首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
With the implementation of recombinant DNA technology in the pharmaceutical industry, some synthetic insulins have been developed in order to improve the therapy of diabetes. These analogues differ only slightly in the amino acid sequence, therefore displaying a great challenge for analytical chemistry. Within the work presented in this paper, capillary zone electrophoresis (CZE), micellar electrokinetic chromatography (MEKC) with sodium dodecylsulphate (SDS) as micelle-forming agent, and microemulsion electrokinetic chromatography (MEEKC) with microemulsions consisting of SDS, n-octane and 1-butanol were investigated for the separation of human insulin and five synthetic analogues. Best results were achieved with a solvent-modified MEKC system consisting of 100 mM sodium dodecyl sulphate and 15% acetonitrile in 10 mM borate buffer (pH 9.2). A similar system based on perfluorooctanoic acid as micelle-forming agent in ammonium acetate (pH 9.2) was successfully employed for the hyphenation with a quadrupole/time-of-flight mass spectrometer via a sheath-flow interface. In this case, detection limits at 10 mg/L could be achieved.  相似文献   

2.
A new hexane-in-water microemulsion was investigated as buffer in microemulsion EKC (MEEKC). At difference with other microemulsions, the addition of cosurfactant was not necessary to stabilize the microemulsion. The proposed microemulsion was successfully used to achieve electrophoretic separation of seven antibiotics including nitroimidazoles, cephapirin and tetracyclines. Selectivity and separation efficiency achieved in MEEKC were compared with MEKC. MEEKC technique proved to be more efficient than MEKC for performing the separation of the analytes and the presence of microemulsions was found to be critical to achieve the separation of tetracyclines. The proposed microemulsion also points out that solvents with high volatility, such as hexane, can be stabilized and used as a microemulsion of SDS.  相似文献   

3.
In this study, microemulsions of the chiral surfactant polysodium N-undecenoyl-D-valinate (poly-D-SUV) was utilized for enantiomeric separation by investigating two approaches using polymeric chiral surfactant in microemulsion electrokinetic chromatography (MEEKC). In the first approach, poly-D-SUV was used as an emulsifier surfactant along with 1-butanol and n-heptane. Enantioseparation of anionic or partially anionic binaphthyl derivatives, anionic barbiturates, and cationic paveroline derivatives were achieved by varying the mass fraction of 1-butanol, n-heptane and poly-D-SUV. For anionic or partially anionic analytes, relatively lower mass fractions of n-heptane, and poly-D-SUV were found to give optimum chiral separations as compared to that for cationic solutes. In the second approach, the chiral microemulsion polymer was prepared by polymerizing mixtures of 3.50% (w/w) of sodium N-undecenoyl-D-valinate (D-SUV) and 0.82% (w/w) of n-heptane (core phase) at varying concentration of 1-butanol. After polymerization, the n-heptane and 1-butanol were removed to yield solvent free microemulsion polymers (MPs) which were then utilized for the separation of anionic binaphthyl derivatives and anionic barbiturates. When MPs of D-SUV were utilized for chiral separation, 1.00% (w/w) 1-butanol and 3.50% (w/w) 1-butanol was optimum for enantioseparation of (+/-)-BNP and (+/-)-BOH, respectively. On the other hand, for anionic (+/-)-barbiturates very low concentration of butanol (0.25%, w/w) provided optimum resolution. Compared with micellar electrokinetic chromatography (MEKC), the use of micelle polymers or microemulsion polymers in MEEKC showed dramatic enhancement for resolution of (+/-)-BNP, while this enhancement was less dramatic for other binaphthyls [(+/-)-BOH, (+/-)-BNA] as well as for (+/-)-barbiturates and (+/-)-paveroline derivatives. However, higher separation efficiency of the enantiomers was always observed with MEEKC than in MEKC.  相似文献   

4.
In this study, separation and determination of nine preservatives ranging from hydrophilic to hydrophobic properties, which are commonly used as additives in various pharmaceutical and cosmetic products, by micellar electrokinetic chromatograpy (MEKC) and microemulsion electrokinetic chromatography (MEEKC) were compared. The effect of temperature, buffer pH, and concentration of surfactant on separation were examined. In MEKC, the separation resolution of preservatives improved markedly by changing the sodium dodecyl sulfate concentration. Temperature and pH of running buffers were used mainly to shorten the magnitude of separation time. However, in order to detect all preservatives in a single run in a MEEKC system, a microemulsion of higher pH was needed. The separation resolution was improved dramatically by changing temperature, and a higher concentration of SDS was necessary for maintaining a stable microemulsion solution, therefore the separation of the nine preservatives in MEEKC took longer than in MEKC. An optimum MEKC method for separation of the nine preservatives was obtained within 9.0 min with a running buffer of pH 9.0 containing 20 mM SDS at 25 degrees C. A separation with baseline resolution was also obtained within 16 min using a microemulsion of pH 9.5 which composed of SDS, 1-butanol, and octane, and a shorter capillary column at 34 degrees C. Finally, the developed MEKC and MEEKC methods determined successfully preservatives in various cosmetic and pharmaceutical products.  相似文献   

5.
Recent applications of microemulsion electrokinetic chromatography   总被引:1,自引:0,他引:1  
Huie CW 《Electrophoresis》2006,27(1):60-75
Compared to MEKC, the presence of a water-immiscible oil phase in the microemulsion droplets of microemulsion EKC (MEEKC) gives rise to some special properties, such as enhanced solubilization capacity and enlarged migration window, which could allow for the improved separation of various hydrophobic and hydrophilic compounds, with reduced sample pretreatment steps, unique selectivities and/or higher efficiencies. Typically, stable and optically clear oil-in-water microemulsions containing a surfactant (SDS), oil (octane or heptane), and cosurfactant (1-butanol) in phosphate buffer are employed as separation media in conventional MEEKC. However, in recent years, the applicability of reverse MEEKC (water-in-oil microemulsions) has also been demonstrated, such as for the enhanced separation of highly hydrophobic substances. Also, during the past few years, the development and application of MEEKC for the separation of chiral molecules has been expanded, based on the use of enantioselective microemulsions that contained a chiral surfactant or chiral alcohol. On the other hand, the application of MEEKC for the characterization of the lipophilicity of chemical substances remains an active and important area of research, such as the use of multiplex MEEKC for the high-throughput determination of partition coefficients (log P values) of pharmaceutical compounds. In this review, recent applications of MEEKC (covering the period from 2003 to 2005) are reported. Emphases are placed on the discussion of MEEKC in the separation of chiral molecules and highly hydrophobic substances, as well as in the determination of partition coefficients, followed by a survey of recent applications of MEEKC in the analysis of pharmaceuticals, cosmetics and health-care products, biological and environmental compounds, plant materials, and foods.  相似文献   

6.
A comparison between chiral cyclodextrin‐modified microemulsion electrokinetic chromatography (CD‐MEEKC) and cyclodextrin‐modified micellar electrokinetic chromatography (CD‐MEKC) for the enantiomeric separation of esbiothrin was carried out. For both methods, the separation conditions were optimized by varying CD types and concentration, running buffer pH and compositions, organic modifiers, and temperature. The optimal CD‐MEEKC conditions were 0.8% n‐heptane, 2.3% SDS, 6.6% n‐butanol, 90.3% 10 mM sodium tetraborate containing 3% (w/v, the ratio of CD mass to microemulsion volume) methyl‐β‐cyclodextrin, pH 10, 25°C. The optimized CD‐MEKC conditions were 3.3% SDS, 96.7% 10 mM sodium tetraborate containing 5% (w/v) β‐CD, pH 10, 25°C. The difference in physicochemical properties of the buffer and CDs resulted in different optimal CD type. The competitive distribution between the microemulsion (or micelle) and chiral CD contributed to the chiral separation. Both methods provided excellent separation (Rs ~? 3) with similar migration time (ca. 15 min). CD‐MEEKC provided higher separation efficiencies (>300000) than CD‐MEKC (>200000). The LODs for CD‐MEEKC and CD‐MEKC were 4.7 μg/mL and 3.2 μg/mL, respectively. The RSDs of migration time and peak area for CD‐MEEKC were slightly higher than for CD‐MEKC. Both the demonstrated CD‐MEEKC and CD‐MEKC methods provided high efficiencies, low LODs, and reproducible enantioseparations of esbiothrin.  相似文献   

7.
Tao Wen  Guoan Luo  Jian Wang  Bo Yao  Jun Zhu 《Talanta》2007,71(2):854-860
Microemulsion electrokinetic chromatography (MEEKC) and solvent modified micellar electrokinetic chromatography (MEKC) were investigated with the goal of the rapid separation of complex heroin and amphetamine samples. The rapid simultaneous separation of 17 species of heroin, amphetamine and their basic impurities and adulterants was performed within about 10 min using MEEKC for the first time, whereas solvent modified MEKCs were unable to resolve all the components. The comparisons between MEEKC and solvent modified MEKC proved internal lipophilic organic phase in microemulsions played an important role in improving the separation performance with respect to efficiency. However, the role of internal lipophilic organic phase in MEEKC was disgusted at high concentrations of cosurfactant, and the separations of MEEKC and 1-butanol modified MEKC became similar at high concentrations of 1-butanol. The evaluation of reproducibility, linearity and detection limit of optimized MEEKC method provided good results for all the analytes investigated, thus allowing its application to real controlled drug preparation analysis.  相似文献   

8.
建立了以离子液体为添加剂的反向微乳毛细管电泳(IL-MEEKC)法分离测定化妆品中氢化可的松、泼尼松和醋酸氢化可的松3种糖皮质激素的方法.微乳毛细管电泳的最佳缓冲体系组成为:2.4% SDS+6.6%正丁醇+0.5%正辛烷+35 mmol/L BMIM-BF4+20 mmol/L磷酸二氢钠缓冲液(pH 2.2);运行电...  相似文献   

9.
Yang X  Xia Y  Tao C  Liao Y  Zuo Y  Liu H 《Electrophoresis》2007,28(11):1744-1751
An investigation of the basic factors which govern the microemulsion EKC (MEEKC) and MEKC for the separation of four benzoylurea (BU) insecticides and their four analogs was carried out. In MEEKC, the separation of eight BU compounds was optimized by changing the microemulsion composition, such as concentration of SDS, octane, n-butanol, and isopropanol percentages, as well as capillary temperature. Separation optimization was also carried out for MEKC, showing that ACN and a high level of another additive gamma-CD were needed to achieve effective separation of these analytes. Although separation with baseline resolution was achieved by either MEEKC or MEKC methods, the separation selectivity resulting from the proposed MEEKC method was completely different from that of MEKC. In addition, analytical time in MEEKC was longer than that in MEKC, but in view of theoretical plate numbers, detection limits, and reproducibility, both methods were effective for the analysis of BU insecticides and their analogs.  相似文献   

10.
The influences of the composition of microemulsion on the microstructure including dimensions and ζ potentials of microdroplets were measured in details. The average dynamic dimension of microdroplets was measured by dynamic laser light scattering, and ζ potential was determined to characterize average surface charge density of microdroplets. The experiment results showed that increase of the amount of surfactant resulted in decrease of microdroplet size but almost invariant ζ potential, which would enlarge migration time of the microdroplet in MEEKC. With increment of cosurfactant concentration, the microdroplet size had an increasing trend, whereas the ζ potential decreased. Thus, observed migration velocity of microdroplets increased, which made the separation window in MEEKC shortened. Neither dimension nor ζ potential of microdroplets changed by varying both the type and the amount of the oil phase. Adding organic solvent as modifier to microemulsion did not change the microdroplet size, but lowered ζ potential. The migration time of microdroplet still became larger, since EOF slowed down owing to organic solvent in capillary. So, besides increment of surfactant concentration, organic additive could also enlarge the separation window. Increase of cosurfactant concentration was beneficial for separation efficiency thanks to the looser structure of swollen microdroplet, and the peak sharpening might compensate for the resolution and peak capacity owing to a narrow separation window. Except the oil phase, tuning the composition of microemulsion would change the microstructure, eventually could be exploited to optimize the resolution and save analysis time in MEEKC.  相似文献   

11.
Wu CH  Chen TH  Huang KP  Wang GR  Liu CY 《Electrophoresis》2007,28(20):3691-3696
A novel microemulsion based on a mixture of diethyl L-tartrate (DET) and SDS was developed for the microemulsion EKC (MEEKC) determination of structurally related steroids. The system consisted of 0.5% w/w DET, 1.7% w/w SDS, 1.2% w/w 1-butanol, 89.6% w/w phosphate buffer (40 mM, pH 7.0), and 7% w/w ACN. With an applied voltage of +10 kV, a baseline separation of aldosterone (A), cortisone acetate (CA), dexamethasone (D), hydrocortisone (H), hydrocortisone acetate (HA), prednisolone (P), prednisolone acetate (PA), prednisone (Ps), triamcinolone (T), and triamcinolone acetonide (TA) could be achieved. Under the optimized conditions, the reproducibility of the retention time (n = 4) for most of the compounds was less than +/-0.8% with the exception of A, Ps, and T. The average number of theoretical plates was 18 800 plates/m. The results were compared with those achieved by the modified micellar EKC (MEKC). MEEKC showed obvious advantages over MEKC for the separation of highly hydrophobic substances. To further evaluate the system, we tested the MEEKC method by analyzing corticosteroids in a spiked urine sample.  相似文献   

12.
The migration behaviour of isoquinoline, quinoline, and methyl derivatives of quinoline in different capillary electrophoretic modes has been systematically investigated. Optimised separation conditions were established by varying the key parameters (solvent, pH, temperature, surfactant concentration, core phase) for aqueous and non‐aqueous capillary zone electrophoresis (NACE), micellar electrokinetic chromatography (MEKC) with anionic or non‐ionic micelles (SDS, Brij 35), and microemulsion electrokinetic chromatography (MEEKC) with charged or uncharged microemulsion droplets. A separation of all quinolines could be achieved by MEEKC with charged droplets, by MEKC or by formamide‐based NACE. Comparing the separations with respect to separation selectivity, substantial changes in migration order could be observed between the different techniques. Regarding separation efficiency, the number of theoretical plates and limits of detection (LOD) have been compared. The best LODs were achieved using SDS as surfactant in MEKC, followed by MEEKC.  相似文献   

13.
微乳液毛细管电动色谱研究   总被引:2,自引:0,他引:2  
傅小芸  吕建德  竺安 《化学学报》1997,55(5):503-507
本文研究了两组混合样的微乳液毛细管电动色谱(MEEKC)分离, 较系统地研究了微乳液的内相, 助表面活性剂及其浓度对电动分离的迁移时间、柱效及时间窗的影响, 并与胶束毛细管电动色谱(MEKC)分离进行了比较, 选用由80mmol/L正辛烷-120mmol/L十二烷基硫酸钠-900mmol/L正丁醇-10mmol/L硼砂组成的微乳液, 样品组分电动色谱迁移时间的RSD<0.8%, 峰面积RSD<3.0%.  相似文献   

14.
Microemulsion EKC (MEEKC) was developed for quantitative analysis of curcuminoids, such as curcumin (C), demethoxycurcumin (D), and bis-demethoxycurcumin (B). MEEKC separation of curcuminoids was optimized, and a change in resolution was explained using a modified equation for resolution in MEEKC without electroosmosis. The suitable MEEKC conditions for separation of curcuminoids were obtained to be the microemulsion buffer containing 50 mM phosphate buffer at pH 2.5, 1.1% v/v n-octane as oil droplets, 180 mM SDS as surfactant, 890 mM 1-butanol as cosurfactant, and 25% v/v 2-propanol as organic cosolvent; applied voltage of -15 kV; and separation temperature 25 degrees C. Achieved baseline resolution of C:D and D:B was obtained with R(s) -2.4 and analysis time within 18 min. In addition, high accuracy and precision of the method were obtained. This MEEKC method was used for quantitative determination of individual curcuminoids in medicinal turmeric capsules and powdered turmeric used as coloring additive in food, with simple sample preparation such as solvent extraction, dilution, and filtration, and without cleaning up by SPE.  相似文献   

15.
Microemulsion electrokinetic chromatography (MEEKC) was carried out in a pH 2.5 phosphate buffer to effectively suppress the electroosmotic flow (EOF). With 66.6% (w/w) 25 mM phosphate buffer pH 2.5, 20.0% (w/w) 2-propanol, 6.6% (w/w) 1-butanol, 6.0% (w/w) sodium lauryl sulphate (SDS), and 0.8% (w/w) n-octane as the separation medium, the fat-soluble vitamins A palmitate, E acetate, and D3 were baseline separated within 11 min. With strongly suppressed EOF, the polarity of the separation voltage was reversed (positive electrode at the outlet); the n-octane micro droplets surrounded by negatively charged SDS molecules migrated towards the detector. The aqueous part of the microemulsion was modified with 20% (w/w) 2-propanol to improve partition between the n-octane phase and the surrounding aqueous medium. The fat-soluble vitamins were separated in order of decreasing hydrophobicity with a high migration time stability (repeatable within 0.1% RSD). Excellent accuracy and precision were obtained when the system was applied for the determination of vitamin E acetate in commercial vitamin tablets; quantitative data corresponded to 97.0% of label claim, intra-day results varied within 1.72% RSD (n=6), and inter-day results varied within 3.22% RSD (n=5).  相似文献   

16.
In this study, microemulsion electrokinetic chromatography (MEEKC) and micellar electrokinetic chromatography (MEKC) were compared for their abilities to separate and detect thirteen phenolic compounds (syringic acid, p-coumaric acid, vanillic acid, caffeic acid, gallic acid, 3,4-dihydroxybenzoic acid, 4-hydroxybenzoic acid, (+)-catechin, (-)-epigallocatechin, (-)-epicatechin gallate, (-)-epigallocatechin gallate, (-)-epicatechin, and (-)-gallocatechin), and two other ingredients (caffeine and theophylline) in teas and grapes. Separation of phenolic compounds was improved by changing the SDS concentration for MEEKC, but the SDS concentration rarely affected the resolution for MEKC. Organic modifier (acetonitrile or methanol) was found to markedly influence the resolution and selectivity for both MEEKC and MEKC systems. In addition, a higher voltage and a higher column temperature improved the separation efficiency without any noticeable reduction in resolution for MEEKC whereas they caused a poor resolution for the MEKC system. Although separations with baseline resolution were achieved by the optimized MEEKC and MEKC methods, the separation selectivity resulting from the proposed MEEKC method was completely different from that of MEKC.  相似文献   

17.
Microemulsion electrokinetic chromatography (MEEKC) has been applied to the separation of some UV filters (Eusolex 4360, Eusolex 6300, Eusolex OCR, Eusolex 2292, Eusolex 6007, Eusolex 9020, Eusolex HMS, Eusolex OS, and Eusolex 232) commonly found in suntan lotions. The composition of the microemulsion employed was optimized with respect to the best possible separation of the selected analytes using artificial neural networks (ANNs). Two parameters namely the composition of the mixed surfactant system comprising the anionic sodium dodecyl sulfate (SDS) and neutral Brij 35 and the amount of organic modifier (2-propanol) present in the aqueous phase of the microemulsion were modeled. Using an optimized MEEKC buffer consisting of 2.25 g SDS, 0.75 g Brij 35, 6.6 g 1-butanol, 0.8 g n-octane, 17.5 g 2-propanol, and 72.1 g of 10 mM borate buffer (pH 9.2), eight target analytes could be separated in under 25 min employing a diode-array detector to segregate the overlapping signals obtained for Eusolex 9020 and Eusolex HMS. Detection limits from 0.8 to 6.0 nug/mL were obtained and the calibration plots were linear over at least one order of magnitude. The optimized method could be applied to the determination of Eusolex 6300 and Eusolex 9020 in a commercial suntan lotion.  相似文献   

18.
考察了用微乳液毛细管电动色谱(MEEKC)分离蛋白质时微乳液组成等不同因素对分离的影响,并与胶束电动色谱进行对比,探讨了其分离机理,为蛋白质的分离鉴定提供了一种有力的工具.  相似文献   

19.
Li Q  Chang CK  Huie CW 《Electrophoresis》2005,26(17):3349-3359
The effects of organic solvents on the capillary electrophoresis (CE) separation of a number of important biological porphyrin methyl esters - six weakly basic, hydrophobic cyclic tetrapyrroles possessing two and four to eight methyl ester groups around the periphery of the porphyrin ring - were investigated in the mode of micellar electrokinetic chromatography (MEKC), microemulsion electrokinetic chromatography (MEEKC), and nonaqueous CE. In aqueous MEKC, partial separation of the six neutral porphyrin methyl esters was obtained with an organic modifier (acetonitrile) in the concentration range between 20 and 40%, in which sodium dodecyl sulfate (SDS) molecules might be present in the form of SDS micelles and/or SDS micelle-like aggregates. Relatively stable SDS micelles can be formed in nonaqueous MEKC using formamide as the separation medium, but the separation of the target analytes remained unsatisfactory. Improved resolution of all six porphyrin methyl esters was obtained using MEEKC with the running buffer consisting of 0.8% w/w n-heptane (oil phase), 2.25% w/w SDS and 1.0% w/w Brij 35 (mixed surfactant), 6.6% w/w 1-butanol (cosurfactant), and 30% v/v 2-propanol (second cosurfactant), but reproducibility in terms of peak areas for certain porphyrins (especially uroporphyrin I octamethyl ester) was found to be very poor. Best separation performances were achieved with nonaqueous CE separations in which the weakly basic porphyrin methyl esters were protonated under strongly acidic conditions (e.g., using 10 mM perchloric acid) in mixed organic solvents. For example, using a 50:50 mixture of methanol and acetonitrile as the separation medium, baseline separation of all six (positively charged) porphyrin methyl esters can be obtained within 3 min and the average precision (RSD, N = 13) in terms of migration time and peak area were 0.55 and 2.16%, respectively.  相似文献   

20.
Micellar electrokinetic chromatography (MEKC) and microemulsion electrokinetic chromatography (MEEKC) are two kinds of electrokinetic capillary chromatography (EKC), which are characterized of high solubilization capacity and separation efficiency. In our previous work, some polar organic compounds and hydrophobic neutral compounds were separated successfully by EKC1-3. In this paper, these methods were used for separating six pyridoncarboylxic acid derivatives with similar structures. T…  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏