首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
Schistosoma mansoni infection in mice has been fingerprinted using CE to study the capabilities of this technique as a diagnostic tool for this parasitic disease. Two modes of separation were used in generating the electrophoretic data, with each untreated urine sample the following methods were applied: (i) a fused-silica capillary, operating with an applied potential of 18 kV, in micellar EKC (MEKC) and (ii) a polyacrylamide-coated capillary, operating with an applied potential of -20 kV under zonal CZE conditions. By combining normal and reverse polarities in the data treatment we have extracted more information from the samples, which is a better approach for CE metabolomics. The traditional problems associated with variability in electrophoretic peak migration times for analytes were countered by using a dynamic programming algorithm for the electropherograms alignment. Principal component analyses of these aligned electropherograms and partial least square discriminant analysis (PLS-DA) data are shown to provide a valuable means of rapid and sample classification. This approach may become an important tool for the identification of biomarkers, diagnosis and disease surveillance.  相似文献   

2.
Capillary electrophoretic analysis of individual submicrometer size particles has been previously done using custom-built instruments. Despite that these instruments provide an excellent signal-to-noise ratio for individual particle detection, they are not capable of performing automated analyses of particles. Here we report the use of a commercial Beckman P/ACE MDQ capillary electrophoresis (CE) instrument with on-column laser-induced fluorescence (LIF) detection for the automated analysis of individual particles. The CE instrument was modified with an external I/O board that allowed for faster data acquisition rates (e.g. 100 Hz) than those available with the standard instrument settings (e.g. 4 Hz). A series of eight hydrodynamic injections expected to contain 32 +/- 6 particles, each followed by an electrophoretic separation at -300 V cm(-1) with data acquired at 100 Hz, showed 28 +/- 5 peaks corresponding to 31.9 particles as predicted by the statistical overlap theory. In contrast, a similar series of hydrodynamic injections followed by data acquisition at 4 Hz revealed only 8 +/- 3 peaks suggesting that the modified system is needed for individual particle analysis. Comparison of electropherograms obtained at both data acquisition rates also indicate: (i) similar migration time ranges; (ii) lower variation in the fluorescence intensity of individual peaks for 100 Hz; and (iii) a better signal-to-noise ratio for 4 Hz raw data. S/N improved for 100 Hz when data were smoothed with a binomial filter but did not reach the S/N values previously reported for post-column LIF detection. The proof-of-principle of automated analysis of individual particles using a commercially available CE system described here opens exciting possibilities for those interested in the study and analyses of organelles, liposomes, and nanoparticles.  相似文献   

3.
Phantom mutation hotspots in human mitochondrial DNA   总被引:7,自引:0,他引:7  
Phantom mutations are systematic artifacts generated in the course of the sequencing process. Contra common belief these artificial mutations are nearly ubiquitous in sequencing results, albeit at frequencies that may vary dramatically. The amount of artifacts depends not only on the sort of automated sequencer and sequencing chemistry employed, but also on other lab-specific factors. An experimental study executed on four samples under various combinations of sequencing conditions revealed a number of phantom mutations occurring at the same sites of mitochondrial DNA (mtDNA) repeatedly. To confirm these and identify further hotspots for artifacts, > 5000 mtDNA electropherograms were screened for artificial patterns. Further, > 30 000 published hypervariable segment I sequences were compared at potential hotspots for phantom mutations, especially for variation at positions 16085 and 16197. Resequencing of several samples confirmed the artificial nature of these and other polymorphisms in the original publications. Single-strand sequencing, as typically executed in medical and anthropological studies, is thus highly vulnerable to this kind of artifacts. In particular, phantom mutation hotspots could easily lead to misidentification of somatic mutations and to misinterpretations in all kinds of clinical mtDNA studies.  相似文献   

4.
The electrophoretic mobility of DNA fragments that differ by a single 3′‐terminal nucleotide was assessed by capillary electrophoresis. This was accomplished using dideoxy sequencing with a 5′‐fluorescently labelled primer to generate DNA fragments with 3′‐hydrogen ends. The resulting DNA fragments were electrophoresed on the ABI 3730 automated capillary sequencer, and the data were analysed with the GeneMapper software to determine the electrophoretic mobility differences on addition of a 3′‐terminal nucleotide. It was found that the 3′‐terminal nucleotide gave rise to different electrophoretic mobility profiles depending on the identity of the terminal nucleotide. The apparent electrophoretic mobility was (faster) –C > ?A > ?T > ?G (slower). The C‐terminated fragments were the fastest and the G‐terminated fragments the slowest, relative to other nucleotides. It was proposed that the terminal nucleotide effect was due to changes in partial net charges on the nucleotides that resulted in alterations in the electrophoretic mobility of the DNA fragments in the automated capillary DNA sequencer. Other alternative explanations are also discussed. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
Song JM  Yeung ES 《Electrophoresis》2001,22(4):748-754
Poly(vinyl pyrrolidone) solution was used as a separation matrix in capillary electrophoresis for DNA sequencing. Four-label four-color detection was performed for base calling. Dye-labeled DNA showed large mobility shifts at normal conditions for DNA separation. Temporal correction of mobility shifts was achieved by normalizing with respect to pure peaks that are without spectral interference or temporal overlap at each color channel. To achieve even better performance, a DNA separation condition that does not require corrections for mobility shifts was found. Dichlororhodamine-labeled DNA fragments showed ideal electrophoretic behaviors according to DNA size in the presence of 10 M urea. The base-calling accuracy of dichlororhodamine-labeled M13mp18 and PGEM/U DNA were 99.3% for 333 bases and 99% for 315 bases, respectively. Base calling of unknown DNA samples obtained in the presence of 10 M urea showed 99.1% accuracy.  相似文献   

6.
By transforming the time-based x-axis of electropherograms in capillary zone electrophoresis (CZE) into the corresponding effective mobility-scale, we propose a simple and robust data representation for a better qualitative and quantitative capillary electrophoresis (CE) analysis. The time scale of the raw electrophoretic data (detection signal versus time) is transformed into an effective electrophoretic mobility scale (mu eff-scale) with account of the electroosmotic flow (EOF) peak or of an internal standard of known effective mobility. With the new scaling (detection signals versus effective mobility), the obtained electropherograms are more representative of the velocity-based electrophoretic separation and the comparison of complete electropherograms is directly possible. This is of importance when tracking peaks in real samples where alteration in EOF stability can occur or when comparing electrophoretic runs from different experimental setups (independence in column length and voltage). Beside the qualitative possibilities, a quantitative improvement is achieved in the mu eff-scale with significant better peak area reproducibility and equal to more precision in quantitative analysis than with the primary time-scale integration.  相似文献   

7.
We have plotted electropherograms in capillary zone electrophoresis (CZE) as a function of the quantity of electric charge (Q) in order to eliminate the dependency of the analyte peak areas, as well as that of the migration times, upon both the capillary temperature and the applied voltage. The procedure is based on an idea of a migration index (MI) and an adjusted migration index (AMI) which were originally proposed by Lee and Yeung. The value of Q is measured accurately and calculated easily because it is given by a product of the electrophoretic current and the migration times, where the index MI is derived by dividing the value of Q by the effective volume of the capillary. By calculating the CZE peak area from the newly plotted electropherogram, improvement in precision in quantitative analysis is expected. Concerning AMI, careful treatment is required in its application to analyte peaks whose migration time is close to that of the neutral marker. Experimental data and discussions concerning the migration indices are presented.  相似文献   

8.
We present a novel method for the automated detection of fragments showing dissimilar expression in mRNA differential display. The analysis is based on aligning the numerical electrophoretic lane data in respect of a given distance function defined on a set of fragments, or signal peaks in general. We presume that significant dissimilarities between peaks result in extreme score values computed for aligned peak pairs. Whereas in sequence comparison, an overall sequence similarity score is conventionally used, the current method defines a special dissimilarity score for searching the peak pairs showing the largest relative differences between the lanes. The output of the analysis is a highly reduced list of peak pairs, along with a set of associated features extracted from the lanes. Only the peaks of this list need to be visually confirmed instead of the vast amount of peaks in the original electrophoretic results. The results obtained by the algorithm correlate well with results of visual evaluation of the same electropherograms. The current algorithm may be applied to the study of complex expression patterns in multiple lanes and, in general, to automated recognition of variously defined patterns of quantitative electrophoretic data.  相似文献   

9.
Song JM  Yeung ES 《Electrophoresis》2000,21(4):807-815
A simple base-calling scheme based on four-label multicolor detection is suggested for DNA sequencing. The entire spectra of the dye labels were used for identification. Specifically, the maxima of the emission spectra rather than the intensity ratios at selected wavelengths are used to provide excellent discrimination. Capillary gel electrophoresis was used for the separation of DNA fragments. Data acquisition and analysis compatible with fast and high-throughput imaging detection was accomplished. The accuracy of base calling of PGEM/U DNA from the raw data obtained with 5 nm and 7 nm spectroscopic resolution were 98.4% for 386 bases and 98.4% for 385 bases. Base calling of M13mp18 DNA showed 98.3% accuracy for 420 bases.  相似文献   

10.
We report initial results of a VAMAS/TWA2 project to evaluate procedures for automated peak detection in X‐ray photoelectron spectra. As a reference for investigations of the efficiency of automated peak‐detection software, we report the efficiency of visual peak detection in three test spectra. It was found that (i) characteristics of analysts are grouped into four categories using principal component analysis (PCA); the first participant group to detect large numbers of peaks for the three test spectra, the second one to detect small numbers of peaks for them, the third one to detect similar numbers of peaks, and the fourth one to detect a relatively large number of peaks for one of them and small numbers for two of them, (ii) scattering of detected peak numbers seems to depend on detection of medium‐intensity peaks because of participants' subjectivity or ambivalence for judgment of intensity, and (iii) the peaks that are detected by the analysts with a detectability more than 75% almost correspond to the peak signal‐to‐noise(S/N) ratio of more than 10 in logarithmic expression. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

11.
The migration process in capillary electrophoresis is obtained by using a high-voltage power supply, and the basic idea is to keep the control on the migration velocity of the analytes by controlling either the applied voltage or current. The effectiveness of this control has impact on the resulting electropherogram and, thus, in the identification and quantification of the analytes. Although the usual electropherogram is the record of the detector signal as a function of time, other two domains should be considered: charge and mobility. Both mathematical modeling and experimental results were used to evaluate the two different approaches for controlling the electrophoretic migration and the resulting time-, charge-, and mobility-based electropherograms. The main conclusions are (1) the current-controlled mode is superior to the voltage-controlled mode; (2) when the first mode cannot be implemented, the electrophoretic current should be monitored to improve the identification and quantification procedures; and (3) the consistent monitoring of the electrophoretic current allows the implementation of the charge-based electropherogram and the mobility spectrum. The first one is advantageous because the peak position is more reproducible, and the peak area is more resistant to change than the ones from the time-based electropherogram. The mobility spectrum has the additional advantage of being more informative about the mobility of the analytes. Although peak area is less robust, the spectrum may also be used for quantitation when the number of plates is greater than 103.  相似文献   

12.
Two new algorithms for automated processing of liquid chromatography/mass spectrometry (LC/MS) data are presented. These algorithms were developed from an analysis of the noise and artifact distribution in such data. The noise distribution was analyzed by preparing histograms of the signal intensity in LC/MS data. These histograms are well fit by a sum of two normal distributions in the log scale. One new algorithm, median filtering, provides increased performance compared to averaging adjacent scans in removing noise that is not normally distributed in the linear scale. Another new algorithm, vectorized peak detection, provides increased robustness with respect to variation in the noise and artifact distribution compared to methods based on determining an intensity threshold for the entire dataset. Vectorized peak detection also permits the incorporation of existing algorithms for peak detection in ion chromatograms and/or mass spectra. The application of these methods to LC/MS spectra of complex biological samples is described.  相似文献   

13.
CE–MS is increasingly gaining momentum as an analytical tool in metabolomics, due to its ability to obtain information about the most polar elements in biological samples. This has been helped by improvements of robustness in peak identification by means of mobility-scale representations of the electropherograms (mobilograms). As a necessary step toward facilitating the use of CE–MS for untargeted metabolomics data, the authors previously developed and introduced ROMANCE, a software automating mobilogram generation for large untargeted datasets through a simple and self-contained user interface. Herein, we introduce a new version of ROMANCE including new features such as compatibility with other types of data (targeted MS data and 2D UV-Vis absorption-like electropherograms), and the much needed additional flexibility in the transformation parameters (including field ramping and the use of secondary markers), more measurement conditions (depending on detection and integration modes), and most importantly tackling the issue of quantitative peak conversion. First, we present a review of the current theoretical framework with regard to peak characterization, and we develop new formulas for multiple marker peak area corrections, for anticipating peak position precision, and for assessing peak shape distortion. Then, the new version of the software is presented and validated experimentally. We contrast the multiple marker mobility transformations with previous results, finding increased peak position precision, and finally we showcase an application to actual untargeted metabolomics data.  相似文献   

14.
For facilitated genotypic analysis of multiple endocrine neoplasia type 1 (MEN1), a familial syndrome associated with tumors of the parathyroid and neuroendocrine tissues, we developed two screening methods, heteroduplex mutation assay (HMA) and mutation detection gel analysis (MDGA), both based on electrophoretic discrimination of polymerase chain reaction (PCR) products, to detect the mutations. Forty-three genomic DNA samples were used for the evaluation of these techniques. The whole coding region of MEN1 was PCR-amplified with fluorescent primers and then denatured/renatured before electrophoresis on an automated sequencer. 100% of the mutations were detected, subsequently confirmed and identified by sequencing. "Negative" samples were used to evaluate the specificity and reproducibility of the two techniques. The combination of the two methods allows high throughput cost-effective mutation screening which is less laborious than systematic sequencing of the whole coding region of MEN1. Together, these methods provide an efficient screen for MEN1 mutations.  相似文献   

15.
Recently, we developed a family of high-performance automated capillary DNA sequencing instruments based on a single-photon detection of fluorescently labeled DNA fragments. Our machines employ digital and broadband techniques, essential for achieving superior instrument sensitivity and dynamic range. In the present paper, we discuss limitations of the instrument's performance caused by the nonlinearity of single-photon detectors as well as methods for nonlinearity compensation which increase the detection dynamic range and base-calling accuracy.  相似文献   

16.
A new approach based on the effect of pressure in CZE is suggested for acceleration of particle migration in electrophoretic runs resulting in reduction of the analysis time. It provides conditions for studying fast processes in suspensions. The effect of pressure on the migration of silica spheres with average diameters of 100, 150, and 390 nm was studied by CZE at an applied voltage of 25 kV. The particle hydrodynamic behavior was also investigated under the same capillary dimensions and BGE composition. The total particle mobility (excluding the average flow rate) was found to increase with increasing the pressure applied and particle size. The particle migration mechanism explaining the effect of pressure on particle velocity was shown to be almost the same as in wide‐bore hydrodynamic chromatography. It is based on changing radial distribution of particle concentration along the capillary cross section depending on particle diffusivity. On the basis of this mechanism appearance of a zone of negatively charged particles in electropherograms ahead of the marker peak can be explained.  相似文献   

17.
The development of an efficient method for high-throughput analysis of multiple electropherograms or chromatograms collected in series is presented. The method, encoded in a computer program designated "Cutter", utilizes batch processing for determining chromatographic figures of merit (CFOM) including peak centroid times, heights, areas, signal-to-noise ratios (S/N), variance (sigma2), skew, excess, and plate number (N) across a set of separations collected serially. The software was validated using simulated data with varying S/N, skew, and excess. The accuracy of the analysis was comparable to or improved over commercial software with area calculation relative errors (RE) below 5% for simulated data with S/N = 5. File sets containing 1300 electropherograms were analyzed in 5 min, representing a nearly 200-fold reduction in analysis time from other methods. Incorporated within the program is a novel method for automated peak deconvolution using an Empirically Transformed Gaussian function. Area measurements of deconvoluted peaks were within 3% of the true value of a simulated data set with S/N = 5 and resolution (R(S)) = 1 for equivalent peaks, and within 10% when the ratio of the overlapped peak heights was 10:1.  相似文献   

18.
It is commonly accepted that the modern CE instruments equipped with efficient cooling system enable accurate determination of electrophoretic or electroosmotic mobilities. It is also often assumed that velocity of migration in a given buffer is constant throughout the capillary length. It is simultaneously neglected that the noncooled parts of capillary produce extensive Joule heating leading to an axial electric field distortion, which contributes to a difference between the effective and nominal electric field potentials and between velocities in the cooled and noncooled parts of capillary. This simplification introduces systematic errors, which so far were however not investigated experimentally. There was also no method proposed for their elimination. We show a simple and fast method allowing for estimation and elimination of these errors that is based on combination of a long‐end and short‐end injections. We use it to study the effects caused by variation of temperature, electric field, capillary length, and pH.  相似文献   

19.
When using capillary electrophoresis with a diode array detector, the wavelength at maximum absorbance is often chosen to quantify a given analyte. However, the background noise for every wavelength should be taken into account as it is by maximising the signal to noise ratio that the lowest limit of detection will be obtained. Here, we proposed an algorithm allowing to correct an electropherogram from its background absorption and to estimate the background noise. Applying it to all the electropherograms obtained in each wavelength channel allows obtaining the background noise as a function of the wavelength, which can be used to calculate the signal to noise ratio. This not only allows selecting the best wavelength to maximise the limit of detection of a given analyte, but also to generate a noise normalised base peak electropherogram (nn-BPE). It is shown that the noise normalised base peak electropherograms substantially improve the peaks visualisation. The algorithm is part of a graphic user interface that runs under MatLab environment; it does not require any programming knowledge and is freely available.  相似文献   

20.
DNA sequencing is performed in a multiplexed capillary electrophoresis system by UV absorption detection. Four individual electropherograms are obtained by simultaneously running the unlabeled DNA products of the four ddNTP-terminated reactions in the capillary array. The sequence of the template used in the cycle-sequencing reaction can be determined by overlaying the four electropherograms. Two internal standards are employed to adjust for the variance in migration times among the capillaries. After applying the correction algorithm, base calling can be done at a high level of confidence.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号