首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Gezici O  Kara H 《Talanta》2011,85(5):2405-2410
In the present study, metal binding property of humic acid (HA) was successfully adapted to the ligand-exchange concept, and metal-loaded immobilized humic acid was used as a ligand exchanger stationary phase for separation of some nucleosides. Humic-acid bonded aminopropyl silica (EC-HA-APS) was turned into ligand exchanger forms by loading aqueous solutions of Cu2+, and Co2+ to the column (4.6 × 150; as mm) packed with EC-HA-APS. Metal ion solutions were loaded to the column in a stepwise manner where the concentration of metal ion solution being loaded to the column was increased gradually between 5 and 100 mM. The progress of metal loading process was monitored via the breakthrough curves propagated stepwise. Ligand-exchange chromatography (LEC) studies were performed on an HPLC system, and chromatographic behaviors of the studied nucleosides (i.e. uridine, Urd; thymidine, Tyd; cytidine, Cyd; adenosine, Ado; and guanosine, Guo) were investigated on Cu2+ and Co2+ loaded forms of the EC-HA-APS (Cu-EC-HA-APS and Co-EC-HA-APS). Effect of mobile phase composition, temperature, and the type of metal ion loaded to the column on the retentive behaviors of the compounds was studied, in detail. The studied solutes exhibited mixed-mode RPLC/LEC behavior on the stationary phase. Metal-loaded column (M-EC-HA-APS) was easily regenerated into its original form, EC-HA-APS, with 98 ± 2% metal recoveries, by using aqueous mixture of EDTA + NH3 at pH = 7.5. Thus, the stationary phase exhibited a high flexibility between RPLC and LEC modes. This property, also, made it possible to convert the stationary phase into various ligand exchanger forms by loading different metal ions. Hence, capacity and selectivity of the stationary phase towards the studied species was manipulated easily by loading different metal ions to the stationary phase. Baseline separation for the studied species was achieved on Cu-EC-HA-APS and Co-EC-HA-APS and some differentiations were observed in capacity and selectivity, depending on the type of metal loaded. Thus, being as the first endeavor on usability of immobilized HA as a ligand exchanger stationary phase, the present study is believed to be useful to understand multifunctional character of HA-based solid/stationary phases.  相似文献   

3.
Counter-current chromatography (CCC) works with a support-free liquid stationary phase. This allows for preparative separations and purifications. However, there are serious technical constraints because of the need to keep a liquid stationary phase in a column. Centrifugal fields are used. A new commercial hydrodynamic 18 mL column made with a narrow-bore 0.8 mm Teflon tubing was evaluated by comparing it with older hydrodynamic CCC columns and a similar 19 mL column but made with 1.6 mm Teflon tubing. A small-volume CCC column allows for reliable and fast solute partition coefficient determination. When resolution is required, both high efficiency and liquid stationary phase retention are needed. Unfortunately, these two requirements bear technical contradictions. A column coiled with a narrow tubing bore will provide a high chromatographic efficiency while a column containing wider tubing bore will achieve higher stationary phase retention. In all cases, increasing the magnitude of the centrifugal field also increases the stationary phase retention. The solution is to build centrifuges able to produce high fields that will provide acceptable liquid phase retention with narrow-bore tubes. The new 18 mL 0.8 mm tubing bore column is able to rotate as fast as 2100 rpm generating a 240 × g field. The two older CCC columns cannot compete with the new one. However, the small 19 mL column with 1.6 mm bore tubing can be useful when fast results are desired without top resolution.  相似文献   

4.
A novel stationary phase prepared by the thermal immobilization of poly(dimethylsiloxane) onto the surface of silica (PDMS–SiO2) has been described, evaluated and compared with 229 commercially available RP-LC stationary phases using the Tanaka column classification protocol. The phase exhibited many unique chromatographic properties and, based on the phases in the database, was most similar to the fluoroalkylated phases (aside from the obvious lack of fluoro selectivity imposed by the C–F dipole). The phase exhibited classic reversed-phase behaviour in acid mobile phase conditions and mixed-mode reversed-phase/cation-exchange retention behaviour in neutral mobile phase conditions. The phase exhibited acceptable stability at both low and intermediate pH, conditions which should impart optimum chromatographic selectivity to the phase. Retention of basic analytes was shown to occur by a “three site model” as proposed by Neue. This new PDMS–SiO2 stationary phase is extremely interesting in that the dominancy of its hydrophobic and ion-exchange interactions can be controlled by the influence of mobile phase pH, buffer type and concentration. The PDMS–SiO2 stationary phase may provide a complementary tool to reversed-phase and HILIC stationary phases. The present results highlight the fact that the type of buffer, its concentration and pH can not only affect peak shape but also retention, selectivity and hence chromatographic resolution. Therefore, in method development and optimization strategies it is suggested that more emphasis should be given to the evaluation of these mobile phase operating parameters especially when basic solutes are involved.  相似文献   

5.
Jin G  Zhang B  Tang Y  Zuo X  Wang S  Tang J 《Talanta》2011,84(3):644-650
A triazolam-imprinted silica microsphere was prepared by combining a surface molecular-imprinting technique with the sol-gel process. The results illustrate that the triazolam-imprinted silica microspheres provided using γ-aminopropyltriethoxysilane and phenyltrimethoxysilane as monomers exhibited higher selectivity than those provided from γ-aminopropyltriethoxysilane and methyltriethoxysilane. In addition, the optimum affinity occurred when the molar ratio of γ-aminopropyltriethoxysilane, phenyltrimethoxysilane, and the template molecule was 4.2:4.7:0.6. Retention factor (k) and imprinting factor (IF) of triazolam on the imprinted and non-imprinted silica microsphere columns were characterized using high performance liquid chromatography (HPLC) with different mobile phases including methanol, acetonitrile, and water solutions. The molecular selectivity of the imprinted silica microspheres was also evaluated for triazolam and its analogue compounds in various mobile phases. The better results indicated that k and IF of triazolam on the imprinted silica microsphere column were 2.1 and 35, respectively, when using methanol/water (1/1, v/v) as the mobile phase. Finally, the imprinted silica was applied as a sorbent in solid-phase extraction (SPE), to selectively extract triazolam and its metabolite, α-hydroxytriazolam, from human urine samples. The limits of detection (LOD) for triazolam and α-hydroxytriazolam in urine samples were 30 ± 0.21 ng mL−1 and 33 ± 0.26 ng mL−1, respectively.  相似文献   

6.
Summary -cyclodextrin was used in the mobile phase as chiral selector for separating the enantiomers of terbutaline, chlorthalidone and oxazepam. The effect on chiral resolution using e.g. hydrophobic, polar or cation exchanging stationary phases was investigated. Both the chiral separation factor and retention level were affected by the concentration of methanol and -cyclodextrin. The stationary phase had no effect on the chiral separation only on the level of retention. By tuning the concentration of -cyclodextrin and methanol in the mobile phase chiral separation could be obtained on most stationary phases. By changing the stationary phase while adjusting the mobile phase composition to maintain the chiral selectivity, improvements of the selectivity towards e.g. endogenous compounds can be obtained when separating enantiomers in complex matrixes as biological fluids. Further improvement on selectivity can be obtained if coupled columns are used. This is examplified for separation of chlorthalidone and terbutaline enantiomers in biological fluids by coupling an achiral column to another achiral column and using a mobile phase containing -cyclodextrin on the last column.  相似文献   

7.
The performance of the coiled column of centrifugal counter-current chromatography was investigated by changing the angle between column axis and centrifugal force in the separation of dipeptides or DNP-amino acids each with suitable two-phase solvent systems. In general, retention of the stationary phase (Sf) decreased, and peak resolution (Rs) increased as the column angle was increased. The first series of experiments was performed using a polar two-phase solvent system composed of 1-butanol–acetic acid–water (4:1:5, v/v/v) to separate two dipeptide samples, Trp-Tyr and Val-Tyr, at a flow rate of 1 ml/min at 1000 rpm. When the column angle was changed from 0° to 90°, Rs increased from 1.05 (Sf = 60.1%) to 1.17 (Sf = 38.7%) with the lower phase mobile and from 1.02 (Sf = 67.8%) to 1.14 (Sf = 47.4%) with the upper phase mobile, respectively. The second series of experiments was similarly performed with a more hydrophobic two-phase solvent system composed of hexane–ethyl acetate–methanol–0.1 M hydrochloric acid (1:1:1:1, v/v/v/v) to separate three DNP-amino acids, DNP-glu, DNP-β-ala and DNP-ala, at a flow rate of 1 ml/min at 1000 rpm. When the column angle was changed from 0° to 90°, Rs increased from 1.38 (1st peak/2nd peak) and 1.20 (2nd peak/3rd peak) (Sf = 61.1%) to 1.66 and 1.45 (Sf = 34.4%) with the lower phase mobile and from 1.14 and 0.63 (Sf = 72.2%) to 1.53 and 0.87 (Sf = 51.1%) with the upper phase mobile, respectively. The overall results of our studies indicate that increasing the column angle against the radially acting centrifugal force enhances the mixing of two phases in the column to improve the peak while decreasing the stationary phase retention by interrupting the laminar flow of the mobile phase.  相似文献   

8.
A chiral separation method for glycidol enantiomers determination by normal-phase high-performance liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry was developed. Two chiral stationary phases, amylose tris-(3,5-dimethylphenylcarbamate) (Chiralpak AD-H) and (S)-indoline-2-carboxylic acid and (R)-1-(α-naphthyl) ethylamine (SUMICHIRAL OA-4900) have been investigated. The effects of the mobile phase composition, elution program and column temperature were also studied. Under the best conditions: Chiralpak AD-H column, mobile phase composition n-hexane:ethanol (70:30, v/v), flow rate of 0.8 mL/min and 40 °C column temperature, a good resolution (Rs = 1.6) for both enantiomers has been achieved with an analysis time of 16 min. The method was found to be linear in the range from 100 to 500 ppm for both glycidol enantiomers with a good determination coefficient (r2 higher than 0.99) and good precision. Limits of detection of 31 and 50 ppm for (R)-(+)-glycidol and (S)-(−)-glycidol, respectively, were obtained. The method was applied to the determination of the enantiomeric excess and yield obtained in a asymmetric epoxidation process of allyl alcohol with a chiral titanium-tartrate complex as catalyst.  相似文献   

9.
The retention characteristics of phenyl type stationary phases for reversed phase high performance liquid chromatography are still largely unknown. This paper explores the retention process of these types of stationary phases by examining the retention behaviour of linear PAHs and n-alkylbenzenes on a series of propyl phenyl stationary phases that have changes in their ligand density (1.23, 1.31, 1.97, 2.50 μmol m−2). The aromatic and methylene selectivities increased with increasing ligand density until a point where a plateau was observed, overall the propyl phenyl phases had a higher degree of aromatic selectivity than methylene selectivity indicating that these columns are suitable for separations involving aromatic compounds. Also, retention characteristics relating to the size of the solute molecule were observed to be influenced by the ligand density. It is likely that the changing retention characteristics are caused by the different topologies of the stationary phases at different ligand densities. At high ligand densities, the partition coefficient became constant.  相似文献   

10.
The system constants of the solvation parameter model are used to prepare system maps for the retention of small neutral compounds on an octylsiloxane-bonded (Kinetex C8) and diisobutyloctadecylsiloxane-bonded (Kinetex XB-C18) superficially porous silica stationary phases for aqueous mobile phases containing 10–70% (v/v) methanol or acetonitrile. Electrostatic interactions (cation-exchange) are important for the retention of weak bases with acetonitrile–water but not for methanol–water mobile phases. Compared with an octadecylsiloxane-bonded silica stationary phase (Kinetex C18) retention is reduced due to a less favorable phase ratio for both the octylsiloxane-bonded and diisobutyloctadecylsiloxane-bonded silica stationary phases while selectivity differences are small and solvent dependent. Selectivity differences for neutral compounds are larger for methanol–water but significantly suppressed for acetonitrile–water mobile phases. The selectivity differences arise from small changes in all system constants with solute size and hydrogen-bond basicity being the most important due to their dominant contribution to the retention mechanism. Exchanging the octadecylsiloxane-bonded silica column for either the octylsiloxane-bonded or diisobutyloctadecylsiloxane-bonded silica column affords little scope for extending the selectivity space and is restricted to fine tuning of separations, and in some cases, to obtain faster separations due to a more favorable phase ratio. For weak bases larger differences in relative retention are expected with acetonitrile–water mobile phases on account of the additional cation exchange interactions possible that are absent for the octadecylsiloxane-bonded silica stationary phase.  相似文献   

11.
The nature and extent of mixed-mode retention mechanisms evident for three structurally related, agglomerated, particle-based stationary phases were evaluated. These three agglomerated phases were Thermo Fisher ScientificIon PacAS11-HC – strong anion exchange, Thermo Fisher Scientific IonPac CS10 – strong cation-exchange PS-DVB, and the Thermo Fisher Scientific Acclaim Trinity P1silica-based substrate, which is commercially marketed as a mixed-mode stationary phase. All studied phases can exhibit zwitterionic and hydrophobic properties, which contribute to the retention of charged organic analytes. A systematic approach was devised to investigate the relative ion-exchange capacities and hydrophobicities for each of the three phases, together with the effect of eluent pH upon selectivity, using a specifically selected range of anionic, cationic and neutral aromatic compounds. Investigation of the strong anion-exchange column and the Trinity P1 mixed-mode substrate, in relation to ion-exchange capacity and pH effects, demonstrated similar retention behaviour for both the anionic and ampholytic solutes, as expected from the structurally related phases. Further evaluation revealed that the ion-exchange selectivity of the mixed-mode phase exhibited properties similar to that of the strong anion-exchange column, with secondary cation-exchange selectivity, albeit with medium to high anion-exchange and cation-exchange capacities, allowing selective retention for each of the anionic, cationic and ampholytic solutes. Observed mixed-mode retention upon the examined phases was found to be a sum of anion- and cation-exchange interactions, secondary ion-exchange and hydrophobic interactions, with possible additional hydrogen bonding. Hydrophobic evaluation of the three phases revealed log P values of 0.38–0.48, suggesting low to medium hydrophobicity. These stationary phases were also benchmarked against traditional reversed-phase substrates namely, octadecylsilica YMC-Pac Pro C18 and neutral μPS-DVB resin IonPac NS1-5u, yielding log P values of 0.57 and 0.52, respectively.  相似文献   

12.
A method for preparation of a stationary phase-adjustable column with in-column stationary phase-coated fused-silica fiber annular column was successfully developed. The surface of a 0.12 mm o.d. bare optical fiber was first coated with a stationary phase and then inserted into a fused-silica capillary (non-coated or coated) as an annular column for gas chromatographic study. The optical fiber and capillary were coated with polydimethylsiloxane (SE-30) and polyethylene glycol 20M (PEG-20M) as nonpolar and polar stationary phases, respectively. Among the investigated annular and open tubular columns, the PEG-20M-coated fiber-in-PEG-20M-coated capillary annular column showed the highest column efficiency with a minimum plate height of 0.35 mm and an optimum gas velocity of 25 cm/s. When a SE-30/PEG-20M-coated fiber-in-uncoated capillary annular column was applied to separate a 9-component complex mixture, the total analysis time was 5.3 min and the column length was 12 m. By contrast, when a SE-30-coated fiber-in-PEG-20M-coated capillary annular column was used to separate the same 9-component mixture, the analysis time was reduced to 3.5 min and the column length was shortened by half to 6 m. Our results show that the stationary phase-coated fiber-in-stationary phase-coated capillary annular column is a better choice for gas chromatographic separation as it is more efficient and flexible. In addition, the proposed annular column design provides flexibility in using two or even more types of stationary phases to achieve optimal analytical separation.  相似文献   

13.
There are various reversed‐phase stationary phases that offer significant differences in selectivity and retention. To investigate different reversed‐phase stationary phases (aqueous stable C18, biphenyl, pentafluorophenyl propyl, and polar‐embedded alkyl) in an automated fashion, commercial software and associated hardware for mobile phase and column selection were used in conjunction with liquid chromatography and a triple quadrupole mass spectrometer detector. A model analyte mixture was prepared using a combination of standards from varying classes of analytes (including drugs, drugs of abuse, amino acids, nicotine, and nicotine‐like compounds). Chromatographic results revealed diverse variations in selectivity and peak shape. Differences in the elution order of analytes on the polar‐embedded alkyl phase for several analytes showed distinct selectivity differences compared to the aqueous C18 phase. The electron‐rich pentafluorophenyl propyl phase showed unique selectivity toward protonated amines. The biphenyl phase provided further changes in selectivity relative to C18 with a methanolic phase, but it behaved very similarly to a C18 when an acetonitrile‐based mobile phase was evaluated. This study shows the value of rapid column screening as an alternative to excessive mobile phase variation to obtain suitable chromatographic settings for analyte separation.  相似文献   

14.
Differences in the system constants of the solvation parameter model and retention factor correlation plots for varied solutes are used to study the retention mechanism on XBridge C8, XBridge Phenyl and XTerra Phenyl stationary phases with acetonitrile–water and methanol–water mobile phases containing from 10 to 70% (v/v) organic solvent. These stationary phases are compared with XBridge C18 and XBridge Shield RP18 characterized in an earlier report using the same protocol. The XBridge stationary phases are all quite similar in their retention properties with larger difference in absolute retention explained by differences in cohesion and the phase ratio, mainly, and smaller changes in relative retention (selectivity) by the differences in individual system constants and their variation with mobile phase type and composition. None of the XBridge stationary phases are selectivity equivalent but XBridge C18 and XBridge Shield RP18 have similar separation properties, likewise so do XBridge C8 and XBridge Phenyl, while the differences between the two groups of two stationary phases is greater than the difference within either group. The limited range of changes in selectivity is demonstrated by the high coefficient of determination (>0.98) for plots of the retention factors for varied compounds on the different XBridge phases with the same mobile phase composition.  相似文献   

15.
Hydrophilic interaction liquid chromatography (HILIC) is a fast growing separation technique for hydrophilic and polar analytes. In this work, we combine the unique selectivity of carbon surfaces with the high efficiency of core–shell silica. First, 5 μm core–shell silica is electrostatically coated with 105 nm cationic latex bearing quaternary ammonium groups. Then 50 nm anionic carbon nanoparticles are anchored onto the surface of the latex coated core–shell silica particles to produce a hybrid carbon–silica phase. The hybrid phase shows different selectivity than ten previously classified HILIC column chemistries and 36 stationary phases. The hybrid HILIC phase has shape selectivity for positional isomeric pairs (phthalic/isophthalic and 1-naphthoic/2-naphthoic acids). Fast and high efficiency HILIC separations of biologically important carboxylates, phenols and pharmaceuticals are reported with efficiencies up to 85,000 plates m−1. Reduced plate height of 1.9 (95,000 plates m−1) can be achieved. The hybrid phase is stable for at least 3 months of usage and storage under typical HILIC eluents.  相似文献   

16.
The system constants of the solvation parameter model are used to prepare system maps for the retention of small neutral compounds on phenylhexylsiloxane- and pentafluorophenylpropylsiloxane-bonded superficially porous silica stationary phases (Kinetex Phenyl-Hexyl and Kinetex F5) for aqueous mobile phases containing 10–70% (v/v) methanol or acetonitrile. Electrostatic interactions (cation exchange) are important for the retention of weak bases for acetonitrile–water mobile phases, but virtually absent for the same compounds for methanol–water mobile phases. The selectivity of the Kinetex Phenyl-Hexyl stationary phase for small neutral compounds is similar to an octadecylsiloxane-bonded silica stationary phase with similar morphology Kinetex C-18 for both methanol–water and acetonitrile–water mobile phase compositions. The Kinetex Phenyl-Hexyl and XBridge Phenyl stationary phases with the same topology but different morphology are selectivity equivalent, confirming that solvation of the interphase region can be effective at dampening selectivity differences for modern stationary phases. Small selectivity differences observed for XTerra Phenyl (different morphology and topology) confirm previous reports that the length and type of space arm for phenylalkylsiloxane-bonded silica stationary phases can result in small changes in selectivity. The pentafluorophenylpropylsiloxane-bonded silica stationary phase (Kinetex F5) has similar separation properties to the phenylhexylsiloxane-bonded silica stationary phases, but is not selectivity equivalent. However, for method development purposes, the scope to vary separations from an octadecylsiloxane-bonded silica stationary phase (Kinetex C-18) to “phenyl phase” of the types studied here is limited for small neutral compounds. In addition, selectivity differences for the above stationary phases are enhanced by methanol–water and largely suppressed by acetonitrile–water mobile phases. For bases, larger selectivity differences are possible for the above stationary phases if electrostatic interactions are exploited, especially for acetonitrile-containing mobile phases.  相似文献   

17.
A new method for the fixation of polymethacrylate monoliths within titanium tubing of up to 0.8 mm I.D. for use as a chromatographic column under elevated temperatures and pressures is described. The preparation of butyl methacrylate–ethylene dimethacrylate-based monolithic stationary phases with desired porous structures was achieved within titanium tubing with pre-oxidised internal walls. The oxidised titanium surface was subsequently silanised with 3-trimethoxysilylpropyl methacrylate resulting in tight bonding of butyl methacrylate porous monolith to the internal walls, providing stationary phase stability at column temperatures up to 110 °C and at operating column pressure drops of >28 MPa. The titanium housed monoliths exhibited a uniform and dense porous structure, which provided peak efficiencies of up to 59,000 theoretical plates per meter when evaluated for the separation of small molecules in reversed-phase mode, under optimal conditions (achieved at 15 μL/min and temperature of 110 °C for naphthalene with a retention factor, k = 0.58). The developed column was applied to the reversed-phase isocratic separation of a text mixture of pesticides.  相似文献   

18.
We investigated the effects of the concentration of naphthalene sulphonic acids (NSAs) as anionic test compounds in the injected sample and of the salt additives to the mobile phase on ion-exclusion. The retention behaviour of NSAs sensitively reflects even minor changes in the ionic and hydrophobic interactions and can be useful for predicting the effects of the stationary phases in reversed-phase chromatography of polar and ionic compounds, both small ones and biopolymers, e.g., oligonucleotides. We studied chromatographic properties of several stationary phases intended for separations in aqueous mobile phases: a C18 column end-capped with polar hydrophilic groups, a densely bonded C8 column doubly end-capped with short alkyl groups, a short alkyl stationary phase designed to keep full pore accessibility in highly-aqueous mobile phases and a Bidentate column with “bridged” C18 groups attached to the silica hydride support. The chemistry and pore structure of various types of column packing materials and of the salt additives to the mobile phase affect the proportion of the pore volume non-accessible to anions due to ion-exclusion and consequently the peak asymmetry and hydrophobic selectivity in reversed-phase chromatography of organic acids. We also addressed the problems connected with the determination of column hold-up volume in aqueous mobile phases. The accessibility of the stationary phase for anionic compounds in contact with the sample zone is affected by ion-exclusion due to repulsive interactions with the negatively charged surface in the pores of the stationary phase. The accessible part of the stationary phase increases and consequently the migration velocity along the column decreases with increasing concentration of the sample in the zone moving along the column. Because of a limited access to the stationary phase, its capacity can be easily overloaded. The combination of the column overload and ion-exclusion effects may result in fronting or tailing peak asymmetry. To explain this behaviour, we proposed a modified Langmuir model, respecting the variation of the column capacity due to the effects of sample concentration on ion-exclusion.  相似文献   

19.
Combined effects of temperature and mobile phase on the reversed phase chromatographic behavior of alkylbenzenes and simple substituted benzenes were investigated on a Blaze C8 polydentate silica-based column, showing improved resistance against hydrolytic breakdown at temperatures higher than 60 °C, in comparison to silica-based stationary phases with single attachment sites. For better insight into the retention mechanism on polydentate columns, we determined the enthalpy and entropy of the transfer of the test compounds from the mobile to the stationary phase. The enthalpic contribution dominated the retention at 80% or lower concentrations of methanol in the mobile phase. Entropic effects are more significant in 90% methanol and in acetonitrile–water mobile phases. Anomalies in the effects of mobile phase on the enthalpy of retention of benzene, methylbenzene and polar benzene derivatives were observed, in comparison to regular change in enthalpy and entropy of adsorption with changing concentration of organic solvent and the alkyl length for higher alkylbenzenes. The temperature and the mobile phase effects on the retention are practically independent of each other and – to first approximation – can be described by a simple model equation, which can be used for optimization of separation conditions.  相似文献   

20.
Hongzhe Tian 《Talanta》2007,72(2):813-818
The effect of axial temperature gradient (ATG) along a microcolumn on the separation performance at both isocratic and gradient elution mode was investigated. A thermostat system was designed to form an ATG along the packed column. Polycyclic aromatic hydrocarbons (PAHs) were separated on a 0.53 mm  × 150 mm i.d. 5 μm C18 microcolumn, with water and acetonitrile as mobile phase. The separation results obtained at mobile phase gradient (MPG) and ATG in microcolumn HPLC were compared with the results performed at ambient conditions. Extrapolated curves of peak width at half height (wh)versus lnk showed that wh is narrower at the same retention time when ATG was applied in addition to MPG. The column efficiency was enhanced 20-30% and the resolution was slightly reduced because of reduction of selectivity at elevated temperature at ATG condition. The RSD of retention time in ATG mode was less than 2.5%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号