首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A small-sized surface plasmon resonance (SPR) sensor with a microchip flow cell has been developed for the purpose of enhancing the sensitivity of the SPR detector for low molecular weight compounds. This portable differential SPR detector consisted of an LED, two cylindrical lenses, a round prism, a divided mirror, a CCD, electronics, and a polydimethylsiloxane/gold microchip with two flow paths (10 mm long, 1 mm wide, 20-100 μm deep). 3-Mercaptopropyltrimethoxysilane was used for sealing the microchip. The performance of the on-site orientated SPR detector was estimated using sucrose and IgA. A drastic change in the SPR intensity appeared. The depth of the flow cell was in inverse proportion to the SPR intensity. Compared to a conventional flow cell having the size of 10 mm (L) × 1 mm (W) × 1 mm (D), its sensitivity to 10% sucrose and 0.9 nM IgA increased about 11 and 39 times, respectively. This phenomenon seemed to be due to the increase in the substance on the SPR sensor based on its size effect. These results showed that the application of the microchip sensor for SPR measurement has the possibility for improvement of the SPR intensity for low molecular substances.  相似文献   

2.
In this work, a new type of miniaturized fibre-coupled solid-state light source is demonstrated as an excitation source for fluorescence detection in capillary electrophoresis. It is based on a parabolically shaped micro-light emitting diode (μ-LED) array with a custom band-pass optical interference filter (IF) deposited at the back of the LED substrate. The GaN μ-LED array consisted of 270 individual μ-LED elements with a peak emission at 470 nm, each about 14 μm in diameter and operated as a single unit. Light was extracted through the transparent substrate material, and coupled to an optical fibre (OF, 400 μm in diameter, numerical aperture NA = 0.37), to form an integrated μ-LED-IF-OF light source component. This packaged μ-LED-IF-OF light source emitted approximately 225 μW of optical power at a bias current of 20 mA. The bandpass IF filter was designed to reduce undesirable LED light emissions in the wavelength range above 490 nm. Devices with and without IF were compared in terms of the optical power output, spectral characteristics as well as LOD values. While the IF consisted of only 7.5 pairs (15 layers) of SiO2/HfO2 layers, it resulted in an improvement of the baseline noise as well as the detection limit measured using fluorescein as test analyte, both by approximately one order of magnitude, with a LOD of 1 × 10−8 mol L−1 obtained under optimised conditions. The μ-LED-IF-OF light source was then demonstrated for use in capillary electrophoresis with fluorimetric detection. The limits of detection obtained by this device were compared to those obtained with a commercial fibre coupled LED device.  相似文献   

3.
Sensitive, rapid and inexpensive chemiluminescence (CL) imaging has been developed based on molecular imprinted polymer (MIP) sensing elements. Imprinted uniform microspheres were synthesized by precipitation polymerization. Microtiter plates (96 wells) were coated with polymer microspheres imprinted with trans-resveratrol, which were fixed in place using poly(vinyl alcohol) (PVA) as glue. The amount of polymer-bound trans-resveratrol was quantified using imidazole (IMZ)-catalyzed peroxyoxalate chemiluminescence (PO-CL) reaction. The light produced was then measured with a high-resolution CCD camera. Calibration curve corresponding to analyte concentration ranging from 0.3 to 25 μg mL−1 was obtained with a limit of detection 0.1 μg mL−1. These results showed that the MIP-based CL imaging sensor can become a useful analytical tool for quick simultaneous detection of trans-resveratrol in a large number of real samples.  相似文献   

4.
Greg E. Collins  Qin Lu  Peter Wu 《Talanta》2007,72(1):301-304
A long pathlength, three-dimensional U-type flow cell was microfabricated and evaluated for improved absorbance detection on a glass microdevice. A small diameter hole (75 μm) was laser etched in a thin glass substrate whose thickness (100 μm) defined much of the pathlength of the cell. This substrate was thermally bonded and sandwiched between two different glass substrates. The top substrate contained a typical injection cross and separation microchannel. Projecting out of the plane of the separation device was a 126 μm pathlength flow cell as defined by the laser etched hole and the attached microchannels. The flow cell was connected to a microchannel on the bottom substrate that led to a waste reservoir. The planar, flat windows on the top and bottom of this device made light introduction and collection a simple matter using a light emitting diode (LED) and microscope objective. The experimentally obtained detection limit for rhodamine B was determined to be 0.95 μM, which is nearly identical to the theoretical limit calculated by Beer's Law. A separation of three fluorescent dyes was performed, and direct comparisons were made between the transmittance changes through the narrow pathlength separation microchannel and the adjacent long pathlength, three-dimensional U-type flow cell.  相似文献   

5.
A novel, stable and highly sensitive non-enzymatic glucose (Glc) sensor was developed using vertically well-aligned multi-walled carbon nanotubes array (MWCNTs) incorporated with cupric oxide (CuO) nanoparticles. The MWCNTs array was prepared by catalytic chemical vapor deposition on a tantalum (Ta) substrate, while a simple and rapid two-step electrodeposition technique was used to prepare the CuO-MWCNTs nanocomposite. First, Cu nanoparticles were deposited onto MWCNTs at constant potential and then they were oxidized into CuO by potential cycling. The electrocatalytic activity of CuO-MWCNTs array was investigated for Glc under alkaline conditions using cyclic voltammetry and chronoamperometry. The sensor exhibited a linear response up to 3 mM of Glc and sensitivity of 2190 μA mM−1 cm−2, which is two to three orders of magnitude higher than that of most non-enzymatic Glc sensors reported in the literature. The sensor response time is less than 2 s and detection limit is 800 nM (at signal/noise = 3). When tested with human blood serum samples, the sensor exhibited high electrocatalytic activity, stability, fast response and good selectivity against common interfering species, suggesting its potential to be developed as a non-enzymatic Glc sensor.  相似文献   

6.
A novel nanocomposite was obtained through the controlled surface modification of graphene nanosheets (nanographene) with Nafion by ultrasonic oscillation. The composite was used as an ultrasensitive platform for the detection of cadmium ions (Cd2+) by differential pulse anodic stripping voltammetry (DPASV) analysis. The performance of the nanographene-based sensor was systematically compared with that of a multiwall carbon nanotube (MWCNT)-modified sensor. The results indicate that the nanographene-based sensor exhibits significant advantages over the MWCNT-based sensor in terms of repeatability, sensitivity and limit of detection (LOD). The nanographene-based sensor displayed superior analytical performance over a linear range of Cd2+ concentrations from 0.25 μg L−1 to 5 μg L−1, with a LOD of 3.5 ng L−1. This sensor was also used to systematically screen for 6 types of chemicals, including sodium salts, magnesium salts and zinc salts. It was observed that the sensor could successfully differentiate cadmium ions from interferents (magnesium salts, zinc salts, etc.). The nanographene-based sensor was also demonstrated to be a promising and reliable tool for the rapid detection of cadmium existing in tap water and for the rapid on-site analysis of critical pollution levels of cadmium.  相似文献   

7.
A new sol-gel Bi(III) sensor was developed by incorporating xylenol orange (XO) into sol-gel thin films (<1 μm thick) coated on glass slides. Several sols were produced in order to evaluate the effect of different processing parameters on the final characteristics of the sensor. Sensor films based on tetramethoxysilane (TMOS) as precursor, nitric acid catalysis, water:alkoxide ratio of 2 and XO concentration of 1.5 g l−1 were found to be the most suitable to be used as Bi(III) sensors. They presented good sensitivity, reversibility and stability, low leaching and fast response time in the proposed working conditions. These sensors were coupled to a multicommutated flow system for the determination of Bi(III) in pharmaceutical products. The absorbance of the Bi(III)-immobilized XO complex formed was monitored at 515 nm. The regeneration of the sensor was accomplished by flowing a Cl ion solution through the flow cell containing the sensor membranes. The procedure enables a relative standard deviation of results better than 0.8%, an analytical concentration range between 125.0 and 875.0 μg l−1, a detection limit of 7.0 μg l−1 and a sampling frequency of 45 samples per hour. The results obtained on real samples analysis were compared with those obtained by EDTA titrimetric method (British Pharmacopoeia), with relative deviation errors inferior to 5%.  相似文献   

8.
Novel fused-LEDs devices as optical sensors for colorimetric analysis   总被引:1,自引:0,他引:1  
The development of a novel, low power optical sensing platform based on light emitting diodes (LEDs) is described. The sensor is constructed from a pair of LEDs fused together at an angle where one LED functions as the light source and the other LED is reverse biased to function as a light detector. Sensor function is based on the level of light received by the detector diode, which varies with the reflectance of the interface between the device and its environment, or the chemochromic membrane that covers the device. A simple microprocessor circuit is used to measure the time taken for the photon-induced current to discharge the detector LED from an initial 5 V (logic 1) to 1.7 V (logic zero). This sensing device has been successfully used for colour and colour-based pH measurements and offers extremely high sensitivity, enabling detection down to the sub micro molar level of dyes.  相似文献   

9.
A new method in which a nano optical sensor for diagnosis of different diseases of seminal vesicle and sexual gland was prepared. The working principle of the method depends on the determination of the fructose concentration in semen of different patients by using nano optical sensor thin film Sm-doxycycline doped in sol–gel matrix. The assay is based on the quenching of the characteristic emission bands of Sm3+ present in silica doped Sm-doxycycline nanooptode thin film by different fructose concentrations in acetonitrile at λex = 400 nm. This method was optimized for parameters, such as, solvent effect, operational stability, shelf life and interference parameters. Good and reproducible linearity (1 × 10−9 – 5.0 × 10−5 mol L−1) with a detection limit of 9.0 × 10−10 mol L−1 and quantification limit of detection (LOQ) 2.7 × 10−9 mol L−1 were obtained. Seminal fructose determination in different patient samples after appropriate dilutions confirmed the reliability of this technique. The method was successfully applied for routine fructose monitoring in human semen samples of different cases such as; obstructive and non-obstructive azoospermia, inflammation of male accessory glands, atrophy of seminal vesicle, congenital vas deferens and retrograde ejaculation.  相似文献   

10.
In this study, gold microelectrode array (Au/MEA) with electrode of 12 μm diameter was fabricated by photolithography technique. Subsequently, polypyrrole (Ppy) modified gold microarrays sensor (Ppy/Au/MEA) was prepared by cyclic voltammetry technique. The deposition potential range and number of cycles were optimised in order to get optimum thickness of Ppy film. Scanning Electron Microscope and Atomic Force Microscope investigations reveal that Ppy coating formed at 3 cycles is porous with thickness of 1.5 μm which exhibiting high catalytic current for ascorbic acid (AA) in square wave technique (SWV). In contrast to earlier sensors designs, these Ppy/Au/MEA sensors exhibits lower detection limit (LOD) of 10 nm towards AA at physiological conditions. It also exhibits enhanced sensitivity (2.5 mA cm−2 mM−1) and long range of linear detection limit from 10 nm to 2.8 mM. In the same way, polypyrrole modified macro Au (Ppy/Au/MA) biosensor was also fabricated and its electro catalytic property towards AA was compared with that of Ppy/Au/MEA. The Ppy/Au/MA exhibits sensitivity of only 0.27 mA cm−2 mM−1, LOD of 5 μM and linear range of 10 μM to 2.2 mM. Hence, our investigations indicate that the Ppy/Au/MEA could serve as highly sensitive sensor for AA than any of the earlier designs. So, the Ppy/Au/MEA electrode was utilised for determination AA in a wide variety of real samples.  相似文献   

11.
A selective, sensitive, rapid and reliable method based on molecularly imprinted polymers (MIPs) with dual templates to determine total content of parabens in cosmetics was developed. With methylparaben (MP) and propylparaben (PP) as dual-templates, methacrylic acid (MAA) as a functional monomer and tripropylene glycol diacrylate (TPGDA) as a cross-linker, MIPs film on a glassy carbon electrode was constructed as paraben sensor. At oxidation potential of 0.94 V (vs. SCE), the peak currents on the MIPs sensor were proportional to the concentration of parabens with square wave voltammetry. As the ratio of MP to PP in the MIPs was 1:1.25, the regression equations for four parabens were almost the same. The linear range was 20-100 μM for MP and EP, 5-100 μM for PP, and 5-80 μM for BP, with detection limit of 0.4 μM for MP and EP, 0.2 μM for the others. The total content of parabens could be calculated according to the average of these four regress equations. At least 10 times of structural analogs, such as p-hydroxybenzoic acid, p-aminobenzoic acid and phenol would not interfere with the determination of parabens. Nonanalogous coexistences such as vitamin C had no response on the sensor at all. Rapid response of the MIPs sensor was obtained within 1 min. MIPs sensor had been used to determine total content of parabens in cosmetic samples with recoveries between 98.7% and 101.8%. It reveals that the MIPs sensor with multi-templates has a potential to determine the total content of a group of homologous compounds.  相似文献   

12.
Y?ld?z Uluda? 《Talanta》2010,82(1):277-383
A simple and sensitive sensor method for cancer biomarkers [prostate specific antigen (PSA) and PSA-alpha 1-antichymotrypsin (ACT) complex] analysis was developed, to be applied directly with human serum (75%) by using antibody modified quartz crystal microbalance sensor and nanoparticles amplification system. A QCM sensor chip consisting of two sensing array enabling the measurement of an active and control binding events simultaneously on the sensor surface was used in this work. The performance of the assay and the sensor was first optimised and characterised in pure buffer conditions before applying to serum samples. Extensive interference to the QCM signal was observed upon the analysis of serum. Different buffer systems were then formulated and tested for the reduction of the non-specific binding of sera proteins on the sensor surface. A PBS buffer containing 200 μg mL−1 BSA, 0.5 M NaCl, 500 μg mL−1 dextran and 0.5% Tween 20, was then selected which eliminated the interfering signal by 98% and enabled the biomarker detection assay to be performed in 75% human serum. By using Au nanoparticles to enhance the QCM sensor signal, a limit of detection of 0.29 ng mL−1 PSA and PSA-ACT complex (in 75% serum) with a linear dynamic detection range up to 150 ng mL−1 was obtained. With the achieved detection limit in serum samples, the developed QCM assay shows a promising technology for cancer biomarker analysis in patient samples.  相似文献   

13.
Volatile sulphur compounds are the primary constituents of oral malodour. Quantitative tools for the detection of oral malodour are beneficial to evaluate the intensity of malodour, analyse its causes and monitor the effectiveness of customized treatments. We have developed an objective, cost effective, do-it-yourself colorimetric sensor for oral malodour quantification. The sensor consisted of a sensing solution, a gas sampling unit for collecting a known volume of mouth air and a photometric detector. The sensing solution was iodine and the depletion of iodine on reaction with hydrogen sulphide was detected colorimetrically using starch. The detection limit of the sensor is 0.05 μg L−1 of hydrogen sulphide, which is fit-for-purpose for oral malodour detection in healthy subjects as well as halitosis patients. Volatile sulphur compounds in mouth air were quantified in healthy human volunteers using this portable sensor and the detected levels were in the range of 0.2-0.4 μg L−1. There was a good correlation between the VSC levels detected by the colorimetric sensor and halimeter (R2 = 0.934). The developed sensor can be easily fabricated in the laboratory, and it shows high potential to be used as a clinical evaluation tool for oral malodour assessments.  相似文献   

14.
A chemiluminescence one-shot sensor for hydrogen peroxide is described. It is prepared by immobilization of cobalt chloride and sodium lauryl sulphate in hydroxyethyl cellulose matrix cast on a microscope cover glass. Luminol, sodium phosphate and the sample are mixed before use and applied on the membrane by a micropipette. The calibration graph is linear in the range 20-1600 μg/L, and the detection limit of the method (3σ) is 9 μg/L. A relative standard deviation of 4.5% was obtained for 100 μg/L H2O2 (n = 11). The sensor has been applied successfully to the determination of hydrogen peroxide in rainwater.  相似文献   

15.
A new thermometric sensor, which is a transistor (OC71), has been introduced to follow thermometric titrations successfully to clear end points. The sensor was suitable in both normal and differential modes of titration. It is possible to titrate down to 1.32 μmol of HCl and 26.4 μmol of H3BO3in a final 20 ml solution with accuracy and precision of 1%, 2.2% and 1.4%, 2.2%, respectively. The sensor, in association with a pH glass electrode, was used for the determination of pK values of some well established weak acids such as, acetic acid (4.77), phosphoric acid (pK1 = 2.18, pK2 = 7.20 and pK3 = 12.32) as well as for a very weak acid of uncertain pK values H3BO3 (pK1 = 9.20, pK2 = 12.7 and pK3 = 13.80). The sensor was also examined for kinetic catalytic determination of iron(III) in water, milk and pharmaceuticals.  相似文献   

16.
Remote unattended sensor networks are increasingly sought after to monitor the drinking water distribution grid, industrial wastewater effluents, and even rivers and lakes. One of the biggest challenges for application of such sensors is the issue of in-field device calibration. With this challenge in mind, we report here the use of anodic stripping coulometry (ASC) as the basis of a calibration-free micro-fabricated electrochemical sensor (CF-MES) for heavy metal determinations. The sensor platform consisted of a photo-lithographically patterned gold working electrode on SiO2 substrate, which was housed within a custom stopped-flow thin-layer cell, with a total volume of 2–4 μL. The behavior of this platform was characterized by fluorescent particle microscopy and electrochemical studies utilizing Fe(CN)63−/4− as a model analyte. The average charge obtained for oxidation of 500 μM ferrocyanide after 60 s over a 10 month period was 176 μC, corresponding to a volume of 3.65 μL (RSD = 2.4%). The response of the platform to copper concentrations ranging from 50 to 7500 ppb was evaluated, and the ASC results showed a linear dependence of charge on copper concentrations with excellent reproducibility (RSD ≤ 2.5%) and accuracy for most concentrations (≤5–10% error). The platform was also used to determine copper and mercury mixtures, where the total metallic content was measurable with excellent reproducibility (RSD ≤ 4%) and accuracy (≤6% error).  相似文献   

17.
High quality carbonate chemistry measurements are required in order to fully understand the dynamics of the oceanic carbonate system. Seawater pH data with good spatial and temporal coverage are particularly critical to apprehend ocean acidification phenomena and their consequences. There is a growing need for autonomous in situ instruments that measure pH on remote platforms. Our aim is to develop an accurate and precise autonomous in situ pH sensor for long term deployment on remote platforms. The widely used spectrophotometric pH technique is capable of the required high-quality measurements. We report a key step towards the miniaturization of a colorimetric pH sensor with the successful implementation of a simple microfluidic design with low reagent consumption. The system is particularly adapted to shipboard deployment: high quality data was obtained over a period of more than a month during a shipboard deployment in northwest European shelf waters, and less than 30 mL of indicator was consumed. The system featured a short term precision of 0.001 pH (n = 20) and an accuracy within the range of a certified Tris buffer (0.004 pH). The quality of the pH system measurements have been checked using various approaches: measurements of certified Tris buffer, measurement of certified seawater for DIC and TA, comparison of measured pH against calculated pH from pCO2, DIC and TA during the cruise in northwest European shelf waters. All showed that our measurements were of high quality. The measurements were made close to in situ temperature (+0.2 ?C) in a sampling chamber which had a continuous flow of the ship’s underway seawater supply. The optical set up was robust and relatively small due to the use of an USB mini-spectrometer, a custom made polymeric flow cell and an LED light source. The use of a three wavelength LED with detection that integrated power across the whole of each LED output spectrum indicated that low wavelength resolution detectors can be used instead of the current USB mini spectrophotometer. Artefacts due to the polychromatic light source and inhomogeneity in the absorption cell are shown to have a negligible impact on the data quality. The next step in the miniaturization of the sensor will be the incorporation of a photodiode as detector to replace the spectrophotometer.  相似文献   

18.
Oh Seok Kwon  O. Young Kweon 《Talanta》2010,82(4):1338-1526
Poly(3,4-ethylenedioxythiophene) nanotubes (PEDOT NTs) flexible membrane was successfully fabricated by vapor deposition polymerization (VDP) mediated electrospinning for ammonia gas detection. PVA nanofibers (NFs) were electrospun as a core part and polyvinyl alcohol (PVA)/PEDOT coaxial nanocables (NCs) were prepared by VDP method via EDOT monomer adsorption onto the electrospun PVA NFs as templates. To obtain the PEDOT NTs membrane, the PVA NFs were removed from PVA/PEDOT coaxial NCs with distilled water. PVA/PEDOT coaxial NCs and PEDOT NTs had the conductivities of 71 and 61 S cm−1 and were applied as a transducer for ammonia gas detection in the range of 1-100 parts per million (ppm) of NH3 gas. They exhibited the minimum detectable level of ca. 5 parts per million (ppm) and fast response time (less than 1 s) towards ammonia gas. In a recovery time, the PEDOT NTs membrane sensor was ca. 30 s and shorter compared to that of the membrane sensor based on the PVA/PEDOT NCs (ca. 50 s). In addition, sensor performance of PEDOT NTs membrane was also undertaken as a function of membrane thickness. Thick membrane sensor (30 μm) had the enhanced sensitivity and the sensitivity on the membrane thickness was in the order of 30 μm > 20 μm > 10 μm at 60 ppm of NH3 gas.  相似文献   

19.
Nickel hydroxide nanoparticles were successfully electrodeposited on graphite electrode (Gr/NiONP) and employed as a robust non-enzymatic glucose sensor. The results of cyclic voltammetry (CV) and chronoamperometry demonstrated that the Gr/NiONP electrode displayed high electrocatalytic activity toward glucose. The oxidation current is directly related to the glucose concentration from 1 μM to 15 mM. Besides, the glucose sensor displayed high sensitivity (2400 μA mM−1 cm−2) with a detection limit of 0.53 μM (S/N = 3) in basic solution. Moreover, the sensor showed excellent selectivity, reproducibility and stability properties. The relative standard deviation is 1.2% for 10 successive measurements in 16 μM glucose. Interestingly, the signal for glucose was maintained at 95% of its initial value even after 6 months of storage under ambient conditions. Gr/NiONP electrode has also been tested to detect glucose in human serum with satisfactory results.  相似文献   

20.
Simultaneous two-dimensional liquid chromatography (2D-LC) is an implementation of two-dimensional liquid chromatography which has the potential to provide very fast, yet highly efficient separations. It is based on the use of time × space and space × space separation systems. The basic principle of this instrument has been validated long ago by the success of two-dimensional thin layer chromatography. The construction of a pressurized wide and flat column (100 mm × 100 mm × 1 mm) operated under an inlet pressure of up to 50 bar was described previously. However, to become a modern analytical method, simultaneous 2D-LC requires the development of detectors suitable for the monitoring of the composition of the eluent of this pressurized planar, wide column. An array of five equidistant micro-electrochemical sensors was built for this purpose and tested. Each sensor is a three-electrode system, with the working electrode being a 25 μm polished platinum micro-electrode. The auxiliary electrode is a thin platinum wire and the reference electrode an Ag/AgCl (3 M sat. KCl) electrode. In this first implementation, proof of principle is demonstrated, but the final instrument will require a much larger array.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号