首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Indium tin oxide (ITO) films as the low emissivity coatings of Ni-based alloy at high temperature were studies. ITO films were deposited on the polished surface of alloy K424 by direct current magnetron sputtering. These ITO-coated samples were heat-treated in air at 600–900 °C for 150 h to explore the effect of high temperature environment on the emissivity. The samples were analyzed by X-ray diffraction (XRD), SEM and EDS. The results show that the surface of sample is integrity after heat processing at 700 °C and below it. A small amount of fine crack is observed on the surface of sample heated at 800 °C and Ti oxide appears. There are lots of fine cracks on the sample annealed at 900 °C and a large number of various oxides are detected. The average infrared emissivities at 3–5 μm and 8–14 μm wavebands were tested by an infrared emissivity measurement instrument. The results show the emissivity of the sample after annealed at 600 and 700 °C is still kept at a low value as the sample before annealed. The ITO film can be used as a low emissivity coating of super alloy K424 up to 700 °C.  相似文献   

2.
The aim of the present study was to compare infrared thermography and thermal contact sensors for measuring skin temperature during cycling in a moderate environment. Fourteen cyclists performed a 45-min cycling test at 50% of peak power output. Skin temperatures were simultaneously recorded by infrared thermography and thermal contact sensors before and immediately after cycling activity as well as after 10 min cooling-down, representing different skin wetness and blood perfusion states. Additionally, surface temperature during well controlled dry and wet heat exchange (avoiding thermoregulatory responses) using a hot plate system was assessed by infrared thermography and thermal contact sensors. In human trials, the inter-method correlation coefficient was high when measured before cycling (r = 0.92) whereas it was reduced immediately after the cycling (r = 0.82) and after the cooling-down phase (r = 0.59). Immediately after cycling, infrared thermography provided lower temperature values than thermal contact sensors whereas it presented higher temperatures after the cooling-down phase. Comparable results as in human trials were observed for hot plate tests in dry and wet states. Results support the application of infrared thermography for measuring skin temperature in exercise scenarios where perspiration does not form a water film.  相似文献   

3.
This work strived to model the effect of surface oxidization and nitridation on the normal spectral emissivity of Ti–6Al–4V alloys at a temperature range of 800–1100 K and a wavelength of 1.5 μm. In experiments, the detector was as close to perpendicular to the surface of the specimens as possible so that only the normal spectral emissivity was measured. Two thermocouples were symmetrically welded near the measuring area for accurate measuring and monitoring of the temperature at the surface of the specimen. The specimens were heated for 6 h at a certain temperature. During this period, the normal spectral emissivity values were measured once every 1 min during the initial 180 min, and once every 2 min thereafter. The measurements were made at certain temperatures from 800 to 1100 K in intervals of 20 K. One strong oscillation in the normal spectral emissivity was observed at each temperature. The oscillations were formed by the interference between the radiation stemming from the oxidization and nitridation layer on the specimen surface and radiation from the substrate. The uncertainty in the normal spectral emissivity caused only by the surface oxidization and nitridation was found to be approximately 9.5–22.8%, and the corresponding uncertainty in the temperature generated only by the surface oxidization and nitridation was approximately 6.9–15.5 K. The model can reproduce well the normal spectral emissivity, including the strong oscillation that occurred during the initial heating period.  相似文献   

4.
The main challenge of low infrared emissivity coatings based on aluminum flake lies in finding an efficient method to synthesize the composite pigment with low infrared emissivity and low lightness simultaneously. In this work, we overcome this constraint to some extent, synthesizing a novel Al/Co3O4 magnetic composite pigments with low infrared emissivity and low lightness by thermal cracking and hot flowing method. The results show that the covering area of Co3O4 on the aluminum flake can be tuned by the amount of CoCO3 adding in precursor and the reaction temperature of hot flowing, both of which pay a key factor on the VIS and IR spectral reflectance and magnetic properties. The magnetic Al/Co3O4 composite pigments with low lightness and low infrared emissivity can be obtained at 130 °C for 24 h in hot flowing liquid. The lightness L1 can be decreased to 69.2, however the infrared emissivity (8–14 μm) is also low to 0.45. Compared with the single Al flakes, Al/Co3O4 magnetic composite pigments present stronger magnetic properties. Therefore, the Al/Co3O4 magnetic composite pigments have offered new choice for the pigments of low infrared emissivity coatings.  相似文献   

5.
Non-contact temperature measurement in a nuclear reactor is still a huge challenge because of the numerous constraints to consider, such as the high temperature, the steam atmosphere, and irradiation. A device is currently developed at CEA to study the nuclear fuel claddings behavior during a Loss-of-Coolant Accident. As a first step of development, we designed and tested an optical pyrometry procedure to measure the surface temperature of nuclear fuel claddings without any contact, under air, in the temperature range 700–850 °C. The temperature of Zircaloy-4 cladding samples was retrieved at various temperature levels. We used Multispectral Radiation Thermometry with the hypothesis of a constant emissivity profile in the spectral ranges 1–1.3 µm and 1.45–1.6 µm. To allow for comparisons, a reference temperature was provided by a thermocouple welded on the cladding surface. Because of thermal losses induced by the presence of the thermocouple, a heat transfer simulation was also performed to estimate the bias. We found a good agreement between the pyrometry measurement and the temperature reference, validating the constant emissivity profile hypothesis used in the MRT estimation. The expanded measurement uncertainty (k = 2) of the temperature obtained by the pyrometry method was ±4 °C, for temperatures between 700 and 850 °C. Emissivity values, between 0.86 and 0.91 were obtained.  相似文献   

6.
The temperature measurements during the infrared cooking of the semi-cooked cylindrical minced beef product (koefte) were taken by both contact (thermocouples) and non-contact (thermal imaging) techniques. The meat product was semi-cooked till its core temperature reached up to 75 °C by ohmic heating applied at 15.26 V/cm voltage gradient. Then, infrared cooking was applied as a final cooking method at different combinations of heat fluxes (3.7, 5.7 and 8.5 kW/m2), applied distances (10.5, 13.5 and 16.5 cm) and applied durations (4, 8 and 12 min). The average surface temperature increased as the heat flux and the applied duration increased but the applied distance decreased. The temperature distribution of the surface during infrared cooking was determined successfully by non-contact measurements. The temperature homogeneity varied between 0.77 and 0.86. The process condition of 8.5 kW/m2 for 8 min resulted in core temperature greater than 75 °C, which was essential for safe production of ready-to-eat (RTE) meat products. Thermal imaging was much more convenient method for minimizing the point measurement mistakes and determining temperature distribution images more clear and visual.  相似文献   

7.
Infrared thermography is used for evaluation of the mean temperature as a measure of thermal load during corneal refractive surgery. An experimental method to determine emissivity and to calibrate the thermografic system is presented. In a case study on the porcine eye two dimensional temperature distributions with lateral resolution of 170 μm and line scans with temporal resolution of 13 μs are discussed with respect to the meaning of mean temperature. Using the newest generation of surgery equipment it is shown, that the mean temperature rise can be kept below 5 °C during myopic laser in situ keratomileusis (LASIK) treatments corresponding to an aberration-free correction of ?2.75 diopter.  相似文献   

8.
This study explores the spectral emissivity modeling of steel 201 during the growth of oxidation film over the temperature range from 800 to 1100 K at 1.5 μm. The radiance coming from the specimen is received by an InGaAs photodiode detector. The specimen temperature is obtained by averaging the two platinum–rhodium thermocouples, which are tightly welded in the front surface of specimen near the measuring area viewed by the detector. The variation of spectral emissivity with the temperature is studied at a given heating time. The variation of spectral emissivity with the heating time is evaluated at a definite temperature. The strong oscillations of spectral emissivity are observed and discussed in detail, which originate from the interference effect between the radiation stemming from the oxidization film on the specimen surface and the radiation coming from the specimen surface. The measurement uncertainties of spectral emissivity contributed only by the surface oxidization are about 3.2–14.1%. At a given heating time, the variation of spectral emissivity with the temperature abides well by a simple analytic functional form. And at a definite temperature, the variation of spectral emissivity with the heating time can also be well reproduced by fitting except for the periodical oscillations.  相似文献   

9.
A fast and easy method for fault detection in antenna arrays using infrared thermography is presented. A thin, minimally perturbing, microwave absorption screen made of carbon loaded polymer is kept close in front of the faulty array. Electromagnetic waves falling on the screen increase its temperature. This temperature profile on the screen is identical to electric field intensity profile at the screen location. There is no temperature rise observed on the screen corresponding to non-radiating (faulty) elements and hence can be easily detected by IR thermography. The array input power is modulated at a low frequency which permits thermography to detect even weak fields. It also improves the resolution of thermal images. The power fed to the array is only 30 dBm. In order to show the utility of this technique, an example of 14 GHz 4 × 4 patch antenna array is given. The simulations are carried in CST Microwave Studio 2013. A good agreement between simulation and experimental results is observed.  相似文献   

10.
The W doped VO2 thin films with various W contents were successfully deposited by aqueous sol-gel method followed by a post annealing process. The derived thin films were characterized by X-ray diffraction, Raman spectra, scanning electron microscopy and atomic force microscopy. Besides, the resistance-temperature relationship and infrared emissivity in the waveband 7.5–14 μm were analyzed, and the effects of W doping on the thermochromic properties of VO2 thin films were studied. The results show that W atoms enter the crystal lattice of VO2 and the transition temperature decreases gradually with increasing doping amount of W. The emissivity of VO2-W-4% thin films has dropped to 0.4 when its real temperature is above 30 °C. The thermal infrared images were also examined under different temperature by thermal imager. The results indicate that the temperature under which W doped VO2 thin films begin to have lower emissivity decreases gradually with increasing doping amount of W. W doped VO2 thin films can control its infrared radiation intensity actively at a lower temperature level of 30 °C, which has great application prospects in the adaptive infrared stealth technology.  相似文献   

11.
Specially created subsurface defects in a sample are detected using a high resolution infrared camera FLIR SC7000. A scanning hot air (about 110 °C) nozzle is applied to introduce additional energy in a researched sample. The hidden defect has an increased temperature in comparison with the surrounding area that is a result of changed emissivity and thermal diffusivity. The suggested method is compared with pulse thermography which uses a xenon lamp for excitation.  相似文献   

12.
《Current Applied Physics》2010,10(2):487-497
An infrared diagnosis device provides two-dimensional images and patient-oriented results that can be easily understood by the inspection target by using infrared cameras. However, this device has disadvantages such as large size, high price, and inconvenient maintenance. In this regard, this study has proposed a small diagnosis device for body heat using a single infrared sensor and implementing an infrared detection system using a single infrared sensor and an algorithm that represents thermography using the obtained data on the temperature of the point source. The developed system had a temperature resolution of 0.1 °C and reproducibility of ±0.1 °C. The accuracy was 90.39% at the error bound of ±0 °C and 99.98% at that of ±0.1 °C. To evaluate the proposed algorithm and system, the infrared images of the camera method were compared. To verify the device’s clinical applicability, thermal images with clinical meaning were obtained from a patient who had lesions.  相似文献   

13.
Effect of surface oxidization on the spectral emissivity of brass is studied over the temperature range from 800 to 1070 K at the wavelength of 1.5 μm. The temperature of brass surface is measured by averaging the two R-type platinum–rhodium thermocouples. The radiant energy emitted by the brass surface is received by an InGaAs photodiode detector. Two kinds of relationships between the spectral emissivity and the temperature are investigated in the oxidizing environment at the elevated temperature. One is the variation of spectral emissivity with the heating-duration time at the given temperature. The other is the variation of spectral emissivity with the temperature at the given heating-duration time. The interference effect of radiation coming from the brass surface and coming from the oxidization film is discussed when the oxidation film on the surface is grown. The resonant structures of spectral emissivity are observed during the whole heating period, in particular at the early stage of heating duration. The analytic formula of spectral emissivity versus the temperature is derived at the heating-duration time of 30, 60, 90, 120, 150, 180, 210, 240, 270 and 300 min, respectively. The conclusion is obtained that coefficients of analytic expressions between the spectral emissivity and the temperature are different from each other for the experimental results obtained at the different heating-duration time, though the polynomial functional form is suitable to fit all the measurements obtained in the present work.  相似文献   

14.
In a previous work, we succeeded in connecting normal LWIR apparent emissivity to the spectral one of an aluminum nitride ceramic plate. The key problem was the knowledge of the effective spectral bandwidth in use in the system. Hence we have developed an analyzer which permits to identify the spectral bandwidth of IR system using only its raw data. It proceeds by minimizing the dispersion from linearity of the characteristic thermosignals/integrated radiance over a temperature range of the IR system. The capacities of the analyzer are tested for five commercial cameras. Each of these systems exhibits a similar formatting process implemented during the thermogram recording. The effective spectral bandwidth shows plausible values. It varies significantly from one model to the other and the residual non-linearity is connected to the NETD of the IR system. The robustness of the apparent emissivity measurements is also tested with the aid of emissivity reference of 0.5. The overall accuracy of the method is less than 1%, depending on the specular or diffuse part of the reflected irradiation. Applied in field situation, the method is suitable to detect absolute variation of emissivity of less than 6  10−3. We use the analyzer to determine the spectral bandwidth of a commercial 320 × 240 microbolometer uncooled IRFPA camera which had already served to characterize the normal LWIR apparent emissivity of the aluminum nitride ceramic plate. By using the spectral response of the two major microbolometer sensor technologies, the general formulation of apparent emissivity matches our apparent emissivity measurements. An agreement better than 0.6% in absolute value and a less than 6  10−3%/°C dispersion are found over the entire temperature range [40–130 °C].  相似文献   

15.
In this paper we report on the growth of mid-wavelength infrared superlattice materials by molecular beam epitaxy. We focused on the effects of process parameters, such as arsenic beam equivalent pressure and shutter sequences, on the key material properties, such as the lattice mismatch and the surface morphology. Though a smaller As beam equivalent pressure helps to reduce the lattice mismatch between the superlattice and the GaSb substrate, the As beam equivalent pressure itself has a lower limit below which the material’s surface morphology will degrade. To achieve fully lattice-matched superlattice materials, a novel shutter sequence in the growth process was designed. With well-designed interface structures, a high quality P-I-N superlattice mid-infrared detector structure was realized. At 77 K the dark current density at −50 mV bias was 2.4 × 10−8 A/cm2 and the resistance-area product (RA) at maximum (−50 mV bias) was 2.4 × 106 Ω cm2, and the peak detectivity was then calculated to be 9.0 × 1012 cm Hz1/2/W. The background limited infrared photodetector (BLIP) level can be achieved at a temperature of 113 K.  相似文献   

16.
This paper presents the results of a study conducted to evaluate the possibility of utilizing infrared thermography to assess the quality of concrete. Concrete specimens were prepared with varying water to cement (w/c) ratio, cement content and consolidation effort. The concrete specimens were heated and the IRT images were recorded as they cooled down. The IR thermographs indicated a good variation in the surface temperature with varying concrete composition and consolidation effort. Concrete with similar composition exhibited a greater variation in surface temperature as the consolidation effort was decreased; indicating the presence of less dense structure in the specimens prepared with low consolidation effort. An increase in the water–cement ratio also increases the temperature variation indicating a decrease in the concrete denseness. The variation in cement content also influenced the denseness of concrete as indicated by the enhanced variation in the surface temperature. Concrete specimens with cement content of 300 kg/m3 (less dense) exhibited a greater temperature variation compared to those prepared with cement content of 400 kg/m3 (more dense).  相似文献   

17.
Lock-in and pulse phase infrared thermography measurement techniques have been exploited for quantitative assessment of subsurface defects in a reference specimen made of Plexiglas. Radiometric thermal images were post-processed using a contrast approach in the frequency domain, allowing defect depth to be resolved with a combined standard uncertainty of about 5% for thicknesses up to 3.6 mm. Conversely, significant radial heat diffusion next to the boundary of the discontinuities made accurate sizing of deeper subsurface defects more difficult, resulting in a combined standard uncertainty of about 17% for a 10 mm diameter flat-bottomed hole of 3.6 mm deep. The obtained results demonstrate the potentiality of active thermography as a fast, powerful contactless NDE measurement tool.  相似文献   

18.
6061 aluminum alloy was treated by MAO at various temperatures of the alkali silicate electrolyte using pulsed bipolar current mode for ten minutes. The surface microstructures and properties were studied using SEM, EDX, and XRD. The infrared emissivities of the MAO ceramic coatings were measured at the 70 °C using FTIR spectrometer. The electrolyte temperature strongly affected all the surface properties. The MAO alumina ceramics prepared in cold electrolytes have volcano-like and accumulated particles microstructures, while those prepared in hot electrolytes were: rougher, thinner and contained grainy spherical hollow bulgy microstructures with more pore density and more sillimanite and cristobalite phases which enhanced the IR emissivity. Also, the increment of sillimanite and cristobalite phases moved the apparent peaks toward longer wavelengths, and broadened the opaque region of the IR spectra. As a result, the increment of electrolyte temperature from 12.3 °C to 90.5 °C increased the average of LWIR emissivity from 80.4% to 94.4%, respectively, for the MAO ceramic coatings.  相似文献   

19.
Unexpected temperature rise is observed in end-pumped YAG–Nd3+:YAG–YAG slab laser experimentally. The measured optical absorption spectrum of undoped YAG in 780–830 nm indicates an absorption coefficient of 0.015 cm?1 at 808 nm. The influence of the weak absorption on temperature distribution in end-pumped composite slabs is analyzed numerically and a good agreement with infrared measurement is achieved. The results of finite element analysis show that longer heat sinks and wider slabs bring lower temperature.  相似文献   

20.
The multi-waveband temperature sensor (MWTS) array, in which each super-pixel (2 × 2 pixel cell) operates at four distinct thermal infrared (IR) wavebands is being developed. Using this high spatial resolution, four-band thermal IR band detector array, accurate temperature measurements on the surface of an object can be made without prior knowledge of its exact emissivity. This multi-band detector involves intersubband transition in III–V semiconductor-based quantum layered structures. Each detector stack absorbs photons within the specified wavelength band while allowing the transmission of photons in other spectral bands, thus efficiently permitting multi-band detection. This produces multiple, spectrally resolved images of the scene that are recorded simultaneously in a single snapshot on the FPA. From the multispectral images and calibration information about the system, computational algorithms are used to evaluate the temperature on the surface of a target.  相似文献   