首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A method has been developed for the determination of nitrate with the Technicon Autoanalyser in the range 2–10 p.p.m. The method depends on the reduction of nitrate to nitrite by hydrazine in alkaline solution, with copper as a catalyst. The nitrite produced diazotises sulphanilamide and the product is coupled with N-(1-naphthyl) ethylenediamine, to give a red dye, the absorbance of which is measured at 550 mμ. A relative standard deviation of 3–4% is obtained.  相似文献   

2.
We describe capillary zone electrophoresis (CZE) for the simultaneous determination of bromide, nitrite and nitrate ions in seawater. Artificial seawater was adopted as the carrier solution to eliminate the interference of high concentrations of salts in seawater. The artificial seawater was free from bromide ion to enable the determination of bromide ion in a sample solution. For the purpose of reversing the electroosmotic flow (EOF), 3 mM cetyltrimethylammonium chloride (CTAC) was added to the carrier solution. A 100 microm ID (inside diameter) capillary was used to extend the optical path length. The limits of detection (LODs) for bromide, nitrite, and nitrate ions were 0.46, 0.072, and 0.042 mg/L (as nitrogen), respectively. The LODs were obtained at a signal to noise ratio (S/N) of 3. The values of the relative standard deviation (RSD) of peak area for these ions were 1.1, 1.5, and 0.97%. The RSDs of migration time for these ions were 0.61, 0.69, and 0.66%. Artificial seawater samples containing various concentrations of bromide, nitrite, and nitrate ions were analyzed by the method. The error was less than +/-12% even if the concentration ratio of bromide ion to nitrite or nitrate ion was 20-240. The proposed method was applied to the determination of bromide, nitrite, and nitrate ions in seawater samples taken from the surface and the seabed. These ions in other environmental waters such as river water and rainwater samples were also determined by ion chromatography (IC) as well as this method.  相似文献   

3.
Tsang EP  Burns DT  Flockhart BD 《Talanta》1992,39(11):1561-1567
Various azines and substituted phenylene diamines are oxidized by the nitrite ion to give stable radicals in an autocatalytic reaction. This finding has now been developed into highly sensitive methods for nitrite determination by EPR spectrometry. Thus, when the reagent is phenothiazine, the detection limit for nitrite is 0.012 ppm, the relative standard deviation at 0.05 ppm is 1.9%, and the analytical range is 0-1.5 ppm. With N,N,N',N'-tetramethyl-p-phenylenediamine as the reagent, the corresponding values are 0.025 ppm, 2.6%, and 0-1.3 ppm. Nitrate can be determined after prior reduction to nitrite. A mixture of nitrite and nitrate ions can also be quantitatively analysed. The EPR methods were applied to the determination of the nitrite and nitrate contents of prepacked cooked ham and of soft-spreading cheese. The results agreed well with those obtained by ISO and AOAC standard methods for these samples. ca*|Author for correspondence.  相似文献   

4.
土壤硝态氮反映土壤短期氮素供应水平,实时了解土壤硝态氮的含量为精准农业和农业面源污染防控提供支撑,因此,在线实时检测土壤硝态氮方法突破就显得十分迫切。土壤硝态氮中的硝酸根离子在土壤中的高水溶性和流动性为全固态硝酸根离子选择电极高敏感检测土壤中硝态氮提供了条件,固态硝态氮离子选择电极的离子选择膜反应硝酸根离子在被测溶液中的浓度。采用全固态硝酸根离子选择电极,且与温度电极和pH电极融合组成电极阵列对土壤饱和溶液中的硝态根离子进行检测。设计了高输入阻抗运算放大电路对电极信号进行采集,并通过微处理控制蠕动泵完成土壤硝态氮待测溶液连续流动测量及实时传输结果。实验结果表明,电极响应时间≤15 s,斜率-51.63 mV/decade,线性范围10-5-10-2.2 mol/L,最低检测限10-5.23 mol/L。相对标准差在0.78%-4.47%范围内,加标回收率均在90%-110%以内。与国家标准紫外可见分光光度法测试结果相比,相关系数(R2)为0.9952,为土壤硝态氮在现场检测奠定技术基础。  相似文献   

5.
A new design of the liquid-state electrode for nitrate ions is proposed. It contains a porous wick soaked with the liquid ion-exchanger, and has no internal reference solution. This electrode was used for nitrate determination of tap water at the level 8–10 p.p.m. The effects of chloride and hydrogencarbonate are eliminated by the addition of silver sulphate and a phosphate buffer, which also maintains constant ionic strength. Precision of a series of measurements is better than 2%, but the results show differences up to 10% compared to the colorimetric brucine procedure.  相似文献   

6.
This short paper highlights the suitability of ion chromatography with post-column indirect fluorescence detection to determine simultaneously nitrite and nitrate based on the quenching of tryptophan native fluorescence. The method uses an enhanced fluorescence mobile phase containing tryptophan and detects the suppression of fluorescence of the mobile phase due to the elution of the target ions. The phenomenon of fluorescence quenching of tryptophan is highly induced by the presence of phosphate ions. The quenched fluorescence intensity exhibits concentration dependence in the range 1-25 mg/l and 3-65 mg/l for nitrite and nitrate, respectively. The relative standard deviation for five replicates of a standard solution containing a mixture of 5 mg/l of nitrite and 10 mg/l of nitrate lies around 2.8%. This simple coupling technique results in a relatively sensitive, fast, and accurate method, allowing for both qualitative and quantitative analysis of nitrite and nitrate. The method can easily be implemented to real samples such as foodstuffs, fertilizers and soils and is proven to be precise and accurate when compared with reference methods.  相似文献   

7.
Zatar NA  Abu-Eid MA  Eid AF 《Talanta》1999,50(4):819-826
A method for spectrophotometric determination of nitrite and nitrate is described. This method is based on the reduction of phosphomolybdic acid to phosphomolybdenum blue complex by sodium sulfide. The obtained phosphomolybdenum blue complex is oxidized by the addition of nitrite and this causes a reduction in intensity of the blue color. The absolute decrease in the absorbance of the blue color or the rate of its decrease is found to be directly proportional to the amount of nitrite added. The absorbance of the phosphomolybdenum blue complex is monitored spectrophotometrically at 814 nm and related to the concentration of nitrite present. The effect of different factors such as acidity, stability of the complex, time, temperature, phosphate concentration, molybdenum concentration, sodium sulfide concentration and the tolerance amount of other ions have been reported. Maximum absorbance is at 814 nm. The range of linearity using the conventional method is 0.5-2.0 ppm with molar absorptivity of 1.1 x 10(4) l mol(-1) cm(-1). and a relative standard deviation of 2.6% for five measurements. The range of linearity using the reaction rate method is 0.2-3.6 ppm with a relative standard deviation of 2.4% for five measurements. The method is applied for determination of nitrite and nitrate in water, meat products and vegetables.  相似文献   

8.
We describe a combination of selected ions as a terminating ion which is useful for transient isotachophoresis (ITP) in capillary zone electrophoresis (CZE) for the determination of nitrite and nitrate in seawater. In addition to 150 mM sulfate as the principal terminating ion, 10 mM bromate was added to a sample solution as the additional terminating ion. Artificial seawater containing 3 mM cetyltrimethylammonium chloride (CTAC) was adopted as a background electrolyte (BGE). The limits of detection (LODs) for nitrite and nitrate were 2.2 and 1.0 microg/L (as nitrogen), respectively. The LODs were obtained at a signal to noise ratio (S/N) of 3. The values of the relative standard deviation (RSD) of peak area for these ions were 1.9 and 1.4%. The RSDs of peak height were 1.7 and 1.9%, the RSDs of migration time 0.11%. The proposed method was applied to the determination of nitrite and nitrate in a proposed certified reference material for nutrients in seawater, MOOS-1, distributed by the National Research Council of Canada (NRC). The results almost agreed with the assigned tolerance interval.  相似文献   

9.
Ion-exchange chromatography using a high-capacity anion exchanger with UV detection was applied to the determination of nitrate in seawater. Major ions in seawater samples did not affect the peak shape and the retention time of the nitrate when an alkaline metal cation-chloride solution was used as an eluent at high concentrations (0.5-2 mol/l). At a wavelength of 220 nm, the peak of bromide was very small because of low absorption, while its separation from the nitrate peak was good at high concentrations. Among the eluents tested, lithium chloride gave the best separation of nitrate from bromide. It was estimated that the lithium ion had the least potential for ion-pair formation with nitrate, and its retention time was prolonged compared with the retention times when using other cations; with bromide and nitrite, such an effect was not observed. The results of shipboard seawater nitrate determination by our method in the South Pacific Ocean and Antarctic Sea showed good agreement with those by the conventional photometric method using continuous flow.  相似文献   

10.
Nowadays, nitrite and nitrate ions are analyzed in biological samples using laborious and expensive methods; such as HPLC, CE, MS-MS. In this work, the simultaneous analysis of nitrite and nitrate ions was conducted by electrospray ionization-ion mobility spectrometry (ESI-IMS), without using any complicated or laborious derivitization step. Ion mobility spectrometry with low cost, inexpensive maintenance and very fast analysis makes an attractive technique for the simultaneous determination of these ions in foodstuff and drinking water samples. The analyte interference was systematically investigated for binary mixture analysis. The obtained results provided detection limits of 3.8 and 4.7 μg/L for nitrite and nitrate, respectively. A linear dynamic range of about 2 orders of magnitude, and relative standard deviations below 5% were obtained by the proposed method for the analysis of both ions. Also, the proposed method was used to analyze various real samples of potato and drinking water samples, and the obtained results confirmed the capability of negative ESI-IMS for the simultaneous detection of nitrite and nitrate.  相似文献   

11.
Nitrite in aqueous solution is reduced to nitric oxide with hydroquinone in pH 2 phosphate buffer. The nitric oxide is swept with nitrogen to an anodically polarized membrane-covered platinum electrode, where it is oxidized to nitrate. The resulting current is linearly related to nitrite concentration in the original solution from the detection limit of 18 nmol to 5 μmol of nitrite. Nitrate is subsequently determined similarly after reduction to nitric oxide with hydroquinone in 50% sulfuric acid containing ammonium molybdate catalyst. The linear range is from the detection limit of 40 nmol to 10 μmol of nitrate.  相似文献   

12.
Two flow-injection manifolds have been investigated for the determination of nitrate. These manifolds are based on the reduction of nitrate to nitrite and determination of nitrite by gas-phase molecular absorption spectrophotometry. Nitrate sample solution (300 microL) which is injected to the flow line, is reduced to nitrite by reaction with hydrazine or passage through the on-line copperized cadmium (Cd-Cu) reduction column. The nitrite produced reacts with a stream of hydrochloric acid and the evolved gases are purged into the stream of O2 carrier gas. The gaseous phase is separated from the liquid phase using a gas-liquid separator and then swept into a flow-through cell which has been positioned in the cell compartment of an UV-visible spectrophotometer. The absorbance of the gaseous phase is measured at 204.7 nm. A linear relationship was obtained between the intensity of absorption signals and concentration of nitrate when Cd-Cu reduction method was used, but a logarithmic relationship was obtained when the hydrazine reduction method was used. By use of the Cd-Cu reduction method, up to 330 microg of nitrate was determined. The limit of detection was 2.97 microg nitrate and the relative standard deviations for the determination of 12.0, 30.0 and 150 microg nitrate were 3.32, 3.87 and 3.6%, respectively. Maximum sampling rate was approximately 30 samples per hour. The Cd-Cu reduction method was applied to the determination of nitrate and the simultaneous determination of nitrate and nitrite in meat products, vegetables, urine, and a water sample.  相似文献   

13.
Shiddiky MJ  Won MS  Shim YB 《Electrophoresis》2006,27(22):4545-4554
A CE microsystem coupled with a microchip and a copper-(3-mercaptopropyl) trimethoxysilane (Cu-MPS) complex-modified carbon paste electrode (CPE) was developed for the simultaneous analysis of nitrite and nitrate. The method is based on the electrocatalytic reduction of both analytes with the modified electrode. The Cu-MPS complex was characterized by voltammetric, XPS, and FT-IR analyses. Experimental parameters affecting the sensitivity of the modified electrode were assessed and optimized. The best separation was achieved in a 60 mm separation channel filled with a 20 mM acetate buffer of pH 5.0 containing 3.0 mM CTAB at separation field strength of -250 V/cm within 90 s. The detection potential for the simultaneous analysis of nitrite and nitrate was found to be -225 mV versus Ag/AgCl. A reproducible response (RSD of 3.2% (nitrite) and 2.8% (nitrate), n = 8) for repetitive sample injections reflected the negligible electrode fouling at the modified CPE. The interference effect was examined for other inorganic ions and biological compounds. A wide hydrodynamic range between 0.25 and 120 microM was observed for analyzing nitrite and nitrate with the sensitivities of 0.069 +/- 0.003 and 0.065 +/- 0.002 nA/microM, and the detection limits, based on S/N = 3, were found to be 0.09 +/- 0.007 and 0.08 +/- 0.009 microM, respectively. The applicability of the method to water and urine samples analyses was demonstrated.  相似文献   

14.
A simple method for the determination of nitrite and nitrate in human plasma has been developed using CZE with minimal sample preparation. Field‐amplified sample stacking (FASS) was used to achieve submicromolar detection by dilution of the plasma sample with deionized water. In CZE, the separation of nitrite and nitrate was achieved within 10 min without adding EOF modifier. The optimal condition was achieved with 50 mM phosphate buffer at pH 9.3. The ninefold diluted plasma samples were injected hydrodynamically for 40 s into a 60 cm×75 μm id uncoated fused‐silica capillary. The separation voltage was 20 kV (negative potential) and UV detection was performed at 214 nm. The linearity curves for nitrite and nitrate were obtained by the standard addition method. The estimated LODs for nitrite and nitrate in ninefold diluted plasma sample were 0.05 and 0.07 μM, respectively. The LODs for nitrite and nitrate in original plasma samples were 0.45 and 0.63 μM. The intra‐ and inter‐day precisions for both analytes were <2.6% and the recovery ranged between 92.3 and 113.3%. It was found that nitrite was more stable than nitrate in the plasma after the sample preparation. This proposed method was applied to a number of human plasma samples and the measured nitrite and nitrate concentrations in human plasma were consistent with the literature ranges.  相似文献   

15.
It is now well established that the oxidation of iodide ions and the reduction of nitrate ions take place when -irradiated sodium chloride is dissolved in aqueous iodide and nitrate solutions, respectively. The yield of iodine decreases and that of nitrite increases with increasing concentration of nitrate in a binary mixture of iodide and nitrate when the irradiated salt is dissolved in it. The results are explained on the basis of the reactions of colour centres with iodide and nitrate ions present in the binary mixture.  相似文献   

16.
A new catalytic spectrophotometric method is reported for the simultaneous determination of nitrite and nitrate by flow injection analysis, based on the catalytic effect of nitrite on the redox reaction between pyrogallolsulfonephthalein and potassium bromate in acidic media. Nitrate can also be on-line reduced to nitrite with a modified copper-coated cadmium reduction column. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of pyrogallolsulfonephthalein at 465 nm. Various analytical parameters such as effects of acidity, reagent concentrations, flow rates, sample sizes, lengths of the reaction coil and temperatures were studied and were optimized. Under the optimized conditions, the calibration graph was linear for 2.4 to 160 ng ml(-1) of nitrite and 4.0 to 100 ng ml(-1) of nitrate. The influences of potential interfering cations and anions for nitrite and nitrate determination were studied. The method is successfully applied for food and water samples. Up to ten samples can be analyzed per hour.  相似文献   

17.
In this work a new electrochemical sensor based on an Ag-doped zeolite-expanded graphite-epoxy composite electrode (AgZEGE) was evaluated as a novel alternative for the simultaneous quantitative determination of nitrate and nitrite in aqueous solutions. Cyclic voltammetry was used to characterize the electrochemical behavior of the electrode in the presence of individual or mixtures of nitrate and nitrite anions in 0.1 M Na2SO4 supporting electrolyte. Linear dependences of current versus nitrate and nitrite concentrations were obtained for the concentration ranges of 1-10 mM for nitrate and 0.1-1 mM for nitrite using cyclic voltammetry (CV), chronoamperometry (CA), and multiple-pulsed amperometry (MPA) procedures. The comparative assessment of the electrochemical behavior of the individual anions and mixtures of anions on this modified electrode allowed determining the working conditions for the simultaneous detection of the nitrite and nitrate anions. Applying MPA allowed enhancement of the sensitivity for direct and indirect nitrate detection and also for nitrite detection. The proposed sensor was applied in tap water samples spiked with known nitrate and nitrite concentrations and the results were in agreement with those obtained by a comparative spectrophotometric method. This work demonstrates that using multiple-pulse amperometry with the Ag-doped zeolite-expanded graphite-epoxy composite electrode provides a real opportunity for the simultaneous detection of nitrite and nitrate in aqueous solutions.  相似文献   

18.
A sensitive flow-injection method for the chemiluminescent determination of ultra-low concentration of nitrate in water is presented. Nitrate is on-line photolytically converted to peroxynitrite by absorption of UV light inside of 60 mm long quartz capillary (i.d. 530 µm, o.d. 720 µm). Peroxynitrite is subsequently determined by the chemiluminescent reaction with luminol. The detection limit of nitrate is 7 × 10?10 M (S/N = 3). The linear range of the method is 2 × 10?9–1 × 10?5 M nitrate. The interference of nitrite is eliminated by its conversion to nitrogen after mixing of sample with a solution of sulfamidic acid. Other common anions do not interfere. The interference of cations is eliminated by passing the sample through a cation-exchange column. The FIA procedure allows analysing of 15 samples per hour. The method was applied to the determination of nitrate in various real water samples. The results are in good agreement with a reference ion chromatographic method.  相似文献   

19.
An ion chromatographic method with post-column derivatization and spectrophotometric detection is presented for the determination of nitrate and nitrite (NOx) in baby food. NOx residues found naturally or added as preservatives were extracted from baby foods and determined by using ion chromatography with post-column derivatization and spectrophotometric detection. Nitrate was reduced to nitrite online by post-column reduction using vanadium(lll) chloride and heat. Nitrite reacted with Griess reagent to produce a dye that was detected at 525 nm. The use of V(III) and heat to promote the reduction of nitrate to nitrite online is a novel feature of this detection system. The determination of incurred NOx residues in samples by using AOAC Method 993.03 yielded results comparable to those obtained by ion chromatography with spectrophotometric detection. The toxic and carcinogenic metal cadmium used in the AOAC Method to reduce the nitrate to nitrite was avoided. The proposed method provides simultaneous determination of nitrate and nitrite. Average recoveries of nitrate and nitrite residues ranged from 82 to 107% for fortification levels of 25-400 ppm.  相似文献   

20.
A new approach for in situ electrodeposition of a renewable copper layer onto a copper electrode is reported. The active surface was obtained by anodic dissolution of a copper electrode at an appropriate potential and further redeposition of copper ions still remaining at the diffusion layer. Under optimal experimental conditions the peak current response increases linearly with nitrate concentration over a range of 0.1-2.5 mmol L−1. The repeatability of measurements for nitrate was evaluated as 1.8% (N = 15) and the limit of detection of the method was found to be 11 μmol L−1 (S/N = 3). Nitrate contents in two different samples (mineral water and sausages) compared well with those obtained from using the standard Griess protocol at a 95% of confidence level measured by the t-student test. The interference from chloride on the nitrate analysis and the possibility of simultaneous determination of nitrite were also examined.  相似文献   