首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The solvation parameter model is used to characterize the retention properties of five open-tubular column stationary phases (ZB-5 ms, DB-5 ms, DB-XLB, DB-17 ms, and DB-35 ms) based on silarylene-siloxane copolymer chemistries at five equally spaced temperatures over the range 60-140 degrees C. System constant differences and regression models for varied compounds are used to establish the selectivity equivalence of the silarylene-siloxane copolymer stationary phases and to compare their separation characteristics with poly(dimethyldiphenylsiloxane) stationary phases containing a nominally similar concentration of phenyl groups. These studies demonstrate that ZB-5 ms and DB-5 ms are selectivity equivalent. DB-XLB is significantly more dipolar and polarizable than DB-5 ms. In general terms, the silarylenesiloxane copolymer stationary phases are slightly less cohesive and more dipolar and polarizable with similar hydrogen-bond basicity to the poly(dimethyldiphenylsiloxane) stationary phases they were designed to replace. None of the silarylenesiloxane copolymer or poly(dimethyldiphenylsiloxane) stationary phases are hydrogen-bond acidic. Selectivity differences between the two types of stationary phase are temperature dependent and tend to be smaller at higher temperatures within the temperature range studied. Consequently, selectivity differences cannot be globalized without reference to the temperature for the comparison.  相似文献   

2.
3.
A crosslinkable biphenylmethylpolysiloxane stationary phase was synthesized for capillary column gas chromatography and compared with methyl, phenyl, and cyanopropyl polysiloxane stationary phases for the separation of isomeric polycyclic aromatic compounds. While the new phase gave similar separations of nonpolar isomers when compared to the nonpolar phases, separations of polar isomers were greatly improved because of the induced polarity of the biphenyl group of the stationary phase by the solute molecules. This polarizable stationary phase offers a unique selectivity which is not available in other stationary phases.  相似文献   

4.
The solvation parameter model is used to characterize the separation characteristics of two application-specific open-tubular columns (Rtx-Volatiles and Rtx-VGC) and a general purpose column for the separation of volatile organic compounds (DB-WAXetr) at five equally spaced temperatures over the range 60-140 degrees C. System constant differences and retention factor correlation plots are then used to determine selectivity differences between the above columns and their closest neighbors in a large database of system constants and retention factors for forty-four open-tubular columns. The Rtx-Volatiles column is shown to have separation characteristics predicted for a poly(dimethyldiphenylsiloxane) stationary phase containing about 16% diphenylsiloxane monomer. The Rtx-VGC column has separation properties similar to the poly(cyanopropylphenyldimethylsiloxane) stationary phase containing 14% cyanopropylphenylsiloxane monomer DB-1701 for non-polar and dipolar/polarizable compounds but significantly different characteristics for the separation of hydrogen-bond acids. For all practical purposes the DB-WAXetr column is shown to be selectivity equivalent to poly(ethylene glycol) columns prepared using different chemistries for bonding and immobilizing the stationary phase. Principal component analysis and cluster analysis are then used to classify the system constants for the above columns and a sub-database of eleven open-tubular columns (DB-1, HP-5, DB-VRX, Rtx-20, DB-35, Rtx-50, Rtx-65, DB-1301, DB-1701, DB-200, and DB-624) commonly used for the separation of volatile organic compounds. A rationale basis for column selection based on differences in intermolecular interactions is presented as an aid to method development for the separation of volatile organic compounds.  相似文献   

5.
建立了一种用于烟草样品中挥发性、半挥发性成分分析的液相色谱-毛细管气相色谱/质谱(LC-CGC/MS)离线联用方法。研究了LC-CGC/MS的分离机理。LC分析选用氨基分析柱(250 mm×2.0 mm, 5 μm)作为分析柱,正己烷-二氯甲烷-乙腈(90:6.6:3.4, v/v/v)作为流动相,对挥发性、半挥发性成分进行分离,收集得到5个馏分,并存放在5个氮吹瓶中。多次进样并收集相同时间段的馏分,氮吹浓缩至1 mL,然后分别进行CGC/MS分析,所用的CGC柱为DB-5MS(60 m×0.25 mm×0.25 μm)。结果显示,与直接采用CGC/MS分析相比,采用LC-CGC/MS分析复杂样本的效果更好,定性的可靠性更高。  相似文献   

6.
Hydrogen/deuterium isotope effects on hydrophobic binding were examined by means of reversed-phase chromatographic separation of protiated and deuterated isotopologue pairs for a set of 10 nonpolar and low-polarity compounds with 10 stationary phases having alkyl and aryl groups bonded to the silica surface. It was found that protiated compounds bind to nonpolar moieties attached to silica more strongly than deuterated ones, demonstrating that the CH/CD bonds of the solutes are weakened or have less restricted motions when bound in the stationary phase compared with the aqueous solvent (mobile phase). The interactions responsible for binding have been further characterized by studies of the effects of changes in mobile phase composition, temperature dependence of binding, and QSRR (quantitative structure-chromatographic retention relationship) analysis, demonstrating the importance of enthalpic effects in binding and differentiation between the isotopologues. To explain our results showing the active role of the hydrophobic (stationary) phase we propose a plausible model that includes specific contributions from aromatic edge-to-face attractive interactions and attractive interactions of aliphatic groups with the pi clouds of aromatic groups present as the solute or in the stationary phase.  相似文献   

7.
The aim of this work is to determine generic screening conditions and an initial simple separation strategy allowing the rapid separation of drug enantiomers in polar organic solvent chromatography (POSC). Four cellulose/amylose-based stationary phases were investigated in detail using two mobile phase basis solvents commonly applied in this mode, i.e. acetonitrile and methanol. Polar mode is interesting for use in purification of enantiomers. In a first step, the parameters potentially influencing the separation, such as addition of an alcohol to the polar organic solvent or the type of mobile phase additive(s), were examined by means of experimental designs. Afterwards, the factors found most important are investigated in more detail. Results showed that the cellulose- and amylose-based stationary phases have very broad and complementary enantiorecognition abilities in the POSC mode. The type of organic solvent for the mobile phase appeared to have a dramatic influence on the quality of the separation. Based on the results, a screening strategy was proposed. Enantioseparation was observed in more than 85% of the tested compounds and analysis times of last eluted peak were usually below 10 min.  相似文献   

8.
9.
This paper describes a strategy for the development of chromatographic methods for drug candidates based upon the use of simple MS compatible mobile phases and optimization of the chromatographic selectivity through variations of the stationary phase and mobile phase pH. The strategy employs an automated column selection system and a series of HPLC columns, varying in hydrophobicity and silanol activity, in combination with DryLab software to develop chromatographic methods for the separation of mixtures of bupivacaine and its metabolites; acidic, basic, and neutral compounds; and atenolol, nitrendipine, and their degradation products.  相似文献   

10.
In this study, the screening steps of chiral separation strategies with polysaccharide‐based chiral stationary phases were applied on boron cluster compounds in normal‐phase liquid chromatography (NPLC) and polar organic solvents chromatography (POSC). Since the screening steps were initially developed to analyze organic compounds, their applicability for boron clusters was investigated. Overall, the screening steps in NPLC were applicable for the separation of zwitterions, while for anions mostly no elution was observed. A hypothesis for the latter behavior is precipitation of anions in the nonpolar mobile phases. Ten out of 11 compounds could be partially or baseline separated on the NPLC screening systems. In POSC, all zwitterions were separated on at least one of the screening systems, with an overall lower retention as in NPLC. Anions were detected but not separated in the majority of the experiments. Also their retention on the chiral stationary phases was very limited. This study showed that the chiral discrimination potential of chemically modified polysaccharides is meaningful for chiral separations of structurally chiral boron cluster species, but needs further systematic research, in which recognition mechanisms should be further explored. In addition, some unusual peaks also indicated that conditions with a high separation efficiency must first be searched for some of the tested systems. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
Nano‐LC and CEC were coupled to MS through a nanospray or a pressurized liquid‐junction interface for the simultaneous separation and determination of 11 estrogenic compounds. Different stationary phases, that is, phenyl, C18, and C18 bidentate silica hydrate, were studied. For both techniques, the phenyl stationary phase was the best option, considering separation efficiency, selectivity, and resolution. Under the optimized conditions, the baseline separation of the target compounds (including estradiol and zearalanol epimers) was achieved in less than 20 min in nano‐LC‐MS and less than 13 min in CEC‐MS. Molecular imprinted polymer SPE was used for extracting the target compounds from mineral water samples with the analysis of nano‐LC‐MS. The whole molecular imprinted polymer SPE nano‐LC‐MS method was validated through a recovery study at two levels of concentration. Sensitivity was improved by on‐column focusing technique obtaining LODs in the range 1.4–55.4 ng/L.  相似文献   

12.
Coupling normal-phase LC separation methods to atmospheric pressure ionization (API)-mass spectrometry (MS) for detection can be problematic because of the possible detonation hazard and because nonpolar solvents do not support ionization of the analyte. Unlike achiral separations, enantiomeric separations can be very sensitive to small changes in the separation environment. Thus, completely substituting the main mobile phase component of a normal-phase LC solvent for an environmentally friendly, nonflammable fluorocarbon-ether as a safe and effective solvent must be thoroughly evaluated before it can be recommended for enantioselective separations with API-MS detection. Ethoxynonafluorobutane (ENFB) was used as a normal-phase solvent for the enantioselective separation of 15 compounds on two macrocyclic glycopeptide chiral stationary phases (CSPs) and a new polymeric chiral stationary phase. The chromatographic figures of merit were compared between results obtained with the ENFB mobile phases and traditional heptane-based mobile phases. In addition, the limits of detection (LOD) using the API-MS compatible ENFB were examined, as well as flow rate sensitivities and compatibilities with common polar organic modifier. ENFB is a safe and effective solvent for enantioselective normal-phase/API-MS analyses.  相似文献   

13.
The ability of different stationary phases developed for the analysis of polar compounds (ZIC-HILIC, ZIC-pHILIC and Zorbax SB-Aq) to separate isoniazid, its metabolites (acetylisonazid, pyridoxal isonicotinoyl hydrazone, pyridoxal isonicotinoyl hydrazone 5-phosphate), pyridoxine, pyridoxal and pyridoxal 5-phosphate under MS compatible conditions was systematically investigated using HPLC-UV. The mobile phase strength, pH and buffer concentration were modified to assess their impact on the retention of these compounds. The best available separation of the compounds was achieved using 1 mM ammonium formate (pH≈6) and ACN (20:80, v/v) on ZIC-HILIC and employing 5 mM ammonium formate (pH 3.0) and ACN (40:60, v/v) on ZIC-pHILIC. A gradient profile using 0.5 mM ammonium formate (pH≈6) and MeOH (0-12 min: 10% MeOH, 12-15 min: 10-50% MeOH, 15-35 min: 50% MeOH, 35.0-35.2 min: 50-10% MeOH, 35.2-45.0 min: 10% MeOH) provided the best separation of the compounds on Zorbax SB-Aq. Subsequent LC-MS analysis demonstrated that ZIC-HILIC is useful for the analysis of pyridoxine, pyridoxal and pyridoxal isonicotinoyl hydrazone. However, the chromatographic conditions developed for the analysis of the compounds on Zorbax SB-Aq are capable of achieving the best separation of all compounds in this study with the higher sensitivity for most of the analytes.  相似文献   

14.
Within the scope of research for target and non-target LC–MS/MS analysis of membrane degradation products of polymer electrolyte membrane fuel cells, a systematic method development for the separation of structurally similar compounds was performed by phase optimized liquid chromatography. Five different stationary phases with different selectivities were used. Isocratic separation for 4-hydroxybenzoic acid, isophthalic acid, terephthalic acid, 4-hydroxybenzaldehyde and 4-formylbenzoic acid was achieved on a C18 and a Phenyl phase. Using the PRISMA model the separation efficiency was optimized. This was achieved on a serially connected mixed stationary phase composed of 30 mm C18, 150 mm Phenyl and 60 mm C30. For the LC–MS screening of unknown degradation products from polymer electrolyte membranes in the product water of a fuel cell, a solvent gradient is mandatory for less polar or later eluting compounds. By means of 4-mercaptobenzoic acid it could be shown that a solvent gradient can be applied in order to elute later eluting compounds in a short time. The adaptability of this method for the qualitative analysis by target and non-target LC–MS/MS screening has been shown by means of 4-hydroxybenzoic acid. The combination of solvent gradient and isocratic conditions makes this approach attractive for the purpose of a screening method for known and unknown analytes in a water sample.  相似文献   

15.
It was demonstrated that the characteristics of stationary phases for reversed-phase chromatography can be compared by analyzing the retention of several compounds belonging to a homologous series during elution with one and the same composition of mobile phase or the retention of a nonpolar compound during elution with several mobile phases of different compositions. The slope of the corresponding linear correlations can be used to characterize the hydrophobicity of the columns (stationary phases) under study. To analyze the polar interactions between the sorbate and the stationary phase it is advantageous to study the retention of a polar substance in several (at least in two) mobile phases of different compositions. The degree of displacement of the linear correlation relative to that for nonpolar substances can be considered a measure of the influence of residual silanol groups on the total retention characteristics.  相似文献   

16.
李冬艳  吴锡  郝芳丽  杨洋  陈小明 《色谱》2016,34(1):80-84
采用超临界流体色谱法(SFC),在多糖固定相Chiralpak IA、IB、IC、ID、IE和IF上成功拆分了11种手性化合物。分离结果表明,这6支手性色谱柱对这些手性化合物具有良好的手性识别互补性,均可以在10 min之内得到良好的分离结果,具有较好的实用性。改性剂甲醇、乙醇和异丙醇对手性化合物的保留时间以及手性选择性均具有良好的调节作用,需要根据不同手性物质在手性柱上的分离情况加以区别,选择使用,并调节改性剂至合适的比例。针对键合型固定相溶剂通用性的特征,特殊改性剂的应用也有助于优化手性分离。  相似文献   

17.
The solvation parameter model is used to study the influence of temperature and composition on the selectivity of nine poly(siloxane) and two poly(ethylene glycol) stationary phase chemistries for open-tubular column gas chromatography. A database of system constants for the temperature range 60-140 degrees C was constructed from literature values with additional results determined for HP-50+, DB-210, DB-1701, DB-225 and SP-2340 columns. The general contribution of monomer composition (methyl, phenyl, cyanopropyl, and trifluoropropyl substituents) on the capacity of poly(siloxane) stationary phases for dispersion, electron lone pair, dipole-type and hydrogen-bond interactions is described. The selectivity coverage of the open-tubular column stationary phases is compared with a larger database for packed column stationary phases at a reference temperature of 120 degrees C. The open-tubular column stationary phases provide reasonable coverage of the range of dipole-type and hydrogen-bond base interactions for non-ionic packed column stationary phases. Deficiencies are noted in the coverage of electron lone pair interactions. None of the open-tubular column stationary phases are hydrogen-bond acids. The system constants are shown to change approximately linearly with temperature over the range 60-140 degrees C. The intercepts and slopes of these plots are used to discuss the influence of temperature on stationary phase selectivity.  相似文献   

18.
Gao L  Yu B  Yang H 《色谱》2011,29(11):1112-1117
应用高速逆流色谱法从母丁香和公丁香中快速分离了3种已知非挥发性化合物,并利用相同方法从公丁香中分离出2种色原酮类化合物。两相溶剂系统A为正己烷-乙酸乙酯-甲醇-水(5:8:6:13, v/v/v/v),系统B为正己烷-乙酸乙酯-甲醇-水(5:8:9:10, v/v/v/v),以系统A的上相为固定相,系统A和B的下相为流动相,利用梯度洗脱方式,在主机转速为880 r/min、流速1.2 mL/min条件下,成功地从70 mg母丁香粗提物中分离得到12.3 mg鞣花酸、9.6 mg鼠李素、17.2 mg槲皮素,从50 mg公丁香粗提物中分离得到5,7-二甲氧基-2-甲基色原酮10.2 mg、5,7-二甲氧基-2,6-二甲基色原酮8.6 mg,纯度均在96%以上。各化合物的结构均由质谱和核磁共振氢谱、碳谱鉴定。利用该方法可以对丁香不同药用部位中的非挥发性化合物进行有效的分离和纯化。  相似文献   

19.
Retention and separation of achiral compounds in supercritical fluid chromatography (SFC) depend on numerous parameters: some of these parameters are identical to those encountered in HPLC, such as the mobile phase polarity, while others are specific to SFC, as the density changes of the fluid, due to temperature and/or pressure variations. Additional effects are also related to the fluid compressibility, leading to unusual retention changes in SFC, for instance when flow rate or column length is varied. These additional effects can be minimised by working at lower temperatures in the subcritical domain, simplifying the understanding of retention behaviours. In these subcritical conditions, varied modifiers can be mixed to carbon dioxide, from hexane to methanol, allowing tuning the mobile phase polarity. With nonpolar modifiers, polar stationary phases are classically used. These chromatographic conditions are close to the ones of normal-phase LC. The addition of polar modifiers such as methanol or ACN increases the mobile phase polarity, allowing working with less polar stationary phases. In this case, despite the absence of water, retention behaviours generally follow the rules of RP LC. Moreover, because identical mobile phases can be used with all stationary phase types, from polar silica to nonpolar C18-bonded silica, the classical domains, RP and normal-phase, are easily brought together in SFC. A unified classification method based on the solvation parameter model is proposed to compare the stationary phase properties used with the same subcritical mobile phase.  相似文献   

20.
A stationary phase (named QA C10) with quaternary ammonium embedded between a propyl and a decyl chain was synthesized by immobilization of N,N‐dimethyldecylamine on chloropropyl–silica surface. A set of representative neutral, basic, and acidic compounds was employed to evaluate its chromatographic properties. The results illustrated that QA C10 was a mixed‐mode stationary phase possessing both hydrophobic and ionic characteristics. The QA C10 stationary phase was further used for selective separation of alkaloids from Cortex phellodendri. Under acidic condition, alkaloids could be eluted in first 8 min, while other neutral and acidic fractions were retained better on QA C10 column. Then, obtained alkaloid fraction was analyzed by LC‐MS/MS and 22 alkaloids were identified. Our study confirmed the advantages and application potential of the QA C10 stationary phase for alkaloids separation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号