首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
We have developed a molecularly imprinted polymer (MIP) electrochemical sensor for entacapone (ETC) based on an electropolymerised polyphenylenediamine (Po-PD) on a glassy carbon electrode (GCE) surface. The direct electropolymerisation of the o-phenylenediamine monomer (o-PD) was carried out with ETC as a template. The steps of electropolymerization process, template removal and binding of the analyte were tested by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) using [Fe(CN)6]3−/[Fe(CN)6]4 − as a redox probe. The operation of the sensor has been investigated by differential pulse voltammetry (DPV). Under optimal experimental conditions, the response of the DPV was linearly proportional to the ETC concentration between 1.0×10−7 and 5.0×10−6 M ETC with a limit of detection (LOD) of 5.0×10−8 M. The developed sensor had excellent selectivity without detectable cross-reactivity for levodopa and carbidopa. The MIP sensor was successfully used to detect ETC in spiked human serum samples.  相似文献   

2.
《中国化学会会志》2018,65(6):743-749
A glassy carbon electrode (GCE) modified with a copper‐based metal‐organic framework (MOF) [HKUST‐1, HKUST‐1 = Cu3(BTC)2 (BTC = 1,3,5‐benzenetricarboxylicacid)] was developed as a highly sensitive and simple electrochemical sensor for the determination of dopamine (DA). The MOF was prepared by a hydrothermal process, and the morphology and crystal phase of the MOF were characterized by scanning electron microscopy (SEM) and X‐ray diffraction (XRD), respectively. Meanwhile, the electrochemical performance was investigated using cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). Under optimized conditions, the modified electrode showed excellent electrocatalytic activity and high selectivity toward DA. The linear response range was from 5.0 × 10−7 to 1.0 × 10−4 M and the detection limit was as low as 1.5 × 10−7 M. Moreover, the electrochemical sensor was used to detect DA in real samples with excellent results. MOF‐based sensors hold great promise for routine sensing applications in the field of electrochemical sensing.  相似文献   

3.
In this study, a molecularly imprinted electrochemical sensor (MIP/DA) was investigated for selective and sensitive determination of dopamine (DA) by electrochemical polymerization of p-aminothiophenol in the presence of DA on gold electrode. According to electrochemical behaviour of the sensor, gained through cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), MIP/DA sensor showed distinctive electron transfer characteristics in comparison to the non-imprinted (NIP/DA) sensor. Besides the MIP/DA sensor showed high selectivity for dopamine through its analyte specific cavities. The sensor had a broad working range of 5.0×10−8–2.0×10−7 M with a limit of detection (LOD) of 1.8×10−8 M and the developed sensor was successfully applied for determination of dopamine in pharmaceutical samples.  相似文献   

4.
A simpe electrochemical sensor for detection of cholic acid (CA) was designed by modifying phosphomolybdate (PMo12) doped polypyrrole (PPy) film on glassy carbon electrode (PMo12‐PPy/GCE). The electrochemical behavior of CA on PMo12‐PPy/GCE was investigated by cyclic voltammetry and 0.5 order differential voltammetry. The results indicated that CA had high inhibitory activity toward the peak currents of PMo12‐PPy/GCE. The reduction peak currents were linearly related to the logarithmic value of the concentration of CA from 1.0×10?7 to 1.0×10?3 mol/L with a low detection limit of 1.0×10?8 mol/L. The developed sensor exhibited excellent sensitivity, selectivity and stability for detection of CA, and it could be successfully applied to detect the level of CA in the urine samples. Moreover, the response mechanism of CA on the PMo12‐PPy/GCE was discussed in detail.  相似文献   

5.
An electrochemical sensor based on polyaniline-ZnO−NiO (PANI-ZnO−NiO) nanocomposite was developed for the non-enzymatic detection of malathion. The structure, surface morphology, and optical properties of the as-prepared nanocomposite were studied by XRD, FTIR, SEM, and UV-Vis spectroscopy. The electrochemical behavior of the nanocomposite based sensor was first evaluated through cyclic voltammetry (CV). Under optimum conditions, differential pulse voltammetry (DPV) was further utilized for malathion detection, which proved the PANI-ZnO−NiO/GCE electrode as an effective electrochemical sensor. The developed electrochemical sensor showed a low detection limit of 1.0×10−8 M with a wider linear range of 10 to 70 nM for malathion.  相似文献   

6.
《Electroanalysis》2017,29(11):2551-2558
The electrochemical oxidation of Sotalol (SOT) based on Tetrazolium Blue (TB)/gold nanoparticles (GNPs)‐modified carbon paste electrodes (CPE) have been studied in the presence of sodium lauryl sulphate (SLS). Cyclic voltammetry (CV), differential pulse voltammetry (DPV), chronoamperometry and electrochemical impedance spectroscopy (EIS) techniques have all been utilized within this study. GNPs and TB have a synergetic effect‐giving rise to highly improved electrochemical responses and provide an advantageous platform for the basis of an electrochemical sensor with excellent performance. The experimental parameters, electrodeposition time, pH and scan rate have all been examined and optimized. The sensing of SOT via DPV is found to exhibit a wide linear dynamic range of 1.0×10−7–7.5×10−4 M in pH 2. LOD and LOQ were calculated and found to correspond to 2.5×10−8 M and 8.3×10−8 M, respectively. The suggested sensor has been used successfully for SOT determination in pharmaceutical samples and human urine as real samples. Satisfactory recoveries of analyte from these samples are demonstrated indicating that the suggested sensor is highly suitable for clinical analysis, quality control and a routine determination of SOT in pharmaceutical formulations.  相似文献   

7.
《Analytical letters》2012,45(7):1132-1144
Molecular imprinting and sol-gel technique were combined to develop a molecular imprinted polymer (MIP) based electrochemical sensor in this work. With the successive modification of multi-walled carbon nanotubes (MWNTs) and gold nanoparticles (GNPs), a modified glassy carbon electrode (GCE) was immersed in a sol-gel solution in the presence of paracetamol (PR) for the electropolymerization to fabricate an imprinted sensor. Scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV) were employed to characterize the constructed sensor. The factors for the sensor preparation, the electropolymerization potential range, the monomer concentration, and the scan rate for the sensor preparation were optimized. The sensor displayed an excellent recognition capacity toward PR compared with other analogues. Additionally, the DPV peak current was linear to the PR concentration in the range from 8.0 × 10?8 to 5.0 × 10?5 mol/L, with a detection limit of 4.0 × 10?8 mol/L. The prepared sensor also showed satisfactory reproducibility and regeneration capacity.  相似文献   

8.
Simple, sensitive, accurate and inexpensive differential pulse (DPV) and square wave (SWV) voltammetric methods utilizing zeolite modified carbon paste electrode (ZMCPE) were developed for the determination of Oxymetazoline hydrochloride (OXM) in nasal drops. Various experimental parameters were optimized using cyclic voltammetry (CV). Calibration curves were linear over the concentration ranges 9.8×10−8–3.6×10−6 M and 9.8×10−6–9×10−5 M for DPV and SWV, respectively. The DPV method showed a limit of detection (LOD) of 1.04×10−7 M. The method was applied for the determination of OXM in pharmaceutical formulation with an average recovery of 101.18 % (%RSD=0.41, n=9).  相似文献   

9.
A carbon‐coated iron nanoparticles (CIN, a new style fullerence related nanomaterial) modified glassy carbon electrode (CIN/GCE) has been developed for the determination of uric acid (UA). Electrochemical behaviors of UA on CIN/GCE were explored by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). It was found that the voltammetric response of UA on CIN/GC was enhanced dramatically because of the strong accumulation effect of CIN and the large working area of the CIN/GC electrode. The parameters including the pH of supporting electrolyte, accumulation potential and time, that govern the analytical performance of UA have been studied and optimized. The DPV signal of UA on CIN/GCE increased linearly with its concentration in the range from 5.0×10?7 to 2.0×10?5 M, with a detection limit of 1.5×10?7 M (S/N=3). The CIN/GCE was used for the determination of UA in samples with satisfactory results. The proposed CIN/GCE electrochemical sensing platform holds great promise for simple, rapid, and accurate detection of UA.  相似文献   

10.
A multi-wall carbon nanotubes (MWNTs)-Nafion film-coated glassy carbon electrode (GCE) was fabricated and the electrochemical behavior of ofloxacin on the MWNTs-Nafion film-coated GCE were investigated by cyclic voltammetry (CV), linear sweep voltammetry (LSV) and electrochemical impedance spectroscopy (EIS). The oxidation peak current of ofloxacin increased significantly on the MWNTs-Nafion film modified GCE compared with that using a bare GCE. This nano-structured film electrode exhibited excellent enhancement effects on the electrochemical oxidation of ofloxacin. A well-defined oxidation peak attributed to ofloxacin was observed at 0.97 V and was applied to the determination of ofloxacin. The oxidation peak current was proportional to ofloxacin concentration in the ranges 1.0 × 10−8 to 1.0 × 10−6 mol/L and 1.0 × 10−6 to 2.0 × 10−5 mol/L. A detection limit of 8.0 × 10−9 mol/L was obtained for 400 s accumulation at open circuit (S/N = 3). This method for the detection of ofloxacin in human urine was satisfactory. __________ Translated from Chinese Journal of Applied Chemistry, 2007, 24(5): 540–545 [译自: 应用化学]  相似文献   

11.
在pH 3.00的B-R缓冲溶液中,采用差分脉冲伏安法(DPV)、线性扫描伏安法(LSV)和循环伏安法(CV)研究了甘草苷在玻碳电极上的电化学行为, 建立了测定甘草苷的DPV法。实验结果表明,甘草苷于1.16 V (vs.Ag/AgCl)处产生一个氧化峰,峰电流和甘草苷的浓度在2.00×10-6~3.50×10-5 mol/L范围内呈良好的线性关系,检出限为8.25×10-7 mol/L。该法用于实际样品甘草、胃康灵和逍遥丸中黄酮含量的测定(以甘草苷为对照品),平均回收率分别为97.1%、98.9%和102.0%。此外对电极反应机理作了初步探讨。  相似文献   

12.
《Electroanalysis》2017,29(2):506-513
A simple and highly sensitive sensor has been used for the determination of oxomemazine hydrochloride (OXO) in presence of paracetamol (PAR) and guaifenesin (GU). Carbon paste electrode was modified with multiwalled carbon nanotube (MWCNT), alizarine red S (AZ) and chitosan (CH). Scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to characterize the nanostructure and performance of the sensor. Under the optimized experimental conditions OXO gave linear response over the range of 2.00×10−6–1.00×10−4 mol L−1. The detection limit was found to be 4.35×10−7 mol L−1. The practical application of the modified electrode was demonstrated by measuring the concentration of OXO in pharmaceutical samples and urine. This revealed that suggested sensor shows excellent analytical performance for the determination of OXO in terms of a very low detection limit, high sensitivity and selectivity.  相似文献   

13.
《Analytical letters》2012,45(18):3046-3057
Abstract

Nano-MnO2/chitosan composite film modified glassy carbon electrode (MnO2/CHIT/GCE) was fabricated and a DNA probe was immobilized on the electrode surface. The immobilization and hybridization events of DNA were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The EIS was applied to the label-free detection of the target DNA. The human immunodeficiency virus (HIV) gene fragment was successfully detected by this DNA electrochemical sensor. The dynamic detection range was from 2.0 × 10?11 to 2.0 × 10?6 mol/L, with a detection limit of 1.0 × 10?12 mol/L.  相似文献   

14.
In this study, a novel and highly sensitive electrochemical method for simultaneous determination of catechol (CC) and hydroquinone (HQ) was developed, which worked at GCE modified with Nano cobalt (Nano-Co) by electrodeposition and L-Cysteine by electrochemical polymerization. The Nano-Co/L-Cysteine GCE was investigated by cyclic voltammetry (CV), SEM and EIS. The excellent conditions have been selected including supporting electrolyte, pH, accumulation time and scan rate. The calibration curves of were obtained that the linear regression equation was I=0.0734c+6×10−6 in the range of 5.8 μM to 103 μM (R2=0.9942) for CC and the linear regression equation was I=0.0566c+5×10−6 in the range of 5.8 μM to 100 μM (R2=0.9967) for HQ. The obtained detection limits of CC and HQ both were 6×10−7 M. The modified electrode was successfully applied to the simultaneous determination of CC and HQ in water samples.  相似文献   

15.
《Analytical letters》2012,45(14):2653-2663
Abstract

A multi‐walled carbon nanotubes modified glassy carbon electrode (MWNTs/GCE) was fabricated, and the electrochemical behaviors of acetaminophen (ACOP) were investigated on the MWNTs/GCE. The results showed that MWNTs exhibited excellent electrocatalytic effects on the reaction of ACOP by accelerating the electron transfer rate. Cyclic voltammetry (CV) was used to explore the electrochemical redox mechanism of ACOP on the MWNTs/GCE and differential pulse voltammetry (DPV) was taken to determine ACOP in samples, respectively. The results showed that the oxidative peak currents were linear with the concentration of ACOP in the range of 4.0×10?7–1.5×10?4 mol l?1 with the detection limit 1.2×10?7 mol l?1. The MWNTs/GCE showed satisfactory stability, selectivity, and it can be used to quantify ACOP in effervescent dosage real samples.  相似文献   

16.
Cu2O nanoparticles (nano-Cu2O) modified glassy carbon electrode (GCE) was fabricated and used to investigate the electrochemical behaviour of 4-nitrophenol (4-NP) by cyclic voltammetry (CV), chronoamperometry (CA), chronocoulometry (CC) and differential pulse voltammetry (DPV). Compared with GCE, a remarkable increase in oxidation peak current was observed. It indicates that nano-Cu2O exhibits remarkable enhancement effect on the electrochemical oxidation of 4-NP. Under the optimised experimental conditions, the oxidation peak currents were propotional to 4-NP concentration in the range from 1.0?×?10?6 to 4.0?×?10?4?mol?L?1 with a detection limit of 5.0?×?10?7?mol?L?1 (S/N?=?3). The fabricated electrode presented good repeatability, stability and anti-interference. Finally, the proposed method was applied to determine 4-NP in water samples. The recoveries for these samples were from 94.60% to 105.5%.  相似文献   

17.
A novel type of glassy carbon electrode modified with magnetic carbon-coated nickel nanoparticles (C-Ni/GCE) was fabricated and the electrochemical properties of brucine were studied using it. The carbon-coated nickel nanoparticles showed excellent electrocatalytic activity for the redox of brucine and an enhanced electron transfer rate. The electrochemical behavior of brucine on the C-Ni/GCE was explored by cyclic voltammetry (CV), and a redox mechanism for brucine was proposed. A series of electrochemical parameters were calculated for brucine by CV and controlled-potential electrolysis. The C-Ni/GCE showed good sensitivity, selectivity and stability, and was applied to determine the concentration of brucine. The differential pulse voltammetry (DPV) response of the C-Ni/GCE showed that the catalytic current was linear with the concentration of brucine in the range of 4.7 × 10−8 to 2.4 × 10−4 mol l−1, with a correlation coefficient of 0.998. The detection limit was 1.4 × 10−8 mol l−1.  相似文献   

18.
张亚会  徐慧  刘刚 《分析测试学报》2017,36(10):1208-1213
采用滴涂方式将羧酸化多壁碳纳米管(f-MWCNTs)修饰于玻碳电极(GCE)表面成膜,然后恒电位法在上述修饰电极表面电沉积壳聚糖(CS)膜,形成CS和f-MWCNTs复合膜修饰电极(CS/f-MWCNTs/GCE),并用于色氨酸(Trp)对映异构体的手性识别。采用扫描电子显微镜(SEM)表征了修饰电极表面形貌的差异,电化学阻抗(EIS)和循环伏安法(CV)研究修饰电极的电化学行为差异。差分脉冲伏安法(DPV)用于区别色氨酸(Trp)对映异构体,分离系数可达2.38。研究发现该修饰电极对L-Trp的DPV响应信号强于D-Trp,检测的线性范围为8.0×10~(-6)~4.0×10~(-3)mol/L,检出限(S/N=3)为5.0×10~(-6)mol/L。该方法简单、经济、快速,对发展其它手性化合物的检测方法提供了参考。  相似文献   

19.
《Electroanalysis》2017,29(4):1141-1146
A novel and sensitive voltammetric method was proposed for separation and determination of glutathione (GSH) and L‐tyrosine (Tyr) at acetylene black and chitosan modified glassy carbon electrode (AB‐CS/GCE). By introducing chlorogenic acid (CGA) as a new electrocatalytic mediator, GSH could be detected at much lower potential with symmetric peak shape. Acetylene black and chitosan composite served as current signal amplifier for sensitive detection. The electrochemical behavior of GSH and Tyr in the presence of CGA was studied at AB‐CS/GCE and complete separation of anodic peaks was achieved. Under the optimum conditions, the electrocatalytic oxidation peak current of GSH showed a linear dependence on its concentration in the ranges of 2.0×10−7‐4.0×10−5 M with the detection limit of 5.8×10−8 M (S/N=3), while the oxidation peak current of Tyr was linear to its concentration from 2.5×10−6 to 4.3×10−4 M with the detection limit of 9.2×10−7 M (S/N=3) by differential pulse voltammetry (DPV). The established method has been applied to the simultaneous determination of GSH and Tyr in human urine with satisfactory results.  相似文献   

20.
《Electroanalysis》2018,30(5):910-920
A label‐free DNA biosensor based on magnetite/multiwalled carbon nanotubes/chitosan (Fe3O4/MWCNTs‐COOH/CS) nanomaterial for detection of Bacillus cereus DNA sequences was fabricated. Negatively charged DNA was electrostatically adsorbed onto materials by protonation of positively charged chitosan under acidic conditions. The electrode surface and hybridization process were carried out by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). Under optimal conditions, the biosensor showed a good linear relationship between peak currents difference (ΔI) and logarithm of the target DNA concentration (Log C) ranging from 2.0×10−13 to 2.0×10−6 M with a detection limit of 2.0×10−15 M (signal/noise ratio of 3). The biosensor also revealed an excellent selectivity to three‐base, completely mismatched and completely matched DNA. This is a simple, fast and friendly method with a low detection limit for the detection of Bacillus cereus specific DNA compared with previously reported electrochemical DNA biosensor. Furthermore, the DNA biosensor may lead to the development of a technology for gold prospecting in the wild.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号