首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
Prussian blue nanoparticles (PBNPs) were prepared by a self‐assembly process on a glassy carbon electrode (GCE) modified with poly(o‐phenylenediamine) (PoPD) film. The stepwise fabrication process of PBNP‐modified PoPD/GCE was characterized using scanning electron microscopy and electrochemical impedance spectroscopy. The prepared PBNPs showed an average size of 70 nm and a homogeneous distribution on the surface of the modified electrode. The PBNPs/PoPD/GCE showed electrocatalytic activity towards the oxidation of pyridoxine (PN) and was used as an amperometric sensor. The modified electrode exhibited a linear response for PN oxidation over the concentration range 3–38.5 μM with a detection limit of ca 6.10 × 10?7 M (S/N = 3) and sensitivity of 2.79936 × 103 mA M?1 cm?2 using an amperometric method. The mechanism and kinetics of the catalytic oxidation reaction of PN were investigated using cyclic voltammetry and chronoamperometry. The values of α, kcat and D were estimated as 0.36, 1.089 × 102 M?1 s?1 and 8.9 × 10?5 cm2 s?1, respectively. This sensor also exhibited good anti‐interference and selectivity. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

2.
A system of Pt nanoparticles and poly(ortho‐phenylenediamine) film electrochemically deposited onto a glassy carbon electrode (GCE/PoPD/Pt) was fabricated. Scanning electron microscopy, Fourier‐transform infrared spectroscopy, and atomic force microscopy techniques were used to identify the surface characteristics of the composite electrode. The conductive polymers and Pt nanoparticles together resulted in a synergistic effect, and the new formed surface was highly active against polyphenolic structures. Rosmarinic acid (RA) and protocatechuic acid (PCA) are phenolic compounds found in plants, and they are used in many applications, particularly as pharmaceuticals. The GCE/PoPD/Pt was used for the simultaneous determination of RA and PCA in a pH 2.0 H2SO4 solution for the first time. The RA and PCA concentrations were determined using differential pulse voltammetry (DPV) and chronoamperometry. By the amperometry measurement, for RA and PCA, a linear relation was observed in the concentration ranges of 1–55 μmol L?1 and 1–60 μmol L?1, with detection limits of 0.5 μmol L?1 and 0.6 μmol L?1, respectively. In the simultaneous determination with DPV, the detection limits for both RA and PCA were calculated as 0.7 μmol L?1. The GCE/PoPD/Pt was successfully used for the simultaneous determination of RA and PCA in a real sample, and its accuracy was verified by high‐performance liquid chromatography studies.  相似文献   

3.
Brilliant blue FCF‐modified glassy carbon electrodes have been prepared by cycling the Nafion (or poly(diallyldimethylammonium chloride) (PDDAC)) coated electrodes repeatedly 15 cycles in brilliant blue FCF (BB FCF) dye solution. The BB FCF molecules are incorporated into Nafion coating by cycling the film‐covered electrode between +0.3 to 1.2 V (vs. Ag/AgCl) in pH 1.5 BB FCF solution while PDDAC‐coated electrode cycled between 0 to ?1.0 V (vs. Ag/AgCl) in pH 6.5 BB FCF solution to immobilize the dye. Electrostatic interaction between dye molecule and PDDAC was predominant in PDDAC coating whereas immobilization of dye in Nafion film attributed to the combined effect of electrostatic and hydrophobic interactions. The voltammetric features of BB FCF‐modified electrodes resemble that of surface‐confined redox couples. The peak potentials of BB FCF‐incorporated PDDAC‐coated electrode were shifted to more positive potential region with decreasing pH of contacting solution. BB FCF‐modified electrodes showed electrocatalytic activity towards reduction of oxygen and oxidation of L ‐cysteine with significant decease of overvoltage compared to unmodified electrode. The BB FCF‐modified Nafion‐coated electrode was tested for its analytical applications toward determination of L ‐cysteine. The linear range of calibration plot at BB FCF‐modified Nafion‐coated electrode is 10 to 100 μM, which coincides with L ‐cysteine levels in biological fluids. Sensitivity and detection limit of the electrode are 111 nA μM?1 and 0.5 μM, respectively.  相似文献   

4.
《Electroanalysis》2004,16(4):289-297
The polymer film of N,N‐dimethylaniline (DMA) is deposited on the electrochemically pretreated glassy carbon (GC) electrode by continuous electrooxidation of the monomer. This poly N,N‐dimethylaniline (PDMA) film‐coated electrode can be used as an amperometric sensor of ascorbic acid (AA). The polymer film (thickness (?): 0.3±0.02 μm) having positive charge in its backbone attracts the anionic species AA. Thus, the anodic peak potential (350 mV vs. Ag|AgCl|NaCl(sat)) for the oxidation of AA at the bare electrode is largely shifted to the negative value (150 mV) at this electrode. The PDMA film‐coated electrode is stable in acidic, alkaline and neutral media and can sense AA at different pH's. The diffusion coefficients of AA in solution (D) and in film (Ds) were estimated by rotating disk electrode voltammetry: D=(5.5±0.1)×10?6 cm2 s?1 and Ds=(6.3±0.2)×10?8, (6.0±0.2)×10?8 and (4.7±0.2)×10?8 cm2 s?1 for 0.5, 1.5 and 3.0 mM AA, respectively. A permeability of AA through the PDMA film was found to decrease with increasing the concentration of AA in the solution. In the chronoamperometry, the current response for the oxidation of AA at different times elapsed after potential‐step application is linearly increased with the increase in AA concentration in a wide range of its concentration from 25 μM to 1.65 mM. In the hydrodynamic amperometry, a successive addition of 10 μM AA caused the successive increase in current response with equal amplitude and the sensitivity was calculated as 0.178 μA cm?2 μM?1. So, the fouling of the electrode surface caused by the oxidized product of AA is markedly eliminated at this PDMA film‐coated electrode. A flow injection analysis based on the present electrode was performed to estimate the concentration of vitamin C in fruit juice.  相似文献   

5.
A sensitive mercury‐free lead (Pb2+) sensor has been proposed based on an ordered mesoporous carbon and Nafion composite film (OMC/Nafion) coated glassy carbon electrode. The analysis of Pb2+ using anodic stripping voltammetry (ASV) includes two steps. Pb2+ ions are firstly reduced and deposited on the electrode surface in a Pb2+ solution (10 mL) during a preconcentration step biased at ?1.0 V, followed by a measurement step by differential pulse voltammetry (DPV) within the potential range of ?0.8 to ?0.3 V (scan rate: 20 mV/s, frequency: 20 Hz, amplitude: 50 mV, pulse width: 50 ms). Linear calibration curve was found to be from 20 nM to 2 μM for Pb2+ with a sensitivity of 17.4±1.38 μA/μM after a 5‐min of preconcentration. The detection limit was estimated to be around 4.60±0.12 nM at the signal to noise ratio of 3. Reproducibility (RSD%) was found to be 3.0% for a single sensor with eight measurements and 4.3% for five sensors prepared with identical procedures. The practical application of the proposed lead sensor was verified by determination of trace level of Pb2+ in tap water sample.  相似文献   

6.
《Electroanalysis》2004,16(11):904-909
A phthalocyanine based sensor, for anodic detection of sodium ethylene bisdithiocarbamate (Nabam) by coating a mixture of cobalt phthalocyanine (CoPC) modified carbon ink on the surface of a glassy carbon electrode, has been described. The modified ink was prepared by mixing three percent of cobalt phthalocyanine into carbon ink and then diluting the mixture with cyclohexanone in w/w ratio of 1/9. A suitable portion (or 1 μL) of ink mixture was then dip‐coated on a rotating disk glassy carbon electrode. The modified ink electrode was air‐dried for 15 mins before use. In comparison to the bare ink electrode on which the oxidation of Nabam takes place at 300 mV (vs. 3 M Ag/AgCl), the oxidation potential (?125 mV) of Nabam at the CoPC modified ink decreases significantly. A typical calibration plot of Nabam proportionally increases over the concentration range of 2.5 to 36 μM (R=0.9990). The detection limit is estimated about 28.8 nM (S/N=3) and its response time (between 10% to 90% of steady‐state response) is about 5.3 s at the injection of 5 μM Nabam. The sensitivity requirement of JMPR meeting (Joint FAO/WHO Meeting on Pesticide Residues) for ethylene bisdithiocarbamates (EBDCs) is achieved by this proposed scheme.  相似文献   

7.
A microelectrode array microprobe with a choline sensing site and an on‐probe reference electrode was constructed by depositing permselective polymer films and choline oxidase (ChOx) on one microelectrode, and iridium oxide (IrOx) on another, both of which were coated previously with a nanostructured Pt deposit. Scanning electron microscopy (SEM) of the nanostructured Pt layer revealed a unique pillar‐like, “nanograss” structure. Polyphenylenediamine (PPD) and Nafion were coated sequentially on the working (i. e. sensing) electrode surface to serve as the permselective polymer films. The microsensor exhibited high sensitivity to choline (123±13 μA mM?1 cm?2), low detection limit (3.2±0.8 μM), and fast response time (3–5 s). The choline sensor also was tested at physiological concentrations of electroactive interfering species common to brain extracellular fluid (i. e. ascorbic acid, dopamine, DOPA, and DOPAC) and showed excellent selectivity. Selectivity likely was aided by the relatively low potential of 0.35 V vs. IrOx that was made possible by the enhanced H2O2 electrooxidation activity of the underlying nanostructured Pt‐coated working electrode. Thus, Pt “nanograss” appears to be an excellent electrode surface modification for creation of high performance electroenzymatic biosensors.  相似文献   

8.
《Electroanalysis》2017,29(10):2300-2306
High‐performance biosensors were fabricated by efficiently transferring enzyme onto Pt electrode surfaces using a polydimethylsiloxane (PDMS) stamp. Polypyrrole and Nafion were coated first on the electrode surface to act as permselective films for exclusion of both anionic and cationic electrooxidizable interfering compounds. A chitosan film then was electrochemically deposited to serve as an adhesive layer for enzyme immobilization. Glucose oxidase (GOx) was selected as a model enzyme for construction of a glucose biosensor, and a mixture of GOx and bovine serum albumin was stamped onto the chitosan‐coated surface and subsequently crosslinked using glutaraldehyde vapor. For the optimized fabrication process, the biosensor exhibited excellent performance characteristics including a linear range up to 2 mM with sensitivity of 29.4±1.3 μA mM−1 cm−2 and detection limit of 4.3±1.7 μM (S/N=3) as well as a rapid response time of ∼2 s. In comparison to those previously described, this glucose biosensor exhibits an excellent combination of high sensitivity, low detection limit, rapid response time, and good selectivity. Thus, these results support the use of PDMS stamping as an effective enzyme deposition method for electroenzymatic biosensor fabrication, which may prove especially useful for the deposition of enzyme at selected sites on microelectrode array microprobes of the kind used for neuroscience research in vivo .  相似文献   

9.
Single‐walled carbon nanotubes(SWCNTs) were dispersed into DMSO, and a SWCNTs‐film coated glassy carbon electrode was achieved via evaporating the solvent. The results indicated that CNT modified glassy carbon electrode exhibited efficiently electrocatalytic reduction for ranitidine and metronidazole with relatively high sensitivity, stability and life time. Under conditions of cyclic voltammetry, the potential for reduction of selected analytes is lowered by approximately 150 mV and current is enhanced significantly (7 times) in comparison to the bare glassy carbon electrode. The electrocatalytic behavior is further exploited as a sensitive detection scheme for these analytes determinations by hydrodynamic amperometry. Under optimized condition in amperometric method the concentration calibration range, detection limit and sensitivity were about, 0.1–200 μM, detection limit (S/N=3) 6.3×10?8 mol L?1 and sensitivity 40 nA/μM for metronidazole and 0.3–270 μM 7.73×10?8 mol L?1 and 25 nA/μM for ranitidine. In addition, the ability of the modified electrode for simultaneous determination of ranitidine and metronidazole was evaluated. The proposed method was successfully applied to ranitidine and metronidazole determination in tablets. The analytical performance of this sensor has been evaluated for detection of these analytes in serum as a real sample.  相似文献   

10.
《Electroanalysis》2017,29(11):2572-2578
We report in this work, a new method for the determination of captopril by differential pulse voltammetry using a glassy carbon electrode modified with a copper metal‐organic framework (H‐Kust‐1 or Cu3(BTC)2 or Cu‐BTC), immobilized on the surface by a copolymer of acrylamide and sodium acrylate. This compound is detected by the formation of a copper(II)‐captopril complex that is observed in an oxidation potential at ca. +0.28 V vs . Ag/AgCl. A linear dynamic range is obtained for a captopril concentration of 0.5 μM to 7.0 μM and the voltammetric response is highly reproducible within 3.52 % error. The sensitivity of 9.71±0.37 nA μM−1 and the limit of detection of 0.20±0.01 μM make this methodology highly applicable for practical applications. The determination of captopril in a commercial pharmaceutical sample showed a recovery of 93.3 %.  相似文献   

11.
《Electroanalysis》2006,18(1):64-69
Efficient and stable electrocatalytic activity for the reduction of O2 at activated screen‐printed carbon electrodes modified with palladium nanoparticles (SPE*‐Pd) was demonstrated in this study. X‐ray photoelectron spectroscopy confirmed the formation of >C?O functional group on electrode surface during the preanodization procedure at 2.0 V (vs. Ag/AgCl). The existence of chloride moieties was also identified possibly from the organic binder of carbon ink used in SPE fabrication. Both >C?O and chloride functional groups were essential for the excellent stability of the SPE*‐Pd. Electrochemical impedance spectroscopy verified the enhanced kinetic rate of oxygen reduction reaction at the as‐prepared Pd nanoparticles. The SPE*‐Pd showed ca. 250 mV positive shift in peak potential together with twice increase in peak current compared to those observed at a SPE‐Pt. The calibration plot was linear up to 8 ppm of DO with sensitivity and regression coefficient of 4.49 μA/ppm and 0.9936, respectively. The variation coefficient of ipc for 7 DO determinations with O2‐saturated pH 7.4 PBS was 2.1%. Real sample assays for ground and tap waters gave consistent values to those measured by a commercial dissolved oxygen meter.  相似文献   

12.
《Electroanalysis》2018,30(3):561-570
Complete all‐in‐one multi‐arrayed glutamate (Glut) sensors have been constructed on a silicon‐based micromachined probe composed of micro‐platinum (Pt) working electrodes, a micro‐silver/silver chloride (Ag/AgCl) reference electrode (RE), and a micro‐Pt counter electrode (CE). The OCP shift of the electrodeposited Ag/AgCl on‐probe micro‐reference electrode compared with a Ag/AgCl wire is <0.1 mV/h. The composition ratio of Ag, Cl, and Pt on the electrodeposited on‐probe micro‐reference electrode is observed to be 1.00 : 0.48 : 0.02 analyzed by EDS. The miniaturized amperometric Glut biosensors were constructed on working electrode sites (electrode area: ∼8.5×10−5 cm2) of the microprobe modified with glutamate oxidase (GlutOx) enzyme layers for the selective, fast, and continuous detection of L‐glutamate. The sensor selectivity towards common electroactive interferents has been improved significantly by coating the electrode surface with perm‐selective polymer layers, overoxidized polypyrrole (PPY) and Nafion®. The sensitivity, detection range, and response time of the proposed all‐in‐one Glut biosensors are 204.7±5.8 nA μM−1 cm−2 (N=5), 4.99–109 μM, and 2.7±0.3 sec, respectively and no interferent signals of AA and DA were observed. The sensor can be reused over 19 times of continuous repetitive operation (total measurement time: ∼4 hours) and the sensor sensitivity can retain up to four weeks of storage.  相似文献   

13.
A glassy carbon electrode has been coated by electrodeposition with a thin film of cobalt based layered double hydroxide (LDH) and used as a pH sensor. The developed electrode displays a linear super‐Nernstian response (?76.2±0.6 mV/pH) in the pH range between 2 and 14 and it is particularly suitable to operate in strongly alkaline solution. The reproducibility of the sensor construction is good with a relative standard deviation of the calibration curve slopes of±2.5 % (n=4). The electrode has a response time comparable to that exhibited by commercial glass electrodes in the pH range examined and is not affected by interference from the most common anions and cations.  相似文献   

14.
A gold electrode modified by a thin film of cationic kaolinite was used for the electrochemical detection of iodide in aqueous solution in the presence of thiosulfate. At gold electrode, iodide showed two electrochemical systems in the potential range explored (0.10 V to 0.85 V). The pH‐independent system was assigned to the redox couple I2/I? and the pH‐dependent one assigned to the redox couple HIO/ . For increased amount of thiosulfate the oxidation peak intensity of the first system increases sharply followed by the gradual decrease of the reduction peak, due to the chemical reaction between thiosulfate and oxidized iodide. The calibration curve in the presence of excess thiosulfate resulted in an increase of the sensitivity by a factor of 7. To improve this sensitivity, the bare gold electrode was coated by a thin film of an anionic exchanger kaolinite, obtained by grafting the ionic liquid (1‐(2‐hydroxyethyl)‐4‐(tert‐butyl) pyridinium chloride). Accumulation‐detection method yielded a spectacular increase of the oxidation peak current of iodide in the presence of thiosulfate ions. At optimized experimental conditions, a sensitivity of 2.45 μA.μM?1 and a detection limit of 65 nM were obtained. The method was successfully applied for total iodine determination in povidone?iodine formulation.  相似文献   

15.
Single‐wall carbon nanotubes (SWCNTs) were used as an immobilization matrix to incorporate [Ir(ppy)2(phen‐dione)](PF6) complex onto a glassy carbon electrode for the study of electrocatalytic reduction of periodate ion. Detailed preliminary electrochemical data for the Ir(III)‐complex in acetonitrile solution and for the modified GCE/SWCNTs/[Ir(ppy)2(phen‐dione)](PF6)/CGE are presented. The modified electrode was applied to selective amperometric detection of periodate through its electrocatalytic reduction to iodide at 0.200 V and pH 2.0. The use of amperometry resulted in two calibration plots over the concentration ranges of 1‐20 μM and 20‐450 μM, with a detection limit of 0.6 μM and sensitivity of 198 nA μM?1.  相似文献   

16.
The performance of an enzyme sensor fabricated through covalent bond formation on the HRP‐bonded poly(1,8‐diaminonaphthalene) (polyDAN) layer with gold nanoparticles (AuNPs) was applied to catalyze the electrochemical reduction of H2O2. The surface characteristics of the sensor probe were studied using cyclic voltammetry, SEM, XPS, QCM, and impedance spectroscopy. The AuNP‐deposited surface resulted in higher conductivity and sensitivity for H2O2 detection in phosphate buffer solution. A linear calibration plot was obtained in the H2O2 concentration range between 10.0 μM and 25.0 mM with detection limit 5.0±1.25 μM. The lifetime of HRP/polyDAN/AuNP/GC probe was over 70 days without response loss.  相似文献   

17.
《Electroanalysis》2018,30(1):154-161
Trace amount of arsenate in the presence of arsenite was determined directly on pencil graphite electrode modified by graphene oxide and zirconium (Zr−G−PGE). The layer‐by‐layer modification of PGE was characterized by scanning electron microscopy (SEM), X‐ray photoelectron spectroscopy (XPS) and cyclic voltammetry (CV). Key point of the developed method was quick adsorption of arsenate than arsenite on the Zr−G−PGE. In optimal conditions, the Zr−G−PGE was applied for determination of arsenate using differential pulse voltammetry in a linear range 0.10–40.0 μg L−1 with a limit of determination of 0.12±0.01 μg L−1. The sensitivity of the electrode was 1.36±0.07 μA/μg L−1. The modified electrode was used to measure the concentration of arsenate in the river water. A recovery test was performed by introducing 10 μg L−1 arsenate into the rivers water in order and acceptable data of average recovery of 101.2 % was obtained. From the experimental results, the as‐prepared electrode can provide a satisfactory method for direct determination of arsenate in real samples.  相似文献   

18.
《Electroanalysis》2005,17(24):2231-2238
Square‐wave voltammetric detection of dopamine was studied at a copper (Cu)‐(3‐mercaptopropyl) trimethoxy silane (MPS)‐complex modified electrode (Cu‐MPS). The modification of the electrode was based on the attachment of MPS onto an electrochemically activated glassy carbon electrode (GCE) by the interaction between methoxy silane groups of MPS and surface hydroxyl groups and followed by the complexation of copper with the thiol groups of MPS. The surface of the modified electrode was further coated by a thin layer of Nafion film. The surface of the Nafion coated MPS‐Cu complex modified electrode (Nafion/Cu‐MPS) was characterized using cyclic voltammetry, electrochemical quartz crystal microbalance (EQCM), scanning electron microscope (SEM), X‐ray photoelectron spectroscopy (XPS), and Fourier transform infrared (FT‐IR) spectrometry. The modified electrode exhibited an excellent electrocatalytic activity towards the oxidation of dopamine, which was oxidized at a reduced potential of +0.35 V (vs. Ag/AgCl) at a wider pH range. Various experimental parameters, such as the amount of copper, the pH, and the temperature were optimized. A linear calibration plot was obtained in the concentration range between 8.0×10?8 M and 5.0×10?6 M and the detection limit was determined to be 5.0×10?8 M. The other common biological compounds including ascorbic acid did not interfere and the modified electrode showed an excellent specificity to the detection of dopamine. The Nafion/Cu‐MPS modified electrode can be used for about 2 months without any significant loss in sensitivity.  相似文献   

19.
We report a simple approach to the production of carbon fiber‐based amperometric microbiosensors for selective detection of hydrogen peroxide (H2O2), which was achieved by electrometallization of carbon fiber microelectrodes (CFMs) by electrodeposition of Pt nanoparticles. The Pt‐carbon hybrid sensing interface provided a sensitivity of 7711±587 μA ? mM?1 ? cm?2, a detection limit of 0.53±0.16 μM (S/N=3), a linear range of 0.8 μM–8.6 mM, and a response time of <2 sec. The morphologies of the Pt nanoparticle‐modified CFMs were characterized by scanning electron microscopy. To achieve selectivity, permseletive layers, polyphenylenediamine (PPD) and Nafion, were deposited resulting in exclusion of the anionic and cationic interferents, ascorbic acid and dopamine, respectively, at their physiologically relevant concentrations. The resultant sensors displayed a sensitivity to hydrogen peroxide of 1381±72 μA ? mM?1 ? cm?2, and a detection limit of 0.86±0.19 μM (S/N=3). This simple and rapid metallization method converts carbon fiber microelectrodes, which are readily accessible, to microscale Pt electrodes in 2 min, providing a platform for oxidase‐based amperometric biosensors with improved spatial resolution over more commonly used platinum electrode array microprobes.  相似文献   

20.
Aluminum chlorohydrate (Al2(OH)5Cl?2H2O, ACH) is an active ingredient in many antiperspirants and deodorants formulation to reduce the body odors (mainly sweat) through interaction with apocrine sweat glands to produce insoluble aluminum hydroxide and free chloride, which then plugs the sweat gland that stops the flow of sweat to the skin's surface. We demonstrated here an one drop (50 μL) electrochemical sensing of the ACH using an in‐built three screen‐printed electrodes assembly containing Ag as working and pseudo reference and carbon as counter electrode system (AgSPE). The free Cl? ion librated from ACH/H2O reaction was detected at AgSPE surface at 0.072 V vs. pseudo Ag reference electrode system in pH 2 phosphate solution by Cyclic voltammetric Technique. Under optimal working condition the AgSPE shows a linear calibration plot in the window of 30–2000 ppm of ACH with sensitivity and regression values of 0.104 μA/ppm and 0.998 respectively. Calculated detection limit is 3.03 ppm. RSD values of intra‐ and interassays were 0.19% and 2.79% respectively. Finally, real sample (antiperspirant deodorant lotions) assays were successfully demonstrated with results comparable to the predicted values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏