precision and accuracy of all the analytes were within 15%. The extraction recoveries of the three analytes and internal standard from plasma were all more than 80%. The validated method was first successfully applied to the evaluation of pharmacokinetic parameters of compounds 1 , 2 , and 3 in rat plasma after intragastric administration of the Euphorbiae pekinensis Radix extract.  相似文献   

15.
A simple, rapid, and novel method has been developed and validated for determination of seven indicator polychlorinated biphenyls in water samples by gas chromatography with electron capture detection. 1 L of water samples containing 30 g of anhydrous sodium sulfate was first liquid–liquid extracted with an automated Jipad‐6XB vertical oscillator using n‐hexane/dichloromethane (1:1, v/v). The concentrated extract was cleaned up by dispersive solid‐phase extraction with 100 mg of primary secondary amine as sorbent material. The linearity of this method ranged from 1.25 to 100 μg/L, with regression coefficients ranging between 0.9994 and 0.9999. The limits of detection were in the ng/L level, ranging between 0.2 and 0.3 ng/L. The recoveries of seven spiked polychlorinated biphenyls with external calibration method at different concentration levels in tap water, lake water, and sea water were in the ranges of 85–112, 76–116, and 72–108%, respectively, and with relative standard deviations of 3.3–4.5, 3.4–5.6, and 3.1–4.8% (n =  5), respectively. The performance of the proposed method was compared with traditional liquid–liquid extraction and solid‐phase extraction clean‐up methods, and comparable efficiencies were obtained. It is concluded that this method can be successfully applied for the determination of polychlorinated biphenyls in different water samples.  相似文献   

16.
A sensitive LC‐MS/MS method was developed and validated for simultaneous quantification of 11 constituents, ginsenoside Rg1, Re, Rf, Rg2, Rb1, Rd, Rc, ophiopogonin D, schisandrin, schisandrol B and schizandrin B, in rat serum using digoxin as the internal standard (IS). The serum samples were pretreated and extracted with a two‐step liquid–liquid extraction. Chromatographic separation was achieved on a C18 analytical column with a proper gradient elution using 0.02% acetic acid aqueous solution and 0.02% acetic acid–acetonitrile as mobile phase at a flow rate of 0.5 mL/min. MS detection was performed using multiple reaction monitoring via an electrospray ionization source. Good linearity was observed in the validated concentration range for every analyte (r2 ≥0.9929), and the lower limits of quantitation of the analytes were in the range of 0.044–1.190 ng/mL in rat serum. Intra‐ and inter‐day precisions were <14.2%. The accuracy expressed as recovery was within the range of 85.1–112.8%. The extraction recoveries were >75.8%.The validated method was successfully applied to a pharmacokinetic study of all analytes in rats after single intravenous administration of Shengmai injection. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
In this paper, a rapid and simple method for the analysis of polybrominated diphenyl ethers (PBDEs) in house dust samples based on microwave-assisted solvent extraction (MASE) and gas chromatography-tandem mass spectrometry (GC-MS/MS) is presented. Extraction conditions were optimized using a multifactorial experimental design approach. The use of an aqueous NaOH phase in combination with a non-polar organic phase (hexane) to extract the target analytes from dust allowed an efficient extraction and reduced chromatographic background. The final hexane extracts could be analyzed after a simple one-step cleanup procedure using Florisil. The validation of the method was performed in terms of accuracy, linearity, and repeatability. The limits of detection (LODs) ranged from 0.29 to 0.55 ng/g for all compounds. The target PBDEs were found in several real dust samples collected in urban and rural houses of Northwestern Spain.  相似文献   

18.
A method to determine 21 organochlorine pesticides in vegetation samples using microwave-assisted extraction (MAE) is described and compared with Soxhlet extraction. Samples were extracted with hexane–acetone (1:1, v/v) and the extracts were cleaned using solid-phase extraction with Florisil and alumine as adsorbents. Pesticides were eluted with hexane–ethyl acetate (80:20, v/v) and determined by gas chromatography and electron-capture detection. Recoveries obtained (75.5–132.7% for Soxhlet extraction and 81.5–108.4% for MAE) show that both methods are suitable for the determination of chlorinated pesticides in vegetation samples. The method using microwave energy was applied to grass samples from parks of A Coruña (N.W. Spain) and to vegetation from the contaminated industrial area of Torneiros (Pontevedra, N.W. Spain).  相似文献   

19.
A rapid and sensitive LC‐MS/MS method for the quantification of fenofibric acid in rat plasma was developed and validated. Plasma samples were prepared by liquid–liquid extraction with a mixture of N‐hexane–dichloromethane–isopropanol (100:50:5, v/v/v). Isocratic chromatographic separation was performed on a reversed‐phase Discovery C18 column (2.1 × 50 mm, 5 µm). The mobile phase was methanol–water–formic (75:25:0.25, v/v/v). Detection of fenofibric acid and the internal standard (IS) diclofenac acid was achieved by ESI MS/MS in the negative ion mode using m/z 317 → m/z 213 and m/z 294 → m/z 250 transitions, respectively. The method was linear from 0.005 to 1.250 µg/mL when 100 μL plasma was analyzed. The lower limit of quantification was 0.005 µg/mL. The intra‐ and inter‐day precision values were below 8.2%, and accuracy ranged from ?0.9 to 2.1% in all quality control samples. The recovery was 90.3–94.7% and 83.3% for fenofibric acid and IS, respectively. Total run time for each sample analysis was 2.5 min. The validated method was successfully applied to a pharmacokinetic study in six rats after oral administration of fenofibrate, the ester prodrug of fenofibric acid (equivalent to fenofibric acid 5 mg/kg). The method permits laboratory scientists with access to the appropriate instrumentation to perform rapid fenofibric acid determination. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

20.
Analysis of 11 polybrominated diphenyl ethers (PBDEs), tetrabromobisphenol A bis 2,3-dibromopropylether (TBBPA-bis), tetrachlorobisphenol A (TCBPA), tetrabromobisphenol A (TBBPA) and hexabromocyclododecanes (HBCDs) was optimized by ultrahigh pressure liquid chromatography/tandem mass spectrometry (UPLC–MS/MS) operating in negative ion (NI) mode. Electrospray ionization (ESI), atmospheric pressure photoionization (APPI) and atmospheric pressure chemical ionization (APCI) sources were tested and for PBDEs APCI gave higher sensitivity than APPI while for TBBPA-bis APCI and APPI showed similar performance. ESI was the best option for TCBPA, TBBPA and HBCDs. Detection limits were between 20 and 59 fg for the compounds analyzed by ESI, 0.10 and 0.72 pg for PBDEs and 6 pg for TBBPA-bis. The matrix effect of sewage sludge extract was also tested showing negligible ion suppression for APCI and an increase of the background level of all investigated pollutants leading to a worsening of the limits of quantification by a factor between 1.2 and 3.3. The UPLC-APCI/MS/MS method for PBDEs, after pressurized liquid extraction (PLE), was validated by comparison with the concentration values from the NIST 1944 standard reference material. The advantages of the methods include low detection limits, PBDE congeners specificity using selected multiple reaction monitoring (MRM) transitions, and the absence of thermal degradation of higher PBDE congeners, especially BDE-209. The methods were applied for the determination of the above reported flame retardants in sewage sludge in order to get more information about the degradation on PBDEs (in particular BDE-209) during municipal wastewater treatments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号