首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
The adsorption behavior and differential pulse cathodic adsorptive stripping voltammetry of the pesticide Chlorpyrifos (CP) were investigated at the hanging mercury drop electrode (HMDE). The pesticide was accumulated at the HMDE and a well-defined stripping peak was obtained at –1.2 V vs Ag/AgCl electrode at pH 7.50. A voltammetric procedure was developed for the trace determination of Chlorpyrifos using differential pulse cathodic adsorptive stripping voltammetry (DP-CASV). The optimum working conditions for the determination of the compound were established. The peak current was linear over the concentration range 9.90 × 10–8– 5.96 × 10–7 mol/L of Chlorpyrifos. The influence of diverse ions and some other pesticides was investigated. The analysis of Chlorpyrifos in commercial formulations and treated waste water was carried out satisfactorily  相似文献   

2.
The simple, fast and highly sensitive anodic stripping voltammetric detection of As(III) at a gold (Au) nanoparticle‐modified glassy carbon (GC) (nano‐Au/GC) electrode in HCl solution was extensively studied. The Au nanoparticles were electrodeposited onto GC electrode using chronocoulometric technique via a potential step from 1.1 to 0 V vs. Ag|AgCl|NaCl (sat.) in 0.5 M H2SO4 containing Na[AuCl4] in the presence of KI, KBr, Na2S and cysteine additives. Surfaces of the resulting nano‐Au/GC electrodes were characterized with cyclic voltammetry. The performances of the nano‐Au/GC electrodes, which were prepared using different concentrations of Na[AuCl4] (0.05–0.5 mM) and KI additive (0.01–1.0 mM) at various deposition times (10–30 s), for the voltammetric detection of As(III) were examined. After the optimization, a high sensitivity of 0.32 mA cm?2 μM?1 and detection limit of 0.024 μM (1.8 ppb) were obtained using linear sweep voltammetry.  相似文献   

3.
A novel voltammetric method was successfully applied for the determination of an anticholinergic drug, oxybutynin hydrochloride (OXB). The method is concerned with electrooxidation of the drug on the surface of pencil graphite electrode (PGE). In order to enhance the electrode sensitivity and peak current, the electrode was coated with gold nanoparticles (Au-NPs) via electrochemical deposition using cyclic voltammetry from gold salt solution. The surface of Au-NPs modified PGE has been characterized using scanning electron microscopy and X-ray photoelectron spectroscopy. Various experimental variables were studied and optimized to enhance the sensor's response towards OXB. Quantitative determination of the drug was achieved in phosphate buffer pH 7.5 using differential pulse voltammetry by scanning the potential over range of 0.00 to 2.20 V with scan rate of 40 mV s−1. Validation of the method was achieved according to ICH guidelines. The method was found to be linear over concentration range (2.0×10−7–1.0×10−6 M). The suggested sensor was efficiently developed for the quantitative determination of OXB in pure form, pharmaceutical dosage form and spiked plasma samples.  相似文献   

4.
The surface of a gold disk electrode, for the first time, was modified with a self-assembled monolayer of a synthesized compound, ethyl [(methythio)carbonothioyl] glycinate (ECTG), for construction of an electrode sensitive to riboflavin (vitamin B2). The electrochemical properties of the monolayer assembled on the gold disk were investigated by cyclic voltammetry and electrochemical impedance spectroscopy. Under the optimized conditions, the voltammetric peak currents resulting from vitamin B2 (VB2) species were linear for VB2 concentrations in the range from 10–6 to 10–2 M. The effect of pH, type of buffer solution and scan rate on the response of the modified electrode was studied. The constructed electrochemical sensor responses very well to VB2 in the presence of most common vitamins. Finally, the performance of the Au–ECTG modified electrode was successfully tested for electrochemical detection of VB2 in a pharmaceutical sample.  相似文献   

5.
《Electroanalysis》2006,18(23):2314-2323
Some dithiophosphonate derivatives were synthesized and the electrochemical reduction mechanism was investigated by cyclic voltammetry (CV), square wave voltammetry (SWV) and chronoamperometry (CA) in 0.1 M tetrabutylammoniumtetrafluoroborate (TBATFB) in acetonitrile at platinum (Pt) and gold (Au) electrodes. Dithiophosphonates showed a cyclic voltammetric reduction peak at about ?1.1 V at Pt and ?1.3 V at Au electrode (vs. Ag/Ag+) in this media. It was also shown that dithiophosphonates can be determined quantitatively in acetonitrile using a calibration graph. The number of electrons transferred were calculated as 2 using ferrocene as a reference compound at the UME electrode. Mechanism of dithiophosphonates was also examined on Pt and Au electrodes and electrochemical reduction of dithiophosphonates seems to follow an EC mechanism with an irreversible electron transfer step. The reaction product in the bulk electrolysis experiment was isolated and identified using proton‐coupled P‐31 NMR, 13C‐NMR and IR spectroscopy. The adsorption tests for dithiophosphonates were revealed that no strong or weak adsorption phenomena exist on both Pt and Au electrodes. Simulation curves were acquired by DigiSim 3.03 version to investigate the reduction mechanism and to estimate the kinetic parameters for electrochemical and chemical steps.  相似文献   

6.
The presence of toxic acrylamide in a wide range of food products such as potato crisps, French fries or bread has been confirmed by Swedish scientists from Stockholm University. The neurotoxicity and possible carcinogenicity of this compound and its metabolites compel us to control them by quantitative and qualitative assays. Exposing acrylamide to pH extremes results in its hydrolysis to acrylic acid or its salt. In this work, we present the use of gold electrodes coated with self-assembled monolayers (SAMs) containing tetralactam molecules and its precursor as active elements for voltammetric detection of acrylic acid in water solution. The host molecules have been immobilised on the electrode surface by covalent Au–S bond or by embedment method into the thiol layer via hydrophobic and van der Waals interactions. Interactions with analytes were confirmed by Osteryoung square-wave voltammetry.  相似文献   

7.
Polythymine oligonucleotide (PTO)‐modified gold electrode (PTO/Au) was developed for selective and sensitive Hg2+ detection in aqueous solutions. This modified electrode was prepared by self‐assembly of thiolated polythymine oligonucleotide (5′‐SH‐T15‐3′) on the gold electrode via Au? S bonds, and then the surface was passivated with 1‐mercaptohexanol solution. The proposed electrode utilizes the specific binding interactions between Hg2+ and thymine to selectively capture Hg2+, thereby reducing the interference from coexistent ions. After exchanging the medium, electrochemical reduction at ?0.2 V for 60 s, voltammetric determination was performed by differential pulse voltammetry using 10 mM HEPES; pH 7.2, 1 M NaClO4 as supporting electrolyte. This electrode showed increasing voltammetric response in the range of 0.21 nM Hg2+, with a relative standard deviation of 5.32% and a practical detection limit of 60 pM. Compared with the conventional stripping approach, the modified electrode exhibits good sensitivity and selectivity, and is expected to be a new type of green electrode.  相似文献   

8.
We report the fabrication and electrochemical response of a gold nanoband electrode located at the bottom of a glass/epoxy nanotrench, hereafter referred to as a gold nanotrench electrode. Gold nanotrench electrodes of 12.5 and 40 nm in width with various depths from a few tens of nanometers to approximately 4 μm are fabricated and further characterized by cyclic voltammetry. The fabrication of a Au nanotrench electrode follows a simple electrochemical etching process in which a small AC signal is applied to an inlaid Au nanoband electrode submersed in a NaCl solution. The voltammetric behavior of a Au nanotrench electrode is characterized by a quasi-steady-state response at lower scan rates (e.g., <1 V/s for a 12.5-nm-wide electrode). We present an analytical expression for the quasi-steady-state diffusion-limited current of the nanotrench electrode based upon the analysis of the mass-transport resistance. Finite-element simulation of steady-state and transient voltammetric responses of the nanotrench electrodes provides additional insights for the analytical model. Peak-shaped transient voltammetric responses were observed at scan rates as low as 5 V/s for both inlaid and nanotrench electrodes. This result may suggest that the exposed area of the nanoband electrode is much greater than that expected from the fabrication of the inlaid bands. However, the extent to which this is seen is greatly decreased in the nanotrench electrode by a smoothing effect during etching. Our results confirm previous reports of excess overhanging metal and delamination crack contributing significantly to the shape and magnitude of the voltammetric response.  相似文献   

9.
The adsorptive stripping voltammetry of telmisartan was investigated with a hanging mercury drop electrode. This compound produced a catalytic hydrogen wave at ?1.5 V in Britton Robinson buffer of pH 10.38, and the peak current increased with adsorptive accumulation at the electrode. Adsorptive stripping voltammetry with the catalytic hydrogen wave could provide a sensitive novel method for the determination of telmisartan. Various chemical and instrumental parameters affecting the monitored electroanalytical response were investigated and optimized for telmisartan determination. Under these optimized conditions the square-wave adsorptive stripping voltammetric (SW-AdSV) peak current showed a linear dependence on drug concentration over the range 0.05–3.00 μg/mL (1 × 10?7?6 × 10?6 M) (r = 0.999) with accumulation for 120 s at ?1.0 V vs. Ag/AgCl. The proposed electrochemical procedure was successfully applied for the determination of telmisartan in pharmaceutical tablets and human plasma. The results of the developed SW-AdSV method were comparable with those obtained by reported analytical procedures.  相似文献   

10.
《Electroanalysis》2018,30(1):38-47
The aim of this study is the development of a miniaturized voltammetric method for the determination of an antimycobacterial agent 1‐hydroxy‐N‐(4‐nitrophenyl)naphthalene‐2‐carboxamide (HNN) in a single drop (20 μL) of a solution by cathodic and anodic voltammetry at a glassy carbon electrode. Cyclic voltammetry was used to investigate its redox properties followed by the optimization of differential pulse voltammetric determination in a regular 10 mL volume. The optimal medium for the analytical application of both cathodic and anodic voltammetry was found to be Britton‐Robinson buffer pH 7.0 and dimethyl sulfoxide (9 : 1, v/v). HNN gave one cathodic peak at around −0.6 V and one anodic peak at around +0.2 V vs. Ag|AgCl (3 mol L−1 KCl) reference electrode. Determination of HNN in a 10 mL volume gave the limit of quantification around 10 nmol L−1 by both adsorptive stripping anodic and cathodic voltammetry. Afterwards, miniaturized voltammetric methods in a single drop of solution (20 μL) were investigated. This approach requested some modifications of the cell design and voltammetric procedures. A novel method of removing dissolved oxygen in a single drop had to be developed and tested. Developed miniaturized voltammetric methods gave parameters comparable to the determination of HNN in 10 mL. The applicability of the miniaturized method was verified by the determination of HNN in a drop of a bacterial growth medium.  相似文献   

11.
In spite of the many unstandardized literature methods for the determination of the antioxidant activity/capacity (AOA/AOC) of food extracts, there are a very limited number of documented voltammetric nanosensors, despite the fact that commercial electrochemical devices for rapid AOA estimation are on the rise. The mechanism of the developed sensor is based on the chemical reduction of hexacyanoferrate(III) to hexacyanoferrate(II) by antioxidants, followed by the decrement of the cathodic current intensity of hexacyanoferrate(III) in proportion to antioxidant concentration. During voltammetric measurements, the surface of the glassy carbon electrode was coated with an o-phenylenediamine-aniline copolymer and gold nanoparticles were accumulated on this electrode surface to increase the conductivity. It was shown that the developed electrode gave a reversible voltammogram for the hexacyanoferrate(III)/(II) redox couple, and that the cathodic peaks due to strong antioxidants having a standard redox potential less than that of this couple (Eo < 0.36 V) continuously emerged at very close peak potentials. Single antioxidants as well as binary–ternary mixtures were analyzed with this electrode using square wave voltammetry. The trolox-equivalent antioxidant capacities of selected antioxidants were evaluated with this electrode. The modified voltammetric sensor allowed precise measurement of the total antioxidant capacity of plant tea samples such as green tea, lime, and coral moss, and was not interfered by the food preservative sulfite. The results of the developed voltammetric sensor were statistically compared with those of a reference differential pulse voltammetry-cupric reducing antioxidant capacity electrochemical method established in literature.  相似文献   

12.
Electron transfer is known to be an important step in the sequestering of iron by cellular ferritin. In this work, direct electron transfer between ferritin and a gold electrode was performed in order to probe its electron transfer kinetics. Gold electrodes were modified by the formation of self-assembled monolayers of 3-mercapto-propionic acid on the gold surface. Cyclic voltammetry using these electrodes shows that ferritin exhibits slow electron transfer kinetics at low potentials, yet fairly well-defined current—potential curves. In addition, the voltammetry indicates that adsorption of ferritin precedes the electron transfer step. Controlled potential electrolysis measurements yielded an n-value of 1910 electrons transferred per mole of ferritin. Cyclic voltammetry of a solution containing ferritin as well as nitrilotriacetate yields no electrolytic currents at potentials where the iron—nitrilotriacetate complex undergoes redox reactions, indicating that the currents observed in the voltammetry of ferritin were not due to free iron in the ferritin sample. In addition, the voltammetry of iron-free ferritin (apoferritin) did not yield appreciable currents, providing additional support to the suggestion that the observed voltammetric currents were due to the redox reactions of ferritin iron. Self-assembled monolayers containing carboxylate end groups effectively promoted the direct electron transfer of ferritin at a gold electrode, thus demonstrating that the electron transfer mechanisms of ferritin can now be probed electrochemically.  相似文献   

13.
A novel voltammetric method using the Ppyox/NFR/Au (poly pyrrole – nuclear fast red – gold) modified electrode was developed for simultaneous measurement of various combinations of ascorbic acid (AA) and methyldopa (MDA). Polypyrrole film was prepared by incorporation of nuclear fast red (NFR) as doping anion, during the electropolymerization of pyrrole onto a gold (Au) electrode in aqueous solution using cyclic voltammetric (CV) method, and then it was overoxidized at constant potential. Differential pulse voltammetry was utilized for the measurement of both analytes using modified electrode. Well‐separated voltammetric peaks were observed for ascorbic acid (AA) and methyldopa at the Ppyox/NFR/Au modified electrodes with peak separation of 0.210 V. It has been found that under optimum condition (pH 3.0), the oxidation of AA and MDA at the surface of the electrode occurs at a potential about 260 and 50 mV less positive than unmodified Au electrode respectively. The current catalytic oxidation peaks showed a linear dependent on the concentration of AA and MDA in the range of 9.0×10?6 to 1.0×10?3 and 1.0×10?7 to 2.0×10?5 mol L?1 respectively. The detection limit of 5.8×10?6 and 5.0×10?8 mol L?1 (S/N=3) were obtained for AA and MDA respectively. The modified electrode was used for determination of AA and MDA in some real samples such as human serum and tablet.  相似文献   

14.
A sensitive, simple and reproducible square-wave cathodic adsorptive stripping voltammetric method is developed for the determination of 2-mercaptobenzimidazole (MBIM) in different water samples using a static mercury drop electrode (SMDE) as a working electrode. The solution conditions and instrumental parameters were optimized for the determination of MBIM by square-wave cathodic adsorptive stripping voltammetry. This method is based on a sensitive adsorptive reduction peak of the MBIM at ?0.532 V vs. Ag/AgCl reference electrode in a Britton-Robinson buffer at pH 10.0. The linear concentration range was 20–600 ng ml?1 when using 0.0 V as the accumulation potential. The detection limit of the method was calculated to be 8.41 ng ml?1. The precision was excellent with relative standard deviations (n = 20) of 2.30%, 1.71%, 2.25% and 1.33% at MBIM concentrations of 40, 90, 200 and 500 ng ml?1, respectively. The proposed voltammetric method is used for the determination of MBIM in different spiked water samples.  相似文献   

15.
The oxidation of acetaminophen was studied at a glassy carbon electrode modified with multi-walled carbon nanotubes and a graphite paste. Cyclic voltammety, differential pulse voltammetry and square wave voltammetry at various pH values, scan rates, and the effect of the ratio of nanotubes to graphite were investigated in order to optimize the parameters for the determination of acetaminophen. Square wave voltammetry is the most appropriate technique in giving a characteristic peak at 0.52 V at pH 5. The porous nanostructure of the electrode improves the surface area which results in an increase in the peak current. The voltammetric response is linear in the range between 75 and 2000 ng.mL?1, with standard deviations between 0.25 and 7.8%, and a limit of detection of 25 ng.mL?1. The method has been successfully applied to the analysis of acetaminophen in tablets and biological fluids.  相似文献   

16.
《Electroanalysis》2006,18(1):89-94
The fabrication and characterization of very cheap disposable gold disk electrodes with reproducible area is reported. The innovation of the proposed procedure is the use of toner masks to define reproducible areas on uniform gold surfaces obtained from recordable compact disks (CD‐R). Toner masks are drawn in a laser printer and heat transferred to gold surfaces, defining exactly the electrodes area. The electrochemical behavior of these disposable electrodes was investigated by cyclic voltammetry in Fe(CN)64? solutions. The relative standard deviation for signals obtained from 10 different gold electrodes was below 1 %. The size of the disk electrodes can be easily controlled, as attested by voltammetric responses recorded by using electrodes with radii varying from 0.5 to 3.0 mm. The advantages of using this kind of electrode for analytical measurements of substances that strongly adsorb on the electrode surface such as cysteine are also addressed.  相似文献   

17.
The voltammetric behaviour of selenium(IV) was studied at platinum and gold electrodes in sulphuric acid, perchloric acid and potassium chloride media as a basis for its voltammetric detection. The best voltammetric behaviour was recorded at gold electrodes with perchloric acid as the supporting electrolyte. The concomitant presence of metals, such as copper or lead, and of model biomolecules, such as bovine serum albumin, in the solution resulted in a deterioration of the electrochemical response for selenium(IV). Quantitative detection of selenium(IV) by square wave anodic stripping voltammetry at both a millimetre-sized gold disc electrode and a microband electrode array revealed linear responses to selenium concentration in the ranges 5–15 μM and 0.1–10 μM, respectively, with 60 s preconcentration. The sensitivities were 6.4 μA μM−1 cm−2 and 100 μA μM−1 cm−2 at the disc and the microband array, respectively. The detection limit at the microband electrode array was 25 nM, illustrating the potentiality of such microelectrodes for the development of mercury-free analytical methods for the trace detection of selenium(IV).  相似文献   

18.
A novel carbon paste electrode modified with ZrO2 nanoparticles and an ionic liquid (n-hexyl-3- methylimidazolium hexafluorophosphate) was fabricated. The electrochemical study of the modified electrode, as well as its efficiency for simultaneous voltammetric oxidation of dopamine and uric acid is described. The electrode was also employed to study the electrochemical oxidation of dopamine and uric acid, using cyclic voltammetry, chronoamperometry and square wave voltammetry as diagnostic techniques. Square wave voltammetry exhibits linear dynamic range from 1.0 × 10?6 to 9.0 × 10?4 M for dopamine. Also, square wave voltammetry exhibits linear dynamic range from 9.0 × 10?6–1.0 × 10?3 M for uric acid. The modified electrode displayed strong function for resolving the overlapping voltammetric responses of dopamine and uric acid into two well-defined voltammetric peaks. In the mixture containing dopamine and uric acid, the two compounds can be well separated from each other with potential difference of 155 mV, which is large enough to determine dopamine and uric acid individually and simultaneously. Finally, the modified electrode was used for determination of dopamine and uric acid in real samples.  相似文献   

19.
A highly sensitive electrochemical biosensor for the detection of trace amounts of 8‐azaguanine has been designed. Double stranded (ds)DNA molecules are immobilized onto a glassy carbon electrode surface with Langmuir–Blodgett technique. The adsorptive voltammetric behaviors of 8‐azaguanine at DNA‐modified electrode were explored by means of cyclic voltammetry and square wave voltammetry. Compared with bare glassy carbon electrode (GCE), the Langmuir–Blodgett film modified electrode can greatly improve the measuring sensitivity of 8‐azaguanine. Under the optimum experimental conditions, the Langmuir–Blodgett film modified electrode in pH 3.0 Britton–Robinson buffer solutions shows a linear voltammetric response in the range of 5.0×10?8 to 1.0×10?5 mol L?1 with detection limit 9.0×10?9 mol L?1. The method proposed was applied successfully for the determination of 8‐azaguanine in diluted human urine with wonderful satisfactory.  相似文献   

20.
The adsorption behavior and differential pulse cathodic adsorptive stripping voltammetry of the pesticide Chlorpyrifos (CP) were investigated at the hanging mercury drop electrode (HMDE). The pesticide was accumulated at the HMDE and a well-defined stripping peak was obtained at –1.2 V vs Ag/AgCl electrode at pH 7.50. A voltammetric procedure was developed for the trace determination of Chlorpyrifos using differential pulse cathodic adsorptive stripping voltammetry (DP-CASV). The optimum working conditions for the determination of the compound were established. The peak current was linear over the concentration range 9.90 × 10–8– 5.96 × 10–7 mol/L of Chlorpyrifos. The influence of diverse ions and some other pesticides was investigated. The analysis of Chlorpyrifos in commercial formulations and treated waste water was carried out satisfactorily Received: 10 July 1997 / Revised: 1 April 1998 / Accepted: 6 April 1998  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号