首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Recent applications of microemulsion electrokinetic chromatography   总被引:1,自引:0,他引:1  
Huie CW 《Electrophoresis》2006,27(1):60-75
Compared to MEKC, the presence of a water-immiscible oil phase in the microemulsion droplets of microemulsion EKC (MEEKC) gives rise to some special properties, such as enhanced solubilization capacity and enlarged migration window, which could allow for the improved separation of various hydrophobic and hydrophilic compounds, with reduced sample pretreatment steps, unique selectivities and/or higher efficiencies. Typically, stable and optically clear oil-in-water microemulsions containing a surfactant (SDS), oil (octane or heptane), and cosurfactant (1-butanol) in phosphate buffer are employed as separation media in conventional MEEKC. However, in recent years, the applicability of reverse MEEKC (water-in-oil microemulsions) has also been demonstrated, such as for the enhanced separation of highly hydrophobic substances. Also, during the past few years, the development and application of MEEKC for the separation of chiral molecules has been expanded, based on the use of enantioselective microemulsions that contained a chiral surfactant or chiral alcohol. On the other hand, the application of MEEKC for the characterization of the lipophilicity of chemical substances remains an active and important area of research, such as the use of multiplex MEEKC for the high-throughput determination of partition coefficients (log P values) of pharmaceutical compounds. In this review, recent applications of MEEKC (covering the period from 2003 to 2005) are reported. Emphases are placed on the discussion of MEEKC in the separation of chiral molecules and highly hydrophobic substances, as well as in the determination of partition coefficients, followed by a survey of recent applications of MEEKC in the analysis of pharmaceuticals, cosmetics and health-care products, biological and environmental compounds, plant materials, and foods.  相似文献   

2.
微乳液毛细管电动色谱研究   总被引:2,自引:0,他引:2  
傅小芸  吕建德  竺安 《化学学报》1997,55(5):503-507
本文研究了两组混合样的微乳液毛细管电动色谱(MEEKC)分离, 较系统地研究了微乳液的内相, 助表面活性剂及其浓度对电动分离的迁移时间、柱效及时间窗的影响, 并与胶束毛细管电动色谱(MEKC)分离进行了比较, 选用由80mmol/L正辛烷-120mmol/L十二烷基硫酸钠-900mmol/L正丁醇-10mmol/L硼砂组成的微乳液, 样品组分电动色谱迁移时间的RSD<0.8%, 峰面积RSD<3.0%.  相似文献   

3.
In this study, separation and determination of nine preservatives ranging from hydrophilic to hydrophobic properties, which are commonly used as additives in various pharmaceutical and cosmetic products, by micellar electrokinetic chromatograpy (MEKC) and microemulsion electrokinetic chromatography (MEEKC) were compared. The effect of temperature, buffer pH, and concentration of surfactant on separation were examined. In MEKC, the separation resolution of preservatives improved markedly by changing the sodium dodecyl sulfate concentration. Temperature and pH of running buffers were used mainly to shorten the magnitude of separation time. However, in order to detect all preservatives in a single run in a MEEKC system, a microemulsion of higher pH was needed. The separation resolution was improved dramatically by changing temperature, and a higher concentration of SDS was necessary for maintaining a stable microemulsion solution, therefore the separation of the nine preservatives in MEEKC took longer than in MEKC. An optimum MEKC method for separation of the nine preservatives was obtained within 9.0 min with a running buffer of pH 9.0 containing 20 mM SDS at 25 degrees C. A separation with baseline resolution was also obtained within 16 min using a microemulsion of pH 9.5 which composed of SDS, 1-butanol, and octane, and a shorter capillary column at 34 degrees C. Finally, the developed MEKC and MEEKC methods determined successfully preservatives in various cosmetic and pharmaceutical products.  相似文献   

4.
A comparison between chiral cyclodextrin‐modified microemulsion electrokinetic chromatography (CD‐MEEKC) and cyclodextrin‐modified micellar electrokinetic chromatography (CD‐MEKC) for the enantiomeric separation of esbiothrin was carried out. For both methods, the separation conditions were optimized by varying CD types and concentration, running buffer pH and compositions, organic modifiers, and temperature. The optimal CD‐MEEKC conditions were 0.8% n‐heptane, 2.3% SDS, 6.6% n‐butanol, 90.3% 10 mM sodium tetraborate containing 3% (w/v, the ratio of CD mass to microemulsion volume) methyl‐β‐cyclodextrin, pH 10, 25°C. The optimized CD‐MEKC conditions were 3.3% SDS, 96.7% 10 mM sodium tetraborate containing 5% (w/v) β‐CD, pH 10, 25°C. The difference in physicochemical properties of the buffer and CDs resulted in different optimal CD type. The competitive distribution between the microemulsion (or micelle) and chiral CD contributed to the chiral separation. Both methods provided excellent separation (Rs ~? 3) with similar migration time (ca. 15 min). CD‐MEEKC provided higher separation efficiencies (>300000) than CD‐MEKC (>200000). The LODs for CD‐MEEKC and CD‐MEKC were 4.7 μg/mL and 3.2 μg/mL, respectively. The RSDs of migration time and peak area for CD‐MEEKC were slightly higher than for CD‐MEKC. Both the demonstrated CD‐MEEKC and CD‐MEKC methods provided high efficiencies, low LODs, and reproducible enantioseparations of esbiothrin.  相似文献   

5.
Wu CH  Chen TH  Huang KP  Wang GR  Liu CY 《Electrophoresis》2007,28(20):3691-3696
A novel microemulsion based on a mixture of diethyl L-tartrate (DET) and SDS was developed for the microemulsion EKC (MEEKC) determination of structurally related steroids. The system consisted of 0.5% w/w DET, 1.7% w/w SDS, 1.2% w/w 1-butanol, 89.6% w/w phosphate buffer (40 mM, pH 7.0), and 7% w/w ACN. With an applied voltage of +10 kV, a baseline separation of aldosterone (A), cortisone acetate (CA), dexamethasone (D), hydrocortisone (H), hydrocortisone acetate (HA), prednisolone (P), prednisolone acetate (PA), prednisone (Ps), triamcinolone (T), and triamcinolone acetonide (TA) could be achieved. Under the optimized conditions, the reproducibility of the retention time (n = 4) for most of the compounds was less than +/-0.8% with the exception of A, Ps, and T. The average number of theoretical plates was 18 800 plates/m. The results were compared with those achieved by the modified micellar EKC (MEKC). MEEKC showed obvious advantages over MEKC for the separation of highly hydrophobic substances. To further evaluate the system, we tested the MEEKC method by analyzing corticosteroids in a spiked urine sample.  相似文献   

6.
The migration behaviour of isoquinoline, quinoline, and methyl derivatives of quinoline in different capillary electrophoretic modes has been systematically investigated. Optimised separation conditions were established by varying the key parameters (solvent, pH, temperature, surfactant concentration, core phase) for aqueous and non‐aqueous capillary zone electrophoresis (NACE), micellar electrokinetic chromatography (MEKC) with anionic or non‐ionic micelles (SDS, Brij 35), and microemulsion electrokinetic chromatography (MEEKC) with charged or uncharged microemulsion droplets. A separation of all quinolines could be achieved by MEEKC with charged droplets, by MEKC or by formamide‐based NACE. Comparing the separations with respect to separation selectivity, substantial changes in migration order could be observed between the different techniques. Regarding separation efficiency, the number of theoretical plates and limits of detection (LOD) have been compared. The best LODs were achieved using SDS as surfactant in MEKC, followed by MEEKC.  相似文献   

7.
Micellar electrokinetic chromatography (MEKC) and microemulsion electrokinetic chromatography (MEEKC) are two kinds of electrokinetic capillary chromatography (EKC), which are characterized of high solubilization capacity and separation efficiency. In our previous work, some polar organic compounds and hydrophobic neutral compounds were separated successfully by EKC1-3. In this paper, these methods were used for separating six pyridoncarboylxic acid derivatives with similar structures. T…  相似文献   

8.
Zheng ZX  Lin JM  Chan WH  Lee AW  Huie CW 《Electrophoresis》2004,25(18-19):3263-3269
A novel chiral microemulsion, which involved the use of chiral alcohols as cosurfactants, was demonstrated for the enantiomeric separation of a number of pharmaceutical drugs in microemulsion electrokinetic chromatography (MEEKC). The chiral alcohols investigated were optically active 2-alkanols, with the alkyl chain length having carbon number ranging from 4 to 7. The data indicated that, except for R-(-)-2-butanol, the use of R-(-)-2-pentanol, R-(-)-2-hexanol or R-(-)-2-heptanol as the chiral cosurfactant resulted in the baseline or partial resolution of most of the test solutes, i.e., (+/-)-norephedrine, (+/-)-ephedrine, DL-nadolol, and DL-propranolol. In addition to the chain length of the chiral 2-alkanols, the effects of other experimental conditions, such as the concentration and chirality of the 2-alkanols, as well as the pH of the run buffer and the oil phase of the microemulsion, on the enantiomeric separation of the test solutes were also investigated. An interesting finding was that the water-immiscible organic solvent (oil core) within the microemulsion droplets appeared to play an important role in the chiral separation mechanism. Also, the importance of hydrogen bonding between the test solutes ((+/-)-ephedrine and related compounds) and the chiral microemulsion was demonstrated, as it was not possible to resolve a pair of enantiomers which lacked a beta-amino proton (i.e., (+/-)-N-methyl ephedrine) under optimized run buffer conditions (e.g., 5.0% R-(-)-2-hexanol, 0.8% n-octane, and 3.5% SDS in 90.7% borate buffer at pH 9.2).  相似文献   

9.
Li Q  Chang CK  Huie CW 《Electrophoresis》2005,26(17):3349-3359
The effects of organic solvents on the capillary electrophoresis (CE) separation of a number of important biological porphyrin methyl esters - six weakly basic, hydrophobic cyclic tetrapyrroles possessing two and four to eight methyl ester groups around the periphery of the porphyrin ring - were investigated in the mode of micellar electrokinetic chromatography (MEKC), microemulsion electrokinetic chromatography (MEEKC), and nonaqueous CE. In aqueous MEKC, partial separation of the six neutral porphyrin methyl esters was obtained with an organic modifier (acetonitrile) in the concentration range between 20 and 40%, in which sodium dodecyl sulfate (SDS) molecules might be present in the form of SDS micelles and/or SDS micelle-like aggregates. Relatively stable SDS micelles can be formed in nonaqueous MEKC using formamide as the separation medium, but the separation of the target analytes remained unsatisfactory. Improved resolution of all six porphyrin methyl esters was obtained using MEEKC with the running buffer consisting of 0.8% w/w n-heptane (oil phase), 2.25% w/w SDS and 1.0% w/w Brij 35 (mixed surfactant), 6.6% w/w 1-butanol (cosurfactant), and 30% v/v 2-propanol (second cosurfactant), but reproducibility in terms of peak areas for certain porphyrins (especially uroporphyrin I octamethyl ester) was found to be very poor. Best separation performances were achieved with nonaqueous CE separations in which the weakly basic porphyrin methyl esters were protonated under strongly acidic conditions (e.g., using 10 mM perchloric acid) in mixed organic solvents. For example, using a 50:50 mixture of methanol and acetonitrile as the separation medium, baseline separation of all six (positively charged) porphyrin methyl esters can be obtained within 3 min and the average precision (RSD, N = 13) in terms of migration time and peak area were 0.55 and 2.16%, respectively.  相似文献   

10.
Cao Y  Ni X  Sheng J 《Journal of chromatography. A》2011,1218(18):2598-2603
Recently, 1-butanol modified MEKC was proven to be similar to MEEKC in separation performance. In the present work, typical microemulsion containing 0.8% n-octane/3.3% SDS/6.6% 1-butanol/20 mM borax buffer and corresponding swollen micelle without n-octane were used to compare their microdroplet structures including hydrodynamic radius, electrokinetic potential ζ and charge density at the hydrodynamic shear surface, as well as microenvironment polarity in the interior of the microdroplets. Three kinds of corticosteroids were separated with MEEKC and 1-butanol modified MEKC to assess their separation performances. The experiment results showed that both microstructure and separation performance in microemulsion and in swollen micelle systems were alike, no matter whether oil phase n-octane was present. The environment polarity in the core of swollen micelle was slightly higher than in the microemulsions, and both of them were higher than in n-octane medium. Furthermore, the influences of SDS and 1-butanol concentration on microstructures were measured in details. Increasing the amount of SDS, hydrodynamic radius decreased in microemulsion but increased in swollen micelle. On the contrary, ζ and shear surface charge density changed in the reverse trends. With increment of 1-butanol concentration, the hydrodynamic radius increased dramatically in microemulsions, whereas decreased slightly in swollen micelle. Even though using n-octane as oil core was not a key factor, microemulsions and swollen micelle as pseudostationary phase in EKC should not be exactly the same.  相似文献   

11.
Based on the investigation of the effect of microemulsion charge on the chiral separation, a new chiral separation method with MEEKC employing neutral microemulsion was established. The method used a microemulsion containing 3.0% (w/v) neutral surfactant Tween 20 and 0.8% (w/v, 30 mM) dibutyl l ‐tartrate in 40 mM sodium tetraborate buffer to separate the enantiomers of β‐blockers. The effect of major parameters on the chiral separation was investigated. The applied voltage had little effect on the resolution, but the chiral separation could be improved by suppressing the EOF. Nine racemic β‐blockers obtained relatively good enantioseparation after appropriate concentrations of tetradecyl trimethyl ammonium bromide were added into the microemulsion to suppress the EOF. These results were explained based on the analysis of the separation mechanism of the method and deduced separation equations. The resolution equation of the method was further elucidated. It was found that the fourth term in the resolution equation, an additional term compared to the conventional resolution equation for column chromatography, represents the ratio of the relative movement distance between the analyte and microemulsion droplets relative to the effective capillary length. It can be regarded as a correction for the effective capillary length. These findings are significant for the development of the theory of MEEKC and the development of new chiral MEEKC method.  相似文献   

12.
Micellar electrokinetic chromatography (MEKC) was investigated for the enantiomeric separations of three binaphthyl derivatives ((+/-)-1,1'-bi-(2-naphthol) (BOH), (+/-)-1,1'-binaphthyl-2,2'-diyl hydrogenphosphate (BNP), and (+/-)-1,1'-binaphthyl-2,2'-diamine (BNA)) using two recently synthesized chiral polymeric surfactants (polysodium N-undecenoxy carbonyl-L-leucinate (poly-L-SUCL) and polysodium N-undecenoxy carbonyl-L-isoleucinate (poly-L-SUCIL)) in our laboratory. Enantiomeric separation (resolution and selectivity) of the binaphthyl derivatives was influenced by polymerization concentration of the monomeric surfactant, pH, type and concentration of the background electrolyte (BGE) as well as concentration of the polymeric surfactant. Two BGEs (dibasic phosphate and Tris-borate) were compared for this study. The use of dibasic phosphate as BGE in poly-L-SUCL provides baseline resolution of (+/-) BOH and (+/-) BNP, however, no resolution and selectivity at all was observed for (+/-) BNA. A similar approach was adopted with Tris-borate-poly-L-SUCL system at fixed pH 10.1, which resulted in baseline resolution of all three binaphthyl derivatives. Although R(s) of binaphthyl derivatives was always higher and electroosmotic flow (EOF) was always lower using Tris-borate than with dibasic phosphate, the selectivity values for the two buffer systems did not differ significantly. In addition, it was found that poly-L-SUCL provided better enantiomeric resolution and selectivity for (+/-) BOH and (+/-) BNA, while poly-L-SUCIL provided enhanced enantiomeric resolution but similar enantioselectivity for (+/-) BNP. This indicates that the depth of analyte penetration into the palisade layer and the micellar core are responsible for chiral recognition of hydrophobic analyte (e.g., (+/-) BOH, and (+/-) BNA) whereas for moderately hydrophobic analyte (e.g., (+/-) BNP) interaction with the polar head group seems to dictate chiral recognition. Simultaneous enantioresolution of all three binaphthyl derivatives was possible in a single electrophoretic run using either poly-L-SUCL or poly-L-SUCIL. Further comparison of the two polymeric surfactants showed that poly-L-SUCL provided slightly longer analysis time than poly-L-SUCIL but the use of the former polymeric surfactant should be preferred due to its ability to provide complete baseline resolution and higher selectivity of all the three atropisomers with a wider chiral window.  相似文献   

13.
Yang X  Xia Y  Tao C  Liao Y  Zuo Y  Liu H 《Electrophoresis》2007,28(11):1744-1751
An investigation of the basic factors which govern the microemulsion EKC (MEEKC) and MEKC for the separation of four benzoylurea (BU) insecticides and their four analogs was carried out. In MEEKC, the separation of eight BU compounds was optimized by changing the microemulsion composition, such as concentration of SDS, octane, n-butanol, and isopropanol percentages, as well as capillary temperature. Separation optimization was also carried out for MEKC, showing that ACN and a high level of another additive gamma-CD were needed to achieve effective separation of these analytes. Although separation with baseline resolution was achieved by either MEEKC or MEKC methods, the separation selectivity resulting from the proposed MEEKC method was completely different from that of MEKC. In addition, analytical time in MEEKC was longer than that in MEKC, but in view of theoretical plate numbers, detection limits, and reproducibility, both methods were effective for the analysis of BU insecticides and their analogs.  相似文献   

14.
The enantiomeric separation of basic drugs was successfully demonstrated by using a novel chiral microemulsion electrokinetic chromatography (MEEKC). An interesting finding was that the chiral oil core ((S)-(+)-2-octanol) within the microemulsion droplets appeared to play an important role in the chiral separation mechanism. In addition, the enantioselectivity of the analyte-selector complex could be influenced by methanol, through an interaction with the complex. The chiral resolution (R(s)) and partition coefficient were strongly influenced by the concentration of methanol, pH, the concentration of chiral oil and the concentration of a cosurfactant. Under the optimized microemulsion conditions, the baseline separation of (+/-)-ephedrine (R(s) = 2.7), and the partial separations of (+/-)-norephedrine (R(s) = 1.3), (+/-)-synephrine (R(s) = 1.4) and (+/-)-propranolol (R(s) = 1.3), could be achieved.  相似文献   

15.
Microemulsion electrokinetic chromatography (MEEKC) has been applied to the separation of some phenolic antioxidants [Irganox 1024, Irganox 1035, Irganox 1076, Irganox 1010, Irganox 1330, Irgafos 138, Irganox 168 and 2,6-di-tert.-butyl-4-methylphenol (BHT)]. Due to the extremely hydrophobic nature of these analytes, they could not be separated using standard MEEKC conditions and two alternative approaches were investigated. Using an acidic buffer (phosphate, pH 2.5) to effectively suppress the electroosmotic flow, the addition of 2-propanol to the aqueous phase of the microemulsion buffer to improve partitioning of the analytes, and a negative separation voltage, separation of five of the analytes in under 10 min was possible. The second approach, using a basic buffer (borate, pH 9.2) and a positive separation voltage resulted in complete resolution of all eight analytes. A mixed surfactant system comprising the anionic sodium dodecyl sulfate (SDS) and neutral Brij 35 was used to reduce the overall charge and with it the mobility of the droplets, and hence the separation time. Using an optimised MEEKC buffer consisting of 2.25% (w/w) SDS, 0.75% (w/w) Brij 35, 0.8% (w/w) n-octane, 6.6% (w/w) 1-butanol, 25% (w/w) 2-propanol and 64.6% (w/w) 10 mM borate buffer (pH 9.2) the eight target analytes were baseline separated in under 25 min. For these analytes, MEEKC was found to be superior to micellar electrokinetic chromatography in every respect. Specifically, the solubility of the analytes was better, the selectivity was more favourable, the analysis time was shorter and the separation efficiency was up to 72% higher when using the MEEKC method. Detection limits from 5.4 to 26 microg/ml were obtained and the calibration plot was linear over more than one order of magnitude. The optimised method could be applied to the determination of Irganox 1330 and Irganox 1010 in polypropylene.  相似文献   

16.
Kahle KA  Foley JP 《Electrophoresis》2006,27(4):896-904
In this study, the combination of two chiral components in a microemulsion formulation for the separation of enantiomers via microemulsion EKC (MEEKC) was successfully accomplished. Previous publications of chiral microemulsions have utilized only one chiral entity; the surfactant, cosurfactant, or oil was chiral. This is the first study, to date, of the effects of using two chiral species in a single pseudostationary phase (PSP). The chiral surfactant dodecoxycarbonylvaline (DDCV) was used in conjunction with the chiral cosurfactant S-2-hexanol. Ethyl acetate was incorporated as the oil core of the microemulsion and the buffer was 50 mM phosphate at a pH of 7. Additionally, a microemulsion prepared with racemic 2-hexanol was used for comparison to a previous DDCV microemulsion and as a baseline for the newly formulated dual chiral microemulsion. The efficiencies, resolutions, and enantioselectivities for the S-2-hexanol, racemic 2-hexanol, and original 1-butanol DDCV microemulsions are compared. The hexanol-based PSPs provide improved efficiencies and resolutions. To evaluate the combination of each DDCV enantiomer (R and S) with S-2-hexanol, changes in Gibb's free energy were calculated. A synergistic effect was found when two chiral components were combined to form a microemulsion.  相似文献   

17.
In this study, microemulsion electrokinetic chromatography (MEEKC) and micellar electrokinetic chromatography (MEKC) were compared for their abilities to separate and detect thirteen phenolic compounds (syringic acid, p-coumaric acid, vanillic acid, caffeic acid, gallic acid, 3,4-dihydroxybenzoic acid, 4-hydroxybenzoic acid, (+)-catechin, (-)-epigallocatechin, (-)-epicatechin gallate, (-)-epigallocatechin gallate, (-)-epicatechin, and (-)-gallocatechin), and two other ingredients (caffeine and theophylline) in teas and grapes. Separation of phenolic compounds was improved by changing the SDS concentration for MEEKC, but the SDS concentration rarely affected the resolution for MEKC. Organic modifier (acetonitrile or methanol) was found to markedly influence the resolution and selectivity for both MEEKC and MEKC systems. In addition, a higher voltage and a higher column temperature improved the separation efficiency without any noticeable reduction in resolution for MEEKC whereas they caused a poor resolution for the MEKC system. Although separations with baseline resolution were achieved by the optimized MEEKC and MEKC methods, the separation selectivity resulting from the proposed MEEKC method was completely different from that of MEKC.  相似文献   

18.
彭振磊  林金明 《色谱》2009,27(5):621-630
近年来毛细管微乳电动色谱(MEEKC)研究的范围不断扩大,其分离分析的化合物类型也不断增多。该文综述了2002年以来MEEKC应用的研究进展,指出了目前MEEKC研究中存在的一些问题,对今后的研究发展方向进行了展望。  相似文献   

19.
A microemulsion electrokinetic chromatography (MEEKC) method was developed to analyze and detect eight food colorants (tartrazine, fast green FCF, brilliant blue FCF, allura red AC, indigo carmine, sunset yellow FCF, new coccine, and carminic acid), which are commonly used as food additives in various food products. The effects of sodium dodecyl sulfate (SDS) surfactant, organic modifier, cosurfactant, and oil were examined in order to optimize the separation. The amount of organic modifier (acetonitrile) and SDS surfactant were determined as apparent influences on the separation resolution while the type of oil and cosurfactant rarely affected the separation selectivity of the eight colorants. A highly efficient MEEKC separation method, where the eight colorants were separated with baseline resolution within 14 min, was achieved by using a microemulsion solution of pH 2.0 containing 3.31% SDS, 0.81% octane, 6.61% 1-butanol, and 10% acetonitrile. This optimal MEEKC method has a higher separation efficiency and similar detection limit when compared to conventional capillary electrophoresis (CE) method. Furthermore, a sample pretreatment is rarely needed when this MEEKC technique is used to analyze colorants in food products, whereas a suitable sample pretreatment (for example solid-phase extraction) has to be employed prior to CE separation in order to eliminate matrix interferences resulting from the constituents of the food sample.  相似文献   

20.
The electrophoretic behaviors of five bases and corresponding nucleosides in the oil in water (o/w) microemulsion capillary electrophoresis, microemulsion electrokinetic chromatography (MEEKC), were examined in comparison with those in normal capillary zone electrophoresis (CZE). The microemulsion systems were composed of heptane, sodium dodecyl sulfate (SDS), 1-butanol and 10 mM phosphate buffer (pH 7.0) or toluene, SDS, 1-butanol and 5 mM carbonate buffer (pH 10.0). CZE was carried out in the range of pH 9.7-10.9, and the dissociation constants, pKa, of the bases and nucleosides and the electrophoretic mobilities of the anionic forms were determined. The electrophoretic behaviors of the solutes in the microemulsion systems were analyzed from their pKa, the electrophoretic mobilities of the anions determined by CZE, and the distribution constants, K(D), of the neutral forms between the microemulsion droplets and the outer aqueous phase. The importance of adsorption mechanism in MEEKC system was suggested from the correlation between log K(D) and log P.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号