首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
《Electroanalysis》2006,18(2):127-130
The voltammetric behavior of 2‐methyl‐4,6‐dinitrophenol was investigated by differential pulse voltammetry (DPV) at a nontoxic mercury meniscus‐modified silver solid amalgam electrode (m‐AgSAE). Conditions have been found for its determination by DPV at m‐AgSAE in the concentration range of 0.2 to 1 μmol L?1.  相似文献   

2.
《Electroanalysis》2003,15(22):1778-1781
The voltammetric behavior of N,N‐dimethyl‐4‐amino‐2′‐carboxyazobenzene was investigated by differential pulse voltammetry (DPV) at a mercury meniscus‐modified silver solid amalgam electrode (m‐AgSAE). Conditions have been found for its determination by DPV at m‐AgSAE in the concentration range of 0.4 to 15 μmol L?1.  相似文献   

3.
A new simple and direct electroanalytical method was developed for the determination of azidothymidine in commercial pharmaceutical preparations. It is based on differential pulse voltammetry at silver solid amalgam electrode with polished surface (p‐AgSAE) or surface modified by mercury meniscus (m‐AgSAE). The electroreduction of azidothymidine in basic media at these electrodes gives rise to one irreversible cathodic peak. Its potential in 0.05 mol L?1 borate buffer, pH 9.3 at ca. ?1050 mV is comparable to that using hanging mercury drop electrode (HMDE). Achieved limits of quantitation are in the 10?7 mol L?1 concentration range for both amalgam electrodes. According to the procedure based on the standard addition technique, the recoveries of known amounts of azidothymidine contained in pharmaceutical preparations available in capsules were 101.4±1.8% (m‐AgSAE), 100.3±3.5% (p‐AgSAE) and 102.0±1.0% (HMDE) (n=10). There was no significant difference between the values gained by proposed voltammetric methods and the HPLC‐UV recommended by the United States Pharmacopoeia regarding the mean values and standard deviations.  相似文献   

4.
The in-house prepared mercury meniscus modified solid silver amalgam electrode (m-AgSAE) was successfully applied for the detection of organophosphate pesticide tetrachlorvinphos in pH 7 buffer solution. The electrochemical performance of m-AgSAE for the reduction of tetrachlorvinphos was evaluated using cyclic voltammetry (CV), differential pulse voltammetry (DPV), and square wave voltammetry (SWV), respectively. The surface morphology of solid silver electrode (AgE), as-amalgamated solid silver amalgam electrode (AgSAE), and polished solid silver amalgam electrode (p-AgSAE) was examined by field emission scanning electron microscopy (FESEM). Among the applied techniques, DPV and SWV analysis showed a remarkable increase in the reduction peak current and provided a simple, fast, and sensitive method for the determination of tetrachlorvinphos. The electrochemical impedance spectroscopy (EIS) was used to correlate the electrocatalytic activity of AgSAE, p-AgSAE and m-AgSAE with their interfacial charge transport capabilities. Under the optimized experimental conditions, the DPV and SWV responses were linear over the 1–9 μM and 10–50 μM concentration ranges with a detection limit of 0.06 μM for DPV and 0.04 for SWV. The estimation of tetrachlorvinphos in the ground and waste water samples with the proposed method was in good agreement with that of the added amount. The proposed electrochemical method not only extends the application of non-toxic m-AgSAE, but also offers new possibilities for fast and sensitive analysis of tetrachlorvinphos and its structural analogs in environmental samples.  相似文献   

5.
Acibenzolar‐S‐methyl (ASM) is a novel fungicide applied for crop protection. A renewable silver amalgam film electrode was used for the determination of ASM in pH 3.4 Britton? Robinson buffer using square wave adsorptive stripping voltammetry (SW AdSV). The parameters of the method were optimized. The electroanalytical procedure made possible to determine ASM in the concentration range of 5×10?8–3×10?7 mol L?1 (LOD=4.86×10?9, LOQ=1.62×10?8 mol L?1). The effect of common interfering pesticides and heavy metal ions was checked. The validated method was applied in ASM determination in spiked water samples.  相似文献   

6.
The article describes the use of a fullerene (C60)‐β‐cyclodextrin conjugate, synthesized via 1,3dipolar cycloaddition, for the ultrasensitive electrochemical detection of p‐nitrophenol. This conjugate was successfully immobilized on the surface of a glassy carbon electrode and the developed device showed high activity towards p‐nitrophenol due to the synergetic effect of C60, the latter becoming highly conductive upon reduction. The determination of p‐nitrophenol was performed by using square wave voltammetry over a concentration range from 2.8×10?9 mol L?1 to 4.2×10?7 mol L?1 and the detection limit was calculated to be 1.2×10?9 mol L?1.  相似文献   

7.
Alternative electrode materials suitable to prepare novel working electrode applicable in detecting biopolymers such as nucleic acids, proteins or glycoproteins, represent a significant contribution to bio‐electroanalysis. Herein, electrodes made of vapor‐deposited thin gold films (vAuE) were used as an alternative substrate for the electrodeposition of silver amalgam particles (AgAPs), next to indium tin oxide and pyrolytic graphite, which are already used. The conditions and parameters of double pulse chronoamperometry were optimized for the most‐sensitive voltammetric detection of 4‐nitrophenol (4‐NP). The resulting electrodes were characterized by scanning electron microscope with energy dispersive X‐ray spectroscopy. While 4‐NP could not be detected by bare nonactivated vAuEs at all, their electrochemical activation offered a limit of detection (LoD) of 25 and 5 μmol.l?1 by means of CV and DPV, respectively. AgAP electrodeposited on vAuE, offered 2.5‐times lower LoDs 10 μmol.l?1 by CV and comparable LoD 5 μmol.l?1 by DPV. Advantageously, AgAPs could be repeatedly deposited on and anodically dissolved from the vAuE with a relative standard deviation 13 % of the ten‐times repeated DPV signal of 4‐NP (100 μmol.l?1). In comparison to vAuE, the vAuE‐AgAP offered about 400 mV broader potential window, which allowed detection of single strand DNA fragment labeled by osmium tetroxide?bipyridine complex down to 2 ng.μl?1 by means of DPV.  相似文献   

8.
This paper presents the application of the tubular detector based on silver solid amalgam (TD‐AgSA) for electrochemical determinations of reducible inorganic (Cd2+, Zn2+) and organic (4‐nitrophenol) compounds under flow injection analysis conditions. The newly developed TD‐AgSA is simple, robust and inexpensive. The limits of detections of Zn2+, Cd2+ and 4‐nitrophenol are 1.4×10?6, 7.0×10?7, and 5.0×10?7 mol dm?3, respectively (i.e. 0.09, 0.08 and 0.07 ppm). The obtained results proved the long‐term stability of the detector (RSD of the determination of Zn2+, Cd2+, and 4‐nitrophenol were 0.8, 0.9 and 0.8 % (n=10; cZn=7.7×10?5 mol dm?3, cCd=4.5×10?5 mol dm?3 and c4‐NPh=3.6×10?5 mol dm?3), respectively and its applicability for cathodic measurements in aqueous solutions at potentials up to ?2 V.  相似文献   

9.
This work is focused on the application of a silver solid electrode (AgE) for the development of modern voltammetric methods for the determination of submicromolar concentrations of biologically active compounds present in the environment. 8‐Nitroquinoline (8‐NQ), a well‐known chemical carcinogen, was chosen as a model substance. Differential pulse voltammetry (DPV) was used to study electrochemical behavior of 8‐NQ in different aqueous matrices. The following optimal conditions for determination of 8‐NQ in the concentration ranges from 2 to 100 µmol L?1 were used: Britton? Robinson (BR) buffer of pH 3.0, the regeneration potentials cycles (Ein=?1000 mV, Efin=?100 mV) and constant cleaning potential ?2000 mV. Practical applicability of AgE for the determination of micromolar concentrations of 8‐NQ was verified on model samples of drinking and river water.  相似文献   

10.
The voltammetric behavior of 3‐nitrofluoranthene and 3‐aminofluoranthene was investigated in mixed methanol‐water solutions by differential pulse voltammetry (DPV) at boron doped diamond thin‐film electrode (BDDE). Optimum conditions have been found for determination of 3‐nitrofluoranthene in the concentration range of 2×10?8–1×10?6 mol L?1, and for determination 3‐aminofluorathnene in the concentration range of 2×10?7–1×10?5 mol L?1, respectively. Limits of determination were 3×10?8 mol L?1 (3‐nitrofluoranthene) and 2×10?7 mol L?1 (3‐aminofluoranthene).  相似文献   

11.
A differential pulse voltammetric (DPV) method was developed for the determination of 4‐nitrophenol (4‐NP) at a newly developed silver amalgam paste electrode (AgA‐PE) in Britton–Robinson buffer pH 3.0. The electrode is based on a disposable plastic pipette tip filled with paste amalgam based on a mixture of mercury and fine silver powder (9 : 1, w/w). The experimental parameters, such as pH of Britton–Robinson buffer and activation and regeneration potential of the electrode surface were optimized. The reduction peak current dependences were linear for the concentration of 4‐NP from 0.2 to 100 μM. The method showed reproducible results with RSD (n=45) of 1.7%. The limit of determination (LOD) was 0.3 μM. The method was successfully applied for the direct determination of 4‐NP in drinking water.  相似文献   

12.
An electrodeposition oxygen‐incorporated gold‐modified screen‐printed carbon electrode (AuOSPE) was fabricated to determine the sulfite content in hair waving products. The AuOSPE showed an electrocatalytic current for sulfite at +0.4 V (vs. Ag/AgCl). Compared with a gold screen‐printed electrode (AuSPE), the AuOSPE showed a higher electrocatalytic current. The increase in the electrocatalytic current was ascribed to the increase of the oxygen incorporated with gold atom on AuOSPE. The AuOSPE coupled with a flow injection analysis (FIA) system showed excellent oxidation current for sulfite in a 0.1 mol L?1 phosphate buffer solution (PBS), pH 6.0. The linear working range for determining the sulfite content was 0.05 to 1200 mg L?1 (0.625 µmol L?1 to 15.00 mmol L?1) with a calculated detection limit of 0.03 mg L?1 (0.375 µmol L?1) (DL, S/N=3). Relative standard deviations (RSD) of 3.03 %, 2.30 % and 4.26 % were calculated for consecutive injections (n=12) of 20, 300 and 900 mg L?1 sulfite, respectively. The amount of sulfite in two hair waving products was determined by the proposed method and a standard iodometric method. The recoveries ranged from 96.18 % to 105.61 %. The AuOSPE showed high sensitivity, selectivity, stability and reproducibility for sulfite.  相似文献   

13.
《Electroanalysis》2006,18(2):186-194
The complex of osmium tetroxide with 2,2′‐bipyridine has been utilized as a probe of DNA structure and an electroactive marker of DNA in DNA hybridization sensors. It produces several voltammetric signals, the most negative of them has been observed only at mercury electrodes. This signal is of catalytic nature affording a high sensitivity of DNA determination. The catalytic current due to evolution of hydrogen in voltammetry of DNA modified by complex of osmium tetroxide with 2,2′‐bipyridine (DNA‐Os,bipy) was studied. Solid amalgam electrodes (modified with mercury menisci) of silver (m‐AgSAE), copper (m‐CuSAE), gold, and of combined bismuth and silver, were used as possible substitutes for mercury electrodes. Besides the hanging mercury drop electrode (HMDE), the catalytic current was observed only on m‐AgSAE and m‐CuSAE. Electrodes of gold and bismuth amalgams did not give the catalytic current. The detection limit of DNA‐Os,bipy on HMDE was 0.1 ng mL?1 (RSD=2.3 %, N=11), and on m‐AgSAE 0.2 ng mL?1 (RSD=3.1%, N=11). The m‐AgSAE was successfully applied as a detection electrode in double‐surface DNA hybridization experiments offering highly specific discrimination between complementary (target) and nonspecific DNAs, as well as determination of the length of a repetitive DNA sequence. The m‐AgSAE has proved a convenient alternative to the HMDE or carbon electrodes used for similar purposes in previous work.  相似文献   

14.
Differential pulse voltammetry (DPV) at a carbon fibre rod electrode (CFRE) and a capillary carbon paste electrode (CPE) have been used for the determination of pesticides cymoxanil and famoxadone, respectively. In the cathodic potential range, optimum conditions were found for the determination of cymoxanil by DPV at CFRE at pH 4 with limit of quantification (LQ) of 5.9×10?7 mol L?1. In the anodic area, determination of famoxadone by DPV at CPE was performed at optimum pH 2 with LQ=1.4×10?7 mol L?1. Practical applicability of the newly developed methods was verified on spiked samples of river water and soil.  相似文献   

15.
A sensitive and selective method for the determination of Sb3+ based on the formation of its complexes with 8‐hydroxyquinoline (HQ) and 8‐hydroxyquinoline‐5‐sulfonic acid (HQS) is proposed. The best analytical conditions are: pH 5.4 and 2.2 for HQ and HQS, respectively; CHQ from 15.0 to 25.0 µmol L?1 and CHQS from 70.0 to 200.0 µmol L?1. The detection limits are 100.0 and 14.0 ng L?1 (tacc=30 s) for Sb3+ with HQ and HQS, respectively. The method using HQS as ligand has a 2.2‐fold higher sensitivity than that with HQ and the former was chosen for Sb3+ determination.  相似文献   

16.
The electrochemical behavior of oxadiargyl at a graphene‐paste electrode modified with an azo dye, 2‐(4‐((4‐acetylphenyl)diazenyl)phenylamino)ethanol (ADPE), ADPE/MGRPE was investigated. The modified electrode showed high electrocatalytic activity toward oxadiargyl. The apparent electron transfer rate constant (ks) and charge transfer coefficient (α) between electrode and ADPE were 1.16 s?1 and 0.41, respectively. The differential pulse voltammetry response of the modified graphene‐paste electrode was linear against the concentration of oxadiargyl in the range from 0.03 to 1.4 mg L?1. The limit of detection was found to be 1.3 µg L?1 (S/N=3). The practical analytical utility of this electrode was demonstrated by measurement of oxadiargyl in river water, soil and rice samples.  相似文献   

17.
Ewa Niewiara 《Electroanalysis》2013,25(8):2007-2014
An adsorptive stripping voltammetric (AdSV) procedure for the determination of monobutyltin in aqueous media at a silver liquid amalgam film‐modified silver solid amalgam annular band electrode (AgLAF? AgSAE) is described. Determination of monobutyltin proceeds in two steps. At the beginning monobutyltin ions (BuSn3+) are accumulated from 0.1 M NH4NO3 and 10 % ethanol solution at a potential of ?0.2 V, than the BuSn0 film is preconcentrated at the working electrode surface at a potential of ?0.7 V. After this step the DP AdSV voltammogram is recorded. The analytical parameters and the procedure of the electrode regeneration and activation were optimized. The calibration curve of monobutyltin in the range 0.02–0.30 mg L?1 is linear (r=0.9973). The detection limit for 5 s of preconcentration, calculated as 3σ of the blank was equal to 0.004 mg L?1, repeatability of the peak current was 1.8 % (n=5). Repeatability and sensitivity of monobutyltin determination depends strongly on the analyzed solution properties, measurement conditions and the working electrode quality. The proposed procedure was tested by means of monobutyltin determination in tap waters.  相似文献   

18.
A novel silsesquioxane material was synthetized and used as a stabilizing agent for silver nanoparticles. This hybrid material was characterized by FTIR, 29Si CP‐MAS NMR, 13C DEPT 135° NMR and TGA techniques and the silver nanoparticles were characterized from DLS, UV‐Vis spectroscopy, zeta‐potential, TEM and SAXS results. The silver nanoparticles obtained were spherical in shape with a diameter of 3.74 nm. The nanomaterial was successfully applied in the modification of a glassy carbon electrode and a pronounced current response was obtained in the determination of the biomarker 4‐nitrophenol. Quantum chemical calculations, using density functional theory, were also performed in order to evaluate the redox properties of the analyte. Two different linear ranges were obtained applying optimal square wave voltammetry conditions. The reduction peak currents obtained were linear for 4‐NP concentrations in the ranges of 0.29 to 1.50 μmol L?1 (Ed=?0.6 V and td=20 s) and 2.75 to 31.5 μmol L?1, with a theoretical (signal to noise=3) limit of detection of 0.05 μmol L?1 (td=20 s). The proposed method was successfully applied to the determination of 4‐NP in synthetic serum samples at different levels of 4‐NP with a recovery range of 94–101 %. Validation was performed using a comparative method through the capillary electrophoresis (CE) technique.  相似文献   

19.
This work reports the application of screen‐printed electrodes bulk‐modified with bismuth precursors to the voltammetric determination of 2‐nitrophenol (2‐NP), 4‐nitrophenol (4‐NP) and 2,4‐dinitrophenol (2,4‐DNP) in water samples. A bismuth film was formed at the electrode surface via in situ reduction of the precursor compound contained in the electrode matrix by cathodic polarization at ?1.20 V. The formation of bismuth layer at the precursor‐modified electrodes was assessed by cyclic voltammetric (CV) at different pH values and by optical techniques. The target nitrophenols were voltammetrically determined by recording their reduction peaks in the differential pulse (DP) mode. The composition and content of the precursor compounds in the printed ink and the effect of the pH of the supporting electrolyte on the DP reduction currents of the 3 target nitrophenols were studied. The limits of quantification (LOQs) in three water matrices (distilled water, tap water and surface water) were in the range 1.1–2.2 µmol L?1. Using a simple solid‐phase extraction (SPE) procedure with Lichrolut EN cartridges and elution with methanol, a preconcentration factor of 100 was achieved; the LOQs were 0.021, 0.027 and 0.025 µmol L?1 for 2‐NP, 4‐NP and 2,4‐DNP, respectively. The recoveries of samples spiked with the 3 target nitrophenols at two concentration levels (0.04 and 0.1 µmol L?1) were always >87 %.  相似文献   

20.
The paper presents the use of a renewable silver‐amalgam film electrode (Hg(Ag)FE) for the determination of the insecticide thiamethoxam (TMO) in Britton‐Robinson buffer pH 7.0 (LOD=0.25 µg mL?1, LOQ=0.70 µg mL?1) by direct cathodic square‐wave voltammetry (SWV). The voltammetric response for TMO obtained at this electrode was the same as that obtained with a hanging mercury drop electrode, represented by two distinct reduction peaks. Since the electron transfer processes are coupled with chemical reactions involving protons, the SWV signals strongly depend on the pH of the supporting electrolyte. The developed Hg(Ag)FE‐SWV method was tested for the determination of TMO in spiked honey and river water samples, as well as for the determination of its content in the commercial formulation Actara 25 WG.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号