首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Solid sorbents coated with the fluorescent reagent 5-dimethylaminonaphthalene-1-sulfohydrazide (dansylhydrazine, DNSH) have been used for derivatization and quantitative determination of airborne carbonyl compounds, for example in investigations on atmospheric pollution. The evaluation of this derivatization reaction presented here revealed that, for several reasons, it may not be recommended when sampling is performed with impingers containing liquid reagent solutions. Derivative yields came out to be strongly influenced by water and phosphoric acid which are essential for sufficient derivatization rates, but also responsible for the degradation of derivatives. Even at water and acid concentrations considered as an optimal compromise between accelerating and degrading effects, the analytical reliability of the method can only be guaranteed under controlled laboratory conditions. The reduced or lacking reactivity of DNSH towards aromatic aldehydes or aliphatic and aromatic ketones is an additional finding discarding the DNSH method for routine air monitoring at least when impingers are used for sampling.  相似文献   

2.
The first selective HPLC methods for the determination of peroxyacetic acid (PAA) in gas phase samples have been developed. PAA reacts with 2-([3-{2-[4-amino-2-(methylsulfanyl)phenyl]- 1-diazenyl}phenyl]sulfonyl)-1-ethanol (ADS) to form the corresponding sulfoxide. Sampling may be performed in impingers using aqueous solutions of the reagent or by test tubes with the reagent coated on a solid sorbent. Sulfide and sulfoxide are separated by means of HPLC and detected at a wavelength of 410 nm. The method is highly selective for PAA in the presence of hydrogen peroxide when sampling in impingers. A 10,000-fold excess of hydrogen peroxide leads to the same peak area compared to PAA. Limit of detection is 10(-8) mol PAA, thus corresponding to PAA concentration of 46 ppb when using a sampling time of 10 min with a flow-rate at 500 ml/min. Another sulfide reagent, methyl-p-tolyl sulfide (MTS) has been used in a similar way with impinger sampling. Major advantages of ADS towards MTS are improved UV-Vis spectroscopic properties and reduced volatility.  相似文献   

3.
 A new derivatization method for aromatic amines is presented based on the bromination of the aromatic ring system in an acetic acid medium to yield bromo derivatives. The derivatization method is very simple to perform and overcomes several problems common in the analysis of polar aromatic amines. The derivatives are easy to extract with pentane and can be separated with gas chromatography. Due to the introduction of the electron withdrawing bromo substituents sensitive detection using an electron capture detector is possible. The method was used to investigate the contents of amino- and aminonitrotoluenes in water samples from the site of a former ammunition plant. Received: 17 May 1996/Revised: 1 August 1996/Accepted: 1 August 1996  相似文献   

4.
Sucralose, a persistent chlorinated substance used as sweetener, can already be found in waste water, and various countries focused on the release of sucralose into the aquatic environment. A quantitative high-performance thin-layer chromatography (HPTLC) method, which is orthogonal to existing methods, was developed to analyze sucralose in water. After sample preparation, separation of up to 17 samples was performed in parallel on a HPTLC plate silica gel 60 F(254) with a mixture of isopropyl acetate, methanol and water (15:3:1, v/v/v) within 15 min. Due to the weak native UV absorption of sucralose (≤200 nm), various post-chromatographic derivatization reactions were compared to selectively detect sucralose in effluent and surface water matrices. Thereby p-aminobenzoic acid reagent was discovered as a new derivatization reagent for sucralose. Compared to the latter and to β-naphthol, derivatization with aniline diphenylamine o-phosphoric acid reagent was slightly preferred and densitometry was performed by absorbance measurement at 400 nm. The limit of quantification (LOQ) of sucralose in drinking and surface water was calculated to be 100 ng/L for a given recovery rate of 80% and the extraction of a 0.5 L water sample. The sucralose content determined in four water samples obtained during an interlaboratory trial in 2008 was in good agreement to the mean laboratory values of that trial. According to the t-test, which compares the results with the target value, the means obtained by HPTLC were not significantly different from the respective means of six laboratories, analyzed by HPLC-MS/MS or HPLC-TOF-MS with the use of mostly isotopically labeled standards. The good accuracy and high sample throughput capacity proved HPTLC as a well suited method regarding quantification of sucralose in various aqueous matrices.  相似文献   

5.
A novel colorimetric assay of propranolol tablets has been developed. The assay is based on chemical derivatization (aromatic ring derivatization technique) using diazotized 4-amino-3,5-dinitrobenzoic acid (ADBA) as the chromogenic derivatizing reagent and resultant formation of azo dyes. Optimization studies established an optimal reaction time of 5 min at 30 degrees C after mixing on a Vortex mixer the drug/reagent mixture for 10 s. A new absorption maximum (lambda(max)) was found at 470 nm, which was selected as the analytical wavelength. The assays were linear over 1-8 microg/mL propranolol, and the reaction occurred by a 1:1 reagent/drug stoichiometric ratio. The developed method has a low limit of detection of 0.76 microg/mL and is reproducible. It has been applied successfully to the assay of propranolol tablets and is of equivalent accuracy (p > 0.05) with the official (British Pharmacopoeia) ultraviolet spectrophotometric method. The new method has the main advantage of using more affordable instrumentation and could be applied to the in-process quality control of propranolol tablets.  相似文献   

6.
In this work, a novel technique of aqueous-phase derivatization followed by headspace solid-phase microextraction and gas chromatography-mass spectrometry was developed for the determination of organic acids in urine. The analytical procedure involves derivatization of organic acids to their ethyl esters with diethyl sulfate, headspace sampling, and GC/MS analysis. The proposed method was applied to the determination of methylmalonic acid and glutaric acid in urine. The experimental parameters and method validation were studied. Optimal conditions were obtained: PDMS fiber, extraction temperature 55 degrees C, extraction time 30 min, and 60 microL of diethyl sulfate as derivatization reagent with 2 mg of the ion pairing agent tetrabutylammonium hydrogensulfate. The method was linear over three orders of magnitude, and detection limits were 21 nM for methylmalonic acid and 34 nM for glutaric acid, respectively. Consequently, in-situ derivatization/HS-SPME/GC/MS is an alternative and powerful method for determination of organic acids as biomarkers in biological fluids.  相似文献   

7.
龚淑果  梁勇  唐丽云  黄平  戴云辉 《色谱》2017,35(7):755-759
建立了丹磺酰肼(DNSH)衍生-高效液相色谱-荧光检测测定包装纸中甲醛和乙醛的分析方法,并与2,4-二硝基苯肼(DNPH)衍生法进行了比较。纸张样品经衍生化试剂振荡萃取30 min,衍生化反应24 h,萃取液经PSA/C18净化管净化处理后,以Diamonsil~ C18(2)色谱柱(150 mm×4.6 mm,5μm)为固定相,用醋酸水溶液(pH2.55)-乙腈为流动相进行梯度洗脱。采用荧光检测器检测,激发波长为330 nm,发射波长为484 nm。结果表明,衍生剂、甲醛-DNSH和乙醛-DNSH在20 min内可完全分离,方法的加标回收率为81.64%~106.78%,相对标准偏差(RSD)为2.02%~5.53%(n=5),甲醛和乙醛的检出限分别为19.2μg/kg和20.7μg/kg,定量限分别为63.9μg/kg和69.1μg/kg。该法操作简单,灵敏度高,比常规方法具有更低的检出限,能很好地应用到实际样品检测中,为低含量醛类化合物的检测提供了一种新思路。  相似文献   

8.
The present and past use of chemical derivatization reactions is overviewed with emphasis on the present role of derivatization in chromatographic and electrophoretic methods with special respect to fluorogenic derivatization to increase the selectivity and sensitivity, chiral derivatization to transform enantiomeric pairs to easily separable diastereomers, and GC/GC-MS derivatization. Non-chromatographic derivatization is also discussed with emphasis on UV-VIS spectrophotometry, fluorimetry, and immunoassay methods. The up-to-dateness of derivatization methods with negative examples mainly from the field of UV-VIS analysis are also discussed. Finally, examples are given on how the experiences obtained in the course of old studies can be used to solve current problems with the aid of chemical derivatization. Received: 19 January 1998 / Revised: 2 March 1998 / Accepted: 6 March 1998  相似文献   

9.
The present and past use of chemical derivatization reactions is overviewed with emphasis on the present role of derivatization in chromatographic and electrophoretic methods with special respect to fluorogenic derivatization to increase the selectivity and sensitivity, chiral derivatization to transform enantiomeric pairs to easily separable diastereomers, and GC/GC-MS derivatization. Non-chromatographic derivatization is also discussed with emphasis on UV-VIS spectrophotometry, fluorimetry, and immunoassay methods. The up-to-dateness of derivatization methods with negative examples mainly from the field of UV-VIS analysis are also discussed. Finally, examples are given on how the experiences obtained in the course of old studies can be used to solve current problems with the aid of chemical derivatization. Received: 19 January 1998 / Revised: 2 March 1998 / Accepted: 6 March 1998  相似文献   

10.
Two methods for the sampling and analysis of tar produced from wood pyrolysis were compared. The first method used a conventional cold-trapping technique in solvent-filled impingers followed by liquid injection. The second one is a new application of multibed solid-phase adsorbent (SPA) tubes followed by thermal desorption (TD). Both methods are based on gas chromatography (GC) coupled with mass spectrometry (MS). Quantification was performed with a well reproducible GC-MS method with three internal deuterated standards. The SPA/TD method offers several advantages. No solvent is required, the detection levels are improved, and gas chromatography separation is easier. Moreover, sampling time is reduced from about 1h (for the conventional cold-trapping technique in impingers) to a few seconds. No discrimination was observed between the two sampling methods for the 10 quantified compounds (aromatic compounds from benzene to phenanthrene and phenols) except for benzene.  相似文献   

11.
5-Amino-4-sulfanylphthalhydrazide (ASPH) was synthesized as a chemiluminescence derivatization reagent for aromatic aldehydes in liquid chromatography (LC). Benzaldehyde, 4-tolualdehyde, 4-chlorobenzaldehyde, 4-formylbenzoic acid, 4-hydroxybenzaldehyde and vanillin were used as model compounds to optimize the derivatization conditions. This reagent, ASPH, reacts selectively with aromatic aldehydes in the presence of sodium sulfite and disodium hydrogenphoshite in acidic medium at 100 degrees C to give the corresponding highly chemiluminescent 2-arylbenzothiazole derivatives. The resulting derivatives generated intense chemiluminescence by reaction with hydrogen peroxide and potassium hexacyanoferrate(III) in alkaline solution. The ASPH derivatives of aromatic aldehydes were separated by reversed-phase liquid chromatography with isocratic elution, and detected chemiluminometrically after mixing with oxidizing agents. The detection limits (signal-to-noise ratio = 3) for aromatic aldehydes are in the range 0.2-4.0 fmol for a 20-microl injection volume. Currently, the method is not effective for aliphatic aldehydes because of interfering LC peaks.  相似文献   

12.
Conditions have been established for the detection by chemical ionization mass spectrometry (CIMS) of compounds related to L -dopa (3-hydroxy-L -tyrosine) and L -tryptophan without derivatization. The least fragmentation of the parent ion occurs in positive ion CIMS when methylamine is used as reagent gas. The compounds can also be detected by negative ion CIMS using carbon tetrachloride as reagent gas. While the total ion current in the latter technique is lower than that obtained with positive ion CIMS, the background noise in the mass spectra of samples obtained from natural sources is greatly reduced. CIMS has been used to show the presence of aromatic amino acids in acid extracts of samples of two different classes of tumour without sample derivatization.  相似文献   

13.
A newly developed method for determining three phenoxy acids and one carbamate herbicide in water and soil samples using gas chromatography with mass spectrometric detection is developed. Phenoxy acids are derivatized through a condensation reaction with a suitable aromatic amine. 1,1-Carbonyldiimidazole is used as a condensation reagent. Derivatization conditions are optimized with respect to the amount of analyte, amine, solvent, and derivatization reagent. The optimum derivatization yield is accomplished in acetonitrile. 4-Methoxy aniline is used as a derivatizing agent. Obtained derivatives are stable indefinitely. Enhancement in sensitivity is achieved by using the single-ion monitoring mass spectrometric mode. The effectiveness of the developed method is tested by determining investigated compounds in water and soil samples. Analytes are concentrated from water samples using liquid-phase extraction and solid-phase extraction. Soil samples are extracted using methanol. Detection limits of 1.00, 50.00, 100.00, and 1.00 ng/mL are obtained for 2-(1-methylethoxy)phenyl methylcarbamate (Baygon), 2-(3-chlorophenoxy)-propionic acid (Cloprop), 2,4,5-trichlorophenoxyacetic acid, and 4-(2,4-dichlorophenoxy)butyric acid, respectively. LPE for spiked water samples yields recoveries in the range of 60.6-95.7%, with relative standard deviation (RSD) values of 1.07-7.85% using single component calibration curves. Recoveries of 44.8-275.5%, with RSD values ranging from 1.43% to 8.61% were obtained using a mixed component calibration curves. SPE from water samples and soil samples showed low recoveries. The reason is attributed to the weak sorption capabilities of soil and Al(2)O(3).  相似文献   

14.
An analytical method for the determination of aromatic amines in water is introduced that uses iodination with a Sandmeyer-like reaction to replace the amino group by iodine in aqueous solution. The non-polar derivatives are extracted with pentane or toluene, separated with gas chromatography and sensitively detected with an ECD. Thirteen major metabolites of nitroaromatic explosives were investigated. The method was used to analyze these metabolites in water samples from the site of a former ammunition plant. The results are compared with the derivatization of aromatic amines via bromination of the aromatic ring. Received: 23 December 1996 / Revised: 31 January 1997 / Accepted: 8 February 1997  相似文献   

15.
A trapping reagent for formaldehyde, based on the pararosaniline reaction, was evaluated as a method of determination of formaldehyde in the aqueous or vapour phase. Collection of formaldehyde vapour relied upon passive diffusion of formaldehyde into the trapping media and quantitative results were obtained without the need for liquid impingers, bubblers or active sampling pumps. Moreover, a novel, hand-held absorption spectrophotometric measurement device was designed to provide on-site, quantitative measurements. It is proposed that the full measurement system devised would be ideally suited to specific sampling applications such as those found in museum enclosures.  相似文献   

16.
D Zhao  M Lu  Z Cai 《Electrophoresis》2012,33(15):2424-2432
An efficient and sensitive method for the separation and determination of three essential amino acids and three B vitamins by CE-LIF with a simultaneous derivatization procedure was developed. The conditions for derivatization and separation of these micronutrients were investigated. FITC was used as the reagent for fluorescence tagging of arginine (Arg), valine (Val), tryptophan (Trp), folic acid (FA), and niacinamide (NA). Riboflavin (RF) was detected without derivatization. Derivatization of analytes dissolved in borate solution was performed by successive introduction of fluorescence reagent and analytes followed by water bathing at 43°C. The molar ratio of sample/reagent (S/R), derivatization temperature, and incubation time significantly influenced the efficiency of derivatization. To maximize the fluorescence yield, a high S/R (≥20) was required. The nonderivatized RF and five derivatized analytes were separated in the optimized CE-LIF system with the application of 22 kV voltage and 25 mM borate buffer at pH 9.85. Validation of the method showed good linearity for the corrected peak areas versus standard concentrations for the six analytes. The RSDs (n = 3) of the migration time and the peak area obtained for the analytes ranged from 0.4 to 1.1% and from 1.9 to 4.4%, respectively. The developed method, with the lowest LOD of 0.5 nM, was successfully applied for the efficient derivatization and determination of B vitamins in four health drink samples.  相似文献   

17.
In this study novel immunoconjugates were designed, synthesized and then used to develop a rapid, specific and sensitive indirect ELISA method to directly detect residues of 3,5-dinitrosalicyclic acid hydrazide (DNSH), a toxic metabolite of nifursol present in chicken tissues. The hapten DNSHA was first designed and used to covalently couple to BSA to form an immunogen which was immunized to rabbits to produce a polyclonal antibody against DNSH. Furthermore, a novel 3,5-dinitrosalicylic acidovalbumin (DNSA-OVA) immunoconjugate structurally different from DNSHA-OVA was designed and used as a "substructural coating antigen" to improve the sensitivity of an indirect ELISA analysis for a direct DNSH detection. Based on the "substructural coating antigen" concept, an optimized indirect ELISA method was established that exhibited good specificity and high sensitivity for detecting DNSH, with a cross-reactivity of less than 0.1% (excluding the parent compound nifursol), IC(50) of 0.217 nmol/mL and detection limit of 0.018 nmol/mL. Finally, a simple and efficient analysis of DNSH samples in chicken tissues showed that the average recovery rate of the indirect ELISA analysis was 82.3%, with the average coefficient of variation 15.9%. Thus, the developed indirect ELISA method exhibited the potential for a rapid detection of DNSH residues in tissue.  相似文献   

18.
2-(2-phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA) and 2-(9-acridone)-acetic acid (AAA), two novel precolumn fluorescent derivatization reagents, have been developed and compared for analysis of primary aromatic amines by high performance liquid chromatographic fluorescence detection coupled with online mass spectrometric identification. PPIA and AAA react rapidly and smoothly with the aromatic amines on the basis of a condensation reaction using 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC) as dehydrating catalyst to form stable derivatives with emission wavelengths at 380 and 440 nm, respectively. Taking six primary aromatic amines (aniline, 2-methylaniline, 2-methoxyaniline, 4-methylaniline, 4-chloroaniline, and 4-bromoaniline) as testing compounds, derivatization conditions such as coupling reagent, basic catalyst, reaction temperature and time, reaction solvent, and fluorescent labeling reagent concentration have also been investigated. With the better PPIA method, chromatographic separation of derivatized aromatic amines exhibited a good baseline resolution on an RP column. At the same time, by online mass spectrometric identification with atmospheric pressure chemical ionization (APCI) source in positive ion mode, the PPIA-labeled derivatives were characterized by easy-to-interpret mass spectra due to the prominent protonated molecular ion m/z [M + H](+) and specific fragment ions (MS/MS) m/z 335 and 295. The linear range is 24.41 fmol-200.0 pmol with correlation coefficients in the range of 0.9996-0.9999, and detection limits of PPIA-labeled aromatic amines are 0.12-0.21 nmol/L (S/N = 3). Method repeatability, precision, and recovery were evaluated and the results were excellent for the efficient HPLC analysis. The most important argument, however, was the high sensitivity and ease-of-handling of the PPIA method. Preliminary experiments with wastewater samples collected from the waterspout of a paper mill and its nearby soil where pollution with aromatic amines may be expected show that the method is highly validated with little interference in the chromatogram.  相似文献   

19.
Summary The reagentp-nitrobenzyloxycarbonyl chloride (PNZ-CI) was used for pre-column derivatization of biogenic amines (BAs) at ambient temperature followed by reversed-phase, liquid-chromatographic separation of the derivatives. Optimized derivatization of samples was achieved within 10 min in borate buffer by adding PNZ-Cl in acetonitrile (MeCN). Excess reagent was scavenged by subsequent addition of glycine in water. For LC a Superspher? RP-18e column and gradient elution using a ternary gradient system containing sodium acetabe buffer (pH 6.1), sodium acetate buffer (pH 4.3) and MeCN, were used. The PNZ-derivatives were quantified by their UV-absorption at 265 nm. Detection limits of BAs were approximately 62–1000 μg L−1 (injected amounts: 53–850 pg) at a signal-to-noise ratio of 3:1. The coefficients of determination were 0.9906–0.9992. Diaminohexane was used as internal standard. Recoveries of BAs ranged from 78–93% depending on the food matrix. This method was applied to the quantitative determination of 2-phenylethylamine, tryptamine, serotonin, putrescine, histamine, cadaverine, tyramine, spermidine, and spermine, in beer, wine, vinegars, and lactic fermented cabbage juice. Parts of the results were presented at the 35th Congress of the “Deutsche Gesellschaft für Ern?hrung”, Kiel, 19th–20th March 1998, and the “Regionaltagung der Lebensmittelchemiker”, Giessen, 9th–10th March 1998  相似文献   

20.
We developed a rapid and sensitive method using in-capillary derivatization and laser-induced fluorescence (LIF) detection for the fully automated analysis of organophosphorus pesticides (OPPs), including glufosinate, aminomethylphosphonic acid (AMPA) and glyphosate by micellar electrokinetic chromatography (MEKC). The potential of 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) as in-capillary derivatization reagent is described for the first time. The unique feature of this MEKC method is the capillary being used as a small reaction chamber. In in-capillary derivatization, the sample and reagent solutions were injected directly into the capillary by tandem mode, followed by an electrokinetic step to enhance the mixing efficiency of analytes and reagent plugs in accordance with their different electrophoretic mobilities. Standing a specified time for reaction, the derivatives were then immediately separated and determined. Careful optimization of the derivatization and separation conditions allowed the determination of glufosinate, AMPA and glyphosate with detection limits of 2.8, 3.6 and 32.2 ng/mL, respectively. These detection limits were comparable to those of 1.4, 1.9 and 23.8 ng/mL obtained from conventional pre-capillary derivatization. Furthermore, repeatability better than 0.40% for migration time and 3.4% for peak area, as well as shorter migration time, was obtained. The method was successfully applied to the analysis of spiked river water sample with satisfactory results.  相似文献   