首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   38篇
  免费   1篇
  国内免费   1篇
化学   28篇
数学   1篇
物理学   11篇
  2023年   1篇
  2022年   1篇
  2019年   2篇
  2018年   1篇
  2016年   1篇
  2015年   1篇
  2014年   2篇
  2012年   2篇
  2011年   4篇
  2010年   4篇
  2009年   2篇
  2008年   1篇
  2007年   1篇
  2006年   2篇
  2005年   2篇
  2002年   1篇
  2001年   1篇
  2000年   3篇
  1999年   2篇
  1998年   1篇
  1996年   3篇
  1995年   1篇
  1994年   1篇
排序方式: 共有40条查询结果,搜索用时 171 毫秒
1.
This research aims to synthesize a specific and efficient sorbent to use in the extraction of apixaban from human plasma samples and its determination by high-performance liquid chromatography-tandem mass spectrometry. High specific surface area of metal-organic framework, magnetic property of iron oxide nanoparticles, selectively of molecular imprinted polymer toward the analyte, and the combination of dispersive solid-phase extraction method with a sensitive analysis system provided an efficient analytical method. In this study, first, a molecularly imprinted polymer combined with magnetic metal organic framework nanocomposite was prepared and then characterized using different techniques. Then the sorbent particles were used for selective extraction of the analyte from plasma samples. The efficiency of the method was improved by optimizing effective parameters. According to the validation results, wide linear range (1.02–200 ng mL−1), acceptable coefficient of determination (0.9938), low limit of detection (0.32 ng mL−1) and limit of quantification (1.02 ng mL−1), high extraction recovery (78%), and good precision (relative standard deviations ≤ 2.9% for intra- (n = 6) and interday (n = 6) precisions) were obtainable using the proposed method. These outcomes showed the high potential of the proposed method for screening apixaban in the human plasma samples.  相似文献   
2.
A vortex-assisted dispersive micro-solid-phase extraction procedure using a new and green sorbent was developed as a simple, fast, and efficient sample preparation method for the extracting five pesticides in several fruit juice samples. In this study, for the first time, riboflavin was used as an efficient sorbent. A few milligrams of riboflavin was directly added into the aqueous solution containing the analytes to adsorb them. After adsorption the analytes, they were desorbed and more concentrated by a dispersive liquid–liquid microextraction procedure. The influence of several effective parameters such as amount of riboflavin, pH, vortex time, eluent nature and volume, and extraction solvent type and volume on the extraction efficiency was investigated. In optimal conditions, linear ranges of the calibration curves were broad. The limits of detection and quantification were attained in the ranges of 0.56–1.5  and 1.9–0.52 ng mL−1, respectively. The proposed method demonstrated to be suitable for concurrent extraction of the studied pesticides in various fruit juice samples with high enrichment factors (320–360) and precision (relative standard deviation ≤7.8% for intra- [n = 6] and interday [n = 4] precisions at a concentration of 25 ng mL−1 of each pesticide).  相似文献   
3.

An inside-needle extraction method was developed through thermal polymerization of atrazine-molecularly imprinted polymer (MIP) on the internal surface of a stainless steel hollow needle, which was oxidized and silylated. The fabricated coating (MIP layer) for the needle was durable and showed very good chemical and thermal stability. It could be mounted on a glass syringe and be directly coupled with gas chromatographic (GC) systems. The parameters being effective on the coating and extraction processes, namely nature of oxidizing agent, silylation time, nature and amount of porogen, template-to-MIP components ratio, polymerization time and temperature, sample volume, flow rate, pH and ionic strength of the sample were investigated and optimized. The extraction needle showed high selectivity as well as a great extraction capacity for triazines. The extraction of atrazine, simazine, cyanazine, ametryn, prometryn and terbutryn using the fabricated extraction needle and followed by GC analysis resulted in detection limits of 2.6, 21, 24, 32, 38 and 42 ng mL−1, respectively. The fabricated needle proved to be applicable to the analysis of real samples by comparing the results obtained for non-spiked and spiked samples of grape juice, tap water and groundwater.

  相似文献   
4.
A dispersive liquid‐liquid microextraction method based on the dispersion of 1,2‐dichlorobenzene as an extraction solvent into an aqueous phase in the presence of ethanol as a dispersive solvent for the preconcentration of Co2+ and Ni2+ ions is discussed. 1‐Nitroso 2‐naphtol was used as a chelating agent prior to the extraction and the preconcentrated analyte was determined by flame atomic absorption spectrometry. The effect of various experimental parameters including the extraction and dispersive solvent type and volume, pH, amount of the chelating agent, etc. on the microextraction and complex formation was investigated for finding the optimum conditions. The enhancement factors were about 61.9 and 51.8, the calibration graphs were linear in the range of 10‐150 μgL?1 and 10‐250 μgL?1 with detection limits of 2.42 μgL?1 and 1.59 μgL?1, and RSD (n = 5) of 3.08% and 2.17% for cobalt and nickel, respectively. The method was successfully applied to the determination of Co and Ni in water and vitamin B12.  相似文献   
5.

Abstract  

A selective optode based on immobilization of 5-(p-dimethylaminobenzylidene)rhodanine on a triacetylcellulose membrane was developed for quantitative determination of Au(III). The determination procedure was performed using a simple light-emitting diode (LED)-based device as a new effort to overcome low reproducibility and repeatability problems which usually accompany optode-based determinations. The results obtained were compared with those of conventional spectrophotometric methods. The response characteristics of the sensor including dynamic range, reproducibility, response time, and lifetime are discussed in detail. This sensor was used for the determination of Au(III) in ore and electroplating liquid effluent samples with satisfactory results in comparison with flame atomic absorption spectroscopy as standard method. Under the optimum conditions, the calibration plot was linear in the concentration range of 0.3–6.0 μg cm−3. The relative standard deviations for five replicate determinations of 1.0 μg cm−3 Au(III) and the corresponding limits of detection were 1.76% and 0.12 μg cm−3, respectively.  相似文献   
6.
This study examines the difficulties college students experience when creating and interpreting graphs in which speed is one of the variables. Nineteen students, all preservice elementary or middle school teachers, completed an upper‐level course exploring algebraic concepts. Although all of these preservice teachers had previously completed several mathematics courses, including calculus, they demonstrated widespread misconceptions about the variable speed. This study identifies four cognitive obstacles held by the students, provides excerpts of their graphical constructions and verbal interpretations, and discusses potential causes for the confusion. In particular, misconceptions arose when students interpreted the behavior and nature of speed within a graphical context, as well as in situations where they were required to construct a graph involving speed as a variable. The study concludes by offering implications for the teaching and learning of speed and its interpretation within a graphical setting.  相似文献   
7.
This paper describes simple and rapid methods for the fabrication of glass and polymeric chips for routine analytical applications. The methods are easily interfaced to the general laboratory environment and do not require special clean room facilities or expensive instruments. Glass microchips were fabricated by etching with HF solution. Microfluidic channels were designed with CAD program and transferred onto a sheet of commercial polymeric self-adhesive (PSA) film by a cutter plotter. The PSA film was used as a mask for etching process. The etching rate was about 7 μm min−1. A cover glass plate was sealed on the top of etched substrate by using polycellulose (cellophane). Polymeric microchips were fabricated by sawing with a jigsaw. Commercial polycarbonate (PC) was used as a substrate and two iron sheets were used as leader masks. While this restricts us to the fabrication of straight channels, it is however, much faster and less complicated than the other methods. The chip comprised three polymeric plates and the channels were created in the middle plate. Thermal bonding was used to bond three layers of the microfluidic chip. With this method, we could achieve simple channels with the width of about 200 μm. The channel depth depends on the polymeric plate thickness. Fabricated channels were accurate without any sinuosity or sideshow.  相似文献   
8.
A simple and selective method for penicillin V potassium (PVK) determination by chemiluminescence (CL) was developed. Oxidation of PVK by alkaline hydrogen peroxide produces CL, which is greatly enhanced by N, N-dimethyl formamide (DMF) and N-cetyl-N,N,N-trimethylammonium bromide (CTMAB). Optimum conditions were established using luminometry. There is a linear relationship between the chemiluminescent peak height and the amount of PVK within the range 0.5–129.5 mg L−1, with a detection limit of 0.2 mg L−1. The coefficient of variation was 1.2% for 40 mg L−1 PVK solution (n = 7). The method is very simple, has high sensitivity and good selectivity, and is usable for process control. It was successfully utilized for the determination of PVK in pharmaceuticals and spiked human urine.   相似文献   
9.
A highly sensitive spectrophotometric method is described for the determination of trace amounts of osmium(VIII), based on its catalytic effect on the oxidation of carminic acid by hydrogen peroxide. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of carminic acid at 540 nm after 3 min of mixing the reagents. The optimum reaction conditions were 1x10(-4) mol l(-1) carminic acid, 0.013 mol l(-1) hydrogen peroxide and pH 10 at 25 degrees C. By using the recommended procedure, the calibration graph was linear from 0.1 to 1.5 ng ml(-1) of osmium; the detection limit was 0.02 ng ml(-1); the RSD for five replicate determinations of 0.2-1.4 ng ml(-1) was in the range of 1.8-4.7%. The influence of several foreign ions on osmium determination were studied and the effect of interfering ions were removed by extracting osmium into isobuthyl methyl ketone and back extracting into sodium hydroxide solution.  相似文献   
10.
A highly sensitive and selective method is described for the determination of trace amounts of nitrite based on its effect on the oxidation of carminic acid with bromate. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of carminic acid at 490 nm after 3 min of mixing the reagents. The optimum reaction conditions were 1.8×10−1 mol l−1 H2SO4, 3.8×10−3 mol l−1 KBrO3, and 1.2×10−4 mol l−1 carminic acid at 30°C. By using the recommended procedure, the calibration graph was linear from 0.2 to 14 ng ml−1 of nitrite; the detection limit was 0.04 ng ml−1; the R.S.D. for six replicate determinations of 6 ng ml−1 was 1.7%. The method is mostly free from interference, especially from large amounts of nitrate and ammonium ions. The proposed method was applied to the determination of nitrite in rain and river water.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号