首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A piezoelectric crystal immunosensor has been developed for the detection and determination of cortisol. Cortisol antibody was layered onto the gold electrodes of a 10 MHz piezoelectric crystal which was pre-coated with either protein A or gluteraldehyde. Crystals pre-coated with protein A showed the best results with respect to stability and sensitivity. The sensor was successfully used for the determination of cortisol in standard solutions from 36-3628 micrograms/L (part per billion). The advantages of the proposed sensor include simplicity, short analysis time, cost effectiveness and selectivity. The results demonstrate the feasibility of cortisol assay in clinical testing and in drug monitoring.  相似文献   

2.
《Analytical letters》2012,45(12):2149-2159
Abstract

A piezoelectric crystal immunosensor has been developed for the detection and determination of cortisol. Cortisol antibody was layered onto the gold electrodes of a 10 MHz piezoelectric crystal which was precoated with either protein A or gluteraldehyde. Crystals pre-coated with protein A showed the best results with respect to stability and sensitivity.

The sensor was successfully used for the determination of cortisol in standard solutions from 36–3628 μg/L (part per billion). The advantages of the proposed sensor include simplicity, short analysis time, cost effectiveness and selectivity. The results demonstrate the feasibility of cortisol assay in clinical testing and in drug monitoring.  相似文献   

3.
Shen GY  Wang H  Deng T  Shen GL  Yu RQ 《Talanta》2005,67(1):217-220
A simple, rapid, and highly sensitive immunosensor for the direct determination of carcinoembryonic antigen (CEA) in human serum using a piezoelectric crystal has been developed and optimized. In order to improve sensitivity of the immunosensor, a protein A-based orientation-controlled immobilization method for antibodies was adopted together with an immunoreactive accelerant of polyethyleneglycol (PEG) used to amplify the signal response of frequency. Human normal serum was utilized as a reference background. The linear range for CEA concentration obtained by the end-point method was 66.7-466.7 ng/mL. Clinical samples from cancer patients were analyzed by the proposed piezoelectric immunoassay, and the analytical results were reasonably comparable with those obtained by the chemiluminescence immunoassay (CLIA). The proposed immunosensor provides a new promising method for the highly sensitive immunoassay of CEA in clinical laboratory.  相似文献   

4.
 To obtain new coatings for the preparation of piezoelectric immunosensors, the anodic polymerization of o-aminophenol (oAP), o-phenylenediamine (oPD) and m-phenylenediamine (mPD) onto a gold-plated crystal has been studied. The possibility of immobilizing an antibody (anti-S. paratyphi A) onto the crystal via the electropolymerized films was investigated. The poly-mPD film gave the best results for immobilizing the antibody. With antibodies crosslinked on the poly-mPD film, a piezoelectric immuno-assay for the detection of S. paratyphi A was proposed. The shift (ΔF=F20s−F400s, Hz) between the frequency at 20 s after the addition of sample (F20s), and that of 400 s (F400s) was used to construct a calibration graph, and shortening of the assay time was achieved. The S. paratyphi A concentration in the range of 105–109 cells/ml can be measured by this method. Received: 9 May 1996/Revised: 6 September 1996/Accepted: 19 September 1996  相似文献   

5.
 To obtain new coatings for the preparation of piezoelectric immunosensors, the anodic polymerization of o-aminophenol (oAP), o-phenylenediamine (oPD) and m-phenylenediamine (mPD) onto a gold-plated crystal has been studied. The possibility of immobilizing an antibody (anti-S. paratyphi A) onto the crystal via the electropolymerized films was investigated. The poly-mPD film gave the best results for immobilizing the antibody. With antibodies crosslinked on the poly-mPD film, a piezoelectric immuno-assay for the detection of S. paratyphi A was proposed. The shift (ΔF=F20s−F400s, Hz) between the frequency at 20 s after the addition of sample (F20s), and that of 400 s (F400s) was used to construct a calibration graph, and shortening of the assay time was achieved. The S. paratyphi A concentration in the range of 105–109 cells/ml can be measured by this method. Received: 9 May 1996/Revised: 6 September 1996/Accepted: 19 September 1996  相似文献   

6.
A novel method of immobilizing antibodies on piezoelectric crystal (P/Z) sensor was developed based on self-assembled monolayer (SAM) using alkanethiols for immunosensing. The assembly of SAMs on metal surface is relatively easy and they are closely packed, well ordered and stable in ambient conditions. Thus,SAMs are good candidates for immobilizing biomolecules onto ultrathin layers.  相似文献   

7.
A piezoelectric immunosensor has been developed for the detection of complement C4. Anti-C4 antibody was immobilized onto the gold electrodes of a 9 MHz AT-cut piezoelectric crystal. The coated crystal with the physical adsorption method to immobilize antibody showed the better results than the polyethyleneimine adhesion, glutaraldehyde cross-linking method with respect to sensitivity and reproducibility. The antibody-bound crystal with the physical adsorption method was successfully used for the detection of human complement C4 in the concentration range of 0.1-10 μg/mL for 40 min incubation time. The immunosensor system had good selectivity, and other materials in human serum did not interfere the detection remarkably. The crystal could be regenerated nearly 15 times when the bound materials on the crystal surface were eluted by strong acid and strong alkali solutions and subsequently cleaned in a ultrasonic cleaner.  相似文献   

8.
A method has been developed to monitor the interaction between a lipopolysaccharide (LPS) and LPS-binding peptides using a piezoelectric quartz crystal (PQC). Different pH conditions were evaluated to coat LPS onto AT-cut crystals that had been sputtered with gold and carboxylated with a 4,4-dithiodi(n-butyric acid). The optimal pH for LPS coating onto the crystal was 4–5. Synthetic peptides that represent different regions of human bactericidal/permeability-increasing protein, BPI (BPI 85–99, BPI 90–101, BPI 157–167) and polymyxin B (PmB) as well as negative control peptide (HBsAg 139–147) were utilized to compare their binding ability to this LPS-coated PQC sensor. The results showed that PmB gave the greatest decrease to the resonant frequency indicating greatest binding ability. BPI 85–299, considered the main part of the LPS binding domain of BPI, was the next greatest, while BPI 157–167 and HBsAg 139–147 showed little response. In addition, BPI 90–101 and PmB-mimicking peptide showed intermediate LPS-binding ability, which was less than that of BPI 85–99, but was higher than that of BPI 157–167. These results suggest the PQC biosensor is potentially useful for the detection and comparison of the LPS-binding ability of different peptides by using an LPS-coated piezoelectric crystal.  相似文献   

9.
A novel piezoelectric immunosensor has been developed for the detection of human complement C1-inhibitor. Anti-C1-inhibitor antibody was immobilized onto the gold electrodes of a 9 MHz AT-cut piezoelectric crystal. Coating the crystal with polyethyleneimine adhesion, followed by a glutaraldehyde cross-linking method to immobilize antibody showed better results than the physical adsorption method with respect to sensitivity and reproducibility. Under the optimized experimental conditions, the sensor showed good response to the C1-inhibitor in the range from 2.0 x 10(-8) to 1.2 x 10(-6) g. Other proteins in human serum did not remarkably interfere with the detection. The crystals could be regenerated 5 times, when bound materials on the crystal surface were eluted by strong acid and strong alkali solution and subsequently cleaned in an ultrasonic cleaner.  相似文献   

10.
The adsorption behavior of 5,10,15,20-tetrakis (4-N-methylpyridiniumyl)-porphyrin (H2TMPyP) from aqueous solutions onto a quartz crystal interface was investigated in situ using an electrode-separated piezoelectric sensor (ESPS). With H2TMPyP adsorbed onto quartz crystal surface of the ESPS, its oscillating frequency decreases linearly with increasing adsorption amount. The adsorption densities obtained in the ESPS method were greater than those determined in a solution depletion method. The influence of surface roughness of quartz crystal and bulk solution properties on the measurement of adsorption density in the ESPS method was discussed.  相似文献   

11.
A method for immunoassay of CRP (C-reactive protein) was developed using a piezoelectric quartz crystal. Previous immunoassays using a piezoelectric crystal have required the formation of a thin film on the crystal, to which an antibody is affixed. The occurrence of antigen-antibody reaction increases the weight attached to the crystal surface, which causes a reduction in the oscillation frequency. In our method, the frequency reduction was observed using antibody-bearing latex without any film. One possible mechanism of the frequency change is that the crystal acts as a sensing apparatus for viscosity or density change in the solution due to aggregation of latex particles. The detection limit was almost the same as that for latex photometric immunoassay (LPIA). The present method has been designated as latex piezoelectric immunoassay (LPEIA).  相似文献   

12.
The immobilization of alcohol dehydrogenase (ADH) on Au-colloid modified gold electrodes has been investigated. Colloidal Au was first self-assembled onto gold electrodes through the thiol groups of an 1,6-hexanedithiol monolayer. Piezoelectric quartz crystal sensor, cyclic voltammetry, and electrochemical impedance techniques were used to investigate the immobilization of ADH on Au colloids. The cyclic voltammogram tends to be more irreversible with increased ADH concentration. In the impedance spectroscopic study, an obvious difference of the electron transfer resistance between the Au-colloid modified electrode and the bare gold electrode was observed. Using the piezoelectric quartz crystal sensor, the Michaelis constant, K(m), and the maximum initial rate, V(max), of the immobilized ADH were estimated as 6.03 x 10(-4) M and 0.63 Hzs (-1), respectively. The binding constant of ADH with nicotinamide adenine dinucleotide (NAD) was also determined as 1.87 x 10(4) M(-1). Experimental results showed that colloidal Au can be used as a biocompatible matrix for enzyme immobilization.  相似文献   

13.
The adsorption process of dodecylammonium chloride (DAC) from aqueous solutions onto a quartz crystal interface was investigated in situ using an electrode-separated piezoelectric sensor (ESPS). Increasing amounts of DAC adsorbed onto a quartz crystal surface resulted in linearly decreasing oscillating frequencies of the ESPS. The adsorption density can be monitored by the frequency decrease. The adsorption density obtained by calculation using the Sauerbrey equation in the ESPS method is greater than that in solution depletion method. A calibration coefficient is added into the Sauerbrey equation to correct the influence of surface roughness of the quartz crystal on the adsorption density. The influence of solution properties on the adsorption density measurement was discussed. A dependence of the adsorption density on pH was reported. Received: 17 April 1997 / Revised: 1 December 1997 / Accepted: 7 December 1997  相似文献   

14.
The adsorption process of dodecylammonium chloride (DAC) from aqueous solutions onto a quartz crystal interface was investigated in situ using an electrode-separated piezoelectric sensor (ESPS). Increasing amounts of DAC adsorbed onto a quartz crystal surface resulted in linearly decreasing oscillating frequencies of the ESPS. The adsorption density can be monitored by the frequency decrease. The adsorption density obtained by calculation using the Sauerbrey equation in the ESPS method is greater than that in solution depletion method. A calibration coefficient is added into the Sauerbrey equation to correct the influence of surface roughness of the quartz crystal on the adsorption density. The influence of solution properties on the adsorption density measurement was discussed. A dependence of the adsorption density on pH was reported. Received: 17 April 1997 / Revised: 1 December 1997 / Accepted: 7 December 1997  相似文献   

15.
A novel piezoelectric immunosensor has been developed for the detection of human complement C1-inhibitor. Anti-C1-inhibitor antibody was immobilized onto the gold electrodes of a 9 MHz AT-cut piezoelectric crystal. Coating the crystal with polyethyleneimine adhesion, followed by a glutaraldehyde cross-linking method to immobilize antibody showed better results than the physical adsorption method with respect to sensitivity and reproducibility. Under the optimized experimental conditions, the sensor showed good response to the C1-inhibitor in the range from 2.0 × 10–8 to 1.2 × 10–6 g. Other proteins in human serum did not remarkably interfere with the detection. The crystals could be regenerated 5 times, when bound materials on the crystal surface were eluted by strong acid and strong alkali solution and subsequently cleaned in an ultrasonic cleaner.  相似文献   

16.
压电免疫质量传感器中生物大分子的固定化方法   总被引:9,自引:0,他引:9  
许博  朱果逸 《分析化学》1999,27(4):479-484
评述了近十几年来压电免疫质量传感器研究中的关键技术-生物分子固定化方法的研究应用,并对固定化方法的发展予以展望。  相似文献   

17.
Ying-Sing F  Shi-Hui S  De-Rong Z 《Talanta》2000,51(1):151-158
A polymer sorbent formed at the surface of gold-plated piezoelectric crystal by anodic oxidation of m-aminophenol was investigated by voltammetric, FTIR techniques for antibody coupling after activation by divinylsulphone. A novel film with increased capacity for immobilizing antibodies was obtained using phloroglucinol to modify poly-m-aminophenol via divinylsulphone. Compared with the dip-coating methods using polyethylenimine and (gamma-aminopropyl)trimethoxysilane, this new technique gave more reproducible results for the immobilization of antibody from sample to sample due to the improved homogeneity and reproducibility of the coating. With present modification method, a piezoelectric immunosensor was developed for the detection of Salmonella enteritidis. A detection limit of 1x10(5) cells ml(-1) and an assay time of 25 min were achieved.  相似文献   

18.
Xu Y  Lu C  Chen K  Nie L  Yao S 《Talanta》1996,43(8):1297-1303
A new piezoelectric crystal impedance sensor for the determination of sulphur dioxide in aqueous solution is presented. It is realized using a series piezoelectric crystal device which is constructed by connecting an AT-cut piezoelectric crystal to a probe in series. The probe is filled with an internal electrolyte solution that is separated from sample solutions by a gas-permeable membrane. The present sensor exhibits a favourable frequency response to 1 x 10(-7)-1 x 10(-3) M sulphur dioxide. The detection limit is 1 x 10(-8) M. The effects of the sensor preparation are considered. Dynamic range, reproducibility, response time and selectivity of the sensor are also discussed. The proposed sensor has been used successfully for lamp sulphur determinations in petroleum samples.  相似文献   

19.
A glucose-sensing system was developed in which an electrodeless piezoelectric quartz crystal was used to measure mass changes on the surface of a quartz plate during the reduction of Ag(NH3)+2 by glucose. A satisfactory correlation was obtained between the frequency shift and the glucose concentration in the range 1.0–25 mM, and the total reducing sugar in urine was determined. Treatment with 8 M nitric acid after each measurement was effective for cleaning the quartz surface, and the electrodeless piezoelectric quartz crystal sensor possessed excellent reproducibility and reusability during repeated use over 400 times. For the determination of total reducing sugar in urine (or blood), the present method can avoid the interferences occurring in a colorimetric method such as the color and turbidity of clinical specimens.  相似文献   

20.
The C60—polycinnamaldehyde (C60—PCA) and C60—polyphenylacetylene (C60—PPA) polymers were synthesized by the Friedel—Craft reaction and applied as piezoelectric (PZ) quartz crystal coating materials. A C60—polycinnamaldehyde (PCA) coated piezoelectric quartz crystal liquid sensor with a homemade computer interface was prepared and applied as a PZ hemoglobin sensor. The adsorption of hemoglobin onto the C60—PCA coated crystal resulted in a decreased oscillating frequency. The variations in crystal frequency were converted to voltage with a frequency to voltage converter, followed by amplification with OPA and data acquisition with an analog to digital converter. The PZ hemoglobin sensor exhibited good sensitivity of 6530 Hz/(mg/mL) with a detection limit at the ppm level for hemoglobin. Further, a C60—polyphenylacetylene (C60—PPA) coated piezoelectric quartz crystal gas sensor with an Intell‐8255 data processing system for various olefin vapors was also made. The aromatic hydrocarbons such as toluene seem to have greater adsorption onto C60—PPA membrane than alkynes, alkenes, and alkanes. The adsorption of polycyclic aromatic hydrocarbons (PAHs) onto the C60—PPA membrane was also examined. The C60—PPA coated PZ crystal gas sensor showed much better sensitivity for PAHs than for other olefins such as toluene, 1‐hexyne and 1‐hexene, and a much larger frequency shift for naphthalene than other PAHs was also found.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏