首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple flame atomic absorption spectrometric (FAAS) procedure for the determination of lead, bismuth, gold, palladium and cadmium as impurities in Raney nickel and nickel oxide was developed using a preconcentration step on an Amberlite XAD-16 resin packed column. Lead, bismuth, gold, palladium and cadmium were quantitatively recovered and separated from a solution containing 1 M HCl and 0.3 M NaI by the column system. Effects of the various parameters such as reagent concentrations, sample volume, matrix effects, etc. have been investigated. Under optimized conditions, the relative standard deviation of the combined method of sample treatment, preconcentration and determination with FAAS (n = 7) is generally lower than 12%. The limit of detection (3s, n = 20) was between 10–270 ng/g. The results were used for separation and preconcentration of five trace elements from nickel matrices. Received: 8 February 2000 / Revised: 31 March 2000 / Accepted: 7 April 2000  相似文献   

2.
A simple and highly selective flow injection (FI) on-line preconcentration and separation flame atomic absorption spectrometric (FAAS) method was developed for the determinations of trace amounts of silver, gold and palladium. The selective preconcentration of the noble metals was achieved in a wide range of sample acidity (0.1-6 M HNO3 or HCl) on a microcolumn packed with amidinothioureido-silica gel (ATuSG). The analytes retained on the column were effectively eluted with 5.0% thiourea solution. The analytical procedure was optimized for sample acidity, elution, interferences, flow rate of sampling and eluting, and concentration of sample. Common co-existing cations and anions did not interfere with the preconcentration and determination of the three metals. At a sample loading flow rate of 4.5 ml min−1 with 60 s preconcentration, detection limits (3σ) of 1.1 ng ml−1 Ag, 13 ng ml−1 Au and 17 ng ml−1 Pd were obtained. The precisions (R.S.D., n=11) were 1.2% for Ag, 1.2% for Au and 1.7% for Pd, respectively. The detection limits can be further improved by increasing sample volume. The analytical results obtained by the proposed method for a number of standard reference materials were in good agreement with the certified values.  相似文献   

3.
A sensitive and simple solid-phase preconcentration procedure for enrichment of cadmium prior to analysis by flame atomic absorption spectrometry (FAAS) is described. The method is based on the adsorption of cadmium as CdI42− on naphthalene-methyltrioctylammonium chloride adsorbent, elution by nitric acid and subsequent determination by FAAS. The effect of pH, iodide concentration, sample flow rate, volume of the sample and diverse ions on the recovery of the analyte was investigated and optimum conditions were established. A preconcentration factor of 40 was achieved using the optimum conditions. The calibration graph was linear in the range 1-100 ng ml−1 cadmium in the initial solution. The detection limit based on the 3Sb criterion was 0.6 ng ml−1 and the relative standard deviations (RSD) were 3.9 and 1.05% for 5 and 40 ng ml−1, respectively (n=8). The method was successfully applied to the determination of cadmium added to river, tap and Persian Gulf water samples.  相似文献   

4.
A preconcentration method of gold, palladium and copper based on the sorption of Au (III), Pd (II) and Cu (II) ions on a column packed with 3-(2-aminoethylamino)propyl bonded silica gel is described. The modified silica gel was synthesized and characterized by FT-IR and C, H, N elemental analysis. At column preconcentration, the effects of parameters such as pH, volume, flow rate, matrix constituents of solutions and type of eluent on preconcentration of gold, palladium and copper were studied. The recoveries of Au (III), Pd (II) and Cu (II) were 98.93±0.51, 98.81±0.36 and 99.21±0.42 % at 95 % confidence level, respectively. The detection limits (δ) of the elements were 0.032, 0.016 and 0.012 μg ml−1, respectively. The preconcentration method was applied for determination of gold and palladium in certified reference material SARM 7B and copper in river and synthetic seawater by FAAS. Gold, palladium and copper were determined with relative error lower than 10 %.  相似文献   

5.
A microcolumn of alumina modified with sodium dodecyl sulfate (SDS) and 1-(2-pyridylazo)-2-naphthol (PAN) was prepared for the preconcentration of trace nickel from water samples for a flame atomic absorption spectrometry (FAAS) determination. Under optimized conditions (pH = 4.0; flow rate, 5 mL min–1) nickel (II) was retained on the column. The nickel collected on the column was eluted with 5 mL of 0.5 M nitric acid. Recovery was greater than 96.7%. A concentration factor of 300 can be achieved by passing 1500 mL of sample through the microcolumn. The relative standard deviation (ten replicate analyses) at the 40 ng mL–1 level for nickel was 2.4%, and the corresponding limit of detection (based on 3) was 0.06 ng mL–1. The method was applied to the determination of Ni in waste and mineral waters.  相似文献   

6.
It has been shown that 2N sodium sulphide reagent can be used efficiently for separating. 1.Barium from rhenium, platinum, gold, bismuth, palladium, lead or cadmium. 2.Strontium, calcium and magnesium from rhenium, platium, gold, mercury, bismuth, palladium, lead or cadmium  相似文献   

7.
Praveen RS  Daniel S  Rao TP  Sampath S  Rao KS 《Talanta》2006,70(2):437-443
A sensitive and efficient flow injection preconcentration and matrix-separation technique using exfoliated graphite (EG) as column material was developed prior to flame atomic absorption spectrometry (FAAS) determination of palladium(II) in street/fan blade dust and rock samples. The method is based on the sorption of palladium(II)—diethylammonium dithiocarbamate chelate (which was found to be better among various thioligands) complex on to EG material and its subsequent elution with acidified methanol (0.01 M HCl in methanol). Using 8 ml of the sample, the detection limit achieved was 1.0 μg l−1. The accuracy of the method developed was checked by analysing certified reference material SARM-7. The precision obtained for five successive determination of 100 μg l−1 of palladium(II) was 2.4%. The performance of EG material was compared with allotropes of carbon in terms of pH, chelate concentration, weight of column material, sensitivity enhancement (w.r.t. conventional FAAS), detection limit, calibration range, selectivity and precision. Furthermore, performance of the EG material packed column was compared with commercially available C18 bonded silica gel/alumina columns for on-line FIA-FAAS determination of palladium(II).  相似文献   

8.
《Analytical letters》2012,45(3):513-525
ABSTRACT

A preconcentration method based on the use of an activated carbon column has been established for flame atomic absorption spectrometric determinations of gold, silver and palladium. The analytes were sorbed on the column as a complex of dithiophosphoric acid O, O-diethyl ester (DDTP). The sorbed analytes were eluted through the column with 2M NH3 in acetone. Quantitative recoveries (≥95 %) for gold, silver and palladium were obtained from acidic solutions. The developing method was successfully applied to the determination of trace amounts of gold, silver and palladium in some samples with satisfactory results (relative standard deviation < 7 %; relative error < 3 %).  相似文献   

9.
We have immobilized living and non-living Escherichia coli (E. coli) bacteria on multiwalled carbon nanotubes (MWCNT) and used such materials as a biosorbent for the separation and preconcentration of copper, cobalt, cadmium and nickel prior to their determination by flame atomic absorption spectrometry (FAAS). E. coli bacteria cells were mixed with MWCNTs in a 1:1 ratio, dried and placed at the tip of a 50-mL syringe. The ions were retained on the sorbent and then eluted by drawing and ejecting back the sample (or standard solution) and an eluent, respectively. The effects of various experimental parameters on the sorption and elution were investigated. The analytes were quantitatively retained (at pH values of 7) and eluted (with 0.5 M nitric acid) with high precision, the RSD being <5%. The performances of the new sorbents were compared using certified reference materials. The sorbent modified with living E. coli has a higher adsorption capacity and displays somewhat better recoveries compared to sorbent based on non-living E. coli. Both sorbents were successfully used for the separation and preconcentration of copper, cobalt, cadmium and nickel prior to their determination by flame atomic absorption spectrometry.
Figure
SEM photograph of (a) living E. coli immobilized on MWCNT and (b) non-living E. coli immobilized on MWCNT  相似文献   

10.
An on-line solid phase extraction (SPE) preconcentration system coupled to flame atomic absorption spectrometer (FAAS) was developed for determination of copper and cadmium at μg L−1 level. The method is based on the on-line retention of copper and cadmium on a microcolumn of alumina modified with sodium dodecyl sulfate (SDS) and 1,10-phenanthroline and subsequent elution with ethanol and determination by FAAS. The effect of chemical and flow variables that could affect the performance of the system was investigated. The relative standard deviation (n = 6) at 20 μg L−1 level for copper and cadmium were 1.4 and 2.2% and the corresponding limits of detection (based on 3σ) were 0.04 and 0.14 μg L−1, respectively. The method was successfully applied to determination of copper and cadmium in human hair and water samples.  相似文献   

11.
Silica gel chemically modified with mercaptopropyl groups is proposed for the extraction and preconcentration of palladium. This silica gel extracts palladium(II) at an acidity from 6M HCl to pH 4 with distribution ratios at a level of n× 104 g/cm3. Hyphenated procedures for the adsorption–photometric determination of palladium with detection limits of 0.1 g/0.1 g of the adsorbent have been developed. The procedure includes the adsorption preconcentration of palladium, elution by hot (50 ± 5°C) 8% thiourea in 1M HCl, and atomic absorption determination of palladium in the eluate (detection limit is 0.05 g/mL). The procedures were applied to the determination of palladium in standard reference samples of copper–nickel ore and copper concentrate.  相似文献   

12.
A novel method of on-line solid phase extraction (SPE) preconcentration has been established for the determination of cadmium in environmental water samples by flame atomic absorption spectrometry (FAAS). The method is based on the on-line retention of cadmium on a micro column of nanometer Silicon Hydroxyapatite (Si-HAP) modified with 1-phenyl-3-methyl-4-bonzoil-5-pyrazone (PMBP) and subsequent elution with 1.0?M thiourea and determination by FAAS. The effect of various parameters that could affect the performance of the system was investigated. The enrichment factor (EF) for cadmium (II) was 250. The limit of detection (LOD) obtained under optimum conditions was 0.28?µg?L?1 and the relative standard deviation (RSD) for seven replicates at 100?µg?L?1 Cd2+ concentration level was 1.4%. The method was applied to water samples and standard reference materials. The accuracy was assessed through recovery experiments and comparing the results with the accepted values of standard reference material.  相似文献   

13.
《Analytical letters》2012,45(13):2805-2820
ABSTRACT

The preconcentration and separation of platinum and palladium from weakly acidic solution (pH=4) were done on microcolumn packed with Cellex-T resin. Selective platinum elution from the column was performed with 0.01 mol/l glycine solution at pH=12, while for palladium elution 1.2 mol/l thiourea (pH=0.5) or 4.0 mol/l potassium thiocyanate (pH=1) may be used. As the detection technique was used either FAAS or GFAAS, depending on the concentration of studied metals in the eluate.  相似文献   

14.
《Analytical letters》2012,45(15):2801-2810
Abstract

A simple method for atomic absorption spectrometric determination of lead, copper, cadmium and nickel in drinking water samples after preconcentration by sorbing 1-(2-pyridylazo) 2-naphthol (PAN) complex of these metals on an activated carbon column has been established. The metal/PAN complexes were quantitatively retained on the activated carbon in the pH range 6-8. Metals retained on the activated carbon column were completely eluted with 2M HCl in acetone. This method was applied to the determination of lead, copper, cadmium and nickel in drinking water samples and good results were obtained (Recoveries >95%, relative standard deviations <7%, relative error <3%).  相似文献   

15.
《Analytical letters》2012,45(11):2285-2295
Abstract

Multi‐walled carbon nanotubes (MWNTs) were used as sorbent for flow injection (FI) on‐line microcolumn preconcentration coupled with flame atomic absorption spectrometry (FAAS) for determination of trace cadmium and copper in environmental and biological samples. Effective preconcentration of trace cadmium and copper was achieved in a pH range of 4.5–6.5 and 5.0–7.5, respectively. The retained cadmium and copper were efficiently eluted with 0.5 mol L?1 HCl for on‐line FAAS determination. The MWNTs packed microcolumn exhibited fairly fast kinetics for the adsorption of cadmium and copper, permitting the use of high sample flow rates up to at least 7.8 mL min?1 for the FI on‐line microcolumn preconcentration system without loss of the retention efficiency. With a preconcentration time of 60 sec at a sample loading flow rate of 4.3 mL min?1, the enhancement factor was 24 for cadmium and 25 for copper at a sample throughput of 45 h?1. The detection limits (3σ) were 0.30 and 0.11 µg L?1 for Cd and Cu, respectively. The precision (RSD) for 11 replicate measurements was 2.1% at the 10‐µg L?1 Cd level and 2.4% at the 10‐µg L?1 Cu level. The developed method was successfully applied to the determination of trace Cd and Cu in a variety of environmental and biological samples.  相似文献   

16.
An on-line preconcentration procedure for the determination of bismuth by flame atomic absorption spectrometry (FAAS) has been described. Lewatit TP-207 chelating resin, including iminodiacetate group, packed in a minicolumn was used as adsorbent material. Bi(III) was sorbed on the chelating resin, from which it could be eluted with 3 mol L−1 HNO3 and then introduced directly to the nebulizer-burner system of FAAS. Best preconcentration conditions were established by testing different resin quantities, acidity of sample, types of eluent, sample and eluent solution volumes, adsorption and elution flow rates, and effect of interfering ions. The detection limit of the method was 2.75 μg L−1 while the relative standard deviation was 3.0% for 0.4 μg mL−1 Bi(III) concentration. The developed method has been applied successfully to the determination of bismuth in pharmaceutical cream, standard reference materials and various natural water samples with satisfactory results.  相似文献   

17.
Ibrahim S.I. Adam 《Talanta》2009,77(3):1160-1164
A newly simple flow injection wetting-film extraction system coupled to flame atomic absorption spectrometry (FAAS) has been developed for trace amount of cadmium determination. The sample was mixed on-line with sodium diethyl dithiocarbamate and the produced non-charged Cd(II)-diethyl dithiocarbamate (DDTC) chelate complex was extracted on the thin film of diisobutyl ketone (DIBK) on the inner wall of the PTFE extraction coil. The wetting-film with the extracted analyte was then eluted by a segment of the cover solvent, and transported directly to the FAAS for evaluation. All the important chemical and flow parameters were optimized. Under the optimized conditions an enhancement factor of 35, a sample frequency of 22 h−1 and a detection limit of cL = 0.7 μg l−1 Cd(II) were obtained for 60 s preconcentration time. The calibration curve was linear over the concentration range 1.5-45.0 μg l−1 Cd(II) and the relative standard deviation, R.S.D. (n = 10) was 3.9%, at 10.0 μg l−1 concentration level. The developed method was successfully applied to cadmium determination in a variety of environmental water samples as well as waste-water sample.  相似文献   

18.
A water-insoluble chelating material, p-dimethylaminobenzylidenerhodanine on silica gel (DMABR—SG) is described for preconcentration of trace amounts of silver(I), gold(III) and palladium(II) from water samples. Radioactive tracers (110mAg and 195Au) were used to study the behavior of silver and gold; palladium was monitored spectrophotometrically as its 1-(2-pyridylazo)naphthol complex in chloroform. In batch experiments, silver was quantitatively retained on the DMABR—SG at acidities ranging from 1.7 M to pH 5, and gold from 3 M to pH 5; equilibrium was achieved within 1 min for both elements. From sea water, silver ion was completely retained at pH 1.0–6.5 and gold ion at pH 1.0–3.5. In the case of palladium, shaking for about 20 min was required for quantitative retention at pH 1.0–5.0 for aqueous solution and at pH 1.0–7.0 for sea water. The chelating capacity of the DMABR—SG was 23 μmol Ag, 11 μmol Au and 11 μmol Pd per g. Quantitative recovery of silver and gold on DMABR—SG columns from sea water was achieved at higher flow rates (1–2 l h-1 and 2–3 l h-1, respectively) than with other chelating resins, e.g., Chelex 100, palladium required slower flow rate (150 ml h-1). Silver retained on the DMABR—SG column was completely eluted with 20 ml of 2.5% sodium thiosulfate solution but palladium remained on the column. Silver, gold and palladium were quantitatively eluted with 20 ml of 0.1% thiourea in 0.1 M hydrochloric acid.  相似文献   

19.
A simple and sensitive method has been developed for the trace determination of bismuth in aqueous samples by a combination of solid‐phase extraction and hydride generation atomic absorption spectrometry. The method is based on the use of a column packed with 2‐mercaptobenzothiazole immobilized on sodium dodecyl sulfate coated alumina. Different parameters influencing the separation and preconcentration of bismuth such as pH, sample volume, type, and concentration of eluent, and the flow rate of sample and eluent were studied. A sample volume of 500.0 mL resulted in a preconcentration factor of 100. The precision (relative standard deviation, N = 10) at the 300 ng/L level and the limit of detection (3s) were found to be 2.3% and 12 ng/L, respectively. The developed method was successfully applied to the determination of bismuth in natural water samples and two certified reference materials.  相似文献   

20.
A new, simple, fast and reliable solid-phase extraction method has been developed for separation/preconcentration of trace amounts of Pb(II) using dithizone/sodium dodecyl sulfate-immobilized on alumina-coated magnetite nanoparticles, and its determination by flame atomic absorption spectrometry (FAAS) and graphite furnace atomic absorption spectrometry (GFAAS) after eluting with 4.0?mol?L?1 HNO3. Optimal experimental conditions including pH, sample volume, eluent concentration and volume, and co-existing ions have been studied and established. Under the optimal experimental conditions, the preconcentration factor, detection limit, linear range and relative standard deviation of Pb(II) using FAAS technique were 280 (for 560?mL of sample solution), 0.28?ng?mL?1, 1.4?C70?ng?mL?1 and 4.6% (for 10?ng?mL?1, n?=?10), respectively. These analytical parameters using GFAAS technique were 300 (for 600?mL of sample solution), 0.002?ng?mL?1, 0.006?C13.2?ng?mL?1 and 3.1% (for 5?ng?mL?1, n?=?10), respectively. The presented procedure was successfully applied for determination of Pb(II) content in opium, heroin, lipstick, plants and water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号