首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
A new technique for measuring CO(2) concentration in air samples, based on mass spectrometry, is described as an alternative to the common gas chromatographic method. Using a dual inlet isotope ratio mass spectrometer (IRMS), the ratio of the abundances of the m/z peaks 44 and 28 is determined. The precision of measurements (standard deviation <3 ppmv) is generally as good as the analysis with gas chromatography for small air samples (<1 ml STP of air). A major advantage of this new method is the possibility of parallel elemental and isotopic measurements of many air components. The technique is further improved by new wide mass range mass spectrometers allowing simultaneous intensity measurements of several m/z values between 28 and 44, resulting in an uncertainty of <0.5 ppm. The precision is somewhat limited by the production of N(2)O and NO(2) from N(2) and O(2) in the ion source, which accounts for about half of the signal strength at m/z 44. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

2.
We have developed a new inlet system for a gas sample isotope ratio mass spectrometer (IRMS). It is based on the well-known open split design from the gas chromatography/mass spectrometry (GC/MS) system due to its simplicity. The advantages over the conventional double inlet system with the metal bellows design include an improved reproducibility mainly due to a highly controllable pressure and temperature adjustment, a markedly lowered memory effect due to an uninterrupted gas flow through the ion source which limits adsorption/desorption processes on surfaces, and a single inlet capillary circumventing problems of asymmetrical behavior of sample and reference inlet paths. Furthermore, sample consumption is of the same order as for conventional measurements (i.e. about 0.4 mmol per hour), of which however only 2 &mgr;mol/h is used for the actual isotope ratio determination since the major gas amount acts as a gas flow seal against the atmosphere, corresponding to a 100-200 fold overkill. This may be improved in future systems. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

3.
A double-focusing mass spectrometer (MS) equipped with a superconducting-tunnel-junction (STJ) detector has been applied to measure relative ionization cross-sections for the production of ions that are accompanied by different ion species with the same mass-to-charge (m/z) value. The STJ detector fabricated for this study enables kinetic energy (E) measurement of incoming individual ions at a counting rate of up to approximately 100 k ions/s and an energy resolution (DeltaE/E) of 15%. Both high counting rate and high-energy resolution are necessary to independently determine both m and z and not the m/z value only in ion-counting MS experiments. Ions such as (14)N(2) (2+) and (14)N(+) with the same m/z value can be clearly discriminated using a kinetic-energy-sensitive MS. This fine discrimination capability allows direct determination of relative ionization cross-sections of the homonuclear diatomic ions (14)N(2) (2+)/(14)N(2) (+) and (16)O(2) (2+)/(16)O(2) (+), which are difficult to measure due to the strong interference by the signals of their dissociated atomic ions with noticeably large ionization cross-sections. The new instrument requires no low-abundance heteronuclear diatomic molecules of the forms (14)N(15)N or (16)O(17)O to carry out ionization studies and thus, is expected to be useful in fields such as atmospheric science, interstellar science, or plasma physics.  相似文献   

4.
Two alternative approaches for the calibration of the intramolecular nitrogen isotope distribution in nitrous oxide using isotope ratio mass spectrometry have yielded a difference in the 15N site preference (defined as the difference between the delta15N of the central and end position nitrogen in NNO) of tropospheric N2O of almost 30 per thousand. One approach is based on adding small amounts of labeled 15N2O to the N2O reference gas and tracking the subsequent changes in m/z 30, 31, 44, 45 and 46, and this yields a 15N site preference of 46.3 +/- 1.4 per thousand for tropospheric N2O. The other involves the synthesis of N2O by thermal decomposition of isotopically characterized ammonium nitrate and yields a 15N site preference of 18.7 +/- 2.2 per thousand for tropospheric N2O. Both approaches neglect to fully account for isotope effects associated with the formation of NO+ fragment ions from the different isotopic species of N2O in the ion source of a mass spectrometer. These effects vary with conditions in the ion source and make it impossible to reproduce a calibration based on the addition of isotopically enriched N2O on mass spectrometers with different ion source configurations. These effects have a much smaller impact on the comparison of a laboratory reference gas with N2O synthesized from isotopically characterized ammonium nitrate. This second approach was successfully replicated and leads us to advocate the acceptance of the site preference value 18.7 +/- 2.2 per thousand for tropospheric N2O as the provisional community standard until further independent calibrations are developed and validated. We present a technique for evaluating the isotope effects associated with fragment ion formation and revised equations for converting ion signal ratios into isotopomer ratios.  相似文献   

5.
An ion mobility spectrometer that can easily be installed as an intermediate component between a commercial triple-quadrupole mass spectrometer and its original atmospheric pressure ionization (API) sources was developed. The curtain gas from the mass spectrometer is also used as the ion mobility spectrometer drift gas. The design of the ion mobility spectrometer allows reasonably fast installation (about 1 h), and thus the ion mobility spectrometer can be considered as an accessory of the mass spectrometer. The ion mobility spectrometer module can also be used as an independently operated device when equipped with a Faraday cup detector. The drift tube of the ion mobility spectrometer module consists of inlet, desolvation, drift, and extraction regions. The desolvation, drift and extraction regions are separated by ion gates. The inlet region has the shape of a stainless steel cup equipped with a small orifice. Ion mobility spectrometer drift gas is introduced through a curtain gas line from an original flange of the mass spectrometer. After passing through the drift tube, the drift gas serves as a curtain gas for the ion-sampling orifice of the ion mobility spectrometer before entering the ion source. Counterflow of the drift gas improves evaporation of the solvent from the electrosprayed sample. Drift gas is pumped away from the ion source through the original exhaust orifice of the ion source. Initial characterization of the ion mobility spectrometer device includes determination of resolving power values for a selected set of test compounds, separation of a simple mixture, and comparison of the sensitivity of the electrospray ionization ion mobility spectrometry/mass spectrometry (ESI-IMS/MS) mode with that of the ESI-MS mode. A resolving power of 80 was measured for 2,6-di-tert-butylpyridine in a 333 V/cm drift field at room temperature and with a 0.2 ms ion gate opening time. The resolving power was shown to be dependent on drift gas flow rate for all studied ion gate opening times. Resolving power improved as the drift gas flow increased, e.g. at a 0.5 ms gate opening time, a resolving power of 31 was obtained with a 0.65 L/min flow rate and 47 with a 1.3 L/min flow rate for tetrabutylammonium iodide. The measured limits of detection with ESI-MS and with ESI-IMS/MS modes were similar, demonstrating that signal losses in the IMS device are minimal when it is operated in a continuous flow mode. Based on these preliminary results, the IMS/MS instrument is anticipated to have potential for fast screening analysis that can be applied, for example, in environmental and drug analysis.  相似文献   

6.
The fragment ion formation characteristics of the radical anions generated from hexahydro-1,3,5-trinitrotriazine (RDX) and its three nitroso metabolites were studied using GC/MS with negative chemical ionization (NCI) to understand the fragmentation mechanisms responsible for the formation of the most abundant ions observed in their NCI mass spectra. Ab initio and density functional theory calculations were used to calculate relative free energies for different fragment ion structures suggested by the m/z values of the most abundant ions observed in the NCI mass spectra. The NCI mass spectra of the four nitramines are dominated by ions formed by the cleavage of nitrogen-nitrogen and carbon-nitrogen bonds in the atrazine ring. The most abundant anions in the NCI mass spectra of these nitramines have the general formulas C(2)H(4)N(3)O (m/z 86) and C(2)H(4)N(3)O(2) (m/z 102). The analyses of isotope-labeled standards indicate that these two ions are formed by neutral losses that include two exocylic nitrogens and one atrazine ring nitrogen. Our calculations and observations of the nitramine mass spectra suggest that the m/z 86 and m/z 102 ions are formed from either the (M--NO)(-) or (M--NO(2))(-) fragment anions by a single fragmentation reaction producing neutral losses of CH(2)N(2)O or CH(2)N(2)O(2) rather than a set of sequential reactions involving neutral losses of HNO(2) or HNO and HCN.  相似文献   

7.
For the first time, we observed a stable and intense ion (m/z 376) of the oxygenated water cluster ion ((H(2)O)(20)O(+)) produced from simply spraying an aqueous solution of iron nanoparticles (Fe NPs) into an electrospray mass spectrometry (ESI-MS) system. Tandem mass spectrometric (MS/MS and MS/MS/MS) results were applied to identify the assignments of the fragment ions of m/z 376 in order to explore the possible structures of this cluster ion. The possible structures of the (H(2)O)(20)O(+) ions are proposed as pentagonal dodecahedron water clathrate cages from the results of tandem mass spectrometry since eliminations of five water molecules were frequently observed in the MS/MS results for many subsequent fragment ions of m/z 376. The formation of this oxygenated water cluster ion ((H(2)O)(20)O(+)) in ESI-MS is attributed to the high surface reactivity and surface energy of Fe NPs during ESI processes (under high temperature and high voltage (5 kV) of ESI spray environment). We believe that the observation of self-assembly formation of oxygenated water clusters is an important issue in nanoscience as well as in the fields of water clusters.  相似文献   

8.
Inductively coupled plasma quadrupole mass spectrometry (ICP-QMS) was used for the accurate determination of copper in coal fly ash samples in the presence of excess titanium, using the reaction of Cu(+) ions with NH(3) in the cell. The method eliminated the effect of polyatomic isobaric interferences at m/z 63 and 65 caused by the formation of (47)Ti(16)O(+), (49)Ti(16)O(+) and (47)Ti(18)O(+) on (63)Cu(+) and (65)Cu(+) by detecting Cu(+) as the product cluster ion Cu(NH(3))(2)(+). As the signal of (63)Cu(NH(3))(2)(+) overlapped with that of (97)Mo(+) which existed in the samples, (65)Cu(NH(3))(2)(+) was detected at m/z 99. The effect of the operating conditions of DRC system was studied in order to obtain the best signal to noise ratio for Cu(NH(3))(2)(+) at m/z 99. The formation of Cu(NH(3))(2)(+) was through the clustering reaction Cu(+)+2NH(3)-->Cu(NH(3))(2)(+) which resulted in the separation of analyte from the interfering oxide. The detection limit for Cu(NH(3))(2)(+) was 0.015 ng mL(-1) as Cu. The method was applied to the determination of copper in NIST SRM 1633a and 1633b coal fly ash reference materials. The precision between sample replicates was better than 2.0% and the analysis results were in good agreement with the certified values.  相似文献   

9.
Selected ion flow tube mass spectrometry, (SIFT-MS), involves the partial conversion of mass-selected precursor ions to product ions in their reactions with the trace gases in an air sample that is introduced into helium carrier gas in a flow tube. The precursor and product ions are then detected and counted by a downstream quadrupole mass spectrometer. Quantification of particular trace gases is thus achieved from the ratio of the total count rate of the product ions to that for the precursor ions. However, it is important to appreciate that in this ion chemistry the light precursor ions (usually H3O+ ions) are invariably converted to heavier product ions. Hence, the product ions diffuse to the flow tube walls more slowly and thus they are more efficiently transported to the downstream mass spectrometer sampling orifice. This phenomenon we refer to as diffusion enhancement. Further, it is a well-known fact that discrimination can occur against ions of large mass-to-charge ratio, (m/z), in quadrupole mass spectrometers. If not accounted for, diffusion enhancement usually results in erroneously high trace gas concentrations and mass discrimination results in erroneously low concentrations. In this experimental investigation, we show how both these counteracting effects can be accounted for to increase the accuracy of SIFT-MS quantification. This is achieved by relating the currents of ions of various m/z that arrive at the downstream mass spectrometer sampling orifice disc to their count rates at the ion detector after mass analysis. Thus, both diffusion enhancement and mass discrimination are parameterized as a function of m/z and these are combined to provide an overall discrimination factor for the particular analytical instrument.  相似文献   

10.
Upon hexanal-modification in the presence of NaCNBH(3), the oxidized B chain of insulin becomes mono- and further dialkylated on both the N-terminal and Lys(29) residues. A pseudo-MS(3) study was performed with a triple-quadrupole mass spectrometer on the different modified lysine-containing species to gain further insights into the characteristic fragmentation pattern. These fragmentations, in good agreement with true MS(3) measurements obtained using an ion trap mass spectrometer, highlighted characteristic monoalkylated lysine (immonium-NH(3)) and protonated modified caprolactam ions at m/z 168 and 213, respectively. In contrast, no fragment ion derived from a modified lysine residue (immonium or caprolactam) was observed when dialkylation occurs on Lys(29). However, a fragment ion corresponding to a protonated dihexylamine was observed at m/z 186. This loss, characteristic of dialkylated lysine fragmentation, was also observed upon dialkylation of N(alpha)-acetyllysine with either hexanal or pentanal. On the other hand, acetylation and malondialdehyde-modification of the N(alpha)-acetyllysine side chain led mainly to the corresponding modified (immonium-NH(3)) fragment ions at m/z 126 and 138, respectively. Finally, it was demonstrated that precursor ion scanning for both m/z 168 and 213 ions led to specific and sensitive identification of peptides containing hexanal-modified lysine residues within an unfractionated tryptic digest of hexanal-modified apomyoglobin. Thus, Lys(42), Lys(45), Lys(62), Lys(63), Lys(77), Lys(87), Lys(96), Lys(98), Lys(145) and Lys(147) were found to be modified upon reaction with hexanal.  相似文献   

11.
We have developed a new method for the on-line quantification of deuterium in water vapour. We call this method flowing afterglow mass spectrometry (FA-MS). A swarm of H3O+ precursor ions is created in flowing helium carrier gas by a microwave discharge. These precursor ions react with the H2O, HDO, H2(17)O and H2(18)O molecules in a water vapour sample that is introduced into the carrier gas/H3O+ ion swarm. The hydrated ions, H3O+.(H2O)3 at m/z 73, and their isotopic variant ions H8DO4(+) and H9(17)OO(3)(+) at m/z 74 and H9(18)OO(3)(+) at m/z 75, are thus formed. By adopting the known fractional abundance of 18O in water vapour, and accounting for the contribution of the isotopic ions H9(17)OO(3)(+) to the ion signal at m/z 74, a measurement of the 74/75 ion signal ratio under equilibrium conditions provides the fractional deuterium abundance in the water vapour sample. Using this technique, the deuterium abundance in the water vapour present in single exhalations of breath can be determined. Thus, from the temporal variations of breath deuterium following the ingestion of a known quantity of D(2)O, we show that total body water can be determined non-invasively and the kinetics of water flow around the body can be tracked.  相似文献   

12.
In spite of extensive efforts, even the most experienced laboratories dealing with isotopic measurements of atmospheric CO2 still suffer from poor inter-laboratory consistency. One of the complicating factors of these isotope measurements is the presence of N2O, giving rise to mass overlap in the isotope ratio mass spectrometer (IRMS). The aim of the experiment reported here has been twofold: first, the re-establishment of the correction for 'mechanical' interference of N2O in the IRMS, along with its variability and drift, and the best way to quantitatively determine the correction factors. Second, an investigation into secondary effects, i.e. the influence of N2O admitted with the CO2 sample on the "cross contamination" between sample and (pure CO2) working gas. To make the suspected effects better detectable, isotopically enriched CO2 gas with different concentrations of N2O has been measured for the first time. No evidence of secondary effects was observed, from which we conclude that N2O is not a major player in the inter-laboratory consistency problems. Still, we also found that the determination of the 'mechanical' N2O correction needs to be very carefully determined for each individual IRMS, and should be periodically re-determined. We show that the determination of the correction should be performed using CO2/N2O mixtures with concentration ratios around that of the atmosphere, as the extrapolation from pure gas end member behaviour will give erroneous results due to non-linearities. For our IRMS, a VG SIRA series II, we find a correction of 0.23 per thousand for delta45CO2 and 0.30 per thousand for delta46CO2 of atmospheric samples, (with 0.85 per thousand mixing ratio). This implies that the relative ionisation efficiency (E) value associated with this machine is 0.75.  相似文献   

13.
The unimolecular dissociation reactions of the methylhydrazine (MH) and tetramethylhydrazine (TMH) radical cations have been investigated using tandem mass spectrometry and threshold photoelectron photoion coincidence spectroscopy in the photon energy ranges 9.60-31.95 eV (for the MH ion) and 7.74-29.94 eV (for the TMH ion). Methylhydrazine ions (CH3NHNH2(+*)) have three low-energy dissociation channels: hydrogen atom loss to form CH2NHNH2(+) (m/z 45), loss of a methyl radical to form NHNH2(+) (m/z 31), and loss of methane to form the fragment ion m/z 30, N2H2(+*). Tetramethylhydrazine ions only exhibit two dissociation reactions near threshold: that of methyl radical loss to form (CH3)2NNCH3(+) (m/z 73) and of methane loss to form the fragment ion m/z 72 with the empirical formula C3H8N2(+*). The experimental breakdown curves were modeled with Rice-Ramsperger-Kassel-Marcus theory, and it was found that, particularly for methyl radical loss, variational transition state theory was needed to obtain satisfactory fits to the data. The 0 K enthalpies of formation (delta(f)H0) for all fragment ions (m/z 73, m/z 72, m/z 45, m/z 31, and m/z 30) have been determined from the 0 K activation energies (E0) obtained from the fitting procedure: delta(f)H0[(CH3)2NNCH3(+)] = 833 +/- 5 kJ mol(-1), delta(f)H0 [C3H8N2(+*)] = 1064 +/- 5 kJ mol(-1), delta(f)H0[CH2NHNH2(+)] = 862 +/- 5 kJ mol(-1), delta(f)H0[NHNH2(+)] = 959 +/- 5 kJ mol(-1), and delta(f)H0[N2H2(+*)] = 1155 +/- 5 kJ mol(-1). The breakdown curves have been measured from threshold up to h nu approximately 32 eV for both hydrazine ions. As the photon energy increases, other dissociation products are observed and their appearance energies are reported.  相似文献   

14.
Lopes NP  Stark CB  Gates PJ  Staunton J 《The Analyst》2002,127(4):503-506
Monensin A was studied by electrospray ionisation sequential mass spectrometry (ESI-MSn) and all fragments were confirmed by accurate-mass measurements. Analyses were performed on both a quadrupole time-of-flight (Q-tof) and a Fourier-transform ion cyclotron resonance (FT-ICR) mass spectrometer. MSn analysis shows that depending on sample preparation the ion at m/z 671 consists of two different ions with the same accurate-mass. It is either the monensin protonated parent ion or a different ion structure derived from the loss of water from the water adduct of monensin. Both ions show different fragmentation patterns. Major fragment ions from the protonated parent ion were produced by Grob-Wharton type fragmentations in addition to various simple neutral losses. The fragmentation pathways of the two different m/z 671 ions are proposed.  相似文献   

15.
建立了尿样中8-羟基脱氧鸟嘌呤的HPLC-MS测定方法.尿样中的8-羟基脱氧鸟嘌呤采用WCX固相萃取小柱预富集后,以0.5%甲酸-甲醇洗脱,吹干后用0.5 mL流动相溶解剩余物上机测定.采用分子的二级碎片,方法在5.0~500.0 μg/L范围内呈良好线性关系,相关系数r=0.999 4,检出限(S/N=3)为0.50...  相似文献   

16.
We describe a rapid in situ method for detecting agrochemicals on the surface or in the tissue of fruit using a portable mass spectrometer equipped with an ambient ionization source. Two such ionization methods, low temperature plasma (LTP) and paper spray (PS), were employed in experiments performed at a local grocery store. LTP was used to detect diphenylamine (DPA) directly from the skin of apples in the store and those treated after harvest with DPA were recognized by MS and MS/MS. These data therefore allowed ready distinction between organic and non-organic apples. DPA was also found within the internal tissue of purchased apples and its distribution was mapped using LTP. Similarly, thiabendazole residues were detected on the skin of treated oranges in a grocery store experiment in which paper spray was performed by wiping the orange surface with a moist commercial lens wipe and then applying a high voltage to ionize the chemicals directly from the wipe. The handheld mass spectrometer used in these measurements is capable of performing several stages of tandem mass spectrometry (up to MS(5)); the compounds on the fruit were identified by their MS/MS fragmentation patterns. Protonated DPA (m/z 170) produced a characteristic MS(2) fragment ion at m/z 92, while thiabendazole was identified by MS(3) using precursor to fragment ion transitions m/z 202 →m/z 175 →m/z 131. These particular examples exemplify the power of in situ analysis of complex samples using ambient ionization and handheld mass spectrometers.  相似文献   

17.
It is well known that N(2) in the ion source of a mass spectrometer interferes with the CO background during the δ(18)O measurement of carbon monoxide. A similar problem arises with the high-temperature conversion (HTC) analysis of nitrogenous O-bearing samples (e.g. nitrates and keratins) to CO for δ(18)O measurement, where the sample introduces a significant N(2) peak before the CO peak, making determination of accurate oxygen isotope ratios difficult. Although using a gas chromatography (GC) column longer than that commonly provided by manufacturers (0.6 m) can improve the efficiency of separation of CO and N(2) and using a valve to divert nitrogen and prevent it from entering the ion source of a mass spectrometer improved measurement results, biased δ(18)O values could still be obtained. A careful evaluation of the performance of the GC separation column was carried out. With optimal GC columns, the δ(18)O reproducibility of human hair keratins and other keratin materials was better than ± 0.15 ‰ (n=5; for the internal analytical reproducibility), and better than ± 0.10 ‰ (n=4; for the external analytical reproducibility).  相似文献   

18.
Acrolein (C(3)H(4)O) and 1-butene (C(4)H(8)) can both be individually detected by proton transfer chemical ionization mass spectrometry (CI-MS). However, because these compounds are isobaric, mixtures of these two compounds cannot be resolved since both compounds react with H(3)O(+) via a proton-transfer reaction to form a protonated molecule that is detected at a nominal mass-to-charge ratio of 57 (m/z 57). While both compounds react with H(3)O(+) only acrolein reacts to any significant extent with H(3)O(+)(H(2)O). Recognizing that the electrical potential applied to a drift tube reaction mass spectrometer provides a simple and effective means for varying the relative intensity of the H(3)O(+) and H(3)O(+)(H(2)O) reactant ions we have developed a method whereby we make use of this reactivity difference to resolve mixtures of these two compounds. We demonstrate a technique where the individual contributions of acrolein and 1-butene within a mixture can be quantitatively resolved by systematically changing the reagent ion from H(3)O(+) to H(3)O(+)(H(2)O) through control of the electric potential applied to the drift tube reaction region of a proton transfer reaction mass spectrometer.  相似文献   

19.
曹京宜  付大海  张峰  梁栋 《色谱》2000,18(5):390-393
 用裂解同时烷基化气相色谱-质谱联用技术(SPM-GC-MS)对不同类型的醇酸树脂进行分析研究,将衍生化试剂四甲基氢氧化胺与样品同时裂解,经高效毛细管气相色谱分离,质谱鉴定,可区分醇酸树脂中的多元醇、多元酸、植物油类型,由此对改性醇酸树脂作结构鉴定。与直接裂解-气相色谱-质谱联用技术比较,具有样品前处理快速、简单,用量少,灵敏度高,定性准确,谱图直观等特点。  相似文献   

20.
裂解气中NO,AsH_3,COS等杂质的色/质联用测定研究   总被引:2,自引:0,他引:2  
郑永杰  李英杰  张维冰  吕自立 《色谱》2001,19(4):338-340
 以气相色谱 /质谱 (GC/MS)的选择离子监测 (SIM )测定方式对裂解气中的一氧化氮、砷化氢、羰基硫、硫醚、硫醇等杂质进行了测定。针对一氧化碳、二氧化碳、乙烷、乙烯及氮气对一氧化氮测定的干扰 ,分别采取色谱分离和扣除响应的方法对其予以排除。考察了裂解工艺气物流对所选择离子的测定的干扰情况。对实际工艺气中的上述杂质进行了测定 ,结果一氧化氮的检出限为 10 0nL/L。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号