首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An on-line method capable of the separation of arsenic species was developed for the speciation of arsenite As(III), arsenate As(V), monomethylarsenic (MMA) and dimethylarsenic acid (DMA) in biological samples. The method is based on the combination of high-performance liquid chromatograph (HPLC) for separation, UV photo oxidation for sample digestion and hydride generation atomic fluorescence spectrometry (HGAFS) for sensitive detection. The best separation results were obtained with an anion-exchange AS11 column protected by an AG11 guard column, and gradient elution with NaH2PO4 and water as mobile phase. The on-line UV photo oxidation with 1.5% K2S2O8 in 0.2 mol L(-1) NaOH in an 8 m PTFE coil for 40 s ensures the digestion of organoarsenic compounds. Detection limits for the four species were in the range of 0.11-0.15 ng (20 microL injected). Procedures were validated by analysis of the certified reference materials GBW09103 freeze-dried human urine and the results were in good agreement with the certified values of total arsenic concentration. The method has been successfully applied to speciation studies of blood arsenic species with no need of sample pretreatment. Speciation of arsenic in blood samples collected from two patients after the ingestion of realgar-containing drug reveals slight increase of arsenite and DMA, resulting from the digestion of realgar.  相似文献   

2.
Determination of arsenic species in marine samples by HPLC-ICP-MS.   总被引:1,自引:0,他引:1  
Arsenic speciation analysis in marine samples was performed using high performance liquid chromatography (HPLC) with ICP-MS detection. The separation of eight arsenic species viz. arsenite (As(III)), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenate (As(V)), arsenobetaine, trimethylarsine oxide (TMAO), arsenocholine and tetramethylarsonium ion (TeMAs) was achieved on a Shiseido Capcell Pak C18 column by using an isocratic eluent (pH 3.0), in which condition As(III) and MMA were co-eluted. The entire separation was accomplished in 15 min. The detection limits for 8 arsenic species by HPLC/ICP-MS were in the range of 0.02 - 0.10 microg L(-1) based on 3sigma of blank response (n=9). The precision was calculated to be 3.1-7.3% (RSD) for all eight species. The method then successfully applied to several marine samples e.g., oyster, scallop, fish, and shrimps. For the extraction of arsenic species from seafood products, the low power microwave digestion was employed. The extraction efficiency was in the range of 52.9 - 112.3%. Total arsenic concentrations were analyzed by using the microwave acid digestion. The total arsenics in the certified reference materials (DORM-2 and TORT-2) were analyzed and agreed with the certified values. The concentrations of arsenics in marine samples were in the range 6.6 - 35.1 microg g(-1).  相似文献   

3.
Arsenic speciation analysis in marine samples was performed using ion chromatography (IC) with inductively coupled plasma mass spectrometry (ICP‐MS) detection. The separation of eight arsenic species, viz. arsenite, monomethyl arsonic acid, dimethylarsinic acid, arsenate, arsenobetaine, tetramethylarsine oxide, arsenocholine and tetramethylarsonium ion was achieved on a Dionex AS4A (weaker anion exchange column) by using a nitric acid pH gradient eluent (pH 3.3 to 1.3). The entire separation was accomplished in 12 min. The detection limits for the eight arsenic species by IC–ICP‐MS were in the range 0.03–1.6 µ g l?1, based on 3σ of the blank response (n = 6). The repeatability and day‐to‐day reproducibility were calculated to be less than 10% (residual standard deviation) for all eight species. The method was validated by analyzing a certified reference material (DORM‐2, dogfish muscle) and then successfully applied to several marine samples, e.g. oyster, fish muscle, shrimp and marine algae. The low power microwave digestion was employed for the extraction of arsenic from seafood products. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

4.
CZE for the speciation of arsenic in aqueous soil extracts   总被引:2,自引:0,他引:2  
We developed two separation methods using CZE with UV detection for the determination of the most common inorganic and methylated arsenic species and some phenylarsenic compounds. Based on the separation method for anions using hydrodynamic sample injection the detection limits were 0.52, 0.25, 0.27, 0.12, 0.37, 0.6, 0.6, 1.2 and 1.0 mg As/L for phenylarsine oxide (PAO), p-aminophenylarsonic acid (p-APAA), o-aminophenylarsonic (o-APAA), phenylarsonic acid (PAA), 4-hydroxy-3-nitrobenzenearsonic acid (roxarsone), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenite or arsenious acid (As(III)) and arsenate (As(V)), respectively. These detection limits were improved by large-volume sample stacking with polarity switching to 32, 28, 14, 42, 22, 27, 26 and 27 microg As/L for p-APAA, o-APAA, PAA, roxarsone, MMA, DMA, As(III) and As(V), respectively. We have applied both methods to the analysis of the arsenic species distribution in aqueous soil extracts. The identification of the arsenic species was validated by means of both standard addition and comparison with standard UV spectra. The comparison of the arsenic species concentrations in the extracts determined by CZE with the total arsenic concentrations measured by inductively coupled plasma-atomic emission spectroscopy (ICP-AES) indicated that CZE is suited for the speciation of arsenic in environmental samples with a high arsenic content. The extraction yield of phenylarsenic compounds from soil was derived from the arsenic concentrations of the aqueous soil extracts and the total arsenic content of the soil determined by ICP-AES after microwave digestion. We found that 6-32% of the total amount of arsenic in the soil was extractable by a one-step extraction with water in dependence on the type of arsenic species.  相似文献   

5.
The simultaneous separation and determination of arsenite As(III), arsenate As(V), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB), and arsenocholine (AsC) in rice samples have been carried out in one single anion‐exchange column run by high‐performance liquid chromatography with inductively coupled plasma mass spectrometry. To estimate the effect of variables on arsenic (As) speciation, the chromatographic conditions including type of competing anion, ionic strength, pH of elution buffer, and flow rate of mobile phase have been investigated by a univariate approach. Under the optimum chromatographic conditions, baseline separation of six As species has been achieved within 10 min by gradient elution program using 4 mM NH4HCO3 at pH 8.6 as mobile phase A and 4 mM NH4HCO3, 40 mM NH4NO3 at pH 8.6 as mobile phase B. The method detection limits for As(III), As(V), MMA, DMA, AsB, and AsC were 0.4, 0.9, 0.2, 0.4, 0.5, and 0.3 μg/kg, respectively. The proposed method has been applied to separation and quantification of As species in real rice samples collected from Hunan Province, China. The main As species detected in all samples were As(III), As(V) and DMA, with inorganic As accounting for over 80% of total As in these samples.  相似文献   

6.
A fast, sensitive and simple non-chromatographic analytical method was developed for the speciation analysis of toxic arsenic species in cereal samples, namely rice and wheat semolina. An ultrasound-assisted extraction of the toxic arsenic species was performed with 1 mol L− 1 H3PO4 and 0.1% (m/v) Triton XT-114. After extraction, As(III), As(V), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) concentrations were determined by hydride generation atomic fluorescence spectrometry using a series of proportional equations corresponding to four different experimental reduction conditions. The detection limits of the method were 1.3, 0.9, 1.5 and 0.6 ng g− 1 for As(III), As(V), DMA and MMA, respectively, expressed in terms of sample dry weight. Recoveries were always greater than 90%, and no species interconversion occurred. The speciation analysis of a rice flour reference material certified for total arsenic led to coherent results, which were also in agreement with other speciation studies made on the same certified reference material.  相似文献   

7.
High-performance liquid chromatography (h.p.l.c.) is used for separation of arsenite, arsenate, monomethylarsinate (MMA) and dimethylarsonate (DMA) followed by continuous sodium tetrahydroborate reduction and atomic absorption spectrometric detection. Sample preconcentration, offering improved detection limits for the individual species and the removal of matrix interferences, is achieved with a pellicular anion-exchange column. The arsenic species are then separated on a strong anion-exchange column placed in series with the preconcentration column. Detection limits of 2 ng (as arsenic) for arsenite, arsenate and MMA, and 1 ng for DMA. Results for arsenic species in soil waters and commercial bottle waters are given.  相似文献   

8.
Arsenic compounds including arsenous acid (As(III)), arsenic acid (As(V)), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) were separated by high-performance liquid chromatography (HPLC) and detected by inductively coupled plasma mass spectrometry (ICP-MS). A Hamilton PRX-100 anionic-exchange column and a pH 8.5 K2HPO4/KH2PO4 5.0 × 10−3 mol L−1 mobile phase were used to achieve arsenic speciation. The separation of arsenic species provided peaks of As(III) at 2.75 min, DMA at 3.33 min, MMA at 5.17 min and As(V) at 12.5 min. The detection limits, defined as three times the standard deviation of the lowest standard measurements, were found to be 0.2, 0.2, 0.3 and 0.5 ng mL−1 for As(III), DMA, MMA and As(V), respectively. The relative standard deviation values for a solution containing 5.0 μg L−1 of As(III), DMA, MMA and As(V) were 1.2, 2.1, 2.5 and 3.0%, respectively. This analytical procedure was applied to the speciation of arsenic compounds in drinking (soft drink, beer, juice) samples. The validation of the procedure was achieved through the analysis of arsenic compounds in water and sediment certified reference materials.  相似文献   

9.
Le XC  Cullen WR  Reimer KJ 《Talanta》1994,41(4):495-502
An arsenic specific detection system utilizing on-line microwave digestion and hydride generation atomic absorption spectrometry (MD/HGAAS) is described for arsenic speciation by using high performance liquid chromatography (HPLC). Both ion exchange chromatography and ion pair chromatography have been studied for the separation of arsenite, arsenate, monomethylarsonic acid (MMAA), dimethylarsinic acid (DMAA), and arsenobetaine (AB). When the commonly used mobile phases, phosphate and carbonate buffers at pH 7.5, are used on an anion exchange column, arsenite and AB co-elute. However, selective determination of these two arsenic compounds can be achieved by using the new detection system. Partial separation between arsenite and AB can be achieved by increasing the mobile phase pH to 10.3 and by using a polymer based anion exchange column. The detection limit obtained by using anion exchange chromatography with MD/HGAAS detection is approximately 10 ng/ml (or 200 pg for a 20-mul sample injection) for arsenite, DMAA and AB, 15 ng/ml (or 300 pg) for MMAA, and 20 ng/ml (or 400 pg) for arsenate. Complete separation of the five arsenic compounds is achieved on a reversed phase C18 column by using sodium heptanesulfonate as ion pair reagent. Comparable resolution between chromatographic peaks is obtained by using MD/HGAAS detection and inductively coupled plasma mass spectrometry (ICPMS) detection.  相似文献   

10.
A coupling between column liquid chromatography (LC) and atomic fluorescence spectrometry was developed for arsenic speciation. After separation, the compounds are oxidised on-line by UV irradiation, volatilised by hydride-generation and carried to the detector by a stream of argon. A combination of anion-exchange and hydrophobic interactions in a single column (Dionex AS7) was found suitable for the simultaneous separation of organic and inorganic species. Twelve compounds (arsenite, arsenate, monomethylarsonic acid, dimethylarsinic acid, arsenobetaine, arsenocholine, trimethylarsine oxide, tetramethylarsonium ion and four arsenosugars) were separated using an acetate buffer and a nitric acid solution as mobile phases. Limits of detection are 4-22 pg. The technique was applied to three marine samples. Arsenobetaine was detected as the main species in all samples, with concentrations varying from 59 to 1947 ng(As) g(-1) of fresh mass.  相似文献   

11.
We describe a method for continuously monitoring both hydride- and nonhydride-forming arsenic species in 10-microL microdialysate samples by coupling together on-line high-performance liquid chromatography (HPLC), a post-column UV/TiO2 film reactor, and hydride generation (HG) inductively coupled plasma mass spectrometry (ICP-MS). To maximize the signal intensities of the desired arsenic species, we optimized the photocatalytic oxidation efficiency of the analyte species and used a rapid on-line pre-reduction process to convert the oxidized species into As(III) prior to HG-ICP-MS determination. The UV/nano-TiO2 film reactor was manufactured by coating nano-TiO2 onto the interior of a glass tube. Impregnation and sol-gel methods were employed to deposit the TiO2 films, and their effectiveness for the oxidation of organic arsenicals was compared. To enhance the decomposition efficiency of organic arsenicals, we investigated the effects of the acidity and the composition of the column effluent. Because of the improved HG efficiency toward the tested arsenicals and the adoption of a segmented flow technique to retain the peak resolution in our on-line LC-UV/nano-TiO2 film reactor-HG-ICP-MS instrument, the detection limits for arseneous acid [As(III)], monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenic acid [As(V)], and arsenobetaine (AsB) were all in the submicrogram-per-liter range (based on 3 sigma) for 10-microL injections. A series of validation experiments--analyses of certified reference urine and rabbit serum samples--indicated that these methods can be applied satisfactorily to the continuous determination of As(III), MMA, DMA, As(V), and AsB in blood and in the extracellular space of target organs.  相似文献   

12.
The determination of seven arsenic species in seafood was performed using ion exchange chromatography on an IonPac AS7 column with inductively coupled plasma mass spectrometry detection after microwave assisted extraction. The effect of five parameters on arsenic extraction recoveries was evaluated in certified reference materials. The recoveries of total arsenic and of arsenic species with the two best extraction media (100% H2O and 80% aqueous MeOH) were generally similar in the five seafood certified reference materials considered. However, because MeOH co-elutes with arsenite, which would result in a positively biased arsenite concentration, the 100% H2O extraction conditions were selected for validation of the method. Figures of merit (linearity, LOQs (0.019-0.075 mg As kg−1), specificity, trueness (with recoveries between 82% (As(III)) and 104% (As(V) based on spikes or certified concentrations), repeatability (3-14%), and intermediate precision reproducibility (9-16%) of the proposed method were satisfactory for the determination of arsenite, monomethylarsonic acid, dimethylarsinic acid, arsenate, arsenobetaine and arsenocholine in fish and shellfish. The performance criteria for trimethylarsine oxide, however, were less satisfactory. The method was then applied to 65 different seafood samples. Arsenobetaine was the main species in all samples. The percentage of inorganic arsenic varied between 0.4-15.8% in shellfish and 0.5-1.9% at the utmost in fish. The main advantage of this method that uses only H2O as an extractant and nitric acid as gradient eluent is its great compatibility with the long-term stability of both IEC separation and ICP-MS detection.  相似文献   

13.
Flow injection analysis (FIA) and high-performance liquid chromatography double-focusing sector field inductively coupled plasma mass spectrometry (HPLC-DF-ICP-MS) were used for total arsenic determination and arsenic speciation of xylem sap of cucumber plants (Cucumis sativus L.) grown in hydroponics containing 2 μmol dm−3 arsenate or arsenite, respectively. Arsenite [As(III)], arsenate [As(V)] and dimethylarsinic acid (DMA) were identified in the sap of the plants. Arsenite was the predominant arsenic species in the xylem saps regardless of the type of arsenic treatment, and the following concentration order was determined: As(III) > As(V) > DMA. The amount of total As, calculated taking into consideration the mass of xylem sap collected, was almost equal for both treatments. Arsenite was taken up more easily by cucumber than arsenate. Partial oxidation of arsenite to arsenate (<10% in 48 h) was observed in the case of arsenite-containing nutrient solutions, which may explain the detection of arsenate in the saps of plants treated with arsenite.  相似文献   

14.
We have developed an on-line digestion device-based on the nano-TiO2-catalyzed photooxidation of arsenic species—for coupling between microbore anion-exchange chromatography (μ-LC) and hydride generation (HG)-inductively coupled plasma mass spectrometry (ICP-MS) systems that can be used for the determination of urinary arsenic species. To maximize the signal intensities of the desired arsenic species, we optimized the photocatalytic oxidation efficiency of the analyte species and developed a rapid on-line pre-reduction process for converting the oxidized species into As(III) prior to HG-ICP-MS determination. Under the optimized conditions for the nano-TiO2-catalyzed photooxidation-i.e., using 1 g of nano-TiO2 per-liter, at pH 5.2, and illuminating for 3 min- As(III), monomethylarsenoic acid (MMA), and dimethylarseinic acid (DMA) can be converted quantitatively into As(V). To attain maximal hydride generation efficiency, 0.5% Na2S2O4 solution, which can reduce As(V) to As(III) virtually instantaneously upon on-line mixing, was added as a pre-reductant prior to performing the HG step. In light of all the HG efficiency of tested arsenicals were improved and a segmented-flow technique was employed to avoid the loss of peak resolution when using our proposed on-line μ-LC-UV/nano-TiO2/HG-ICP-MS, the detection limits for As(III), MMA, DMA, and As(V) were all in the range of sub-microgram-per-liter (based on 3 sigma). A series of validation experiments-analysis of neat and spiked urine samples-indicated that our proposed methods can be applied satisfactorily to the determination of As(III), MMA, DMA, and As(V) in urine samples.  相似文献   

15.
The potential of coupling anion-exchange high-performance liquid chromatography, hydride generation and atomic fluorescence spectrometry (HPLC–HG–AFS) for arsenic speciation is considered. The effects of hydrochloric acid and sodium tetrahydroborate concentrations on signal-to-background ratio, as well as argon and hydrogen flow rates, were investigated. Detection limits for arsenite, dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and arsenate were 0.17, 0.45, 0.30 and 0.38 μg l−1, respectively, using a 20-μl loop. Linearity ranges were 0.1–500 ng for As(III) and MMA (as arsenic), and 0.1–800 ng for DMA and As(V) (as arsenic). Arsenobetaine (AsB) was also determined by introducing an on-line photo-oxidation step after the chromatographic separation. In this case the limits of detection and linear ranges for the different species studied were similar to the values obtained previously for As(V). The technique was tested with a human urine reference material and a volunteer's sample. © 1998 John Wiley & Sons, Ltd.  相似文献   

16.
A novel absorbent was prepared by dimercaptosuccinic acid chemically modifying mesoporous titanium dioxide and was employed as the micro-column packing material for simultaneous separation/preconcentration of inorganic arsenic and antimony species. It was found that both trivalent and pentavalent of inorganic As and Sb species could be adsorbed quantitatively on dimercaptosuccinic acid modified TiO2 within a pH range of 4–7, and only As(III) and Sb(III) could be quantitatively retained on the micro-column within a pH range of 10–11 while As(V) and Sb(V) were passed through the micro-column without the retention. Based on this fact, a new method of flow injection on-line micro-column separation/preconcentration coupled to inductively coupled plasma optical emission spectrometry was developed for simultaneous speciation of trace inorganic arsenic and antimony in natural waters. Under the optimized conditions, an enrichment factor of 10 and sampling frequency of 10 h− 1 were obtained with on-line mode. The detection limits of As(III), As(V), Sb(III), and Sb(V) are 0.53, 0.49, 0.77 and 0.71 ng mL− 1 for on-line mode and as low as 0.11, 0.10, 0.15 and 0.13 ng mL− 1 for off-line mode due to its higher enrichment factor (50), respectively. The relative standard deviations of two modes are less than 6.7% (C = 20 ng mL− 1, n = 7). The concentration ratio of lower oxidation states/higher oxidation states changing from 1:10 to 10:1 has no obvious effect on the recoveries of As(III) and Sb(III). In order to validate the developed method, two certified reference materials of GSBZ5004-88 and GBW(E)080545 water sample were analyzed and the determined values are in good agreement with the certified values. The proposed method was successfully applied to the simultaneous speciation of inorganic arsenic and antimony in natural waters.  相似文献   

17.
An automatic system, based on the on-line coupling of high-performance liquid chromatography (HPLC) separation, post column microwave digestion, and cold-vapor atomic fluorescence spectrometry (CVAFS) detection, was proposed for the speciation analysis of four mercury compounds. Post column microwave digestion, in the presence of potassium persulfate (in HCl), was applied in the system to improve the conversion efficiency of three organic mercury compounds into inorganic mercury. Parameters influencing the on-line digestion efficiency and the separation effect were optimized. To avoid water vapor and methanol entering into the atomic fluorescence detector, ice-water mixture bath was used to cool the microwave-digested sample solution. Four mercury species including inorganic mercury chloride (MC), methylmercury chloride (MMC), ethylmercury chloride (EMC) and phenylmercury chloride (PMC) were baseline separated within 13 min by using RP C18 column with a mobile phase of 50% (v/v) methanol containing 10 mmol l−1 tetrabutyl ammonium bromide and 0.1 mol l−1 sodium chloride pumped at 1.2 ml min−1. Seafood samples, composed of three gastropod species and two bivalve species from Yantai port, China, have been analyzed by the proposed method. Dogfish muscle (DORM-2) was analyzed to verify the accuracy of the method and the result was in good agreement with the certified value.  相似文献   

18.
Ion-pair reverse-phase HPLC-inductively coupled plasma (ICP) MS was employed to determine arsenite [As(III)], dimethyl arsenic acid (DMA), monomethyl arsenic (MMA) and arsenate [As(V)] in Chinese brake fern (Pteris vittata L.). The separation was performed on a reverse-phase C18 column (Haisil 100) by using a mobile phase containing 10 mM hexadecyltrimethyl ammonium bromide (CTAB) as ion-pairing reagent, 20 mM ammonium phosphate buffer and 2% methanol at pH 6.0. The detection limits of arsenic species with HPLC-ICP-MS were 0.5, 0.4, 0.3 and 1.8 ppb of arsenic for As(III), DMA, MMA, and As(V), respectively. MMA has been shown for the first time to experimentally convert to DMA in the Chinese brake fern, indicating that Chinese brake fern can convert MMA to DMA by methylation.  相似文献   

19.
An improved analytical procedure is presented for the separation and simultaneous determination of hydride-forming (toxic) and not hydride-forming (non-toxic) arsenic species in human urine. Separation was performed by cation-exchange chromatography using a new solid phase type based on the continuous bed chromatography (CBC) technology. This column permits by a factor of 4 higher flow rates than conventional columns resulting in a drastical reduction of retention times without any loss of resolution. Using this type of column, arsenobetaine (AsBet), arsenocholine (AsChol), and dimethylarsinic acid (DMA) were separated from the more toxic arsenic species arsenous acid (As(III)), arsenic acid (As(V)), and methylarsonic acid (MA) within only 4 min. The HPLC system was coupled via a flow injection system and either a UV or a microwave (MW) reactor to the HG-AAS instrument. UV photolysis and MW digestion were used to transform AsBet and AsChol to hydride-forming species and to make them accessible to HG-AAS. UV photolysis turned out to be more suitable for this application than MW digestion, because the latter technique led to peak broadening and poorer performance. The described procedure was applied to the determination of arsenic species in urine samples of non-occupationally exposed persons before and 12 h after seafood consumption. Detection limits were about 1 μg/L for each arsenic species. After consumption, the AsBet and DMA excretion increased by at least a factor of 150 for AsBet and by a factor of 6 for DMA, respectively, while the excretion of the other species did not increase significantly. This invalidates the use of total urinary arsenic as well as total hydride-forming arsenic as an indicator for exposure to inorganic arsenic. Received: 12 August 1998 / Revised: 30 October 1998 / Accepted: 24 November 1998  相似文献   

20.
Enzymatic hydrolysis of seafood materials for isolating arsenic species (As(III), As(V), DMA and AsB) has been successfully performed by assisting the procedure with ultrasound energy (35 kHz) supplied by an ultrasound water-bath. The use of pepsin, as a proteolytic enzyme, under optimized operating conditions (pH 3.0, temperature 40 °C, enzyme to sample ratio of 0.3) led to an efficient assistance of the enzymatic process in a short period of time (from 4.0 to 30 min). The enzymatic extract was then subjected to a clean-up procedure based on ENVI-Carb™ solid phase extraction (SPE). An optimized anion exchange high performance liquid chromatography (HPLC) coupled to inductively coupled plasma-mass spectrometry (ICP-MS) permitted the fast separation (less than 15 min) of six different arsenic species (arsenite, As(III); arsenate, As(V); dimethylarsinic acid, DMA; and arsenobetaine, AsB; as well as monomethylarsonic acid, MMA; and arsenocholine, AsC) in a single run. Relative standard deviations (n = 11) of the over-all procedure were 7% for AsB and DMA, 11% for As(III) and 9% for MMA. HPLC–ICP-MS determinations were performed using aqueous calibrations covering arsenic concentrations of 0, 5, 10, 25, 100 and 200 μg L−1 (expressed as arsenic) for As(III), As(V), MMA, DMA and AsC; and 0, 125, 250, 500, 750, 1000 and 2000 μg L−1 (expressed as arsenic) for AsB. Germanium (5 μg L−1) was used as an internal standard. Analytical recoveries from the anion exchange column varied from 96 to 105% (enzymatic digests spiked with low target concentrations), from 97 to 104% (enzymatic digests spiked with intermediate target concentrations), and from 98 to 103% (enzymatic digests spiked with high target concentrations). The developed method was successfully applied to two certified reference materials (CRMs), DORM-2 and BCR 627, which offer certified AsB and DMA contents, and also to different seafood samples (mollusks, white fish and cold water fish). Good agreement between certified and found AsB concentrations was achieved when analyzing both CRMs; and also, between certified and found DMA concentrations in BCR 627. In addition, the sum of the different arsenic species concentrations found in most of the analyzed samples was statistically similar to the assessed total arsenic concentrations after a total sample matrix decomposition treatment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号