首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 578 毫秒
1.
This research focuses on the effect of ultrasonically-assisted drilling (UAD) on carbon fibre-reinforced plastics. High-frequency vibration was used to excite a drill bit during its standard operation. An extensive experimental study of drilling forces, temperature, chip formation, surface finish, circularity, delamination and tool wear was conducted using ∅3 mm drill and presented here. UAD showed a significant improvement in drill quality when compared to conventional drilling processes. A finite-element study was also conducted to understand the nature of drilling-force reduction in UAD.  相似文献   

2.
The presented research work, aimed at deeper understanding of vibrational process during high-frequency vibration cutting, is accomplished by treating cutting tool as an elastic structure which is characterized by several modes of natural vibrations. An approach for surface quality improvement is proposed in this paper by taking into account that quality of machined surface is related to the intensity of tool-tip (cutting edge) vibrations. It is based on the excitation of a particular higher vibration mode of a turning tool, which leads to the reduction of deleterious vibrations in the machine-tool-workpiece system through intensification of internal energy dissipation in the tool material. The combined application of numerical analysis with accurate finite element model as well as different experimental methods during investigation of the vibration turning process allowed to determine that the most favorable is the second flexural vibration mode of the tool in the direction of vertical cutting force component. This mode is excited by means of piezoelectric transducer vibrating in axial tool direction at the corresponding natural frequency, thereby enabling minimization of surface roughness and tool wear.  相似文献   

3.
This study is concerned with application of numerical–experimental approach for characterizing dynamic behavior of the developed piezoelectrically excited vibration drilling tool with the aim to identify the most effective conditions of tool vibration mode control for improved cutting efficiency. 3D finite element model of the tool was created on the basis of an elastically fixed pre-twisted cantilever (standard twist drill). The model was experimentally verified and used together with tool vibration measurements in order to reveal rich dynamic behavior of the pre-twisted structure, representing a case of parametric vibrations with axial, torsional and transverse natural vibrations accompanied by the additional dynamic effects arising due to the coupling of axial and torsional deflections ((un)twisting). Numerical results combined with extensive data from interferometric, accelerometric, dynamometric and surface roughness measurements allowed to determine critical excitation frequencies and the corresponding vibration modes, which have the largest influence on the performance metrics of the vibration drilling process. The most favorable tool excitation conditions were established: inducing the axial mode of the vibration tool itself through tailoring of driving frequency enables to minimize magnitudes of surface roughness, cutting force and torque. Research results confirm the importance of the tool mode control in enhancing the effectiveness of vibration cutting tools from the viewpoint of structural dynamics.  相似文献   

4.
A non-destructive testing method for silicon nitride bearing balls based on ultrasonic resonance spectroscopy is proposed here. Through the theoretical study of their elastic vibrations, it is possible to characterize the balls using a vibration mode that is similar to surface wave propagation. The study of the influence of C-crack defects on the resonances of Rayleigh modes is presented here. These C-cracks are typically formed by impacts between balls during finishing or handling. They are frequently found on the surface of silicon nitride bearing balls and these C-cracks decrease the rolling contact fatigue life considerably. This kind of defect is difficult to detect because the C-shaped surface crack is very small and narrow (500 μm × 5 μm), and its depth does not exceed 50 μm. The proposed methodology can both excite spheroidal vibrations in the ceramic balls and detect such vibrations over a large frequency range. In particular, high frequency vibrations are considered because these are similar to the surface waves propagating in the cortical zone of the ceramic balls and consequently they can be used to detect C-crack defects.  相似文献   

5.
The sapphire substrates are polished by traditional chemical mechanical polishing (CMP) and ultrasonic flexural vibration (UFV) assisted CMP (UFV-CMP) respectively with different pressures. UFV-CMP combines the functions of traditional CMP and ultrasonic machining (USM) and has special characteristics, which is that ultrasonic vibrations of the rotating polishing head are in both horizontal and vertical directions. The material removal rates (MRRs) and the polished surface morphology of CMP and UFV-CMP are compared. The MRR of UFV-CMP is two times larger than that of traditional CMP. The surface roughness (root mean square, RMS) of the polished sapphire substrate of UFV-CMP is 0.83 Å measured by the atomic force microscopy (AFM), which is much better than 2.12 Å obtained using the traditional CMP. And the surface flatness of UFV-CMP is 0.12 μm, which is also better than 0.23 μm of the traditional CMP. The results show that UFV-CMP is able to improve the MRR and finished surface quality of the sapphire substrates greatly. The material removal and surface polishing mechanisms of sapphire in UFV-CMP are discussed too.  相似文献   

6.
This work reports the performance of high speed steel drill bits coated with TiAlSiN nanocomposite coating at different Si contents (5.5-8.1 at.%) prepared using a four-cathode reactive pulsed direct current unbalanced magnetron sputtering system. The surface morphology of the as-deposited coatings was characterized using field emission scanning electron microscopy. The crystallographic structure, chemical composition and bonding structure were evaluated using X-ray diffraction, energy-dispersive X-ray analysis, X-ray photoelectron spectroscopy, respectively. The corrosion behavior, mechanical properties and thermal stability of TiAlSiN nanocomposite coatings were also studied using potentiodynamic polarization, nanoindentation and Raman spectroscopy, respectively. The TiAlSiN coating thickness was approximately 2.5-2.9 μm. These coatings exhibited a maximum hardness of 38 GPa at a silicon content of approximately 6.9 at.% and were stable in air up to 850 °C. For the performance evaluation, the TiAlSiN coated drills were tested under accelerated machining conditions by drilling a 12 mm thick 304 stainless steel plate. Under dry conditions the uncoated drill bits failed after drilling 50 holes, whereas, TiAlSiN coated drill bits (Si = 5.5 at.%) drilled 714 holes before failure. Results indicated that for TiAlSiN coated drill bits the tool life increased by a factor of more than 14.  相似文献   

7.
Liu Y  Chen W  Liu J  Shi S 《Ultrasonics》2011,51(5):527-531
A cylindrical standing wave ultrasonic motor using bending vibration transducer was proposed in this paper. The proposed stator contains a cylinder and a bending vibration transducer. The two combining sites between the cylinder and the transducer locate at the adjacent wave loops of bending vibration of the transducer and have a distance that equal to the half wave length of bending standing wave excited in the cylinder. Thus, the bending mode of the cylinder can be excited by the bending vibration of the transducer. Two circular cone type rotors are pressed in contact to the end rims of the teeth, and the preload between the rotors and stator is accomplished by a spring and nut system. The working principle of the proposed motor was analyzed. The motion trajectories of teeth were deduced. The stator was designed and analyzed with FEM. A prototype motor was fabricated and measured. Typical output of the prototype is no-load speed of 165 rpm and maximum torque of 0.45 N m at an exciting voltage of 200 Vrms.  相似文献   

8.
The vibration characteristics of an aluminum surface subjected to ultrasonic waves were investigated with a combination of numerical simulation and experimental testing. The wetting behavior of solder droplets on the vibrating aluminum surface was also examined. The results show that the vibration pattern of the aluminum surface is inhomogeneous. The amplitude of the aluminum surface exceeds the excitation amplitude in some zones, while the amplitude decreases nearly to zero in other zones. The distribution of the zero-amplitude zones is much less dependent on the strength of the vibration than on the location of the vibration source. The surface of the liquid solder vibrates at an ultrasonic frequency that is higher than the vibration source, and the amplitude of the liquid solder is almost twice that of the aluminum surface. The vibration of the surface of the base metal (liquid solder) correlates with the oxide film removal effect. Significant removal of the oxide film can be achieved within 2 s when the amplitude of the aluminum surface is higher than 5.4 μm or when the amplitude of the liquid solder surface is higher than 10.2 μm.  相似文献   

9.
Many brittle materials, such as single-crystal materials, amorphous materials, and ceramics, are widely used in many industries such as the energy industry, aerospace industry, and biomedical industry. In recent years, there is an increasing demand for high-precision micro-machining of these brittle materials to produce precision functional parts. Traditional ultra-precision micro-machining can lead to workpiece cracking, low machined surface quality, and reduced tool life. To reduce and further solve these problems, a new micro-machining process is needed. As one of the nontraditional machining processes, rotary ultrasonic machining is an effective method to reduce the issues generated by traditional machining processes of brittle materials. Therefore, rotary ultrasonic micro-machining (RUμM) is investigated to conduct the surface micro-machining of brittle materials. Due to the small diameter cutting tool (<500 μm) and high accuracy requirements, the impact of input parameters in the rotary ultrasonic surface micro-machining (RUSμM) process on tool deformation and cutting quality is extremely different from that in rotary ultrasonic surface machining (RUSM) with relatively large diameter cutting tool (∼10 mm). Up till now, there is still no investigation on the effects of ultrasonic vibration (UV) and input variables (such as tool rotation speed and depth of cut) on cutting force and machined surface quality in RUSμM of brittle materials. To fill this knowledge gap, rotary ultrasonic surface micro-machining of the silicon wafer (one of the most versatile brittle materials) was conducted in this study. The effects of ultrasonic vibration, tool rotation speed, and depth of cut on tool trajectory, material removal rate (MRR), cutting force, cutting surface quality, and residual stress were investigated. Results show that the ultrasonic vibration could reduce the cutting force, improve the cutting surface quality, and suppress the residual compressive stress, especially under conditions with high tool rotation speed.  相似文献   

10.
A theoretical model was suggested for qualitative evaluation of a sound pressure field in fruit tissue, as affected by ultrasonic probe dimensions and fruit properties. The classic directivity pattern of an ideal fluid model, expressed by Bessel function of the first kind, was extended to include energy dissipation of a real material. The directional characteristics of wave propagation, as influenced by transmitter frequency and diameter, and by fruit properties, were discussed. The model indicates how to select the parameters of the ultrasonic transducer (transducer diameter, frequency and excitation power) to control the magnitude and directivity of the ultrasonic waves in the fruit tissue. The suggested theoretical model represented fairly well the experimental sound wave distribution over the half-cut surface of potato and avocado (R2 > 0.862 and 0.977, respectively); the same theoretical model could not represent the sound wave distribution over a half-cut melon. Results of the study were applied in a new probe design for ultrasonic testing of whole fruit.  相似文献   

11.
12.
Shuyu L 《Ultrasonics》2005,43(5):365-373
Based on the equivalent circuit theory, the load characteristics of high power piezoelectric ultrasonic sandwich transducers are studied. Two types of loads are studied. One is liquid load as in ultrasonic cleaning, and the other is solid load as in ultrasonic drilling and machining. The effect of load and structure of the transducer on the resonance frequency of the transducer is analyzed. It is shown that the effect of load on the resonance frequency of sandwich transducers with different structures is different. For liquid load as in ultrasonic cleaning, the effect of the load on the resonance frequency of the sandwich transducer with symmetrical structure is the largest. It is the smallest for the transducer with its displacement node in the back metal cylinder. For solid load as in ultrasonic drilling and machining, the effect of the load on the resonance frequency of the sandwich transducer with its displacement node in the front metal cylinder is the largest. It is also the smallest for the transducer with its displacement node in the back metal cylinder. On the other hand, for some applications, such as ultrasonic drilling, when the lateral dimension of the tool is much less than that of the transducer, its effect on the resonance frequency of the transducer is small. The conclusions are useful in designing vibrating systems for different ultrasonic applications.  相似文献   

13.
For a non-contact ultrasonic material removal process, the control of the standoff position can be crucial to process performance; particularly where the requirement is for a standoff of the order of <20 μm. The standoff distance relative to the surface to be machined can be set by first contacting the ultrasonic tool tip with the surface and then withdrawing the tool to the required position. Determination of this contact point in a dynamic system at ultrasonic frequencies (>20 kHz) is achieved by force measurement or by detection of acoustic emissions (AE). However, where detection of distance from a surface must be determined without contact taking place, an alternative method must be sought.  相似文献   

14.
张轩  刘小振  吴思楠  傅波 《应用声学》2023,42(4):683-692
为解决传统的搅拌摩擦焊工艺存在的轴向压力过大、搅拌头易磨损、焊接表面存在缺陷等问题,设计了一种集搅拌头与夹心式纵扭超声振动换能器为一体的超声辅助搅拌摩擦焊工具头。对超声辅助搅拌摩擦焊工具头进行了模态分析与谐响应分析,确保换能器结构满足要求。应用仿真软件对超声辅助搅拌摩擦焊进行了流体场、温度场和声场仿真分析,验证了在搅拌摩擦焊过程中加入纵扭超声振动能够增强材料的软化率,提高焊接材料的塑性流动。搭建实验平台,进行了6061铝合金的超声辅助搅拌摩擦焊焊接实验。结果表明,纵扭超声的引入能够提高焊接过程中材料流动性,减小搅拌头的前进阻力和轴向压力,改善焊接表面质量。在焊头转速900 r/min、焊接速度1.4 mm/s、轴向压力2.6 kN、超声功率100 W时,焊接效果最好,能较好地应在铝合金、镁合金等焊接熔点比较低的轻金属焊接之中。  相似文献   

15.
Liu C  Djuth F  Li X  Chen R  Zhou Q  Shung KK 《Ultrasonics》2012,52(4):497-502
This paper reports the design, fabrication, and performance of miniature micromachined high frequency PMN-PT/epoxy 1-3 composite ultrasonic annular arrays. The PMN-PT single crystal 1-3 composites were made with micromachining techniques. The area of a single crystal pillar was 9 × 9 μm. The width of the kerf among pillars was ∼5 μm and the kerfs were filled with a polymer. The composite thickness was 25 μm. A six-element annular transducer of equal element area of 0.2 mm2 with 16 μm kerf widths between annuli was produced. The aperture size the array transducer is about 1.5 mm in diameter. A novel electrical interconnection strategy for high density array elements was implemented. After the transducer was attached to the electric connection board and packaged, the array transducer was tested in a pulse/echo arrangement, whereby the center frequency, bandwidth, two-way insertion loss (IL), and cross talk between adjacent elements were measured for each annulus. The center frequency was 50 MHz and −6 dB bandwidth was 90%. The average insertion loss was 19.5 dB at 50 MHz and the crosstalk between adjacent elements was about −35 dB. The micromachining techniques described in this paper are promising for the fabrication of other types of high frequency transducers, e.g. 1D and 2D arrays.  相似文献   

16.
In this paper, the effects of piston scuffing fault on engine performance and vibrations are investigated. A procedure based on vibration analysis is also presented to identify piston scuffing fault. To this end, an internal combustion (IC) engine ran under a specific test procedure. The engine parameters and vibration signals were measured during the experiments. To produce piston scuffing fault, three-body abrasive wear mechanism was employed. The experimental results showed that piston scuffing fault caused the engine performance to reduce significantly. The vibration signals were analyzed in time-domain, frequency-domain and time–frequency domain. Continuous wavelet transform (CWT) was used to obtain time–frequency representations. “dmey” wavelet was selected as the optimum wavelet type for this research among different wavelet types using the three criteria of energy, Shannon entropy and energy to Shannon entropy ratio. The results of CWT analysis by “dmey” wavelet showed that piston scuffing fault excited the frequency band of 2.4–4.7 kHz in which the frequency of 3.7 kHz was affected more. Finally, seven different features were extracted from the engine vibration signals related to the frequency band of 2.4–4.7 kHz. The results indicated that maximum, mean, RMS, skewness, kurtosis and impulse factor of the engine vibration related to the found frequency band increased significantly due to piston scuffing fault. The obtained results showed that the proposed method identified piston scuffing fault and discovered the vibration characteristics of this fault like frequency band. The results also demonstrated the possibility of using engine vibrations in piston scuffing fault identification.  相似文献   

17.
赵甜甜  林书玉  段祎林 《物理学报》2018,67(22):224207-224207
利用声子晶体的带隙理论以及耦合振动理论对大尺寸矩形超声塑料焊接工具的耦合振动进行了研究.在实际工程应用中,大尺寸工具的横向振动将严重导致工具头辐射面位移不均匀,影响系统的焊接质量及工作效率.为提高其工作效率,改善工具头辐射面位移的均匀程度,利用类声子晶体结构对大尺寸超声塑料焊接工具的横向振动进行抑制,分析并得出了类声子晶体结构的横向振动带隙,同时分析了工具头横向振动未抑制与抑制后其辐射面位移的大小与均匀程度.研究表明,通过合理设计类声子晶体的结构及尺寸,可以有效抑制超声塑料焊接工具的横向振动.不但改善了焊接工具辐射面纵向振动位移的均匀程度,而且提高了焊接工具的纵向振动位移幅度.  相似文献   

18.
Spectral characteristics of laser-generated acoustic waves in an InGaN/GaN superlattice structure are studied at room temperature. Acoustic vibrations in the structure are excited with a femtosecond laser pulse and detected via transmission of a delayed probe pulse. Seven acoustic modes of the superlattice are detected, with frequencies spanning a range from 0.36 to 2.5 THz. Acoustic waves up to ∼2 THz in frequency are not significantly attenuated within the transducer which indicates excellent interface quality of the superlattice. The findings hold promise for broadband THz acoustic spectroscopy.  相似文献   

19.
An ultrasonic nanocrystal surface modification (UNSM) technique, at 3 different vibration strike numbers (34,000 times/mm2, 45,000 times/mm2, 68,000 times/mm2) was used to modify the surface structure and properties of S45C. These three process conditions respectively produced 2 μm, 12 μm and 30 μm nanocrystal layers. UNSM technique improves the following mechanical properties: microhardness, surface roughness, and compressive residual stress. Also, fatigue life increased with the vibration strike number. UNSM C3 (with the vibration strike number of 68,000 times/mm2) has improved the fatigue strength by as much as 33% for S45C. Optical microscope pictures show that cracks usually initiate from intergranular microcracks on the surface and then extend along the tip traces of UNSM which are considered as process defects. A simple math model (tearing adhesive plaster model) has been made to analyze the initiation and growth of cracks. Though most of the cracks initiate at the surface of specimens, surface nanocrystal layers can help to retard crack initiation. In S45C, the efficiency of crack resistance is more than 48%.the vibration strike number  相似文献   

20.
A novel distributed fiber-optic vibration sensing system is proposed and demonstrated. By employing a ring Mach-Zehnder interferometer (MZI) structure as the sensing section, both position and frequency can be determined by combining two phase signals from the ring configuration. A spatial resolution better than 38 m is successfully verified in a 1.01 km prototype system of single vibration. Moreover, the feasibility of separately locating multiple vibrations is also theoretically simulated and experimentally investigated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号