首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 515 毫秒
1.
By one‐step co‐electrodeposition CaCO3 nanoparticles‐chitosan composite film on carbon ionic liquid electrode (CILE), and then by spreading the composition of hemoglobin (Hb) and chitosan on the nanoCaCO3‐chi/CILE, a Hb‐chi/nanoCaCO3‐chi/CILE was fabricated and the direct electrochemistry and electrocatalysis of Hb at the electrode was investigated. The electrochemical impedance spectroscopy of the modified electrode showed the electron transfer resistance was 1166 Ω. Investigation results of cyclic voltammetrys showed a pair of well‐defined and quasireversible redox peak of Hb with the formal potentials of ‐0.295 V (vs. SCE) in 0.1 mol·L‐1 pH 7.0 PBS; the response time of the reduction peak currents of Hb was lower than 3s; a linear range for determination of H2O2 was from 5.0 μmol·L‐1 to 1.3 mmol·L‐1 with a detection limit of 1.6 μmol·L‐1 (S/N = 3) and a sensitivity of 0.16 A·M‐1·cm‐2; the electron transfer rate constant and the apparent Michaelis‐Menten constant of Hb were 1.98 s‐1 and 0.81 mmol·L‐1, respectively. As a result, the case of the one‐step co‐electrodeposition and the promising feature of biocomposite could serve as a versatile platform for the fabrication of electrochemical biosensors.  相似文献   

2.
In this article, an electrochemical sensor based on a gold nanocage (AuNC)‐modified carbon ionic liquid electrode (CILE) was fabricated and applied to the sensitive rutin determination. The presence of AuNCs on the electrode surface greatly improved the electrochemical performance of the working electrode due to its specific microstructure and high metal conductivity. Electrochemical behavior of rutin on AuNCs/CILE was studied using cyclic voltammetry and differential pulse voltammetry with the related electrochemical parameters calculated. Under the optimal experimental conditions, the oxidation peak current of rutin and its concentration had good linear relationship in the range from 4.0 × 10?9 to 7.0 × 10?4 mol/L with a low detection limit of 1.33 × 10?9 mol/L (3σ). This fabricated AuNCs/CILE was applied to direct detection of the rutin concentration in drug samples with satisfactory results, showing the real application of AuNCs in the field of chemically modified electrodes.  相似文献   

3.
The preparation and characterisation of a new composite electrode with Co3O4 particles-modified multi-walled carbon nanotube (MWCNT) and poly(phenosafranine), as well as its novel application for the voltammetric detection of rutin was described. The resulting composite electrode was characterised using scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and electrochemical impedance spectroscopy (EIS). In the optimised experimental conditions, the oxidation peak current (Ipa) of rutin showed a linear increase in concentration, between 0.008–0.6 and 0.80–6.0 μmol L−1, with a detection limit of 0.00379 μmol L−1. Due to its good selectivity and stability, the composite electrode was successfully applied in detecting rutin in pharmaceutical formulations.  相似文献   

4.
In this paper an ionic liquid modified carbon paste electrode (CILE) was prepared and methylene blue (MB) was electropolymerized on the CILE by using the cyclic voltammetric technique in the potential range from −1.0 V to 0.8 V (vs. SCE). A stable polymer film was obtained and exhibited a pair of redox peaks. The morphology and characteristics of poly(methylene blue) (PMB) film was studied by the techniques such as scanning electron microscopy and electrochemical impedance spectroscopy. This PMB modified CILE (PMB/CILE) showed excellent electrocatalytic response to 3,4‐dihydroxybenzoic acid with the increase of the electrochemical responses. The oxidation peak current had a linear relationship with 3,4‐dihydroxybenzoic acid concentration in the range of 5.0 × 10−4 ∼ 3.0 × 10−2 mol L−1 and the detection limit was 1.72 × 10−4 Mol L−1 (3 σ).  相似文献   

5.
In this paper a graphene (GR) modified carbon ionic liquid electrode (CILE) was fabricated and used as the voltammetric sensor for the sensitive detection of catechol. Due to the specific physicochemical characteristics of GR such as high surface area, excellent conductivity and good electrochemical properties, the modified electrode exhibits rapid response and strong catalytic activity with high stability toward the electrochemical oxidation of catechol. A pair of well‐defined redox peaks appeared with the anodic and the cathodic peak potential located at 225 mV and 133 mV (vs.SCE) in pH 6.5 phosphate buffer solution, respectively. Electrochemical behaviors of catechol on the GR modified CILE were carefully investigated and the electrochemical parameters were calculated with the results of the electrode reaction standard rate constant (ks) as 1.24 s?1, the charge transfer coefficient (α) as 0.4 and the electron transfer number (n) as 2. Under the selected conditions the differential pulse voltammetric peak current increased linearly with the catechol concentrations in the range from 1.0 × 10‐7 to 7.0 × 10?4mol L‐1 with the detection limit as 3.0 × 10?8mol L‐1 (3σ). The proposed method was further applied to the synthetic waste water samples determination with satisfactory results  相似文献   

6.
In this paper a room temperature ionic liquid 1‐butyl‐3‐methylimidazolium hexafluorophosphate (BMIMPF6) was used as binder for the construction of carbon ionic liquid electrode (CILE) and a new electrochemical biosensor was developed for determination of H2O2 by immobilization of hemoglobin (Hb) in the composite film of Nafion/nano‐CaCO3 on the surface of CILE. The Hb modified electrode showed a pair of well‐defined, quasi‐reversible redox peaks with Epa and Epc as ?0.265 V and ?0.470 V (vs. SCE). The formal potential (E°′) was got by the midpoint of Epa and Epc as ?0.368 V, which was the characteristic of Hb Fe(III)/Fe(II) redox couples. The peak to peak separation was 205 mV in pH 7.0 Britton–Robinson (B–R) buffer solution at the scan rate of 100 mV/s. The direct electrochemistry of Hb in the film was carefully investigated and the electrochemical parameters of Hb on the modified electrode were calculated as α=0.487 and ks=0.128 s?1. The Nafion/nano‐CaCO3/Hb film electrode showed good electrocatalysis to the reduction of H2O2 in the linear range from 8.0 to 240.0 μmol/L and the detection limit as 5.0 μmol/L (3σ). The apparent Michaelis–Menten constant (KMapp) was estimated to be 65.7 μmol/L. UV‐vis absorption spectroscopy and FT‐IR spectroscopy showed that Hb in the Nafion/nano‐CaCO3 composite film could retain its native structure.  相似文献   

7.
《Electroanalysis》2018,30(9):2085-2093
In this work, a novel redox capacitor was designed for signal amplification in electrochemical detection. It was fabricated by co‐electrodeposition of a conducting polymer, sulfonated polyaniline (SPAN) and chitosan on a glass carbon electrode, and its function was evaluated for being a localized source to transfer electron between FcCOOH (Fc) and Ru(NH3)6Cl3 in solution via redox cycling. Furthermore, the electrochemical detection of chloramphenicol, a broad‐spectrum antibiotic was performed using the redox capacitor in the presence of Fc. A significant amplification in cathodic current response of chloramphenicol was obtained through a continuous redox‐cycling reaction. The performance of the amplifying signal responded linearly to chloramphenicol in a concentration range of 0.05 to 50.0 μmol L−1 with a low detection limit of 0.01 μmol L−1. The proposed approach exhibited good reproducibility and stability, and could be used for detection of chloramphenicol in eye drops by standard addition method with the recoveries from 96.5 % to 103.0 %.  相似文献   

8.
In this work a partially reduced graphene oxide (p‐RGO) modified carbon ionic liquid electrode (CILE) was prepared as the platform to fabricate an electrochemical DNA sensor, which was used for the sensitive detection of target ssDNA sequence related to transgenic soybean A2704‐12 sequence. The CILE was fabricated by using 1‐butylpyridinium hexafluorophosphate as the binder and then p‐RGO was deposited on the surface of CILE by controlling the electroreduction conditions. NH2 modified ssDNA probe sequences were immobilized on the electrode surface via covalent bonds between the unreduced oxygen groups on the p‐RGO surface and the amine group at the 5′‐end of ssDNA, which was denoted as ssDNA/p‐RGO/CILE and further used to hybridize with the target ssDNA sequence. Methylene blue (MB) was used as electrochemical indicator to monitor the DNA hybridization. The reduction peak current of MB after hybridization was proportional to the concentration of target A2704‐12 ssDNA sequences in the range from 1.0×10?12 to 1.0×10?6 mol/L with a detection limit of 2.9×10?13 mol/L (3σ). The electrochemical DNA biosensor was further used for the detection of PCR products of transgenic soybean with satisfactory results.  相似文献   

9.
In this paper, a Fe3O4@SiO2 core-shell structure microsphere was synthesized and used to investigate the direct electron transfer of myoglobin (Mb) with a 1-butylpyridinium hexafluorophosphate based carbon ionic liquid electrode (CILE) as the substrate electrode. The mixture of Mb and Fe3O4@SiO2 microsphere could form an organic–inorganic composite, which was immobilized on the surface of CILE with a chitosan (CS) film. Cyclic voltammetric experiments indicated that a pair of well-defined quasi-reversible redox peaks appeared on CS/Mb-Fe3O4@SiO2/CILE with the formal peak potential (E 0′) located at ?0.31 V (vs. saturated calomel electrode), which was corresponded to the electroactive center of Mb heme Fe(III)/Fe(II) redox couples. Direct electrochemical behaviors of Mb in CS-Fe3O4@SiO2 composite film were carefully investigated with the electrochemical parameters calculated. The CS/Mb-Fe3O4@SiO2/CILE showed good electrocatalytic behaviors to the reduction of trichloroacetic acid in the concentration range from 0.2 to 11.0 mmol L?1 with the detection limit of 0.18 mmol L?1 (3σ). Based on CS/Mb-Fe3O4@SiO2/CILE, a new third-generation reagentless electrochemical biosensor was constructed with higher sensitivity and reproducibility.  相似文献   

10.
Direct electron transfer of myoglobin (Mb) was achieved by its direct immobilization on carbon ionic liquid electrode (CILE) with a conductive hydrophobic ionic liquid, 1‐butyl pyridinium hexaflourophosphate ([BuPy][PF6]) as binder for the first time. A pair of well‐defined, quasi‐reversible redox peaks was observed for Mb/CILE resulting from Mb redox of heme Fe(III)/Fe(II) redox couple in 0.1 M phosphate buffer solution (pH 7.0) with oxidation potential of ?0.277 V, reduction potential of ?0.388 V, the formal potential E°′ (E°′=(Epa+Epc)/2) at ?0.332 V and the peak‐to‐peak potential separation of 0.111 V at 0.5 V/s. The average surface coverage of the electroactive Mb immobilized on the electrode surface was calculated as 1.06±0.03×10?9 mol cm?2. Mb retained its bioactivity on modified electrode and showed excellent electrocatalytic activity towards the reduction of H2O2. The cathodic peak current of Mb was linear to H2O2 concentration in the range from 6.0 μM to 160 μM with a detection limit of 2.0 μM (S/N=3). The apparent Michaelis–Menten constant (K and the electron transfer rate constant (ks) were estimated to be 140±1 μM and 2.8±0.1 s?1, respectively. The biosensor achieved the direct electrochemistry of Mb on CILE without the help of any supporting film or any electron mediator.  相似文献   

11.
An ionic liquid N‐hexylpyridinium hexafluorophosphate (HPPF6) modified carbon paste electrode was fabricated for the sensitive voltammetric determination of adenosine in this paper. Carbon ionic liquid electrode (CILE) was prepared by mixing graphite powder and HPPF6 together and the CILE was characterized by scanning electron microscopy (SEM) and electrochemical methods. The electrochemical behaviors of adenosine on the CILE were studied carefully. Compared with the traditional carbon paste electrode (CPE), a small negative shift of the oxidation peak potential appeared with greatly increase of the oxidation peak current, which indicated the presence of ionic liquid in the carbon paste not only as the binder but also as the modifier and promoter. Under the optimal conditions the oxidation peak current increased with the adenosine concentration in the range from 1.0×10?6 mol/L to 1.4×10?4 mol/L with the detection limit of 9.1×10?7 mol/L (S/N=3) by differential pulse voltammetry. The proposed method was applied to the human urine samples detection with satisfactory results.  相似文献   

12.
A carbon ionic liquid electrode (CILE) was modified with a polythionine (PTh)/multi-walled carbon nanotubes (MWCNTs) composite and used for the detection of reduced nicotinamide adenine dinucleotide (NADH). The electrode was prepared by electrochemical polymerization of thionine on the MWCNTs in neutral medium. Cyclic voltammetry indicated that the electrode was capable of mediating the oxidation of NADH at an overpotential as low as 0.03 V. Amperometric experiments showed that a sensitive and stable response towards NADH is obtained within 5 s. The linear range for the determination of NADH is from 0.8 μmol L?1 to 422 μmol L?1, with a detection limit of 0.26 μmol L?1 (S/N = 3). The wide linear range, lower detection limit and faster response towards NADH suggests that the new method potentially is useful for developing NAD+-dependent enzyme-based biosensors.  相似文献   

13.
A sensitive electrochemical method was proposed for the determination of adenosine-5′-diphosphate (ADP) on an ionic liquid (IL) 1-(3-chloro-2-hydroxy-propyl)-3-methylimidazole chloride modified carbon paste electrode (CPE) in a pH 4.5 Britton-Robinson (B-R) buffer solution. Compared with CPE, IL modified CPE (CILE) showed strong electrocatalytic ability to promote the electrochemical oxidation of ADP. A well-defined irreversible oxidation peak of ADP appeared at +1.381 V with an adsorption-controlled process, which was due to the presence of high conductive IL on the electrode. The experimental conditions were optimized and the electrochemical parameters of ADP were calculated with the electron transfer coefficient (α) as 0.293, the electron transfer number (n) as 1.23, the apparent heterogeneous electron transfer rate constant (k s) as 3.325 × 10?6 s?1 and the surface coverage (ΓT) as 0.92 × 10?8 mol/cm2. Under the optimum conditions, the oxidation peak current was linear to ADP concentration in the range from 3.0 to 1000.0 μmol/L with the detection limit as 2.78 μmol/L (3σ) by differential pulse voltammetry. The CILE also eliminated the interferences of commonly coexisting substances and was successfully applied to detect the ADP artificial samples.  相似文献   

14.
《Electroanalysis》2006,18(10):1028-1034
This paper presents a comparative study on the electrochemical behavior of the flavonoid rutin on a rigid carbon‐polyurethane composite electrode and on a glassy carbon electrode. The electrochemical oxidation reaction of rutin was found to be quasireversible and affected by adsorption on the electrode surface. A square‐wave voltammetric method was developed for determination of rutin in green tea infusion samples using the RCPE electrode and data treatment by a deconvolution procedure. The detection limit achieved in buffered solutions was 7.1×10?9 mol L?1 using the RCPE and 1.7×10?8 mol L?1 using the GC electrode the average reproducibility for five determinations being 3.5%.  相似文献   

15.
In this paper a carbon ionic liquid electrode (CILE) was fabricated by using ionic liquid 1‐ethyl‐3‐methylimidazolium ethylsulphate ([EMIM]EtOSO3) as the modifier and further used as the working electrode for the sensitive anodic stripping voltammetric detection of Pb2+. The characteristics of the CILE were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). In pH 4.5 NaAc‐HAc buffer Pb2+ was accumulated on the surface of CILE due to the extraction effect of IL and reduced at a negative potential (‐1.20 V). Then the reduced Pb was oxidized by differential pulse anodic stripping voltammetry with an obvious stripping peak appeared at ?0.67 V. Under the optimal conditions Pb2+ could be detected in the concentration range from 1.0 × 10?8 mol/L to 1.0 × 10?6 mol/L with the linear regression equation as Ip(μA) = ?0.103 C (μmol/L) + 0.0376 (γ = 0.999) and the detection limit as 3.0 × l0?9 mol/L (3σ). Interferences from other metal ions were investigated and Cd2+ could be simultaneously detected in the mixture solution. The proposed method was further applied to the trace levels of Pb2+ detection in water samples with satisfactory results.  相似文献   

16.
《Analytical letters》2012,45(4):678-688
Abstract

MCM-41 was synthesized with uniform pore networks and then used to modify a carbon-paste electrode (CPE). The electrochemical behavior of rutin was investigated. Compared with the bare CPE, the MCM-41–modified CPE remarkably enhances the redox peak currents of rutin, attributed to large surface area, high sorption capacity, and specific mesopores. Based on this, a sensitive and convenient electrochemical method was developed for the analysis of rutin. The linear range is from 2.0 × 10?8 to 1.0 × 10?6 mol L?1, and the limit of detection is 1.5 × 10?8 mol L?1. Finally, this method was employed to determine rutin in traditional Chinese medicines.  相似文献   

17.
A graphene‐based electrochemical sensing platform for sensitive determination of baicalein was constructed by means of pulsed potentiostatic reduction of graphene oxide (GO) on a glassy carbon electrode (GCE). The resulting electrode (ERGO/GCE) was characterized by cyclic voltammetry (CV) and scanning electron microscopy (SEM). The electrochemical behaviors of baicalein at the ERGO/GCE were investigated in detail by CV, chronoamperometry (CA) and chronocoulometry (CC). The experimental results demonstrated that the ERGO/GCE exhibited excellent response toward the redox of baicalein as evidenced by the significant enhancement of redox peak currents (ip) and the decreased peak‐to‐peak separation (ΔEp) in comparison with a bare GCE. Under the optimum experimental conditions, the reduction peak cureent was proportioanal to the baicalein concentration in the range of 5.0 × 10‐9 ~ 5.0 × 10‐7 mol L‐1 with the detection limit of 2.0 × 10‐9 mol L‐1. The proposed method was also applied successfully to determine baicalein in spiked human blood serum samples.  相似文献   

18.
A mesoporous zirconia modified carbon paste electrode was developed for electrochemical investigations of methyl parathion (MP, Phen‐NO2). The significant increase of the peak currents and the improvement of the redox peak potential indicate that mesoporous zirconia facilitates the electronic transfer of MP. The oxidation peak current was proportional to the MP concentration in the range from 1.0×10−8 to 1.0×10−5 mol L−1 with a detection limit of 4.6×10−9 mol L−1 (S/N=3) after accumulation under open‐circuit for 210 s. The proposed method was successfully applied to the determination of MP in apple samples.  相似文献   

19.
CeO2 nanoparticles approximately 12 nm in size were synthesized and subsequently characterized by XRD, TEM and UV-vis spectroscopy. Then, a gold electrode modified with CeO2 nanoparticles was constructed and characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The modified electrode demonstrated strong catalytic effects with high stability towards electrochemical oxidation of rutin. The anodic peak currents (measured by differential pulse voltammetry) increased linearly with the concentration of rutin in the range of 5.0 × 10−7–5.0 × 10−4 mol · L−1. The detection limit (S/N = 3) was 2.0 × 10−7 mol · L−1. The relative standard deviation (RSD) of 8 successive scans was 3.7% for 5.0 × 10−6 mol · L−1 rutin. The method showed excellent sensitivity and stability, and the determination of rutin in tablets was satisfactory.  相似文献   

20.
In this paper two kinds of ionic liquids (ILs) were used for the construction of a myoglobin (Mb) electrochemical biosensor. Firstly a hydrophilic ionic liquid of 1‐ethyl‐3‐methylimidazolium tetrafluoroborate (EMIMBF4) was used as binder to prepare a carbon ionic liquid electrode (CILE), then a Nafion and hydrophobic ionic liquid of 1‐butyl‐3‐methylimidazolium hexafluorophosphate (BMIMPF6) composite film was applied on the surface of the CILE. The direct electrochemistry of Mb in the Nafion‐BMIMPF6/CILE was achieved with the cathodic and anodic peak potentials located at ?0.345 V and ?0.213 V (vs. SCE). The formal potential (E°′) was located at ?0.279 V, which was the characteristic of Mb FeIII/FeII redox couples. The electrochemical behaviors of Mb in the Nafion‐ionic liquid composite film modified CILE were carefully investigated. The Mb modified electrode showed good electrocatalytic behaviors to the reduction of trichloroacetic acid (TCA) and NaNO2. Based on the Nafion‐BMIMPF6/Mb/CILE, a new third generation reagentless biosensor was constructed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号