首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A rapid multiresidue method for the analysis of 72 pesticides has been developed using a single injection with low-pressure gas chromatography/tandem mass spectrometry (LP-GC/MS/MS). The LP-GC/MS/MS method used a short capillary column of 10 m x 0.53 mm i.d. x 0.25 microm film thickness coupled with a 0.6 m x 0.10 mm i.d. restriction at the inlet end. Optimal LP-GC conditions were determined which achieved the fastest separation in MS/MS detection mode. Also MS/MS conditions were optimized in order to increase sensitivity and selectivity. The analytical parameters of the LP-GC/MS/MS method were compared with those obtained by GC/MS/MS using a conventional capillary column (30 m x 0.25 mm i.d. x 0.25 microm film thickness). Better precision and sensitivity values were obtained with the LP-GC/MS/MS approach. The limits of detection (LOD) of the compounds ranged from 0.1 to 14.1 microg L(-1) for LP-GC/MS/MS, lower than those obtained for conventional GC/MS/MS that ranged from 0.1 to 17.5 microg L(-1). The peak widths obtained with the short column in LP-GC are similar to those obtained using conventional capillary GC columns, and the peaks can be successfully identified by MS/MS detection with the conventional scan speed of ion-trap instruments. In addition, the analysis time was significantly reduced with LP-GC/MS/MS (32 min) versus GC/MS/MS (72 min), allowing the number of samples analyzed per day in a routine laboratory to be doubled.  相似文献   

2.
An injector designed for automatic direct liquid injection into narrow bore capillary GC columns has been constructed and evaluated. The tip of the syringe needle is aligned with, and positioned close to, the column entrance in a small, pressurized cavity: when the sample is dispensed it is immediately forced into the column by the action of the surrounding carrier gas. A standard autosampler equipped with a standard stainless steel syringe needle was utilized for at-column sample transfer into 100 μm i.d. columns. RSD values for n-alkanes were between 0.1 and 0.3% for relative area counts and approximately 1% for absolute area counts.  相似文献   

3.
The chromatographic performance of 10 m × 100 μm i.d. capillary columns, coated with different stationary phases, was studied. TZ-ū plots were measured at different temperature program rates. The polarity and selectivity are strongly influenced by the temperature program rate. The analysis time depends on the capacity ratio and the selectivity factor; stationary phase selection thus is an important aspect in high speed capillary GC. A number of applications is presented and the applicability of split injection is discussed.  相似文献   

4.
色谱与色谱/质谱法相结合分析热裂解汽油C9馏分   总被引:3,自引:0,他引:3  
王华  刘文民  徐媛  关亚风 《色谱》2006,24(6):615-618
采用毛细管气相色谱-氢火焰离子化检测器(CGC-FID)和气相色谱-质谱法(GC/MS)分析了热裂解汽油C9 馏分的组成。实验使用PONA毛细管气相色谱柱(100 m×0.25 mm i.d.×0.5 μm),根据烃类化合物在PONA柱上的保留规律,以正构烷烃标样保留值作为碳数分布依据,定量分析了裂解汽油C9 馏分中烃类化合物的碳数分布和单体烃含量;用GC/MS联用技术和CGC保留值定性法相结合对裂解汽油C9 馏分中相对含量大于0.2%的39种化合物进行了定性。  相似文献   

5.
The aim of the present study was to set‐up a Fast gas chromatography/mass spectrometry method for the analysis of cholesterol oxidation products (COPs). A silylated mixture of seven oxysterol standards was injected into a Fast GC/MS system. A capillary GC column (10 m×0.1 mm internal diameter×0.1 μm film thickness) coated with 95% dimethyl‐ and 5% diphenyl‐polysiloxane, was used. The method gave a fast (total analysis time=3.5 min) and satisfactory resolution (R>1.2) of the COPs standards, with a good repeatability and sensitivity, similar to those of conventional GC/MS; recoveries were tested on mice liver. Fast GC/MS method suitability for COPs analysis in food was also tested on an oxidized sardine fillet, which had been previously saponified and purified by NH2 solid‐phase extraction (SPE); a good repeatability and sensitivity was also obtained. The analytical performance of the Fast GC/MS method for the determination of COPs, together with the consequent significant reduction of the analysis time and consumables, demonstrates that Fast GC/MS represents a valid alternative to conventional GC/MS and evinces the great potential of such an analytical technique, which could be applied for both food and biological samples.  相似文献   

6.
A unified approach to sequential gas and supercritical fluid Chromatography using 50 μm i.d. open tubular columns is described. Sample introduction is performed by means of a rotary injection valve. In order that linear velocities can be optimized independently, a second rotary valve in the chromatographic oven is used to direct the flow of column eluate to the flame ionization detector through either fused silica tubing in GC, or a frit restrictor in SFC. Applications of sequential GC-SFC on a 50 μm i.d. open tubular column are demonstrated, and comparisons made between sequential GC-SFC on 50 and 100 μm i.d. columns.  相似文献   

7.
建立了全二维气相色谱-飞行时间质谱(GC×GC-TOF MS)分析卷烟主流烟气中中性化学成分的方法。以较长的弱极性柱HP-5MS(50 m×0.2 mm i.d.×0.33μm)作为第一维柱,较短的薄液膜中等极性柱DB-17MS(1.7 m×0.1 mm i.d.×0.1μm)作为第二维柱,对优质烟叶单料卷烟烟气的中性成分进行定性分析,经过人工纠错等分析初步鉴定出匹配度大于700的1 464种成分,重点讨论了中性香味羰基化合物全二维点阵的谱图特征,为烟气和复杂体系的深入研究提供了方法学基础。  相似文献   

8.
The applicability of comprehensive two-dimensional gas chromatography (GC×GC) for flavonoids analysis was investigated by separation and identification of flavonoids in standards, and a complex matrix natural sample. The modulation temperature was optimized to achieve the best separation and signal enhancement. The separation pattern of trimethylsilyl (TMS) derivatives of flavonoids was compared on two complementary column sets. Whilst the BPX5/BPX50 (NP/P) column set offers better overall separation, BPX50/BPX5 (P/NP) provides better peak shape and sensitivity. Comparison of the identification power of GC×GC-TOFMS against both the NIST05 MS library and a laboratory (created in-house) TOFMS library was carried out on a flavonoid mixture. The basic retention index information on high-performance capillary columns with a non-polar stationary phase was established and database of mass spectra of trimethylsilyl derivatives of flavonoids was compiled. TOFMS coupled to GC×GC enabled satisfactory identification of flavonoids in complex matrix samples at their LOD over a range of 0.5-10 μg/mL. Detection of all compounds was based on full-scan mass spectra and for each compound a characteristic ion was chosen for further quantification. This study shows that GC×GC-TOFMS yields high specificity for flavonoids derived from real natural samples, dark chocolate, propolis, and chrysanthemum.  相似文献   

9.
In trace analysis by capillary GC it is often desirable to use larger than normal injection volumes to obtain sufficient sensitivity. This, however, results in a wider solvent peak and tailing, and may reduce column efficiency. This paper describes the use of a short length of a capillary precolumn coated with a stationary phase of polarity similar to that of the sample solvent and a film thickness greater than that of the analytical column; provided the right combination of polarities of injection solvent and liquid phases are used, the precolumn focuses the solvent band, thereby enabling the maximum injection volume to be increased without measurably reducing efficiency. Typical precolumn dimensions are 1 m length, 0.32 mm i.d., and 0.5 μm stationary phase film thickness. Using a precolumn increases the maximum injection volume up to 8 or 10 μl, or three times that appropriate for a conventional analytical column, with little or no loss in efficiency.  相似文献   

10.
Narrow-bore column liquid chromatography coupled on-line with capillary gas chromatography (LC/GC) is used for the determination of polychlorinated biphenyls (PCBs) in sediment via a heart-cutting technique. This method is compared with a method in which two off-line column clean-up steps are used with subsequent analysis by capillary gas chromatography. For the LC/GC analysis the recovery of PCBs was 90–100%. For two sediment samples from the river Meuse the LC/GC and the other, more laborious method showed good agreement.  相似文献   

11.
A modification of a packed GC injector to a capillary injector is presented using a simple device which is connected to the GC column by an adsorption-free connector. It permits injections of large sample volumes up to 500 μl hexane solutions on normal 0.3 mm i.d. capillary columns. No special requirements for the stationary phase are necessary. Involatile residues remain inside the device which can be exchanged easily. High performance of separation and quantification is achieved.  相似文献   

12.
The coating speed upon static coating of glass capillary columans was evaluated in terms of inner diameter and length of the column, viscosity and pressure of solvent vapor, etc. From the equation obtained it can be shown that a smaller diameter of a microbore column restricts solvent vapor transfer to the orifice of the column drastically. To compensate for this restriction, a higher pressure at the meniscus is needed. As an alternative to using a higher coating temperature, application of more volatile solvents such as n-butane and isobutane is proposed. Several glass capillary columns (130 μm i.d.) were coated with SE-54 dissolved inpentane-acetone mixed with n-butane or isobutane and the column performances were evaluated. Selection of these solvents permitted free release static coating of ca. 100 μm columns at lower or even ambient temperatures and they were equally suitable as commonly applied solvents (e.g. pentane) to coat highly efficient columns.  相似文献   

13.
The technique of choice for many types of forensic drug confirmations is gas chromatography/mass spectrometry (GC/MS). Significant amounts of analytical time can be involved in a GC/MS run. The use of a 0.1 mm i.d. fused silica capillary column with hydrogen carrier gas can significantly increase the speed of an analysis without sacrificing resolution. Nanogram levels of underivatized drugs, from amphetamine to strychnine, can be eluted in less than twelve minutes. The multitasking system permits data acquisition, while performing data reduction on the previous run.  相似文献   

14.
The application of vacuum GC has several advantages over pressurized GC. One of the key characteristics is that the optimal gas velocity is very high. Combined with short capillary columns of wide internal diameter, this results in short analysis times using standard GC‐MS equipment. To make vacuum GC possible using a GC‐MS system, a restriction must be positioned at the injection side of the column. This restriction is usually made of deactivated 0.1 mm i.d. fused‐silica tubing which is coupled to the analytical column. Such restrictions will work, but practical challenges are found in coupling, reducing dead volume and robustness. A new way of making restrictions is by incorporating the restriction into the injection port. Using well‐defined short pieces of fused silica with internal diameter of 0.025 mm, one can make a restriction using a Press‐Tight® type connector, and position this inside the injection port. By doing this, the restriction is very short and at high temperature all the time. Activity plays a minimal role, and also leaks will not be an issue as the coupling is in 100% inert gas. Data obtained using this concept is promising as vacuum GC becomes easier and more robust.  相似文献   

15.
The present paper describes constructional details and evaluations of an at-column injector for capillary GC. Injections were made via a sample loop on a 0.32 mm i.d. capillary column. Two rotary valves were employed to allow a wash of the sample loop and a backflush of the transfer line. Repeatability, calculated from absolute area counts for n-alkanes was between 0.3–1% RSD, for injected sample volumes between 5 and 100 μl. Promising results were also obtained with syringe-based injections on narrow bore (100 μ i.d.) columns. Repeatability on the basis of normalized area counts was in the order of 0.1–0.2% RSD, while solvent tailing was practically absent.  相似文献   

16.
A new all-glass interface for GC/MS designed to fully exploit the potential of glass capillary columns is described. The system works in the open split mode and has high versatility with respect to column changing. It is especially suitable for mass spectrometers, which are not exclusively dedicated to GC/MS work. Two chromatograms illustrate the properties of the described interface.  相似文献   

17.
Tan YL  Quanci JF 《Talanta》1985,32(7):577-578
A packed-column gas-chromatograph/mass-spectrometer (GC/MS), Hewlett-Packard 5982, was modified to accommodate fused silica capillary columns. The original GC/MS interface and chemical-ionization sample-line in the ion-source were changed to allow the end of a fused silica capillary column to enter the ion-chamber directly. For chemical-ionization operation, the reagent gas was brought into the MS through the direct-insertion probe port. The calibration compound was introduced through the electron-impact sample-inlet, which simplified the operation. The modified system yields higher sensitivity and more efficient separation, as well as simpler operation, without sacrificing any original instrument functions.  相似文献   

18.
The potential application of capillary column supercritical fluid chromatography (SFC) and SFC/mass spectrometry (SFC/MS) for the separation and analysis of mycotoxins of the trichothecene group was examined. Trichothecenes present significant analytical problems for both gas and liquid chromatography with a major difficulty for the latter being the lack of sufficiently sensitive and selective detectors. Supercritical carbon dioxide mobile phases at temperatures up to 100 degrees C were used with deactivated fused silica columns coated with crosslinked stationary phases. Separations were obtained under pressure ramped conditions using long (15 m) 50-micron i.d. columns for several trichothecenes (diacetoxyscirpenol, deoxynivalenol, and T-2 toxin) and related higher molecular weight macrocyclic (roridin and verrucarin) trichothecenes. In addition, new rapid pressure programming techniques with short (less than 2m) 25- to 50-micron i.d. capillary columns were used to obtain fast separations in as little as 1 min. SFC/MS with ammonia chemical ionization provided high selectivity and sensitive detection (with approximately 1-pg detection limits) for trichothecene mixtures. The extension to complex sample matrices is discussed and the application of selective MS/MS detection is demonstrated.  相似文献   

19.
Nanoscale separation techniques, nanoscale packed capillary columns (75 μm id), and capillary zone electrophoresis (CZE), on-line with electrospray mass spectrometry (ESI/MS), were applied to the separation of a series of ten macrolide antibiotics. Both techniques use sub-microliter-per-minute flow rates through the analytical column and therefore require an electrospray probe that incorporates coaxial sheath flow. Positive ion electrospray mass spectra of these compounds yielded mainly protonated molecules. Fragmentation to yield structurally significant fragment ions was achieved by collision-induced dissociation (CID) at increased skimmer voltages. Separations were achieved using both techniques, with CZE/ESI/MS showing improved peak shapes and detection limits combined with faster analysis times. Nanoscale packed capillary columns provided better chromatographic resolution and was less susceptible to peak broadening caused by overloading of the analytes.  相似文献   

20.
A new device for carbonyl compounds based on coupling on-line and miniaturizing both, sample pretreatment and chromatographic separation, is reported. Two capillary columns, a GC capillary column (95% methyl-5% phenyl substituted backbone, 70 cm × 0.32 mm i.d., 3 μm film thickness) in the injection valve for in-tube solid-phase microextraction (IT-SPME) and a Zorbax SB C18 (150 mm × 0.5 mm i.d., 5 μm particle diameter) LC capillary column were employed. Different combinations of IT-SPME and derivatization using 2,4-dinitrophenylhydrazine (DNPH) were examined for mixtures containing 15 carbonyl compounds (aliphatic, aromatic and unsaturated aldehydes and ketones). A screening analysis of aqueous extracts of atmospheric particulate PM(10) was carried out. Moreover, the possibility of coupling IT-SPME and conventional liquid chromatography is also tested. Derivatization solution and IT-SPME coupled to capillary liquid chromatography provided the best results for achieving the highest sensitivity for carbonyl compounds in atmospheric particulate analysis. Detection limits (LODs) using a photodiode array detector (DAD) were ranged from 30 to 198 ng L(-1), improving markedly those LODs reported by conventional SPME-LC-DAD.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号