首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This work reports a novel fabrication technique for development of channels on paper‐based microfluidic devices using the syringe module of a 3D printing syringe–based system. In this study, printing using polycaprolactone (PCL)‐based ink (Mw 70 000‐90 000) was employed for the generation of functional hydrophobic barriers on Whatman qualitative filter paper grade 1 (approximate thickness of 180 μm and pore diameter of 11 μm), which would effectively channelize fluid flow to multiple assay zones dedicated for different analyte detection on a microfluidic paper‐based analytical device (μPAD). The standardization studies reveal that a functional hydrophilic channel for sample conduction fabricated using the reported technique can be as narrow as 460.7 ± 20 μm and a functional hydrophobic barrier can be of any width with a lower limit of about 982.2 ± 142.75 μm when a minimum number of two layers of the ink is extruded onto paper. A comparison with the hydrodynamic model established for writing with ink is used to explain the width of the line printed by this system. A fluid flow analysis through a single channel system was also carried out to establish its conformity with the Washburn model, which governs the fluid flow in two‐dimensional μPAD. The presented fabrication technique proves to be a robust strategy that effectively taps the advantages of this 3D printing technique in the production of μPADs with enhanced speed and reproducibility.  相似文献   

2.
This paper presents a simple and low-cost method for patterning poly(dimethylsiloxane) (PDMS) barriers in porous support such as paper for the construction of flexible microfluidic paper-based analytical devices (μPADs). The fabrication method consisted of contact-printing a solution of PDMS and hexane (10:1.5 w/w) onto chromatographic paper using custom-designed rubber stamps containing the patterns of μPADs. After penetrating the paper (∼30 s), the PDMS is cured to form hydrophobic barriers. Under optimized conditions, hydrophobic barriers and hydrophilic channels with dimensions down to 949 ± 88 μm and 771 ± 90 μm (n = 5), respectively, were obtained. This resolution is well-suitable for most applications in analytical chemistry. Chemical compatibility studies revealed that the PDMS barriers were able to contain some organic solvents, including acetonitrile and methanol, and aqueous solutions of some surfactants. This find is particularly interesting given that acetonitrile and methanol are the most used solvents in chromatographic separations, non-aqueous capillary electrophoresis and electroanalysis, as well as aqueous solutions of surfactants are suitable mediums for cell lyses assays. The utility of the technique was evaluated in the fabrication of paper-based electrochemical devices (PEDs) with pencil-drawn electrodes for experiments in static cyclic voltammetry and flow injection analysis (FIA) with amperometric detection, in both aqueous and organic mediums.  相似文献   

3.
Paper-based microfluidic devices are an alternative technology for fabricating simple, low-cost, portable and disposable platforms for clinical diagnosis. Hereby, a novel wax dipping method for fabricating paper-based microfluidic devices (μPADs) is reported. The iron mould for wax dipping was created by a laser cutting technique. The designed pattern was transferred onto paper by dipping an assembly mould into melted wax. The optimal melting temperature and dipping time were investigated. The optimal melting temperature was in the range of 120-130 °C, and the optimal dipping time was 1 s. The whole fabrication process could be finished within 1 min without the use of complicated instruments or organic solvents. The smallest hydrophilic channel that could be created by the wax dipping method was 639 ± 7 μm in size. The reproducibility of the μPAD fabrication for hydrophilic channel width of the test zone and sample zone was 1.48% and 6.30%, respectively. To verify the performance of the μPAD, multiple colorimetric assays for simultaneous detection of glucose and protein in real samples were performed. An enzymatic assay and the bromocresol green (BCG) method were conducted on the paper device to determine the presence of glucose and protein in a test solution. The results of the assays were not significantly different from those of the conventional methods (p > 0.05, pair t-test and one-way ANOVA method). The wax dipping provides a new alternative method for fabricating lab-on-paper devices for multiple clinical diagnostics and will be very beneficial for developing countries.  相似文献   

4.
A novel method for the fabrication of paper-based microfluidic diagnostic devices is reported; it consists of selectively hydrophobizing paper using cellulose reactive hydrophobization agents. The hydrophilic–hydrophobic contrast of patterns so created has excellent ability to control capillary penetration of aqueous liquids in paper channels. Incorporating this idea with digital ink jet printing techniques, a new fabrication method of paper-based microfluidic devices is established. Ink jet printing can deliver biomolecules and indicator reagents with precision into the microfluidic patterns to form bio-chemical sensing zones within the device. This method thus allows the complete sensor, i.e. channel patterns and the detecting chemistries, to be fabricated only by two printing steps. This fabrication method can be scaled up and adapted to use high speed, high volume and low cost commercial printing technology. Sensors can be fabricated for specific tests, or they can be made as general devices to perform on-demand quantitative analytical tasks by incorporating the required detection chemistries for the required tasks.  相似文献   

5.
A low cost, disposable and easy to use microfluidic paper-based analytical device (μPAD) was developed for simple and non-invasive determination of total aldehydes in saliva with a potential to be used in epidemiological studies to assess oral cancer risk. The μPAD is based on the colour reaction between aldehydes (e.g. acetaldehyde, formaldehyde), 3-methyl-2-benzothiazolinone hydrazone (MBTH) and iron(III) to form an intense blue coloured formazan dye. The newly developed μPAD has a 3D design with two overlapping paper layers. The first layer comprises 15 circular detection zones (8 mm in diameter), each impregnated with 8 μL of MBTH, while the second layer contains 15 reagent zones (4 mm in diameter). Two μL of iron(III) chloride are added to each one of the second layer zones after the addition of sample to the detection zones in the first layer. All hydrophilic zones of the μPAD are defined by wax printing using a commercial wax printer.  相似文献   

6.
This paper describes the fabrication of microfluidic cloth-based analytical devices (μCADs) using a simple wax patterning method on cotton cloth for performing colorimetric bioassays. Commercial cotton cloth fabric is proposed as a new inexpensive, lightweight, and flexible platform for fabricating two- (2D) and three-dimensional (3D) microfluidic systems. We demonstrated that the wicking property of the cotton microfluidic channel can be improved by scouring in soda ash (Na(2)CO(3)) solution which will remove the natural surface wax and expose the underlying texture of the cellulose fiber. After this treatment, we fabricated narrow hydrophilic channels with hydrophobic barriers made from patterned wax to define the 2D microfluidic devices. The designed pattern is carved on wax-impregnated paper, and subsequently transferred to attached cotton cloth by heat treatment. To further obtain 3D microfluidic devices having multiple layers of pattern, a single layer of wax patterned cloth can be folded along a predefined folding line and subsequently pressed using mechanical force. All the fabrication steps are simple and low cost since no special equipment is required. Diagnostic application of cloth-based devices is shown by the development of simple devices that wick and distribute microvolumes of simulated body fluids along the hydrophilic channels into reaction zones to react with analytical reagents. Colorimetric detection of bovine serum albumin (BSA) in artificial urine is carried out by direct visual observation of bromophenol blue (BPB) colour change in the reaction zones. Finally, we show the flexibility of the novel microfluidic platform by conducting a similar reaction in a bent pinned μCAD.  相似文献   

7.
Watanabe M 《The Analyst》2011,136(7):1420-1424
A microfluidic device for liquid-liquid extraction was quickly produced using an office inkjet printer. An advantage of this method is that normal end users, who are not familiar with microfabrication, can produce their original microfluidic devices by themselves. In this method, the printer draws a line on a hydrophobic and oil repellent surface using hydrophilic ink. This line directs a fluid, such as water or xylene, to form a microchannel along the printed line. Using such channels, liquid-liquid extraction was successfully performed under concurrent and countercurrent flow conditions.  相似文献   

8.
In this work, we first introduce the fabrication of microfluidic cloth-based analytical devices (μCADs) using a wax screen-printing approach that is suitable for simple, inexpensive, rapid, low-energy-consumption and high-throughput preparation of cloth-based analytical devices. We have carried out a detailed study on the wax screen-printing of μCADs and have obtained some interesting results. Firstly, an analytical model is established for the spreading of molten wax in cloth. Secondly, a new wax screen-printing process has been proposed for fabricating μCADs, where the melting of wax into the cloth is much faster (∼5 s) and the heating temperature is much lower (75 °C). Thirdly, the experimental results show that the patterning effects of the proposed wax screen-printing method depend to a certain extent on types of screens, wax melting temperatures and melting time. Under optimized conditions, the minimum printing width of hydrophobic wax barrier and hydrophilic channel is 100 μm and 1.9 mm, respectively. Importantly, the developed analytical model is also well validated by these experiments. Fourthly, the μCADs fabricated by the presented wax screen-printing method are used to perform a proof-of-concept assay of glucose or protein in artificial urine with rapid high-throughput detection taking place on a 48-chamber cloth-based device and being performed by a visual readout. Overall, the developed cloth-based wax screen-printing and arrayed μCADs should provide a new research direction in the development of advanced sensor arrays for detection of a series of analytes relevant to many diverse applications.  相似文献   

9.
This paper describes simple and rapid methods for the fabrication of glass and polymeric chips for routine analytical applications. The methods are easily interfaced to the general laboratory environment and do not require special clean room facilities or expensive instruments. Glass microchips were fabricated by etching with HF solution. Microfluidic channels were designed with CAD program and transferred onto a sheet of commercial polymeric self-adhesive (PSA) film by a cutter plotter. The PSA film was used as a mask for etching process. The etching rate was about 7 μm min−1. A cover glass plate was sealed on the top of etched substrate by using polycellulose (cellophane). Polymeric microchips were fabricated by sawing with a jigsaw. Commercial polycarbonate (PC) was used as a substrate and two iron sheets were used as leader masks. While this restricts us to the fabrication of straight channels, it is however, much faster and less complicated than the other methods. The chip comprised three polymeric plates and the channels were created in the middle plate. Thermal bonding was used to bond three layers of the microfluidic chip. With this method, we could achieve simple channels with the width of about 200 μm. The channel depth depends on the polymeric plate thickness. Fabricated channels were accurate without any sinuosity or sideshow.  相似文献   

10.
Recent research on microfluidic paper-based analytical devices (μPADs) has shown that paper has great potential for the fabrication of low-cost diagnostic devices for healthcare and environmental monitoring applications. Herein, electrochemiluminescence (ECL) was introduced for the first time into μPADs that were based on screen-printed paper-electrodes. To further perform high-specificity, high-performance, and high-sensitivity ECL on μPADs for point-of-care testing (POCT), ECL immunoassay capabilities were introduced into a wax-patterned 3D paper-based ECL device, which was characterized by SEM, contact-angle measurement, and electrochemical impedance spectroscopy. With the aid of a home-made device-holder, the ECL reaction was triggered at room temperature. By using a typical tris(bipyridine)ruthenium-tri-n-propylamine ECL system, this paper-based ECL 3D immunodevice was applied to the diagnosis of carcinoembryonic antigens in real clinical serum samples. This contribution further expands the number of sensitive and specific detection modes of μPADs.  相似文献   

11.
纸基过氯乙烯树脂微流控亚硝酸根离子检测片的研制   总被引:1,自引:0,他引:1  
赵联朝  闫宏涛 《化学学报》2012,70(9):1104-1108
基于滤纸上过氯乙烯树脂栏选择性通过亚硝酸根离子, 结合微流控分析装置设计, 研制成纸基过氯乙烯树脂微流控亚硝酸根离子检测芯片. 采用该微流控亚硝酸根离子检测芯片测定了亚硝酸盐样品, 线性范围和检测限分别为70~1500 μmol/L 和48 μmol/L. 该微流控亚硝酸根离子检测芯片已成功应用于水样和食品中亚硝酸盐测定, 结果满意.  相似文献   

12.
A method was developed for the fabrication of microfluidic paper-based analytical devices (μPAD). This method was based on the silanisation of cellulose in filter paper using alkyltrimethoxysilane coupled with UV radiation. The filter paper sheet was hydrophobised by immersion in an octadecyltrimethoxysilane/heptane (OTMS/heptane) solution (0.25 vol. %) containing 5 vol. % of ethyl acetate (EtOAc). The hydrophobic-hydrophilic contrast was generated on the filter paper after the hydrophobised paper sheet was exposed to UV light with a metal mask creating the desired pattern on the sheet. The exposed area was oxidised to create a hydrophilic area, while the hydrophobic area was protected by the metal mask. The optimal conditions for the fabrication of μPAD were studied; these included ethyl acetate concentration (CEtOAc), immersion time, octadecyltrimethoxysilane concentration (COTMS) and exposure time. This method is cost-effective and simple. In addition, different functional groups could be further grafted for various assay purposes. To demonstrate the feasibility of the μPAD in analytical applications, a flower-shaped μPAD with eight channels and eight detection units was fabricated and used to determine the nitrite content in pickled vegetables. The nitrite content (124 µg g?1) in the sample determined by this method compared favourably with that measured using a standard method (137 µg g?1).  相似文献   

13.
Microfabricated microfluidic devices provide useful platforms for sensing and conducting immunoassays for high throughput screening and drug discovery. In this paper, fluorescence polarization (FP) has been used as a technique for probing binding events within 500 μm and smaller microfluidic channels fabricated in polydimethylsiloxane. The binding of concanavalin A to a lectin-dextran and a glycoprotein-acetylcholinesterase has been used to demonstrate the homogeneous, ratioing format of fluorescence polarization for the quick and accurate determination of extremely low concentrations. Concentrations of concanavalin A in the 0.2-1.0 nmole range were detected within 500 μm channels. Polarization has also been used to sense for a polyaromatic hydrocarbon (PAH) within a microfluidic channel using binding to a TRITC-labeled antibody. Specifically, concentrations of pyrene in a 10-40 nmole range were sensed in 500 μm microfluidic channels. We have also demonstrated a simple pH sensor based on the change in anisotropy of a pH sensitive fluorophore-SNAFL. The ease of fabrication and measurement using such polarization-based devices make them extremely suitable for micro-sized sensors, assays and total analysis systems.  相似文献   

14.
Li CW  Cheung CN  Yang J  Tzang CH  Yang M 《The Analyst》2003,128(9):1137-1142
We have developed a method for fabricating microfluidic devices with multi-height structures using single step photolithography. The whole fabrication process is executed by conventional printed circuit board (PCB) technology without the need of having access to clean room facilities. Specifically designed "windows" and "rims" architectures were printed on films that were used as photomasks. Different levels of protruding features on the PCB master were produced by exposing a photomask followed by chemical wet etching. Poly(dimethylsiloxane) (PDMS) was then moulded against the positive relief master to generate microfluidic structures. In this report, we described the fabrication of a microfluidic device featured with a multi-height "sandbag" structure for particle entrapment and peripheral microchannels. Controlled immobilization of biological cells and immunocytochemcial staining assays were performed to demonstrate the applicability of the microfluidic device for cellular analysis. The integrity of the microdevice remained stable under applied pressure, indicating the robustness of the elastic PDMS structures for analytical operation. The simple microfabrication process requires only low-cost materials and minimal specialized equipment and can reproducibly produce mask lines of about 20 microm in width, which is sufficient for most microfluidic applications.  相似文献   

15.
近年来,微流控纸芯片由于低成本、便携化、检测快等优点,在需要快速检测的环境分析领域中展现出了巨大的应用前景。该综述从微流控纸芯片在环境分析中的应用角度,总结归纳了微流控纸芯片在环境分析中的最新研究进展,并展望了其在未来的发展趋势与挑战。论文内容引用150余篇源于科学引文索引(SCI)与中文核心期刊中的相关论文。该综述包括微流控纸芯片在环境检测中的优势与制造方法介绍;电化学法、荧光法、比色法、表面增强拉曼法、集成传感法等基于纸芯片的先进分析方法介绍;根据环境分析目标物种类,如重金属离子、营养盐、农药、微生物、抗生素以及其他污染物等,对纸芯片的最新应用现状进行了举例评述;基于微流控纸芯片的环境分析研究的未来发展趋势和前景展望。通过综述近期相关研究,表明微流控纸芯片从提出至今虽然只有十几年的发展历程,但其在环境分析研究中的发展却十分迅速。微流控纸芯片可以根据不同的环境条件和检测要求灵活选择制作与分析方法,实现最佳的检测效果。但是微流控纸芯片也面临一些挑战,如纸张机械强度不足、流体控制程度不佳等问题。这些问题指出了微流控纸芯片在环境检测领域的发展趋势,相信随着不断深入的研究,纸芯片将会在未来的环境分析中发挥更大作用。  相似文献   

16.
Rapid, precise, and reproducible deposition of a broad variety of functional materials, including analytical assay reagents and biomolecules, has made inkjet printing an effective tool for the fabrication of microanalytical devices. A ubiquitous office device as simple as a standard desktop printer with its multiple ink cartridges can be used for this purpose. This Review discusses the combination of inkjet printing technology with paper as a printing substrate for the fabrication of microfluidic paper‐based analytical devices (μPADs), which have developed into a fast‐growing new field in analytical chemistry. After introducing the fundamentals of μPADs and inkjet printing, it touches on topics such as the microfluidic patterning of paper, tailored arrangement of materials, and functionalities achievable exclusively by the inkjet deposition of analytical assay components, before concluding with an outlook on future perspectives.  相似文献   

17.
Many diagnostic tests in a conventional clinical laboratory are performed on blood plasma because changes in its composition often reflect the current status of pathological processes throughout the body. Recently, a significant research effort has been invested into the development of microfluidic paper-based analytical devices (μPADs) implementing these conventional laboratory tests for point-of-care diagnostics in resource-limited settings. This paper describes the use of red blood cell (RBC) agglutination for separating plasma from finger-prick volumes of whole blood directly in paper, and demonstrates the utility of this approach by integrating plasma separation and a colorimetric assay in a single μPAD. The μPAD was fabricated by printing its pattern onto chromatography paper with a solid ink (wax) printer and melting the ink to create hydrophobic barriers spanning through the entire thickness of the paper substrate. The μPAD was functionalized by spotting agglutinating antibodies onto the plasma separation zone in the center and the reagents of the colorimetric assay onto the test readout zones on the periphery of the device. To operate the μPAD, a drop of whole blood was placed directly onto the plasma separation zone of the device. RBCs in the whole blood sample agglutinated and remained in the central zone, while separated plasma wicked through the paper substrate into the test readout zones where analyte in plasma reacted with the reagents of the colorimetric assay to produce a visible color change. The color change was digitized with a portable scanner and converted to concentration values using a calibration curve. The purity and yield of separated plasma was sufficient for successful operation of the μPAD. This approach to plasma separation based on RBC agglutination will be particularly useful for designing fully integrated μPADs operating directly on small samples of whole blood.  相似文献   

18.
Applications of poly(dimethylsiloxane) (PDMS)-based microfluidic systems are more popular nowadays. Previous fabrication methods of the masters for PDMS microchannels require complicated steps and/or special device. In this paper, we demonstrated that the toner printed on the transparency film with the office laser printer (1200 dpi) can be used as the positive relief of the masters. The transparency film was printed in two steps in order to obtain the same printing quality for the crossed lines. With the laser-printed master, the depth of the fabricated PDMS microchannels was ca. 10 microm and the smallest width was ca. 60 microm. Surface characteristics of the PDMS/PDMS microchannels were performed with SEM. Their electrokinetic properties were investigated by the aids of the measurement of electroosmotic flow (EOF) and the Ohm's curve. Using the PDMS/PDMS microchip CE systems, electroactive biological molecules and non-electroactive inorganic ions were well separated, respectively. This simple approach could make it easy to carry out the studies of PDMS microfluidic systems in more general labs without special devices.  相似文献   

19.
The shortage of ready to use small sized liquid propulsion and switching devices for microfluidic cells (μ-cell) is a bottleneck in the dissemination of micro-flow analysis (μ-FA), now that microfluidic electrochemical cells can be designed and assembled in any laboratory by thermal transfer of laser printed masks and CD-Rs. Microprocessor-controlled electronic pipettors, commercially available with minimum capacity of 10 μL, represent a compromise solution between oversized peristaltic pumps and tiny “on a chip” micropumps and valves. The versatility of the electronic pipette coupled with the μ-cell (13-μm deep longitudinal channel) was demonstrated in three operation modes: SIA like, FIA like and direct injection analysis (DIA). Injections of 100 nL K4Fe(CN)6 (0.1 mol L−1 KCl) define a linear analytical curve (r = 0.999) in the range of 5 × 10−7 to 1.0 × 10−3 mol L−1 for flow amperometry at a gold electrode potentiostated at 0.4 V versus Ag/AgCl. Methods for the amperometric μ-flow determination of promethazine (FIA like), dipyrone (SIA like) and chlorpromazine (DIA) in pharmaceutical formulations were developed and applied to real samples. Excellent linearity of analytical curves and high repeatability (R.S.D. < 3.0%) at the low picomole range was obtained and all results for real samples were in agreement with reference methods. The results reflect the stability and the reliability of the setups envisioned for the electronic pipette coupled with amperometric μ-cell and the validity of the μ-FA methods.  相似文献   

20.
Occupational exposure to Cr is concerning because of its myriad of health effects. Assessing chromium exposure is also cost and resource intensive because the analysis typically uses sophisticated instrumental techniques like inductively coupled plasma-mass spectrometry (ICP-MS). Here, we report a novel, simple, inexpensive microfluidic paper-based analytical device (μPAD) for measuring total Cr in airborne particulate matter. In the μPAD, tetravalent cerium (Ce(IV)) was used in a pretreatment zone to oxidize all soluble Cr to Cr(VI). After elution to the detection zone, Cr(VI) reacts with 1,5-diphenylcarbazide (1,5-DPC) forming 1,5-diphenylcarbazone (DPCO) and Cr(III). The resulting Cr(III) forms a distinct purple colored complex with the DPCO. As proof-of-principle, particulate matter (PM) collected on a sample filter was analyzed with the μPAD to quantify the mass of total Cr. A log-linear working range (0.23–3.75 μg; r2 = 0.998) between Cr and color intensity was obtained with a detection limit of 0.12 μg. For validation, a certified reference containing multiple competing metals was analyzed. Quantitative agreement was obtained between known Cr levels in the sample and the Cr measured using the μPAD.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号