首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An HPTLC method has been developed that coelutes both the isomers of cefpodoxime proxetil (CFP). CFP was chromatographed on a silica gel 60 F254 TLC plate using toluene:acetonitrile (6:4) as a mobile phase and was quantified at 234 nm. The method was validated with respect to linearity, accuracy, precision and specificity. The limit of detection and limit of quantification for CFP were found to be 0.150 and 0.4 μg spot?1, respectively. The proposed method was successfully used to determine the amount of CFP present in the marketed tablets and self-nanoemulsifying systems.  相似文献   

2.
Dogan-Topal  B.  Ozkan  S. A.  Uslu  B. 《Chromatographia》2007,66(1):25-30

A rapid, sensitive, and specific reverse phase high performance liquid chromatography with diode array detection procedure for the simultaneous determination of abacavir, efavirenz and valganciclovir in spiked human serum is described. Separation was performed on a 5 μm Waters Spherisorb column (250 × 4.6 mm ID) with acetonitrile: methanol:KH2PO4 (at pH 5.00) (40:20:40 v/v/v) isocratic elution at a flow rate of 1.0 mL min−1. Calibration curves were constructed in the range of 50–30,000 ng mL−1 for abacavir and efavirenz, and 10–30,000 ngmL−1 for valganciclovir in serum samples. The limit of detection and limit of quantification concentrations of the HPLC method were 3.80 and 12.68 ng mL−1 for abacavir, 2.61 and 8.69 ng mL−1 for efavirenz, 1.30 and 4.32 ng mL−1 for valganciclovir. The method has been applied, without any interference from excipients or endogenous substances, for the simultaneous determination of these three compounds in human serum.

  相似文献   

3.
Dogan-Topal  B.  Uslu  B.  Ozkan  S. A. 《Chromatographia》2007,66(1):97-101

This paper describes the validation of an isocratic high-performance liquid chromatographic method for the assay of valganciclovir in raw materials, tablets and human serum samples. Valganciclovir and fluvastatin (internal standard) were well separated using a reversed phase column and a mobile phase consisting of a mixture of acetonitrile:methanol:KH2PO4 (0.02 M) (40:20:40; v/v/v) (at pH 5.0). The mobile phase was pumped at 1.0 mL min−1 flow rate and valganciclovir was detected by diode-array detection at 255 nm. The retention times for valganciclovir and fluvastatin were 3.41 and 5.60 min, respectively. A linear response (r > 0.999) was observed in the range of 10–30,000 ng mL−1 in mobile phase and serum. The limit of detection and limit of quantification were found as 2.95 and 9.82 ng mL−1 in mobile phase and 1.73 and 5.77 ng mL−1 in human serum samples, respectively. Validation parameters as precision, accuracy, selectivity, reproducibility and system suitability tests were also determined. The method can be used for valganciclovir assay of tablets and human serum samples as the method separates valganciclovir from tablet excipients and endogenous substances.

  相似文献   

4.

An accurate, simple, reproducible, and sensitive liquid chromatographic method was developed and validated for the captopril determination in controlled release tablets. The analyses were performed at room temperature on a reversed-phase Phenomenex Luna C18 column (250 mm × 4.6 mm). The mobile phase was composed of water:methanol (45:55; v/v) pH 2.5, and it was eluted isocratically at a 1.0 mL min−1 flow rate. The method was validated in terms of specificity, linearity, quantification limit, detection limit, accuracy, precision and robustness. The response was linear in the range 0.3–1.5 mg mL−1 (r 2 = 0.9983). The relative standard deviation values for inter-and intra-day precision were 0.77% and 0.50%, respectively. Recoveries ranged between 97.7 and 99.1%. The method was successfully applied for the determination of captopril in the developed formulations.

  相似文献   

5.
Molybdenum disulfide (MoS2) or tungsten disulfide (WS2), as a promising catalyst, is widely investigated for hydrogen evolution reaction (HER). In this work, a composite electrocatalysts MoxW1-xS2 is successfully decorated on carbon fiber paper (CFP) through a facile hydrothermal method. The three-dimensional porous CFP can enable the diffusion and penetration of electrolyte. Comparing with MoS2 and WS2 catalyst, the composite electrocatalyst MoxW1-xS2 nanosheets can expose the large number of electrochemically active sites. Hence, the as-prepared MoxW1-xS2/CFP (3:1) exhibit the outstanding HER catalytic activity with the small Tafel slope of 68 mV dec?1 and the low overpotential of ??178.4?±?0.5 mV at a current density of 10 mA cm?2. Chronoamperometric current test for 18 h confirm the long-term stability of the composite electrocatalyst.  相似文献   

6.
&#;&#;leyen  E. A. &#;.  &#;zden  T.  &#;zilhan  S.  Toptan  S. 《Chromatographia》2007,66(1):109-113

A simple, rapid, sensitive and selective LC-MS method was developed and validated for quantification of fexofenadine in human plasma. The LC-MS system was operated under the positive electrospray ionisation mode (ESI). After liquid–liquid extraction, fexofenadine analysis was performed on a C18 column with a mobile phase of acetonitrile: 10 mM ammonium acetate: formic acid, 70:30:0.1 (v/v/v) at a flow rate of 1 mL min−1 by using loratadine as internal standard. The lower limit of quantitation was 3 ng mL−1 for fexofenadine. The assay precision ranged between 1.05 and 12.56% and accuracy ranged between 82.00 and 109.07%. The validated method was successfully used to analyze human plasma samples in bioequivalence studies.

  相似文献   

7.
Ate&#;  Z.  &#;zden  T.  &#;zilhan  S.  Toptan  S. 《Chromatographia》2007,66(1):123-127

A simple method for the determination of carbamazepine and its active metabolite carbamazepine-10,11-epoxide by ultra performance liquid chromatography (UPLC) with ultraviolet absorbance detection (TUV) was developed. The method involves a two-step protein precipitation by liquid–liquid extraction. Phenytoin sodium was used as the internal standard. The separation was carried out on Acquity C18 column with acetonitrile:methanol:KH2PO4 buffer (adjusting pH to 4.6 with 85% o-phosphoric acid) (180/180/170, v/v/v) as the mobile phase at a flow rate of 0.4 mL min−1. Linear detection response was obtained for concentrations ranging from 50 to 5,000 ng mL−1. The limit of quantification (LOQ) was 50 ng mL−1. The method was validated successfully for the determination of carbamazepine and its active metabolite carbamazepine-10,11-epoxide, which can be applied through pharmacokinetics and bioequivalence studies.

  相似文献   

8.

A sensitive, specific and rapid high-performance liquid chromatography method was developed in an effort to quantify extremely low curcuminoid levels for the future transdermal experiments where the curcuminoids are incorporated with excipients such as microemulsion, liposomes, and micelles. The chromatographic separation was performed using a Symmetry® C18, 250 × 4.6 mm, 5-μm column, with a mobile phase composed of 5 mM acetonitrile:phosphoric acid (45:55, v/v) at a flow rate of 1.0 mL min−1, it was sensitive with a low limit of quantitation for curcuminoids (0.626 ng mL−1 for curcumin) and good linearity (r 2 ≥ 0.999) over the range 1–100 ng mL−1. All the validation data, such as accuracy and precision, were within the required limits from the ICH guideline. The assay method was successfully applied during forced degradation of curcuminoid solutions. The method retained its accuracy and precision when the standard addition technique was applied.

  相似文献   

9.
Yang  Qin-Feng  Wu  Yin-Liang 《Chromatographia》2012,75(17):1075-1080

A fast analytical method for the simultaneous determination of fumonisin B1 (FB1) and fumonisin B2 (FB2) in corn using a novel QuEChERS method and LC–MS–MS was developed and validated. Samples were extracted with methanol–water (3:1 v/v) by means of ultrasonic extraction. The extract was purified with a novel modified QuEChERS method. Firstly, FB1 and FB2 in the extract were retained with primary secondary amine (PSA). Then, FB1 and FB2 were released from PSA with 1.0 % formic acid in methanol. The final eluate was diluted with water, and analyzed by LC–MS–MS on a Waters Acquity BEH C18 column with 0.1 % formic acid in water/methanol as mobile phase with gradient elution. Mean recoveries of 83.5–102.4 % with CVs of 3.6–10.5 % were obtained at fortification levels of 2, 50 and 1,000 μg kg−1. The limit of quantification was 2.0 μg kg−1.

  相似文献   

10.
《Analytical letters》2012,45(14):2608-2620
Abstract

A capillary zone electrophoresis (CZE) method has been developed for the determination of the antibiotic sparfloxacin in tablets. The CZE separation was performed using 75 µm×35 cm fused-silica capillary under the following conditions: 25°C; applied voltage, 12 kV; 25 mM H3PO4-NaOH running buffer (pH 8.5). The detection wavelength was 254 nm. Flumequine was used as internal standard (IS). The method was suitably validated with respect to linearity, limit of detection and quantification, accuracy, precision, specificity, and robustness. The calibration was linear from 10 to 60 µg mL?1 and the limit of detection and quantification were 5.38 and 9.46 µg mL?1, respectively. Recoveries ranging from 95.68%–102.4% were obtained in the determination of sparfloxacin that were spiked to placebos. Excipients in the commercial tablets and degraded products from different stress conditions did not interfere in the assay. The method was successfully applied to the determination of sparfloxacin in pharmaceutical tablets.  相似文献   

11.
Radhakrishnanand  P.  Subba Rao  D. V.  Himabindu  V. 《Chromatographia》2008,68(11):1059-1062

A new and accurate chiral liquid chromatographic method has been developed for the determination of enantiomeric purity of darifenacin [(S)-enantiomer] in bulk drugs and extended release tablets. Normal phase chromatographic separation was performed on an immobilized cellulose based chiral stationary phase (Chiralpak-IC) with n-hexane:ethanol:diethylamine (50:50:0.3, v/v/v) as mobile phase at a flow rate of 1.0 mL min−1. The elution time was ~15 min. The resolution (R s ) between the enantiomers was greater than four and interestingly the (R)-enantiomer was eluted prior to darifenacin in the developed method. The limit of detection (LOD) and limit of quantification (LOQ) for the (R)-enantiomer were 0.02 μg and 0.07 μg, respectively, for a 10 μL injection volume. The method was extensively validated in terms of linearity, precision and accuracy and satisfactory results were obtained. Robustness studies were also conducted. The sample solution stability of darifenacin was determined and the compound was found to be stable for a study period of 48 h.

  相似文献   

12.
《Analytical letters》2012,45(10):2179-2189
Abstract

In the presence of Pb(Ac)2, the silicon dioxide nanoparticle containing rhodamine 6G (R‐SiO2) can emit strong and stable solid substrate‐room temperature phosphorescence (SS‐RTP) signal on the surface of acetyl cellulose membrane (ACM) at λexem=482/649 nm. It was found in the research that specific affinity adsorption reaction between triticum vulgare lectin (WGA) (which was labeled with luminescent silicon dioxide nanoparticle) and alkaline phosphatase (AP) can be carried out on the surface of ACM. The product of the reaction can emit stronger SS‐RTP signal. A new method of SS‐RTP for the determination of AP was established, based on an affinity adsorption reaction between AP and WGA labeled with nanoparticles containing rhodanime 6G luminescent molecules. The linear range of this WGA‐AP‐WGA‐R‐SiO2 method is 1.00–360.00 ag AP spot?1 (sample volume: 0.40 µL spot?1, corresponding concentration range: 2.50–900.00 fg mL?1). The regression equation of working curve is ΔIp=16.24+0.8856 mAP (ag spot?1), r=0.9993. Detection limit of this method calculated by 3Sb/k is 0.14 ag spot?1. After 11‐fold replicate measurements, RSD are 3.9% and 3.1% for the systems containing 1.00 and 360.00 ag AP spot?1, respectively. Compared with R‐SiO2‐WGA‐AP method (detection limit: 0.45 ag spot?1, corresponding concentration range: 2.00–320.00 ag spot?1), the sensitivity of WGA‐AP‐WGA‐R‐SiO2 method was obviously improved and the linear range was wider. The sensitivity, accuracy, and precision of this method are high. It has been successfully applied to determine AP in human serum.  相似文献   

13.
Zhang  Tianhong  Meng  Ping  Kou  Wen  Ma  Rongli  Zhang  Cong  Sun  Yongbin 《Chromatographia》2010,71(11):1101-1105

A specific and sensitive UPLC-MS–MS was developed for the determination of trimetazidine in human plasma. The sample preparation was based on a single-step liquid–liquid extraction with acetic ether. The chromatographic separation was on a C18 analytical column (50 mm × 2.1 mm, 1.7 μm) with acetonitrile and 10 mM ammonium acetate (30:70, v/v) as the mobile phase, and a triple-quadrupole mass spectrometer equipped with an electrospray ionization source (ESI) applied for detection. The method was linear over the concentration ranges of 0.25–100.00 ng mL−1 for trimetazidine, and the lower limit of quantification (LLOQ) was 0.25 ng mL−1. The intra- and inter-day relative standard deviation (RSD) were less than 15% and the relative error (RE) were all within 15%. Finally, this method has been successfully applied to analyze plasma samples from a bioequivalence study with 18 volunteers.

  相似文献   

14.

A rapid, sensitive and specific method to quantify pregabalin in human plasma using metaxalone as the internal standard is described. Sample preparation involved simple protein precipitation by using acetronitrile as solvent. The extract was analyzed by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry (LC-MS–MS). Chromatography was performed isocratically on Thermo Hypurity C18 5 μm analytical column, (50 mm × 4.6 mm i.d.). The assay of pegabalin was linear calibration curve over the range 10.000–10000.000 ng mL−1. The lower limit of quantification was 10.000 ng mL−1 in plasma. The method was successfully applied to the bioequivalence study of pregabalin capsules (150.0 mg) administered as a single oral dose.

  相似文献   

15.

A new, sensitive and stability indicating liquid chromatographic method has been developed for the determination of imatinib mesylate (IM). Efficient chromatographic separation was achieved using a C18 column with simple mobile phase combination delivered in an isocratic mode and quantitation was carried out using ultraviolet detection. For the first time, a novel microwave assisted degradation procedure was employed for stress testing studies. In addition, orthogonal separation technique was applied to demonstrate selectivity of the proposed method. The method has demonstrated excellent linearity over the range of 25–1,600 ng mL−1. Moreover, the method was found to be sensitive with a low limit of detection (3.35 ng mL−1) and limit of quantitation (10.16 ng mL−1). The method has shown good and consistent recoveries (99.35–100.69%) with low intra- and inter-day relative standard deviation (RSD) (<2.5%). Experimental design confirmed that peak area was unaffected by small changes in critical factors, in robustness study. The validated method was successfully applied for determination of IM in pharmaceutical formulations.

  相似文献   

16.
Fan  Zhong  Chen  Zhiyan  Tian  Zhaofu  Zhou  Yun  Xu  Aifei  Meng  Dongling  Huang  Shijie  Liu  Huimin  Li  Xiaolan 《Chromatographia》2014,77(21):1563-1568

Vinyl chloride (VC) in the vapor phase of mainstream cigarette smoke was determined under both International Organization for Standardization (ISO) and Health Canada intensive (HCI) machine smoking regimens, which was suspected to be carcinogenic compound. VC was collected by passing the mainstream cigarette smoke through a Cambridge Filter Pad (CFP) into cryogenic traps containing methanol. The impinger solutions were fortified with VC-d 3 and analyzed by GC–MS. Limits of detection for vinyl chloride was 0.9 ng mL−1 with the recovery in the range of 93.2–98.4 %. Moreover, the intra-day and inter-day precision was 7.39 and 9.77 %, respectively. Under HCI machine smoking regimen, the vinyl chloride yields in vapor phase of mainstream cigarette smoke were much higher and the average increase was greater than 100 % compared with those under ISO smoking condition.

  相似文献   

17.
Radhakrishnanand  P.  Subba Rao  D. V.  Himabindu  V. 《Chromatographia》2009,69(3-4):369-373

A new and accurate chiral liquid chromatographic method has been developed for the separation of palonosetron hydrochloride (PALO) and its (R,R)-enantiomer in bulk drug samples with an elution time of about 20 min. The chromatographic separation was carried out by normal phase chromatography using an immobilized cellulose based chiral stationary phase (Chiralpak-IC) with a mobile phase composed of n-hexane:ethanol:1,4 dioxane:trifluoroacetic acid:diethylamine (65:30:5:0.3:0.3, v/v) pumped at a flow rate of 1.0 mL min−1. The resolution (R s ) between the enantiomers was found to be greater than 3.0 and interestingly the (R,R)-enantiomer was eluted prior to the (S,S)-enantiomer (PALO) in the developed method. Mobile phase additives, trifluoroacetic acid and diethylamine played a key role in achieving chromatographic resolution between the enantiomers and also in enhancing chromatographic efficiency. The limit of detection (LOD) and limit of quantification (LOQ) of the (R,R)-enantiomer were found to be 0.03 and 0.1 μg respectively for 10 μL injection volume. The developed method shows excellent linearity (r 2 > 0.999) over a range of LOQ to 0.3% for the (R,R)-enantiomer. The percentage recovery of the (R,R)-enantiomer in bulk drug samples ranged from 97.2 to 102.3 revealing good sensitivity of the developed method. Robustness studies were also carried out on the developed method.

  相似文献   

18.
Konieczna  Lucyna  Plenis  Alina  Ol&#;dzka  Ilona  Kowalski  Piotr  B&#;czek  Tomasz 《Chromatographia》2010,71(11):1081-1086

A rapid and sensitive reversed-phase high-performance liquid chromatographic method for analysis of fexofenadine in human plasma has been developed and optimized. The analytes were extracted from biological samples by solid-phase extraction on hydrophilic–lipophilic balance cartridges. LC separation was performed on a C18 analytical column (125 mm × 4 mm i.d., 5-μm particles) with 42:58 (v/v) acetonitrile–water adjusted to pH 2.7 with 85% orthophosphoric acid as mobile phase. Fluorescence detection was performed with excitation at 230 nm and emission at 290 nm. The total time for chromatographic separation was 7 min. The method was validated in accordance with EU guidelines by analysis of plasma samples fortified with fexofenadine at concentrations between 0.05 and 800 ng mL−1. Calibration plots were linear in this range. Mean recovery was typically 94.03% and the detection limit was 0.05 ng mL−1. The time required for quantitative analysis is shorter than that required by other methods.

  相似文献   

19.
Asfak  Vora  Mrinalini  Damle  Leena  Bhat  Rahul  Godge 《Chromatographia》2007,66(11):941-943

A simple, selective, rapid, precise and accurate reverse phase high pressure liquid chromatographic method has been developed for the simultaneous estimation of diclofenac sodium and rabeprazole sodium from pharmaceutical formulations. The method was developed using a HiQ SiL C18 (250 mm × 4.6 mm i.d.) column with a mobile phase consisting of methanol:water, (80:20 v/v), at a flow rate of 1.25 mL min−1. Detection was carried out at 284 nm. Indapamide was used as an internal standard. The developed method was validated for linearity, accuracy, precision, limit of detection and limit of quantitation. The proposed method can be used for the estimation of these drugs in combined dosage forms.

  相似文献   

20.

A reversed phase LC method was developed and validated to analyze the in vitro release of AZT from microemulsions. A mobile phase of acetonitrile:water (15:85) was used. The method validation showed good selectivity and linearity (r = 0.9993) for sample concentrations ranging from 0.6 to 100.0 μg mL−1. The RSD values (0.7–4.3%) and percentage recovery (88.1–109.8%) were within acceptable limits. The limit of detection (LOD) and limit of quantitation (LOQ) were found to be 0.012 and 0.041 μg mL−1. Quantitative analysis of the values obtained in the drug release assay indicates that the microemulsions used promote sustained release of AZT, which follows a Fickian diffusion mechanism.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号