首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
K-shell x-ray spectroscopy of sub-100 nm Al foils irradiated by high contrast, spatially uniform, 150 fs, Ilambda (2)=2 x 10(18) W microm(2)/cm(2), laser pulses is obtained with 500 fs time resolution. Two distinct phases occur: At /=500 fs the resonance transitions dominate. Initial satellites arise from a large area, high density, low temperature (approximately 100 eV) plasma created by fast electrons. Thus, contrary to predictions, a short, high intensity laser incident on a thin foil does not create a uniform, hot dense plasma.  相似文献   

2.
The energy distributions of beam electrons and x-ray photons in a volume nanosecond discharge on atmospheric-pressure air are studied. Several groups of elevated-energy electrons are found. It is shown that electrons with an energy from several tens to several hundreds of kiloelectronvolts (which is lower than a maximal voltage across the gap) make a major contribution to the beam current measured behind thin foils. It is corroborated that fast electrons (with an energy from several kiloelectronvolts to several tens of kiloelectron-volts) arise 100–150 ps before the basic peak of the beam current, elongating the current pulse and significantly increasing its amplitude. The contribution from electrons with an anomalously high energy (exceeding a maximal voltage across the gap) to the beam current is shown to be insignificant (less than 5%). The x-ray spectra in gas-filled diodes of different design are studied. Techniques of measuring the subnanosecond electron beam current and mechanisms generating fast and runaway electrons in volume high-pressure gas discharges are analyzed.  相似文献   

3.
We report on generation of coherent optical phonon oscillations in 150 microm thick bulk GaN. With photon energy far below the band gap, the generation mechanisms of coherent phonon modes of A1(LO), high- and low-frequency E2 are revealed to be the impulsive stimulated Raman scattering. We find that one among the two degenerate E2 modes is selectively detected with a proper choice of probe polarization. Dephasing times range from 1.5 to 70 ps for different modes, and phonon-three-photon absorbed carrier interactions are compared between the A1(LO) and the E2 mode.  相似文献   

4.
A commercial rheometer (Bohlin CVO120) was used to mechanically test materials that approximate vocal-fold tissues. Application is to frequencies in the low audio range (20-150 Hz). Because commercial rheometers are not specifically designed for this frequency range, a primary problem is maintaining accuracy up to (and beyond) the mechanical resonance frequency of the rotating shaft assembly. A standard viscoelastic material (NIST SRM 2490) has been used to calibrate the rheometric system for an expanded frequency range. Mathematically predicted response curves are compared to measured response curves, and an error analysis is conducted to determine the accuracy to which the elastic modulus and the shear modulus can be determined in the 20-150-Hz region. Results indicate that the inertia of the rotating assembly and the gap between the plates need to be known (or determined empirically) to a high precision when the measurement frequency exceeds the resonant frequency. In addition, a phase correction is needed to account for the magnetic inertia (inductance) of the drag cup motor. Uncorrected, the measured phase can go below the theoretical limit of -pi. This can produce large errors in the viscous modulus near and above the resonance frequency. With appropriate inertia and phase corrections, +/- 10% accuracy can be obtained up to twice the resonance frequency.  相似文献   

5.
Sun L  Hesselink L 《Optics letters》2006,31(24):3606-3608
We present a design of a linear optical waveguide that utilizes a C-shaped metallic nano-aperture that efficiently transports light while maintaining a spot size of lambda/10. The performance of a C-aperture waveguide is superior to both a regular ridge waveguide and other surface plasmon based metal nano-optical waveguides. The energy transport mechanisms are explained by the coupling of an aperture surface resonance and the thickness resonances inside the guide channel. Finite-difference time-domain simulations of gold C-aperture waveguides are performed for a 1.5 microm wavelength incident plane wave. The 1/e decay length in power transmission is predicted to be approximately 2.5 microm. The total power throughput is 1.66 for the 2.55 microm long guide, with an intensity 6 times that of the incident wave at a distance 120 nm from the exit plane, having a spot size of 150 nm.  相似文献   

6.
The coherent response of a polarizable medium to the radiation stimulated by the interaction of an incident coherent electromagnetic wave with a charged-particle beam, moving with greater than critical speed, results in intense electromagnetic radiation in the form of one or more shock fronts. The shock frequencies are shifted significantly from that of the incident wave and are tunable by parametric variation of the incident beams. The mechanism for this new effect (SESR) differs fundamentally from the laser mechanism. Production of intense quasi-coherent x-ray radiation by SESR obviates the need for x-ray mirrors and is not inhibited by the large spontaneous emission rates at these frequencies. Substantial fraction of the particle-beam energy can be converted into frequency-shifted radiation, with intensity larger than that of the incident wave, because of quadratic dependence on the interaction distance in the medium of the energy radiated into SESR, as compared to the linear dependence of Cerenkov radiative energy. Specific shock frequencies cross from below to above a given resonance frequency of the medium as the relevant two level populations become inverted. This dynamical dependence of the shock frequencies on the level populations provides the basis for new pumping and amplification mechanisms. An example of a possible SESR-based transducing-amplification system is described.  相似文献   

7.
We demonstrate that betatron x-ray radiation accurately provides direct imaging of electrons trajectories accelerated in laser wakefields. Experimental far field x-ray beam profiles reveal that electrons can follow similar transverse trajectories with typical excursions of 1.5 microm+/-0.5 microm in the plane of laser polarization and 0.7 microm+/-0.2 microm in the plane perpendicular.  相似文献   

8.
A new photon-in/photon-out endstation at beamline 02B02 of the Shanghai Synchrotron Radiation Facility for studying the electronic structure of energy materials has been constructed and fully opened to users. The endstation has the capability to perform soft x-ray absorption spectroscopy in total electron yield and total fluorescence yield modes simultaneously. The photon energy ranges from 40 eV to 2000 eV covering the K-edge of most low Z-elements and the L-edge of 3d transition-metals. The new self-designed channeltron detector allows us to achieve good fluorescence signals at the low photon flux. In addition, we synchronously collect the signals of a standard reference sample and a gold mesh on the upstream to calibrate the photon energy and monitor the beam fluctuation, respectively. In order to cross the pressure gap,in situ gas and liquid cells for soft x-ray absorption spectroscopy are developed to study the samples under realistic working conditions.  相似文献   

9.
Accurate prediction of the energy propagation direction and the associated lateral shift is very important for the design of efficient energy conversion devices and sensors based on nanoscale thermal radiation. This paper concerns the direction of energy flow during near-field radiative transfer between two parallel plates separated by a vacuum gap. An improved formulation, fully consistent with fluctuational electrodynamics, is developed to correctly trace the energy streamlines inside the emitter, receiver, and the vacuum gap. The influence of surface waves on the direction of energy propagation as well as on the lateral shift of energy streamlines is elucidated. An important finding with the improved formulation is that the lateral shift in the emitter may exceed that in the vacuum gap. The method can be extended for tracing the energy streamlines in multilayered structures.  相似文献   

10.
The effects of anomalous dispersion (resonance) on multiple reflection of x rays and their interference in crystals at atomic absorption edges are studied. Intensity ratios of two inversion-symmetry-related multiple diffractions at or near absorption edges exhibit highly phase-sensitive profiles with strong asymmetric characteristics, unlike those far from the edges. A new resonance perturbation Bethe approach is developed to explain this behavior. This leads to direct determination of the phase change for x-ray reflections at resonance.  相似文献   

11.
声波在一维声子晶体中共振隧穿的研究   总被引:22,自引:0,他引:22       下载免费PDF全文
通过从实验和理论方面对声波在一维声子晶体单晶体和被小的共振腔分开的双晶体中传播时发生的隧穿和共振隧穿现象的研究,观察到了声子晶体单晶体在带隙频率范围内发生的隧穿现象,而对于双晶体样品,在带隙频率范围内出现了很强的共振透射峰.共振发生时,实验测得的群时间很大,但是没有共振时,群速度却很快. 关键词: 声波 声子晶体 隧穿 共振  相似文献   

12.
秦立振  张振宇  张坤  丁建桥  段智勇  苏宇锋 《物理学报》2018,67(1):18501-018501
分析了微型抗磁悬浮振动能量采集器中悬浮磁体的受力特性,发现了能量采集器的单稳态和双稳态现象,研究了能量采集器在不同工作状态下该两种稳态类型时的动力学响应特性.当能量采集器处于非工作的单稳态状态时,其动力学响应是在线性系统的基础上加入非线性扰动、幅频响应曲线向右偏转;热解石墨板间距越大,非线性扰动越强烈,右偏现象则越显著.当能量采集器处于非工作的双稳态状态时,其动力学响应比较复杂,出现倍周期、4倍周期以及混沌等非线性系统特有的现象.当能量采集器处于工作状态的双稳态状态时,其振动频率和外界激励频率保持一致,进行周期振动.该研究对抗磁悬浮振动能量采集器的结构设计具有重要的参考价值,为提高能量采集器的响应特性和输出性能提供了理论指导.  相似文献   

13.
Kalpha x-ray emission, extreme ultraviolet emission, and plasma imaging techniques have been used to diagnose energy transport patterns in copper foils ranging in thickness from 5 to 75 microm for intensities up to 5x10(20) W cm-2. The Kalpha emission and shadowgrams both indicate a larger divergence angle than that reported in the literature at lower intensities [R. Stephens, Phys. Rev. E 69, 066414 (2004)]. Foils 5 microm thick show triple-humped plasma expansion patterns at the back and front surfaces. Hybrid code modeling shows that this can be attributed to an increase in the mean energy of the fast electrons emitted at large radii, which only have sufficient energy to form a plasma in such thin targets.  相似文献   

14.
结合物理光学原理和表面等离子体共振(SPR)角度传感器,提出了可以突破衍射极限的纳米间距检测方法。在理论上建立起纳米间距和位相改变量之间的函数关系,借助于SPR角度传感器的高灵敏性,提出通过检测出射光束振动方向的p分量和s分量的位相差值来实现纳米间距的实时检测。模拟结果显示:纳米间距改变量从-0.5~0.5μm变化时,位相改变量可实现-150°~150°的变化,检测灵敏度〉1 nm。该检测方法能够实现10 nm以下间距的灵敏检测,且具有结构简单,易于操作,实时检测的特点。  相似文献   

15.
The femtosecond dissociation of HCl after core excitation has been studied through the resonant Auger decay. The spectra contain contributions from decay occurring at both "molecular" and "atomic" internuclear distances. We have observed a new interference mechanism in these spectra: An atomic spectral line develops into a negative spectral contribution, a "hole," when detuning the excitation energy from the maximum of the Cl2p(-1)sigma(*) resonance. Resonant x-ray scattering theory quantitatively explains this behavior as due to a novel destructive continuum-continuum interference between molecular and atomic contributions to the Auger decay.  相似文献   

16.
Magnetic resonance imaging (MRI) is very useful spectroscopy to visualize a three-dimensional (3D) real structure inside the sample without physical destruction. The spatial resolution of the readily available MRI spectrometer is, however, limited by a few ten to hundreds of microns due to a technological boundary of generating larger magnetic field gradient and to the insensitivity inherent to the inductive signal detection. Magnetic resonance force microscopy (MRFM) is new alternative MRI spectroscopy which is anticipated to significantly surpass the conventional MRI in both resolution and sensitivity. We report two imaging experiments on our MRFM spectrometer operated at room temperature and in vacuum approximately 10(-3)Pa. One is for approximately 20 microm liposome membrane labeled entirely by a nitroxide imaging agent and the other for approximately 15 microm DPPH particles, both are nearly the same size as that of human cell. The reconstructed images at spatial resolution approximately 1 microm were in satisfactory agreement with the scanning electron microscope images. The potential capability of visualizing intrinsic radicals in the cell is suggested to investigate redox process from a microscopic point of view.  相似文献   

17.
A system of two different isotropic dielectric plates aligned parallel to each other and separated by a gap is considered. For a sufficiently large gap, electromagnetic eigenwaves in the plates are virtually independent and dispersion curves for the studied system are characterized by an infinite set of intersections. A decrease in the gap thickness leads to coupling between the wave fields and the disappearance of the intersection points due to divergence of the dispersion curves. Each of the dispersion curves of the spectrum transformed under the action of coupling is formed by a set of adjacent portions of initially independent branches corresponding to different plates. A gradual change in the frequency along one of the new dispersion curves results in a periodic displacement of the localization zone of the wave field from one plate to the other.  相似文献   

18.
Quantized vortices with half-integer circulation, which are forbidden from existing in a conventional superfluid because of the single valueness of the wave function, are theoretically predicted to exist in superfluid 3He-A if the order parameters l over and d over form l over perpendicular d over texture. To form the l over perpendicular d over texture, we confined the superfluid between parallel plates with a 12.5 microm gap and applied a magnetic field of H=26.7 mT perpendicular to the plates to take NMR and orient d over perpendicular to l over. NMR spectra exhibit a negative-shift peak which probes that the uniform l over perpendicular d over texture is realized in our cell and show a new satellite signal under rotation. The rotation dependence of the satellite signal is interpreted that a Fréedericksz transition of l over texture is induced by rotation above 1.0 rad/s and vortices start to appear above 1.8 rad/s.  相似文献   

19.
PETRA II, a 12 GeV accelerator at DESY, Hamburg, is used to produce synchrotron radiation (SR) for experiments in the hard X-ray regime when it is not running as injector for HERA. The beam from an undulator is split by a diamond crystal in Laue geometry to feed two experimental stations, one of which is now dedicated for nuclear resonance experiments. The X-ray energy may be chosen in the range from 5 to 55 keV covering all isotopes already observed with SR and many interesting candidates for new resonances. Tuning may be performed by optimising the magnetic gap and the storage ring energy. In particular, the opportunities for timing experiments are unique due to a very flexible filling mode of the storage ring. The flux at the sample position is comparable to undulator beams at ESRF. The second beamline covers higher energies up to some 300 keV and may also be used for nuclear resonance experiments. This revised version was published online in August 2006 with corrections to the Cover Date.  相似文献   

20.
High resolution Fresnel zone plates for nanoscale three-dimensional imaging of materials by both soft and hard x-rays are increasingly needed by the broad applications in nanoscience and nanotechnology.When the outmost zone-width is shrinking down to 50 nm or even below,patterning the zone plates with high aspect ratio by electron beam lithography still remains a challenge because of the proximity effect.The uneven charge distribution in the exposed resist is still frequently observed even after standard proximity effect correction(PEC),because of the large variety in the line width.This work develops a new strategy,nicknamed as local proximity effect correction(LPEC),efficiently modifying the deposited energy over the whole zone plate on the top of proximity effect correction.By this way,50 nm zone plates with the aspect ratio from 4:1 up to 15:1 and the duty cycle close to 0.5 have been fabricated.Their imaging capability in soft(1.3 keV)and hard(9 keV)x-ray,respectively,has been demonstrated in Shanghai Synchrotron Radiation Facility(SSRF)with the resolution of 50 nm.The local proximity effect correction developed in this work should also be generally significant for the generation of zone plates with high resolutions beyond 50 nm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号