首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
A simple and novel flow‐injection chemiluminescence (FI‐CL) method was established for the determination of 2‐Methoxyestradiol (2‐ME) in pharmaceutical preparations and biological fluids. The method was based on the significant enhancement of the CL from the KMnO4‐Na2SO3 reaction by 2‐ME in acidic medium. Under optimized conditions, the CL intensity was correlated linearly with concentration of 2‐ME in the range of 5.0 × 10?8‐5.0 × 10?6 M (r = 0.9995). The detection limit (3σ) of 2‐ME was 7.5 × 10?9 M and the relative standard deviation was 0.8% at 5.0 × 10?7 M 2‐ME (n = 8). The proposed method was successfully applied for the flow‐injection CL determination of 2‐ME in pharmaceutical preparations and biological fluids with the recoveries from 92.4 to 106.8%. The possible CL reaction mechanism was also discussed briefly.  相似文献   

2.
A flow‐injection analysis chemiluminescence method based on the enhancement effect of the flumequine‐Tb(III) complex on the weak native emission of the Ce(IV)‐Na2SO3 system has been developed for the determination of flumequine. The method includes a cleanup and preconcentration stage (750‐fold) of the sample by hollow‐fiber liquid‐phase microextraction using an Accurel® Q 3/2 polypropylene hollow fiber impregnated with 1‐octanol as the supported liquid membrane. The obtained 50 μL acceptor phase was injected in a 1 mM Tb(III) + 4 mM Ce(IV) in 5% v/v H2SO4 stream and mixed with a 2 mM Na2SO3 stream before its introduction into the flow cell. The chemiluminescence signal was linear in the 0.3–15 ng/mL range, with detection and quantitation limits of 0.1 and 0.3 ng/mL, respectively. The method allows the selective extraction and determination of flumequine in wastewater samples, using simpler and lower‐cost instrumentation and with shorter extraction and analysis times than traditional high‐performance liquid chromatography analysis.  相似文献   

3.
An analytical method consisting of flow injection sampling and chemiluminescence detection for the determination of thyroxine hormone is described. It is based on the weak chemiluminescent reaction of KMnO4 ‐ Na2SO3 in acidic medium, which is enhanced by the addition of thyroxine hormone. The chemiluminescence intensity was correlated linearly with concentration of thyroxine in the range of 1.0 × 10?7 – 2.0 × 10?6 mol L?1 (r2 = 0.9976) with a relative standard deviation (n = 4) in the range of 1.0 – 1.9%. The limit of detection (3σ blank) is 5.0 × 10?9 mol L?1 with a sample throughput of 180 h?1. The method has been applied to the determination of thyroxine in pharmaceutical preparations and the results are in good agreement with the value reported. Metal and non‐metal ions and some organic compounds commonly present in tablets and some amino acids were also studied for thyroxine determination.  相似文献   

4.
A novel flow injection procedure has been developed for the determination of gallic acid based on the enhancement function for luminol‐AgNO3‐Ag NPs chemiluminescence (CL) system by gallic acid. The enhancement mechanism was proposed for the reinforcing effect of the gallic acid on the CL system. The UV‐vis absorption spectrum and CL emission spectrum were applied to confirm the mechanism. The method is simple, rapid and sensitive with a detection limit of 5×10?10 g·mL?1 and a linear range of 8.0×10?10–1.0×10?7 g·mL?1. The relative standard deviation (RSD) is 1.3% for eleven measurements of 5×10?8 g·mL?1 gallic acid. The method has been successfully applied to the determination of gallic acid in Chinese proprietary medicine–Jianmin Yanhou tablets and synthesized samples.  相似文献   

5.
A high‐performance chemiluminescence immunoassay, with long‐term durability, good precision and time‐saving, was proposed for the detection of free 17β‐estradiol (E2) in human serum. Ninety‐six microplates were coated with bovine serum albumin conjugated E2 antigen as solid phase for the immunoassay. The E2‐BSA antigen coated on the microplate and the E2 antigen in the sample competed for the binding sites on the horseradish peroxidase (HRP) labeled anti‐E2 antibody. Chemiluminescence reaction was subsequently carried out by HRP catalyzing luminol‐H2O2 substrates, and the chemiluminescence intensity was inversely proportional to the amount of analyte in human sera samples. The concentration of immunoreagents, immunoreaction time, and other relevant variable conditions upon the immunoassay were studied and optimized. The proposed method exhibited detection limit as low as 5.94×10?3 µg·L?1 in a linear detection range from 0.01 to 1.00 µg·L?1, good recoveries between 105% and 108%, and high precision with intra‐ and inter‐assay coefficients between 7.9% and 14.3%.  相似文献   

6.
A highly sensitive automated sequential‐injection chemiluminescence (SIA‐CL) method for determination of glucosamine sulphate (GLS) was developed. The goal of the present work is the evaluation of the enhancement effect of the investigated drug glucosamine sulphate on the chemiluminescence reaction between luminol and H2O2 in alkaline medium of 1.0 × 10?2 mol L?1 sodium hydroxide at pH 11. The experimental conditions affecting the CL reaction such as the sequence of the reagents, concentrations, flow rate and aspirated volumes of reactants were systematically investigated and optimized. Under optimum conditions 50 μL of 1.0 × 10?3 mol L?1 luminol, 30 μL of a GLS test solution and 50 μL of 1.0 × 10?2 mol L?1 H2O2 were used and the luminescing zone was pushed into the detector at a flow rate 100 μL s?1. The proposed method recorded high sensitivity, accuracy and simplicity that could be clarified as linear concentration range 1.0‐2000 ng mL?1 with rectilinear part (r = 0.9992, n = 9) and limit of detection 0.3 ng mL?1, along with relative standard deviation 1.3%. It was found that the developed method can be used directly to determine the investigated drug GLS in its pharmaceutical dosage forms and in spiked serum and urine by diluting the samples for a 1000 fold. The obtained results were statistically analyzed and compared with those obtained by the reported method.  相似文献   

7.
A poly(2‐aminophenylbenzimidazole)/gold nanoparticles (P2AB/AuNPs) coated disposable pencil graphite electrode (PGE) was fabricated as an enzyme‐free sensor for the H2O2 determination. P2AB/AuNPs and P2AB were successfully synthesized electrochemically on PGE in acetonitrile for the first time. The coatings were characterized by scanning electron microscopy, X‐ray diffraction spectroscopy, Energy‐dispersive X‐ray spectroscopy, Surface‐enhanced Raman spectroscopy, and UV‐Vis spectroscopy. AuNPs interacted with P2AB as carrier enhances the electrocatalytic activity towards reduction of H2O2. The analytical performance was evaluated in a 100 mM phosphate buffer solution at pH 6.5 by amperometry. The steady state current vs. H2O2 concentration is linear in the range of 0.06 to 100 mM (R2=0.992) with a limit of detection 3.67×10?5 M at ?0.8 V vs. SCE and no interference is caused by ascorbic acid, dopamine, uric acid, and glucose. The examination for the sensitive determination of H2O2 was conducted in commercially available hair oxidant solution. The results demonstrate that P2AB/AuNPs/PGE has potential applications as a sensing material for quantitative determination of H2O2.  相似文献   

8.
Updating the facile chemiluminescence oxygen‐aftereffect method, most suitable for determining the rate constant (kt) of the peroxy‐radical self‐reaction (main chemiluminescence channel), pertained to considering the sensitivity of such a method toward a disturbing influence of the peroxy radicals of the initiator of the chain oxidation process. Such a disturbance may derive from the side chemiluminescent reaction, which involves peroxy radicals of both hydrocarbon and initiator. To examine the applicability and limitations of the chemiluminescence method under present scrutiny, cyclohexene was used as the model oxidizable hydrocarbon substrate. Computer simulations of the reaction and chemiluminescence kinetics have demonstrated the validity of the considered methodology at the value of the rate constant of the propagation of the overall chain process by peroxy radicals of the initiator higher than 1 m ?1 s?1. Despite that the chemiluminescence time profile and the stationary level of the total chemiluminescence intensity depend on the kinetics of the side chemiluminescence channel and on the ratio of the excited‐state generation yields in the mentioned reaction channel and in the main chemiluminescence process, the value of kt assessed by the oxygen‐aftereffect method has been found independent of variation of these characteristics.  相似文献   

9.
A new, simple, rapid, sensitive, efficient and low‐cost spectrophotometric procedure for the determination of gold was developed. The method is based on the reaction of [AuCl4]? with 2‐[2‐(4‐dimethylaminophenyl)‐vinyl]‐1,3,3‐trimethyl‐3H‐indolium reagent to form a colored ion associate extractable by various organic solvents. The molar absorptivity of the ion associates is in the range (5.7–9.2) × 104 L mol?1 cm?1 depending on the extractant. Butyl acetate was chosen as the extractant. The optimum reaction conditions were established: pH 2–4, concentration of the dye reagent (0.8–1.5) × 10?4 mol L?1. The determination of gold is not hindered even by a 1000‐fold concentration of Ni and Co; a 500‐fold concentration of Pb and Zn; a 100‐fold concentration of Bi, Cu, Cd, Pt, Rh and Ru; or a 20‐fold concentration of Ag. The established method was applied to the determination of gold in model samples and enriched polymetallic ores.  相似文献   

10.
Based on the enhancing effects of norepinephrine (NE), epinephrine (EP), dopamine (DA) and 5‐hydroxytryptamine (5‐HT) on the chemiluminescence (CL) reaction between [Ag(HIO6)2]5? and luminol in alkaline solution, a high‐performance liquid chromatography (HPLC) method with CL detection was explored for the sensitive determination of monoamine neurotransmitters for the first time. The UV–visible absorption spectra were recorded to study the enhancement mechanism of monoamine neurotransmitters on the CL of [Ag(HIO6)2]5? and luminol reaction. The HPLC separation of NE, EP, DA and 5‐HT was achieved with isocratic elution using a mixture of aqueous 0.2% phosphoric acid and methanol (5:95, v/v) within 11.0 min. Under the optimized conditions, the detection limits of NE, EP, DA, and 5‐HT were 4.8, 0.9, 1.9 and 2.3 ng/mL, respectively, corresponding to 17.6–96.0 pg for 20 μL sample injection. The recoveries of monoamine neurotransmitters in rat brain were >95.6% with the precisions expressed by RSD <5.0%. The validated HPLC‐CL method was successfully applied for the quantification of NE, EP, DA and 5‐HT in rat brain. This method has promising potential for some biological and clinical investigations focusing on the levels of monoamine neurotransmitters. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
《Electroanalysis》2005,17(7):607-612
Based on the inhibition effect of dopamine and epinephrine on Ru(bpy) ‐tripropylamine electrogenerated chemiluminescence system, the excellent properties of carbon nanotube, and the cation permselectivity of Nafion film, an electrogenerated chemiluminescence inhibition method for determination of dopamine and epinephrine in the presence of ascorbic acid at carbon nanotube/Nafion‐Ru(bpy) composite film modified glassy carbon electrode was described. The results showed that the proposed method was sensitive and selective for the determination of dopamine and epinephine. The linear calibration range was from 1.6×10?9 M to 3.2×10?5 M and 5×10?8 M to 6×10?5 M for dopamine and epinephrine, respectively. 200‐fold excess of ascorbic acid did not interfere with the determination of 1 μM dopamine and epinephrine.  相似文献   

12.
A sensitive and reliable HPLC coupled with diode array detection and MS method was developed and validated for the first time to simultaneously identify and quantify eight characteristic 5,6,7,8‐tetrahydro‐2‐(2‐phenylethyl)chromones (THPECs) in Chinese eaglewood. Chromatographic separation was performed on a Zorbax SB C18 column with a gradient of acetonitrile/0.1% formic acid/water as the mobile phase. The MS fragmentation behavior of THPECs was characterized as the successive neutral loss of two molecules of H2O ([M+H–18–18]+) and then two molecules of CO ([M+H–18–18–28–28]+), which could be used to differentiate Chinese eaglewood from counterfeits. Validation of the developed analytical method showed good linearity, satisfactory precision, and good recovery. The established method was successfully applied to the simultaneous determination of eight THPECs in ten batches of Chinese eaglewood, which could be used as a tool for the quality control of Chinese eaglewood.  相似文献   

13.
顾文秀  夏文水 《中国化学》2006,24(10):1458-1461
A novel synthesis of the functional carbohydrate 2-amino-2-deoxy-D-gluconic acid was introduced and itscomplex formation with Cu(Ⅱ)was investigated to obtain the stability constant for its further applications to thefood and pharmaceutical industries.The equilibrium was investigated by spectrophotometric measurements andprocessed by dual-series linear regression method.Results:the yield of 2-amino-2-deoxy-D-gluconic acid is 70%.The complexation molar ratio is 1:2,the molar apsorptivity of the complex is 39.906 L·mol~(-1)·cm~(-1) at 630 nm,and the stability constant β_n is 6.24×10~5.  相似文献   

14.
A simple and fast flow method for the trace level determination of p‐toluidine, 2‐methyl‐5‐nitroaniline, and 2,4‐dinitroaniline in aqueous samples is reported. These amino/nitroaromatics are related to trinitrotoluene (TNT) and appear during the degradation process of the explosive. The chemical principles of ion‐pair formation and liquid‐liquid extraction are applied: In aqueous acidic medium, the protonated analyte [HA]+ makes an ion‐pair with the tetrachloroaurate(III) ion, followed by on‐line ion‐pair extraction into the dichloromethane carrier used. After membrane separation, the CH2Cl2 containing the ion‐pair, [HA]+[AuCl4], is mixed with the reversed micellar luminescent reagent of luminol (in 0.3 M Na2CO3) prepared from cetyl‐trimethylammonium chloride in CH2Cl2‐cyclohexane and the [AuCl4‐luminol chemiluminescence (CL) output is recorded. The detection limits (S/N> 3) are: p‐toluidine, 1.0 × 10−4M; 2‐methyl‐5‐nitroaniline, 1.0 × 10−7 M; 2,4‐dinitroaniline, 1.0 × 10−7 M, while the calibration curves are linear between 1.0 × 10−4 — 1.0 × 10−2 M for all the compounds. Although spectral studies indicated the formation and extraction of a very small amount of the ion‐pair species, the reversed micellar‐mediated CL detection system provides an alternative procedure for the determination of degradation products of the explosive TNT in environmental aqueous samples.  相似文献   

15.
An analytical procedure for the simultaneous determination in human urine of four thiophenethylamine designer drugs (2C‐T series) is reported. The quantitative analysis was performed by capillary electrophoresis with mass spectrometric detection (CE/MS), using 2,5‐dimethoxy‐4‐methylthiophenethylamine‐D4 (2C‐T‐D4) as internal standard. In order to minimize interferences with matrix components and to preconcentrate target analytes, solid‐phase extraction (SPE) was introduced in the method as a clean‐up step. The method was validated according to international guidelines. The data for accuracy and precision were within required limits. Calibration curves were generated over the range from 10 to 500 ng mL?1 and correlation coefficients always exceeded 0.997. The method was demonstrated to be specific, sensitive, and reliable for the analysis of these derivatives in urine samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
《Electroanalysis》2004,16(17):1401-1405
The immobilization of tris(2,2′‐bipyridyl)ruthenium(II), Ru(bpy)32+, at a glassy carbon electrode was achieved by entrapping the Ru(bpy)32+ in a vapor deposited titania sol‐gel membrane. The electrogenerated chemiluminescence (ECL) of the immobilized Ru(bpy)32+ was studied. The Ru(bpy)32+ modified electrode showed a fast ECL response to both oxalate and proline. The ECL intensity was linearly related to concentrations of oxalate and proline over the ranges from 20 to 700 μmol L?1 and 20 to 600 μmol L?1, respectively. The detection limits for oxalate and proline at 3σ were 5.0 μmol L?1 and 4.0 μmol L?1, respectively. This electrode possessed good precision and stability for oxalate and proline determinations. The electrogenerated chemiluminescence mechanism of proline system was discussed. This work provided a new way for the immobilization of Ru(bpy)32+ and the application of titania sol‐gel membrane in electrogenerated chemiluminescence.  相似文献   

17.
A highly sensitive reversed‐phase liquid chromatographic (HPLC) method was investigated to analyze a range of positron emission tomography (PET) radiopharmaceuticals using electrogenerated chemiluminescence (ECL) detection. ECL is based on the reaction of PET molecules with tris(2,2′‐bipyridyl)ruthenium(III) [Ru(bpy)33+], which is generated through the on‐line electro‐oxidation of Ru(bpy)32+. In 21 different radiopharmaceuticals studied, 18 compounds could be detected with detection limits (signal‐to‐noise ratio = 3) of 0.12–72 ng/mL per 20 μL injection. Sufficient reproducibility and linearity were obtained for the quantitative determination of PET molecules in pharmaceutical fluid. This method could be successfully applied to quality control tests of PET radiopharmaceuticals with ultra‐high specific radioactivity. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
2‐Ammonio‐5‐chloro‐4‐methylbenzenesulfonate, C7H8ClNO3S, (Ia), is an intermediate in the synthesis of lake red azo pigments. The present structure determination from single‐crystal data confirms the results of a previous powder diffraction determination [Bekö, Thoms, Brüning, Alig, van de Streek, Lakatos, Glaubitz & Schmidt (2010). Z. Kristallogr. 225 , 382–387]. The zwitterionic tautomeric form is confirmed. During a polymorph screening, two additional pseudopolymorphs were obtained, viz. 2‐ammonio‐5‐chloro‐4‐methylbenzenesulfonate 1‐methyl‐2‐pyrrolidone monosolvate, C7H8ClNO3S·C5H9NO, (Ib), and 2‐ammonio‐5‐chloro‐4‐methylbenzenesulfonate dimethyl sulfoxide monosolvate, C7H8ClNO3S·C2H6OS, (Ic). The molecules of (Ib) have crystallographic m symmetry. The 1‐methyl‐2‐pyrrolidone solvent molecule has an envelope conformation and is disordered around the mirror plane. The structure shows hydrogen‐bonded ladders of molecules [graph‐set notation C22(6)R22(12)] in the [010] direction. The benzene groups of adjacent ladders are also stacked in this direction. A different type of hydrogen‐bonded ladder [graph‐set notation C(6)R22(4)R44(12)] occurs in (Ic). In (Ia), (Ib) and (Ic), the molecules correspond to the zwitterionic tautomer. The structure of the cocrystal of 4‐aminobenzenesulfonic acid with 1,4‐bis(4,5‐dihydroimidazol‐2‐yl)benzene [Shang, Ren, Wang, Lu & Yang (2009). Acta Cryst. E 65 , o2221–o2222] is corrected; it actually contains 4‐aminobenzenesulfonate anions and 2,2′‐(1,4‐phenylene)di(dihydroimidazolium) dications, i.e. 2,2′‐(1,4‐phenylene)di(4,5‐dihydroimidazolium) bis(4‐aminobenzenesulfonate) dihydrate, C12H16N42+·2C6H6NO3S·2H2O. Hence, all known structures of aminobenzenesulfonic acid complexes contain ionic or zwitterionic molecules; there is no known structure with a neutral aminobenzenesulfonic acid molecule.  相似文献   

19.
The chemiluminescence behaviour and mechanism of peroxynitrous acid and Ru(bpy)32+ were studied in the presence of short-chain alcohols (methanol, ethanol, propan-1-ol, propan-2-ol, butanol, 2-methylpropan-1-ol, pentanol). It was found that the chemiluminescence intensity of peroxynitrous acid and Ru(bpy)32+ system could be significantly enhanced by these seven short-chain alcohols. The maximum chemiluminescence wavelength of 608 nm of [Ru(bpy)32+]* in the excited state was attributed to the reaction between Ru(bpy)32+ and dihydroxyalkyl radicals which were generated during the redox course of peroxynitrous acid and alcohols. In addition, the chemiluminescence signals of the system presented depended largely on the solubility and branched-chain structure as well as the length of carbon chain. The analytical characteristics and parameters of the peroxynitrous acid/Ru(bpy)32+/alcohols chemiluminescence system were investigated under optimum conditions.  相似文献   

20.
Crystals of 5‐chloropyridin‐2‐amine–(2E)‐but‐2‐enedioate (2/1), 2C5H5ClN2·C4H4O4, (I), and 2‐aminopyridinium dl ‐3‐carboxy‐2‐hydroxypropanoate, C5H7N2+·C4H5O5, (II), are built from the neutral 5‐chloropyridin‐2‐amine molecule and fumaric acid in the case of (I) and from ring‐N‐protonated 2‐aminopyridinium cations and malate anions in (II). The fumaric acid molecule lies on an inversion centre. In (I), the neutral 5‐chloropyridin‐2‐amine and fumaric acid molecules interact via hydrogen bonds, forming two‐dimensional layers parallel to the (100) plane, whereas in (II), oppositely charged units interact via ionic and hydrogen bonds, forming a three‐dimensional network.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号