首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The feasibility of microwave-accelerated derivatization for capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection was evaluated. The derivatization reaction was performed in a domestic microwave oven. Histidine (His), 1-methylhistidine (1-MH) and 3-methylhistidine (3-MH) were selected as test analytes and fluorescein isothiocyanate (FITC) was chosen as a fluorescent derivatizing reagent. Parameters that may affect the derivatization reaction and/or subsequent CE separation were systematically investigated. Under optimized conditions, the microwave-accelerated derivatization reaction was successfully completed within 150 s, compared to 4-24 h in a conventional water-bath derivatization process. This will remarkably reduce the overall analysis time and increase sample throughput of CE-LIF. The detection limits of this method were found to be 0.023 ng/mL for His, 0.023 ng/mL for 1-MH, and 0.034 ng/mL for 3-MH, respectively, comparable to those obtained using traditional derivatization protocols. The proposed method was characterized in terms of precision, linearity, accuracy and successfully applied for rapid and sensitive determination of these analytes in human urine.  相似文献   

2.
LIF detection is one of the most sensitive detection methods for CE. However, its application is limited because the analyte is usually required to be derivatized with a fluorescent label. As a result, LIF is seldom used to analyze active ingredients in plants. In this work, we introduce a rapid, simple, and sensitive method of nonaqueous CE (NACE) coupled with laser-induced native fluorescence detection for the simultaneous analysis of berberine, palmatine, and jatrorrhizine. This method skillfully utilizes the native fluorescence of these alkaloids and requires no troublesome fluorescent derivatization. As these alkaloids can fluoresce to some degree, they were simply detected by a commercially available 488 nm Ar+ laser. The native fluorescence of the analytes was greatly enhanced by nonaqueous media. Compared with the reported UV detection method, much lower LOD was achieved (6.0 ng/mL for berberine, 7.5 ng/mL for palmatine, and 380 ng/mL for jatrorrhizine). This method was successfully applied to analyze berberine, palmatine, and jatrorrhizine in two Chinese herbal medicines, Rhizoma coptidis and Caulis mahoniae.  相似文献   

3.
Bubble cells have been frequently employed in capillary electrophoresis (CE) to increase the light path length with UV detection to provide an increase in the observed sensitivity of CE; however this approach has not been commonly used for laser-induced fluorescence detection (LIF) with CE. In this paper we study the influence of laser power on the sensitivity of detection in using conventional and enlarged fused silica capillaries for CE with LIF. When using the bubble cell capillary, the laser power must be decreased relative to use of the conventional capillary to reduce the effects of photodegradation of the species being illuminated by the laser. Even though the light intensity was decreased, an increase in sensitivity of detection was observed for most compounds when a bubble cell was used. This increase ranged from a factor of 8 for riboflavin (410 nm excitation) to 3.2 for most aromatic compounds (266 nm excitation), when using a 3x bubble cell compared with a conventional capillary. The bubble cell capillary was used for native detection of IgG by LIF at 266 nm. A limit of detection of 60 ng mL(-1) was obtained from a 20 pg injection, which was 40 times more sensitive than silver staining in conventional SDS/PAGE.  相似文献   

4.
A method was developed for the determination of phosphoamino acids by capillary zone electrophoresis-laser-induced fluorescence detection (argon ion laser, excitation at 488 nm and emission at 520 nm) using derivatization with N-hydroxysuccinimidyl fluorescein-O-acetate (SIFA). Different variables affecting the derivatization (SIFA concentration, derivatization pH, reaction temperature and reaction time) and the separation (type, pH and concentration of buffer, applied voltage and injection mode) were investigated in detail. The optimized separation conditions were 40 mM boric acid buffer (pH 9.2) for background electrolyte, 25 kV for the separation voltage, 25 degrees C for the capillary temperature and 5 s at 0.5 psi for the sample injection. Under the optimal conditions, the SIFA-labeled phosphoamino acids were fully separated within 7 min. The detection limits ranged from 0.1 to 0.3 nM, which are the lowest values reported for capillary electrophoresis (CE) methods. The proposed methodology allowed the rapid, sensitive and selective determination of phosphoamino acids in hen egg yolk phosvitin by the standard addition method. The recovery of these compounds in real sample was 94.0-103.5%. The developed method surpasses previously published CE methods in terms of detection limit, separation time, stability and simplicity of the electrophoretic procedure.  相似文献   

5.
Five 2C-series of phenethylamine designer drugs, including 2,5-dimethoxy-4-ethylthio-phenethylamine (2C-T-2), 2,5-dimethoxy-4-(n)-propylthiophenethylamine (2C-T-7), 4-chloro-2,5-dimethoxyphenethylamine (2C-C), 4-bromo-2,5-dimethoxy-phenethylamine (2C-B), 2,5-dimethoxy-4-iodo-phenethylamine (2C-I), were synthesized and standard GC/MS and fluorescence spectra are reported for them. A mixture of the five drugs was separated and detected by means of capillary electrophoresis (CE) with native fluorescence and light emitting diode (LED)-induced fluorescence (LIF) detection, respectively, for comparison. In the former case, exciting at a wavelength of 300 nm from a Xe lamp was used. The detection limits were found to be only in the range of approximately 10(-4) M by the micellar electrokinetic chromatography (MEKC) mode but were improved to approximately 10(-7) M when the sweeping-MEKC mode was used. For a highly sensitive analysis, LED-induced fluorescence detection was examined by derivatizing the compounds with a fluorescent dye, fluorescein isothiocyanate isomer I (FITC). A blue-LED (approximately 2 mW) was used as the fluorescence excitation source. The detection limits were improved to approximately 10(-7) and approximately 10(-8) M, respectively, when the MEKC and stacking-MEKC modes were applied. A mimic urine sample was obtained by spiking urine from a volunteer with the five standards, and after liquid-liquid extraction, the sample was examined by means of the MEKC-LIF mode. The extraction procedures used for the urine sample and the CE conditions for the separation were optimized.  相似文献   

6.
In this work, a sub-minute and sensitive capillary electrophoresis with laser-induced fluorescence (CE-LIF) method was developed for the analysis and quantitation of the neurotransmitter 5-hydroxytryptamine (5-HT) or serotonin in urine. The method involves precolumn derivatization with fluorescein isothiocyanate isomer I (FITC) using an excitation light from an argon ion laser of 488 nm and a 520 nm band pass emission filter. Different variables that affect derivatization (pH, FITC concentration, reaction time and temperature) and separation (buffer concentration, pH, applied voltage and injection time) were studied. The linear dynamic range obtained was between 0 and 188 nM with a detection limit of 16 nm with a RSD between 2 and 9%. The applicability of the proposed method was demonstrated by analysis of 5-HT in human urine, establishing a concentration of 57 nM in control urine. The method was validated by standard-addition methodology.  相似文献   

7.
An LIF detector was integrated into a CE system which uses a ball lens to focus the laser beam on the CE capillary. The detector employs an ellipsoid that is glued on the capillary window, to permit the collection of the fluorescence in the capillary. This 'trapped' fluorescence stays in the capillary because the angle of the silica/air interface is greater than the critical angle. The performance of this new detector setup is found to be identical to the collinear setup using the same ball lens. An application to the analysis of FITC-labeled IgG was optimized using a 14 cm effective length capillary. The LOD of an FITC-labeled IgG2 at an excitation wavelength of 488 nm was 150 pg/mL, which was 10 times better than the LOD recorded with slab gel silver staining. Using a tetramethylrhodamine (TAMRA)-labeled IgG2 and a 532 nm excitation wavelength the LOD is 50 pg/mL. The electropherograms of four different commercial FITC conjugates of IgG were studied. The presence of aggregates was observed in two samples while close kinetics of reduction was observed between free aggregates and high aggregates concentration samples. The integrated LIF detector provides an extremely powerful and convenient tool for antibody analysis and should be useful for therapeutic MAb control in pharmaceutical facilities.  相似文献   

8.
Liu Q  Liu Y  Guo M  Luo X  Yao S 《Talanta》2006,70(1):202-207
Laser-induced fluorescence (LIF) is a highly sensitive detection method for capillary electrophoresis (CE). However, it usually requires analyte to be derivatized, unless the wavelength of native fluorescence of analyte matches the laser's. That limits its application in drug analysis. In this work, we introduced a rapid, simple and sensitive method of nonaqueous capillary electrophoresis with laser-induced native fluorescence (NACE-LIF) detection for the analysis of chelerythrine and sanguinarine for the first time. As these two alkaloids have some native fluorescence, they were directly detected using a commercially available Ar+ laser without troublesome fluorescent derivatization. The fluorescence was enhanced by nonaqueous media. Compared with previously reported UV detection method, lower limit of detection (LOD) is achieved thanks to the high sensitivity of LIF detection (2.0 ng/mL for chelerythrine and 6.3 ng/mL for sanguinarine). Moreover, with NACE, the baseline separation of these alkaloids is finished within 3.5 min. This method is successfully applied to determine the contents of chelerythrine and sanguinarine in Macleaya cordata (Willd.) R. Br. and Chelidonium majus L.  相似文献   

9.
An LIF detector was integrated into a CE system based on silver mirror coating detection window and small‐angle optical deflection from collinear configuration. For this detection scheme, the incident light beam was focused on capillary through the edge of a lens, resulting in a small deflection angle that deviated 18° from the collinear configuration. Meanwhile, the excitation light and emitted fluorescence were effectively reflected by silver mirror coating at the detection window. The fluorescence was collected through the center of the same lens and delivered to a PMT in the vertical direction. In contrast to conventional collinear LIF detection systems, the fluorescence intensity was greatly enhanced and the background level was significantly eliminated. FITC and FITC‐labeled amino acids were used as model analytes to evaluate the performance with respect to design factors of this system. The limit LOD was estimated to be 0.5 pM for FITC (S/N = 3), which is comparable to that of optimized confocal LIF systems. All the results indicate that the proposed detection scheme will be promising for development of sensitive and low‐cost CE system.  相似文献   

10.
Erythrocytes were fused with liposome for intracellular derivatization of amino acids in cells. The fusion efficiency was evaluated with capillary electrophoresis (CE) and laser-induced fluorescence (LIF) detection. Reagent fluorescein isothiocyanate (FITC) was enveloped in liposomes and introduced into erythrocytes by fusion between liposomes and erythrocytes. The amino acids in the fused cells were derivated by the introduced FITC and the derivated amino acids were extracted for detection by capillary electrophoresis equipped with laser-induced fluorescence detector. The fusion conditions were investigated. It was found that incubation of liposome and erythrocytes in the presence of 13% polyethylene glycol 6000 (PEG 6000) for 15min produced the highest fusion efficiency and kept the erythrocytes stability.  相似文献   

11.
A simple, reliable and reproducible method for the separation and determination of five β-casomorphins (β-CMs, namely TPGN, PGPI, TPGI, TPGP and TPPG) based on glass microfluidic chip electrophoresis and laser-induced fluorescence detection is first described in here. The microfluidic chip electrophoresis and laser-induced fluorescence detection system consisted of a home-made glass "double-T" microchip and a simple LIF detector with excitation and emission wavelengths of 473 and 525 nm, respectively. Fluorescein isothiocyanate (FITC) was used as the precolumn derivatization reagent to label fluorophore on five β-CMs, and the optimum conditions of FITC-derivatization reaction and MCE separation were investigated in detail. Under optimum conditions, five β-CMs were completely separated and detected within 30 min with a detection limit of 18.7-75.1 nmol/L and an RSD (n=5) of 3.0-5.9%, respectively. The proposed method has been successfully used to detect β-CMs in real cheese sample with a recovery of 89-109%, suggesting that our method is sensitive and reliable. These features, as well as its low cost, operation convenience, stability and reusability, make it a promising alternative to β-CMs detection methods.  相似文献   

12.
It was reported that a novel detection method, continuous wave (CW)-based multiphoton excitation (MPE) fluorescence detection with diode laser (DL), has been firstly proposed for capillary electrophoresis (CE). Special design of end-column detection configuration proved to be superior to on-column type, considering the detection sensitivity. Three different kinds of fluorescent tags that were widely used as molecular label in bio-analysis, such as small-molecule dye, fluorescent protein and nano particle or also referred to as quantum dot (QD), have been evaluated as samples for the constructed detection scheme. Quantitative analyses were also performed using rhodamine species as tests, which revealed dynamic linear range over two orders of magnitude, with detection limit down to zeptomole-level. Simultaneous detection of fluorescent dyestuffs with divergent excitation and emission wavelengths in a broad range showed advantage of this scheme over conventional laser-induced fluorescence (LIF) detection. Further investigations on CW-MPE fluorescence detection with diode laser for capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC) separations of fluorescein isothiocyanate (FITC) labeled amino acids indicated good prospect of this detection approach in various micro or nano-column liquid phase separation technologies.  相似文献   

13.
Wall W  Chan K  El Rassi Z 《Electrophoresis》2001,22(11):2320-2326
In this report, we describe a surfactant-mediated electrokinetic capillary chromatography (SM-EKC) system for the separation of 9-fluoroenylmethyl chloroformate (FMOC)-derivatized anilines by capillary electrophoresis (CE). The SM-EKC system consisted of dioctyl sulfosuccinate (DOSS)/acetonitrile mixtures and was suited for the CE separation of the relatively hydrophobic FMOC-aniline analytes and other neutral compounds, e.g. alkylphenyl ketones. While the organic modifier acetonitrile (ACN) allowed the solubilization of the hydrophobic solutes and maintained the DOSS surfactant in its monomeric form by inhibiting micellization, the DOSS surfactant associated with the FMOC anilines to a varying degree thus leading to their differential migration and separation. Under these conditions, the FMOC-anilines were readily detected at the 10(-6) M level by UV at 214 nm and at the 10(-8) M level by laser-induced fluorescence (LIF) using a solid-state UV laser operating at 266 nm line as the excitation wavelength. The FMOC precolumn derivatization was also readily performed in lake water spiked with anilines at near the limit of detection (LOD) level. The lake water matrix showed no significant effects on the extent of derivatization at the LOD level as well as on the detection of the analytes due to the selectivity of the FMOC derivatization. The derivatization and detection of spiked lake water necessitated only the removal of microparticles by microfiltration prior to derivatization and detection.  相似文献   

14.
Precise measurement of nitric oxide (NO) is of great importance to understand the function of NO in liver and the mechanism of liver injury. 8‐(3’,4’‐Diamino phenyl)‐3,5‐(2‐hydroxyphenyl)‐dimethylene pyrrole (BOPB), a fluorescent probe in the red region (>600 nm) newly developed in our group, has good photostability and excitation/emission wavelength of 622/643 nm matching well with commercial 635 nm semiconductor laser of CE‐LIF detection. Therefore, BOPB was used in CE‐LIF for the determination of NO in mice liver. Both derivatization and separation conditions were optimized. Derivatization reaction of BOPB and NO was carried out in pH 7.4 PBS buffer at 35°C for 12 min and the separation of NO derivative of BOPB (BOPB‐T) was achieved within 7.0 min in pH 9.0 running buffer containing 15 mM H3BO3–NaOH and 15 mM SDS. Good linearity was found in the range of 1.0 × 10?9–5.0 × 10?7 M with the LOD of 0.02 nM. The proposed method was applied to the analysis of NO in real samples, and NO concentration was obviously increased in acute liver injury of mice. Compared to existing derivatization‐based CE‐LIF methods for NO, this method has lower LOD and less background interference owing to detection wavelength of BOPB in the red region.  相似文献   

15.
In this study, a rapid and sensitive method is described for the catecholamines detection in rat brain. CE with LIF detection for the determination of FITC derivatized catecholamines (dopamine, epinephrine, and norepinephrine) was demonstrated. Conventional water bath and microwave‐assisted derivatization methods were employed and a significant reduction in the derivatization time from 2 h for the conventional water bath at room temperature (ca. 25°C) to 2 min for the microwave‐assisted derivatization was achieved. Online sample concentration of field‐amplified sample stacking (FASS) method was employed to achieve higher sensitivities (the detection limits obtained in the normal injection mode ranged from 2.6 to 4.5 ng L?1 and in the FASS mode ranged from 22 to 34 pg L?1). Furthermore, this microwave‐assisted derivatization CE–LIF method successfully determined catecholamines in rat brain with as low as 100 ng L?1 (FASS mode) to 10 μg L?1 (normal injection mode). This CE–LIF method provided better detection ability when compared to the best reports on catecholamines analyses.  相似文献   

16.
A novel method is presented to detect DNA fragments separated by capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection using inverse-flow derivatization. In electrophoresis, the intercalating dye, thiazol orange was only added to the separation buffer at the positive polarity. The negatively charged DNA fragments migrated from the negative polarity to the positive polarity, while the positively charged dye migrated in the opposite direction. When DNA fragments met with dye ions, the DNA–dye complexes were formed. The complexes continued migrating to the positive end, due to their net negative charges. When the complexes passed through the detection window, the fluorescent signals were generated. Importantly, DNA fragments migrated as their native state before DNA–dye complexes were formed. This procedure was used to detect double stranded DNA (dsDNA) and single stranded DNA (ssDNA) fragments, and polymerase chain reaction (PCR) products. The excellent resolution and good reproducibility of DNA fragments were achieved in non-gel sieving medium. This procedure may be useful in genetic mutation/polymorphism detections.  相似文献   

17.
The potential of a recently developed lamp-based fluorescence detector for the analysis of underivatised proteins by capillary electrophoresis (CE) was investigated. Fluorescence detection (Flu) was achieved using optical light guides to deliver excitation light from a Xenon–Mercury lamp to the capillary detection window and to collect fluorescence emission and lead it to a photomultiplier. The performance of the detector was evaluated by monitoring the native fluorescence of the amino acid tryptophan and the proteins α-chymotrypsinogen A, carbonic anhydrase II, lysozyme and trypsinogen upon excitation at 280 nm. The test compounds were analysed using background electrolytes (BGEs) of sodium phosphate at pH 3.0 and 11.3. The results were compared to experiments of CE with UV absorbance detection. For tryptophan, a linear fluorescence response was obtained with a dynamic range of over 4 orders of magnitude, and a limit of detection (LOD) of 6.7 nM. This LOD was a factor of 200 more favourable than UV detection at 280 nm, and a factor of 20 better than detection at low-UV wavelengths. All tested proteins showed linear fluorescence responses up to 250 μg/mL. LODs were typically in the 10–20 nM range. These LODs were a factor of 25 lower than for UV detection at 280 nm, and comparable to UV detection at low-UV wavelengths. Overall, Flu yields much more stable baselines, especially with a BGE of high pH. The applicability of CE–Flu is demonstrated by the analysis of a degraded protein mixture, and of an expired formulation of the protein drug human growth hormone, indicating that protein degradation products can be selectively detected.  相似文献   

18.
Anthracyclines are chemotherapeutic drugs that are widely used in the treatment of cancers such as lung and ovarian cancers. The simultaneous determination of the anthracyclines, daunorubicin, doxorubicin and epirubicin, was achieved using CE coupled to LIF, with an excitation and emission wavelength of 488 and 560 nm, respectively. Using a borate buffer (105 mM, pH 9.0) and 30% MeOH, a stable and reproducible separation of the three anthracyclines was obtained. The method developed was shown to be capable of monitoring the therapeutic concentrations (50-50 000 ng/mL) of anthracyclines. LODs of 10 ng/mL, calculated at an S/N = 3, were achieved. Using the CE method developed, the in vitro protein binding to plasma was measured by ultrafiltration, and from this investigation the estimated protein binding was determined to be in the range of 77-94%.  相似文献   

19.
A method has been developed for the analysis of the antidepressant drug sertraline together with its main metabolite N-desmethylsertraline (DMS) in human plasma. It is based on CE with LIF detection (lambda = 488 nm). A SPE procedure is employed for biological sample pretreatment, followed by a derivatization step with FITC; reboxetine was the internal standard. The effect of CD, acetone and N-methyl-D-glucamine (GLC) as constituents of the BGE for analyte separation was investigated. The final BGE consisted of 20 mM carbonate buffer, pH 9.0, with 2.5 mM heptakis(2,6-di-O-methyl)-beta-CD, 50 mM GLC and 20% v/v acetone. With 30 kV applied voltage, the electrophoretic run is completed in 7.5 min. Linearity was observed in the plasma concentration range from 3.0 to 500 ng/mL for sertraline and 4.0 to 500 ng/mL for DMS. Extraction yield was >97.1%, precision - expressed as RSD% - was <3.7, accuracy (recovery) was >95.6%. Due to its sensitivity and selectivity, the method was suited for the analysis of plasma samples from patients undergoing therapy with sertraline.  相似文献   

20.
采用自行设计、组装的毛细管电泳光导纤维发光二极管诱导荧光检测装置,建立了一种直接测定免疫球蛋白G(IgG)的方法。以蓝色发光二极管(LED)为荧光检测器的激发光源,荧光素异硫氰酸酯(FITC)为柱前衍生试剂,采用毛细管区带电泳,以20 mmol/L硼砂缓冲溶液(pH9.2)为背景电解液进行分离检测。通过对衍生反应条件和电泳分离条件进行优化,确定了最佳实验条件,在该条件下,IgG的线性范围为4.5×10-8~1.2×10-6g/L,检出限为2.0×10-8g/L。该方法简单、高效、选择性好,无需前处理,可用于人血清中IgG含量的测定。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号