首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
彭钢  刘白玲  王斌  李晨英 《化学进展》2012,24(8):1572-1582
起源于放射性免疫分析的临近闪烁分析法(scintillation proximity assay,SPA)是一种均相、灵敏、快速和简便的基于闪烁载体的分析平台。该平台可用于筛选药物靶点的先导化合物和研究其生理过程。由于无需分离,易于固定药物靶点和检测其活性,SPA成为一种重要的高通量筛选方法。由于放射性标记分子和亲和标签分子的多样化和商业化、以及液闪计数器和液相操作等技术的发展,SPA已经广泛用于受体结合、高通量药物筛选、酶分析、放射性免疫分析、蛋白质-蛋白质相互作用和细胞水平分析等方面。本文阐述了SPA原理,讨论了其关键技术(包括闪烁载体、液闪计数器和放射性标记分子),分析了其评价体系;同时简述了SPA分析的发展, 并介绍了其在高通量筛选中的应用实例, 归纳了存在的问题,给出了未来的发展趋势。目前,基于SPA和荧光分析方法已成为高通量药物筛选的热点研究领域, 这些筛选技术的革新必然提升我们对细胞体系生物学的全面理解和促进先导化合物筛选过程的显著进步。  相似文献   

2.
In the search for new therapeutic chemicals, lab-on-a-chip systems have recently emerged as innovative and efficient tools for cell-based assays and high throughput screening. Here, we describe a novel, versatile and simple device for cell-based assays at the bench-top. We created spatial variations of porosity on the surface of a membrane filter by microcontact printing with a biocompatible polymer (PDMS). We called such systems Micro-Printed Membranes (μPM). Active compounds dispensed on the porous areas, where the membrane pores are not clogged by the polymer, can cross the membrane and reach cells growing on the opposite side. Only cells immediately below those porous areas could be stimulated by chemicals. We performed proof-of-principle experiments using Hoechst nuclear staining, calcein-AM cell viability assay and destabilization of the cytoskeleton organisation by cytochalasin B. Resulting fluorescent staining properly matched the drops positioning and no cross-contaminations were observed between adjacent tests. This well-less cell-based screening system is highly flexible by design and it enables multiple compounds to be tested on the same cell tissue. Only low sample volumes in the microlitre range are required. Moreover, chemicals can be delivered sequentially and removed at any time while cells can be monitored in real time. This allows the design of complex, sequential and combinatorial drug assays. μPMs appear as ideal systems for cell-based assays. We anticipate that this lab-on-chip device will be adapted for both manual and automated high content screening experiments.  相似文献   

3.
Cell-based assays have always played an important role in the pharmaceutical industry, providing information about the functional effects of compounds. These functional assays have traditionally accompanied facile biochemical high throughput screening programmes, being applied as secondary assays in the later stages of lead development. However, with the disappointing reality that there is not likely to be a plethora of novel, druggable targets in the post-genomic era, the role of cell-based assays in drug discovery is beginning to change. Competition to develop the "best" agents for well established targets and find more effective ways of identifying "novel" agents is driving the industry towards a "quality" versus "quantity" approach. Advances in genetic engineering, automation compatible functional assay technologies and the introduction of more sophisticated robotic systems, have facilitated the application of cell-based assays to primary screening. However, despite some apparent success to move these assays into the routine "toolbox" for high throughput screening, certain preconceptions and concerns about cell-based assays persist and the subject remains a topic of much debate. Here we use examples from the screening portfolio at Pfizer, Sandwich, to discuss the practical and theoretical considerations of employing cell-based assays in HTS with a focus on G-protein coupled receptors.  相似文献   

4.
5.
Ion channels are attractive targets for drug discovery with recent estimates indicating that voltage and ligand-gated channels account for the third and fourth largest gene families represented in company portfolios after the G protein coupled and nuclear hormone receptor families. A historical limitation on ion channel targeted drug discovery in the form of the extremely low throughput nature of the gold standard assay for assessing functional activity, patch clamp electrophysiology in mammalian cells, has been overcome by the implementation of multi-well plate format cell-based screening strategies for ion channels. These have taken advantage of various approaches to monitor ion flux or membrane potential using radioactive, non-radioactive, spectroscopic and fluorescence measurements and have significantly impacted both high-throughput screening and lead optimization efforts. In addition, major advances have been made in the development of automated electrophysiological platforms to increase capacity for cell-based screening using formats aimed at recapitulating the gold standard assay. This review addresses the options available for cell-based screening of ion channels with examples of their utility and presents case studies on the successful implementation of high-throughput screening campaigns for a ligand-gated ion channel using a fluorescent calcium indicator, and a voltage-gated ion channel using a fluorescent membrane potential sensitive dye.  相似文献   

6.
《中国化学快报》2021,32(11):3446-3449
Single-cell imaging, a powerful analytical method to study single-cell behavior, such as gene expression and protein profiling, provides an essential basis for modern medical diagnosis. The coding and localization function of microfluidic chips has been developed and applied in living single-cell imaging in recent years. Simultaneously, chip-based living single-cell imaging is also limited by complicated trapping steps, low cell utilization, and difficult high-resolution imaging. To solve these problems, an ultra-thin temperature-controllable microwell array chip (UTCMA chip) was designed to develop a living single-cell workstation in this study for continuous on-chip culture and real-time high-resolution imaging of living single cells. The chip-based on ultra-thin ITO glass is highly matched with an inverted microscope (or confocal microscope) with a high magnification objective (100 × oil lens), and the temperature of the chip can be controlled by combining it with a home-made temperature control device. High-throughput single-cell patterning is realized in one step when the microwell array on the chip uses hydrophilic glass as the substrate and hydrophobic SU-8 photoresist as the wall. The cell utilization rate, single-cell capture rate, and microwell occupancy rate are all close to 100% in the microwell array. This method will be useful in rare single-cell research, extending its application in the biological and medical-related fields, such as early diagnosis of disease, personalized therapy, and research-based on single-cell analysis.  相似文献   

7.
Label-free cell-based functional assays   总被引:1,自引:0,他引:1  
Label-free technologies based on electrical impedance or refractive index are new tools for measuring a cell-based functional response. Although the technologies are relatively new to high throughput screening cell-based applications, they are rapidly generating interest in that they are able to measure a phenotypic response using cells natively expressing the target protein without using dyes or cellular extracts. In addition, one can measure the cellular response using a kinetic mode resulting in an assay potentially rich in content. This article will describe these technologies and their applications in measuring cell proliferation, cell attachment and spreading, cell apoptosis and their application for several receptor target classes, including receptor tyrosine kinases and G protein-coupled receptors. The potential utility and drawbacks of these tools for high throughput screening, directed screening and compound profiling will also be discussed.  相似文献   

8.
Selection of personalized chemotherapy regimen for individual patients has significant potential to improve chemotherapy efficacy and to reduce the deleterious effects of ineffective chemotherapy drugs. In this study, a rapid and high-throughput in vitro drug response assay was developed using a combination of microwell array and molecular imaging. The microwell array provided high-throughput analysis of drug response, which was quantified based on the reduction in intracellular uptake (2-[N-(7-nitrobenz-2-oxa-1,3-diazol-4-yl)amino]-2-deoxy-d-glucose) (2-NBDG). Using this synergistic approach, the drug response measurement was completed within 4 h, and only a couple thousand cells were needed for quantification. The broader application of this microwell molecular imaging approach was demonstrated by evaluating the drug response of two cancer cell lines, cervical (HeLa) and bladder (5637) cancer cells, to two distinct classes of chemotherapy drugs (cisplatin and paclitaxel). This approach did not require an extended cell culturing period, and the quantification of cellular drug response was 4–16 times faster compared with other cell-microarray drug response studies. Moreover, this molecular imaging approach had comparable sensitivity to traditional cell viability assays, i.e., the MTT assay and propidium iodide labeling of cellular nuclei;and similar throughput results as flow cytometry using only 1,000–2,000 cells. Given the simplicity and robustness of this microwell molecular imaging approach, it is anticipated that the assay can be adapted to quantify drug responses in a wide range of cancer cells and drugs and translated to clinical settings for a rapid in vitro drug response using clinically isolated samples.   相似文献   

9.
10.
梁怡萧  潘建章  方群 《色谱》2021,39(6):567-577
药物筛选是新药研发的关键步骤,创新药物的发现需要采用适当的药物作用靶点对大量化合物样品进行筛选。高通量筛选系统能够实现数千个反应同时测试和分析,大大提高了药物筛选的实验规模和效率。其中基于细胞水平的高通量药物筛选系统因为更加接近人体生理条件,成为主要的筛选模式。而目前发展成熟的高通量细胞筛选系统主要基于多孔板,存在细胞培养条件单一、耗时费力、试剂消耗量大等问题,且较难实现复杂的组合药物筛选。微流控技术作为一种在微米尺度通道中操纵和控制微流体的技术,具有微量、高效、高通量和自动化的优点,能较好地克服多孔板筛选系统的不足,为构建细胞高通量药物筛选系统提供了一种高效、可靠的技术手段。微流控系统在细胞培养材料、芯片结构设计和流体控制方面均可灵活变化,能更好地实现对细胞生长微环境的调控和模拟。文章综述了基于微流控技术的细胞水平高通量药物筛选系统的研究进展,按照不同的微流体操控模式,对基于灌注流、液滴和微阵列的3种类型的微流控细胞筛选系统进行了分类介绍,并分别总结了它们的优缺点,最后展望了微流控细胞水平高通量药物筛选系统的发展前景,提出了该领域目前存在的问题以及解决问题的方向。  相似文献   

11.
We describe the design, using shape comparison and fast docking computer algorithms, and rapid parallel synthesis of a 1300 member array based on GSK7721, a 4-aminobenzonitrile androgen receptor (AR) antagonist identified by focused screening of the GSK compound collection. The array yielded 352 submicromolar and 17 subnanomolar AR agonists as measured by a cell-based reporter gene functional assay. The rapid synthesis of a large number of active compounds provided valuable information in the optimization of AR modulators, which may be useful in treating androgen deficiency in aging males.  相似文献   

12.
13.
Kim J  Taylor D  Agrawal N  Wang H  Kim H  Han A  Rege K  Jayaraman A 《Lab on a chip》2012,12(10):1813-1822
We describe the development of a fully automatic and programmable microfluidic cell culture array that integrates on-chip generation of drug concentrations and pair-wise combinations with parallel culture of cells for drug candidate screening applications. The device has 64 individually addressable cell culture chambers in which cells can be cultured and exposed either sequentially or simultaneously to 64 pair-wise concentration combinations of two drugs. For sequential exposure, a simple microfluidic diffusive mixer is used to generate different concentrations of drugs from two inputs. For generation of 64 pair-wise combinations from two drug inputs, a novel time dependent variable concentration scheme is used in conjunction with the simple diffusive mixer to generate the desired combinations without the need for complex multi-layer structures or continuous medium perfusion. The generation of drug combinations and exposure to specific cell culture chambers are controlled using a LabVIEW interface capable of automatically running a multi-day drug screening experiment. Our cell array does not require continuous perfusion for keeping cells exposed to concentration gradients, minimizing the amount of drug used per experiment, and cells cultured in the chamber are not exposed to significant shear stress continuously. The utility of this platform is demonstrated for inducing loss of viability of PC3 prostate cancer cells using combinations of either doxorubicin or mitoxantrone with TRAIL (TNF-alpha Related Apoptosis Inducing Ligand) either in a sequential or simultaneous format. Our results demonstrate that the device can capture the synergy between different sensitizer drugs and TRAIL and demonstrate the potential of the microfluidic cell array for screening and optimizing combinatorial drug treatments for cancer therapy.  相似文献   

14.
Advances in high throughput screening technologies have led to the identification of many small molecules, "hits", with activities toward the target of interest. And, as the screening technologies become faster and more robust, the rate at which the molecules are identified continues to increase. This evolution of high throughput screening technologies has generated a significant strain on the laboratories involved with the downstream profiling of these hits using cell-based assays. The CellCard System, by enabling multiple targets and/or cell lines to be assayed simultaneously within a single well, provides a platform on which selectivity screening can be quickly and robustly performed. Here we describe two case studies using the beta-lactamase and beta-galactosidase reporter gene systems to characterize G protein-coupled receptor agonist activity. Using these examples we demonstrate how the implementation of this technology enables assay miniaturization without micro-fluidic devices as well as how the inclusion of intra-well controls can provide a means of data quality assessment within each well.  相似文献   

15.
The feasibility of DNA microarray sensor technology as a routine technique of molecular pharmacology to perform high throughput drug screening and the advantages of directly labeled RNA for a high throughput experiment are presented in this paper. A novel, single-step direct chemical labeling method for DNA microarray target samples has been developed to reduce the sample amount, cost, time and error of the experiment by eliminating the need for enzyme mediated labeling. Reproducibility of the data for high throughput drug screening is demonstrated by monitoring differential gene expression of a set of 45 gene targets involved in the genotoxic stress response pathways.  相似文献   

16.
Xu Y  Yao H  Wang L  Xing W  Cheng J 《Lab on a chip》2011,11(14):2417-2423
In basic cell biology research and drug discovery, it is important to rapidly introduce genes, proteins or drug compounds into cells without permanent damage. Here, we report a three dimensional SU-8 micro-well structure sandwiched with an indium tin oxide (ITO) electrode-covered slide from the top and an individually addressable array of microelectrodes on the bottom to allow parallel delivery of exogenous molecules into various cells in a spatially specific manner. A positive dielectrophoretic force was selectively applied by energizing appropriate electrodes to capture the dispersed cells at the bottom electrode, while the micro-wells were designed to confine cells in situ when the positive dielectrophoretic force is removed. The combination of spatial positive dielectrophoresis (pDEP) and micro-wells made it possible to construct cell microarrays with specific patterns. Once the cells become attached to the electrodes, different plasmids can be introduced sequentially for selective electroporation. The present cell arraying-assisted electroporation chip integrates a pDEP-assisted cell positioning function with selective electroporation to provide a simple and efficient method for gene transfer. This platform is ideal for high throughput screening of compounds in parallel and thus holds promise for applications in cellular and molecular research.  相似文献   

17.
In the determination of contaminants (dioxins, polychlorinated biphenyls, polyaromatic hydrocarbons), cell-based assays are useful methods for screening purposes: they are mainly characterized by high sample throughput and lower costs than the Mass Spectrometry (MS)-based methods. Although cell-based assays can be sensitive enough for the determination of dioxins and related substances in agreement with the presently tolerable limits in food and feed (Regulation No. 2375/2001/EC and Directive 2003/57/EC respectively), their lack of specificity make their use rather questionable in control laboratories. In this paper, we present and compare results obtained from the analysis of a limited number of feed samples by both gas chromatography-high resolution mass spectrometry (GC-HRMS) and cell-based assay (DR-CALUX: dioxin responsive-chemically activated luciferase gene expression) methods. The DR-CALUX screening led to less than 10% false non-compliant and no false compliant results. In addition, there is a good correlation between GC-HRMS and DR-CALUX data. However, these preliminary results have to be confirmed on a larger number of samples to demonstrate that total toxic equivalent (TEQ), including dioxins, furans and dioxin-like polychlorobiphenyls (PCBs) can be monitored in feed and food with a cell-based assay. Presented at AOAC Europe/Eurachem Symposium March 2005, Brussels, Belgium  相似文献   

18.
There is a continuing need for increased throughput in the evaluation of new drug entities in terms of their pharmacokinetic (PK) parameters. This report describes an alternative procedure for increasing the throughput of plasma samples assayed in one overnight analysis: the use of parallel high performance liquid chromatography (HPLC) combined with tandem mass spectrometry (parallel LC/MS/MS). For this work, two HPLC systems were linked so that their combined effluent flowed into one tandem MS system. The parallel HPLC/APCI-MS/MS system consisted of two Waters 2690 Alliance systems (each one included an HPLC pump and an autosampler) and one Finnigan TSQ 7000 triple quadrupole mass spectrometer. Therefore, the simultaneous chromatographic separation of the plasma samples was carried out in parallel on two HPLC systems. The MS data system was able to deconvolute the data to calculate the results for the samples. Using this system, 20 compounds were tested in one overnight assay using the rapid rat PK screening model which includes a total of 10 standards plus samples and two solvent blanks per compound tested. This application provides an additional means of increasing throughput in the drug discovery PK assay arena; using this approach a two-fold increase in throughput can be achieved in the assay part of the drug discovery rat PK screening step.  相似文献   

19.
Digital microfluidics for cell-based assays   总被引:1,自引:0,他引:1  
We introduce a new method for implementing cell-based assays. The method is based on digital microfluidics (DMF) which is used to actuate nanolitre droplets of reagents and cells on a planar array of electrodes. We demonstrate that this method is advantageous for cell-based assays because of automated manipulation of multiple reagents in addition to reduced reagent use and analysis time. No adverse effects of actuation by DMF were observed in assays for cell viability, proliferation, and biochemistry. A cytotoxicity assay using Jurkat T-cells was performed using the new method, which had approximately 20 times higher sensitivity than a conventional well plate assay. These results suggest that DMF has great potential as a simple yet versatile analytical tool for implementing cell-based assays on the microscale.  相似文献   

20.
The conversion of the genomic information produced by the recent sequencing projects into a comprehensive understanding of the human proteome has yet to occur. A new technology that represents a potential bridge between genomics and proteomics is reverse transfection. Reverse transfection cell microarrays are produced by overlaying cDNA arrays with mammalian cells, generating localized clusters of transfected cells with each cluster overexpressing a unique protein. This miniaturized cell-based microarray format affords parallel functional analysis of thousands of cDNA constructs in a high throughput format. In this report we document the development of a co-transfection methodology for reverse transfection applications. The demonstrated high co-transfection efficiency with a "marker" plasmid encoding for GFP enables the identification of transfected cells and eliminates the need for epitope-tagged constructs in cell-based high throughput screening applications using reverse transfection. This co-transfection method was used to study in parallel the structure/function of multiple versions of the v-Src protein using automated fluorescence microscopy. The wild-type v-Src protein and four mutants having insertions or deletions in the SH2 or SH3 domains displayed high levels of tyrosine kinase activity in HEK293T cells. Three other mutated v-Src proteins, including a kinase-dead version, were shown to be defective for tyrosine kinase activity. This reverse co-transfection approach is applicable for high throughput screening of both cDNA libraries and positional scanning recombinant protein libraries.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号