首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel solid-phase microextraction coating of phosphorous-containing titanium oxide composite was developed using titanium fiber as a support and a titanium source by hydrothermal oxidation in a phosphoric acid solution containing hydrogen peroxide. The morphology of the fiber coatings was controlled by the conditions of the hydrothermal oxidation reaction. The oriented nanofiber coating was employed to extract several types of representative aromatic analytes. The experimental results demonstrated that the as-prepared fiber exhibited excellent extraction efficiency toward polycyclic aromatic hydrocarbons. Combined with high-performance liquid chromatography with ultraviolet detection, main extraction conditions were optimized, including pH, ionic strength, extraction temperature, stirring rate, extraction time and desorption time. The established method presented good linearity from 0.05 to 200 μg/L with limit of detection ranging from 0.012 to 0.126 μg/L. This convenient and green procedure was suitable for the selective extraction and determination of typical polycyclic aromatic hydrocarbons in environmental water samples. The relative recoveries of 85.8–112% were obtained for the determination of target polycyclic aromatic hydrocarbons in water samples spiked with 5.0 and 15.0 μg/L. Moreover, the as-prepared fiber showed at least 210 extraction/desorption cycles due to its high mechanical and chemical stability.  相似文献   

2.
A novel C18 functionalized graphene oxide (GO) coated solid-phase microextraction fiber was prepared by a novel protocol. Based on the strong van der Waals interaction present in GO and abundant oxygenous groups in GO sheets, a simple layer-by-layer self-assembly method was used in the preparation process and then C18 was successfully self-assembled on GO via C-O-Si bonding. Coupled with gas chromatography, extraction performance of the fiber was tested with polycyclic aromatic hydrocarbons (PAHs) as model analytes. The fiber not only exhibited excellent extraction efficiency and selectivity, but also showed many advantages including high rigidity, long service life and well stability toward organic solvent, acidic and alkali solutions, and high temperature. The relative standard deviations for single-fiber repeatability and fiber-to-fiber reproducibility were less than 7.26 and 17.25%, respectively. The detection limits to the PAHs were less than 0.08 μg L(-1) and the calibration curves were linear in a wide range for all analytes. The as-established Solid-phase microextraction GC method was also successfully used for determination of PAHs in two real water samples.  相似文献   

3.
A novel graphene oxide decorated with silver nanoparticles coating on a stainless‐steel fiber for solid‐phase microextraction was prepared. Scanning electron microscopy and X‐ray photoelectron spectroscopy were used to characterize the coating surface and showed that silver nanoparticles were dispersed on the wrinkled graphene oxide surface. Coupled to gas chromatography with flame ionization detection, the extraction abilities of the fiber for polycyclic aromatic hydrocarbons were examined in the headspace solid‐phase microextraction mode. The extraction parameters including adsorption time, adsorption temperature, salt concentration, desorption time and desorption temperature were investigated. Under the optimized condition, wide linearity with low limits of detection from 2 to 10 ng/L was obtained. The relative standard deviations for single‐fiber repeatability and fiber‐to‐fiber reproducibility were less than 10.6 and 17.5%, respectively. The enrichment factors were from 1712.5 to 4503.7, showing the fiber has good extraction abilities. Moreover, the fiber exhibited a good stability and could be reused for more than 120 times. The established method was also applied for determination of polycyclic aromatic hydrocarbons in two real water samples and the recoveries of analytes ranged from 84.4–116.3% with relative standard deviations less than 16.2%.  相似文献   

4.
A novel adsorbent made of polydopamine‐functionalized magnetic graphene and carbon nanotubes hybrid nanocomposite was synthesized and applied to determine 16 priority polycyclic aromatic hydrocarbons by magnetic solid phase extraction in water samples. FTIR spectroscopy, transmission electron microscopy, scanning electron microscopy, and Raman spectroscopy consistently indicate that the synthesized adsorbents are made of core–shell nanoparticles well dispersed on the surface of graphene and carbon nanotubes. The major factors affecting the extraction efficiency, including the pH value of samples, the amount of adsorbent, adsorption time and desorption time, type and volume of desorption solvent, were systematically optimized. Under the optimum extraction conditions, a linear response was obtained for polycyclic aromatic hydrocarbons between concentrations of 10 and 500 ng/L with the correlation coefficients ranging from 0.9958 to 0.9989, and the limits of detection (S/N = 3) were between 0.1 and 3.0 ng/L. Satisfactory results were also obtained when applying these magnetic graphene/carbon nanotubes/polydopamine hybrid nanocomposites to detect polycyclic aromatic hydrocarbons in several environmental aqueous samples.  相似文献   

5.
A novel mesoporous‐coated stainless steel wire microextraction coupled with the HPLC procedure for quantification of four polycyclic aromatic hydrocarbons in water has been developed, based on the sorption of target analytes on a selectively adsorptive fiber and subsequent desorption of analytes directly into HPLC. Phenyl‐functionalized mesoporous materials (Ph‐SBA‐15) were synthesized and coated on the surfaces of a stainless steel wire. Due to the high porosity and large surface area of the Ph‐SBA‐15, high extraction efficiency is expected. The influence of various parameters on polycyclic aromatic hydrocarbons extraction efficiency were thoroughly studied and optimized (such as the extraction temperature, the extraction time, the desorption time, the stirring rate and the ionic strength of samples). The results showed that each compound for the analysis of real water samples was tested under optimal conditions with the linearity ranging from 1.02×10?3 to 200 μg/ L and the detection limits were found from 0.32 to 2.44 ng/ L, respectively. The RSD of the new method was smaller than 4.10%.  相似文献   

6.
Cotton fiber is an environmentally friendly and natural material with a certain extraction capacity, while its enrichment ability is poor. In order to improve the extraction efficiency of cotton fibers, it was carbonized to form a layer of amorphous carbon as the sorbent by a simple carbonization method. Carbonized cotton fibers were filled into a polyetheretherketone tube for in‐tube solid‐phase microextraction. The carbonization time was investigated to obtain high extraction efficiency. Coupled to high‐performance liquid chromatography, the extraction tube was evaluated with polycyclic aromatic hydrocarbons, estrogens and phthalates, and it exhibited best extraction efficiency for polycyclic aromatic hydrocarbons. Under the optimum conditions, an online analysis method for several polycyclic aromatic hydrocarbons was established with large linear ranges (0.016–0.20 μg/L), low limits of detection (0.005–0.020 μg/L), and high enrichment factors (948–2874). Analysis method was successfully applied to the detection of targets in the real samples and shown satisfactory durability and chemical stability. Moreover, the relative recoveries ranged from 82 to 119.2%, which demonstrated the applicability of carbonized cotton fibers in sample preparation. Compared with other reported methods, the proposed method provided shorter extraction time, higher enrichment factors, comparable limits of detection, and recoveries.  相似文献   

7.
通过3-巯基丙基三甲氧基硅烷处理银层包裹的不锈钢纤维,得到Si-OH功能化的纤维,氧化石墨烯被层层键合到Si-OH功能化的纤维上,还原氧化石墨烯得到石墨烯层层键合的固相微萃取纤维。该方法制备的新型石墨烯层层键合的固相微萃取纤维具有制备简单,机械性能强,萃取涂层牢固,萃取能力强等优势。建立具有较宽线性范围(5~200μg/L)、较低检测限(0.007~0.09μg/L)的固相微萃取-气相色谱分析方法,用该方法测定河水和雨水中多环芳烃的含量。所制备的新型纤维重现性好、稳定性高、萃取能力强,可实现对多环芳烃的痕量检测。  相似文献   

8.
A layer by layer graphenized graphite/polyaniline coating was fabricated on commercial pencil lead substrate by an in situ facile, fast and efficient electrochemical procedure. The electrodeposited polyaniline film on surface‐confined graphene structure can integrate the advantages of the both layers and was used for solid‐phase microextraction. Effective experimental parameters in electrochemical production of graphene nanosheets and electropolymerization of aniline were optimized. The prepared fiber was used for extraction and determination of four polycyclic aromatic hydrocarbons: phenanthrene, anthracene, fluoranthene and pyrene in aqueous samples by high performance liquid chromatography. The fiber coating was characterized by Fourier transform infrared spectroscopy, X‐ray diffraction and scanning electron microscopy. Under the optimized conditions, the coating provided good linear ranges (0.10–25 μg/L for phenanthrene, 0.05–12.5 μg/L for anthracene, 0.825–99 μg/L for fluoranthene and 0.625–75 μg/L for pyrene (R2 = 0.999)) and limits of detection, 0.016 to 0.275 μg/L. The produced coating has several attractive features such as high stability, low cost and long operation time.  相似文献   

9.
采用水热处理和溶胶-凝胶法在镍钛合金(NiTi)纤维表面组装了二氧化硅纳米片(SiO2NFs),成功制备了新型SiO2纤维涂层,并用苯基三氯硅烷进行了自组装表面修饰,得到了可用于固相微萃取(SPME)的NiO/TiO2@SiO2NFs-Ph纤维。将制备的SPME纤维与高效液相色谱联用,通过对典型芳香化合物的分析评价了所制备纤维的萃取性能。该纤维对多环芳烃(PAHs)具有较高的萃取率和良好的萃取选择性。实验优化了pH值、搅拌速率、萃取温度、萃取时间和离子强度对PAHs萃取率的影响。在优化条件下,5种PAHs在各自的范围内呈良好的线性关系,相关系数(r)大于0.999,检出限为0.013~0.108 μg/L。使用单根纤维对含有50 μg/L PAHs的加标水样进行萃取,其含量的日内及日间RSD分别为4.1%~5.9%和4.8%~6.8%。实际环境水样中5种PAHs在10 μg/L和30 μg/L加标水平下的加标回收率分别为90.8%~105.7%和93.6%~103.1%。该法制备的NiO/TiO2@SiO2NFs-Ph纤维稳定性高、制备重现性好,适用于环境水样中目标PAHs的富集和测定。  相似文献   

10.
A novel palladium solid‐phase microextraction coating was fabricated on a stainless‐steel wire by a simple in situ oxidation–reduction process. The palladium coating exhibited a rough microscaled surface and its thickness was about 2 μm. Preparation conditions (reaction time and concentration of palladium chloride and hydrochloric acid) were optimized in detail to achieve sufficient extraction efficiency. Extraction properties of the fiber were investigated by direct immersion solid‐phase microextraction of several polycyclic aromatic hydrocarbons and phthalate esters in aqueous samples. The extracted analytes were transferred into a gas chromatography system by thermal desorption. The effect of extraction and desorption conditions on extraction efficiency were investigated. Under the optimum conditions, good linearity was obtained and correlation coefficients between 0.9908 and 0.9990 were obtained. Limits of detection were 0.05–0.10 μg/L for polycyclic aromatic hydrocarbons and 0.3 μg/L for phthalate esters. Their recoveries for real aqueous samples were in the range from 97.1 to 121% and from 89.1 to 108%, respectively. The intra‐ and interday tests were also investigated with three different addition levels, and satisfactory results were also obtained.  相似文献   

11.
Given the potential risks of chlorinated polycyclic aromatic hydrocarbons, the analysis of their presence in water is very urgent. We have developed a novel procedure for determining chlorinated polycyclic aromatic hydrocarbons in water based on solid‐phase extraction coupled with gas chromatography and mass spectrometry. The extraction parameters of solid‐phase extraction were optimized in detail. Under the optimal conditions, the proposed method showed wide linear ranges (1.0–1000 ng/L) with correlation coefficients ranging from 0.9952 to 0.9998. The limits of detection and the limits of quantification were in the range of 0.015–0.591 and 0.045–1.502 ng/L, respectively. Recoveries ranged from 82.5 to 102.6% with relative standard deviations below 9.2%. The obtained method was applied successfully to the determination of chlorinated polycyclic aromatic hydrocarbons in real water samples. Most of the chlorinated polycyclic aromatic hydrocarbons were detected and 1‐monochloropyrene was predominant in the studied water samples. This is the first report of chlorinated polycyclic aromatic hydrocarbons in water samples in China. The toxic equivalency quotients of chlorinated polycyclic aromatic hydrocarbons in the studied tap water were 9.95 ng the toxic equivalency quotient m?3. 9,10‐Dichloroanthracene and 1‐monochloropyrene accounted for the majority of the total toxic equivalency quotients of chlorinated polycyclic aromatic hydrocarbons in tap water.  相似文献   

12.
CdS nanoparticles coated on a stainless‐steel wire for solid‐phase microextraction was prepared. Scanning electron microscopy showed that the CdS nanoparticles clustered together to form a porous structure and X‐ray diffraction confirmed that the CdS nanoparticles were the wurtzite phase. Coupled to gas chromatography with flame ionization detection, the extraction abilities of the fiber for polycyclic aromatic hydrocarbons were examined by the headspace method. The parameters of adsorption time, adsorption temperature, salt concentration, desorption time, and desorption temperature were investigated and optimized. For the method, wide linearity and low limits of detection from 5 to 15 ng/L were obtained. The relative standard deviations for single‐fiber repeatability and fiber‐to‐fiber reproducibility were less than 10.2 and 12.6%, respectively. The enrichment factors were from 1155.6 to 3905.4, showing the fiber has good extraction capacity for polycyclic aromatic hydrocarbons. Moreover, the fiber can be used more than 50 times, exhibiting good stability. The established method was also used to analyze the polycyclic aromatic hydrocarbons in two real samples, and the recoveries from 82.7 to 114.2% further proved the reliability of the method.  相似文献   

13.
Magnetic polyimide poly(4,4′‐oxydiphenylene‐pyromellitimide) nanoparticles were successfully synthesized and developed for the solid‐phase extraction of polycyclic aromatic hydrocarbons in seawater samples. The aromatic rings of polyimide coating provided a good adsorption capacity (28.3–42.5 mg/g) for polycyclic aromatic hydrocarbons because of the π–π stacking interaction. The developed method was used as a simple, fast, and efficient extraction and preconcentration technique for the trace analysis of polycyclic aromatic hydrocarbons. The high chemical, physical and thermal stability, excellent reusability, and good magnetic properties are the merits of the sorbent. High preconcentration factors (41–63) were obtained. The sorbent was also characterized by Fourier transform infrared spectroscopy, scanning electron microscopy, energy dispersive X‐ray spectrometry, transmission electron microscopy, and vibrating sample magnetometry. After optimizing several appropriate extraction parameters, the results indicated that the extraction recoveries of polycyclic aromatic hydrocarbons were in the range of 61.6–94.7%, with relative standard deviations between 2.9 and 5.4%, the calibration graph was linear in the concentration range of 1–100 μg/L (r > 0.9991) with limit of detection in the range of 0.15–0.19 μg/L (n = 3). Seawater samples were analyzed as real samples and good recoveries (68.5–99.5%) were obtained at different spiked values.  相似文献   

14.
Dynamic three-phase hollow fiber liquid-liquid-liquid microextraction (HF-LLLME) based on two immiscible organic solvents, with automated movement of organic acceptor phase to facilitate mass transfer was introduced for the first time. Polycyclic aromatic hydrocarbons were used as model compounds and extracted from water and soil samples. The extraction involved filling an 8 cm length of hollow fiber with 25 μL of organic acceptor solvent using a microsyringe, followed by impregnation of the pores in the fiber wall with n-dodecane. The fiber was then immersed in 20 mL of aqueous sample solution. During extraction, the organic acceptor phase was repeatedly moved in the lumen of the hollow fiber by movement of the syringe plunger controlled by programmable syringe pump. Following this microextraction, 2 μL of organic acceptor phase was injected into gas chromatography-flame ionization detector. This new technique provided up to 554-fold preconcentration of the analytes under the optimized conditions. Good repeatabilities (with RSDs ≤8.4%) were obtained. Detection limits were in the range of 0.2-0.5 μg/L. The utilization of the proposed method for extraction of the polycyclic aromatic hydrocarbons from different real samples (such as water and soil samples) also gave good precision and recovery.  相似文献   

15.
采用阳极氧化法在镍钛合金(NiTi)纤维上原位生长了双金属氧化物纳米孔(NiTiONPs)涂层,通过扫描电镜(SEM)和能谱(EDS)考察了电解质组成和电压对形貌的影响。将NiTiONPs涂层的NiTi纤维与高效液相色谱-紫外检测器联用,研究了4种典型芳香分析物的萃取性能。结果表明,富含TiO2的NiTiONPs涂层对多环芳烃(PAHs)具有良好的萃取效率,尤其对苯并[a]芘的萃取选择性优于市售聚二甲基硅氧烷纤维和聚丙烯酸酯纤维。在优化条件下,PAHs的线性范围为0.05~200μg/L,相关系数均大于0.999,检出限为0.012~0.134μg/L。对单支纤维日内和日间分析的相对标准偏差(RSDs)分别为4.0%~5.5%和6.0%~6.8%,使用分批组装的5支纤维分析的RSDs为6.4%~7.6%。实际水样分析的加标回收率为84.5%~111.5%。所制备NiTi纤维至少可重复使用250次以上,重现性好。  相似文献   

16.
三苄基杯[6]芳烃固相微萃取复合涂层的研制及其应用   总被引:2,自引:1,他引:1  
采用溶胶-凝胶方法制备了三苄基杯[6]芳烃/羟基硅油(C[6]/OH-TSO)固相微萃取(SPME)探头, 通过对多环芳烃和酞酸酯(PAEs)的分析考察了新型C[6]/OH-TSO探头的性能. 结果表明: 杯[6]芳烃SPME探头对这些非极性和弱极性的芳香化合物有很好的萃取效果和选择性, 具有耐高温、使用寿命长等特点. 建立了SPME与气相色谱-氢火焰(GC-FID)联用测定化妆品中PAEs的方法. 该方法检测限低, 重现性好(RSD<9%), 线性范围宽(2~3个数量级). 回收率在83.42%~98.85%之间.  相似文献   

17.
Polyaniline coated cigarette filters were successfully synthesized and used as a solid‐phase extraction sorbent for the extraction and preconcentration of polycyclic aromatic hydrocarbons in water samples. The polyaniline helped to enhance the adsorption ability of polycyclic aromatic hydrocarbons on the sorbent through π–π interactions. The high porosity and large surface area of the cigarette filters helped to reduce backpressure and can be operated with high sample flow rate without loss of extraction efficiency. The developed sorbent was characterized by Fourier transform infrared spectroscopy and scanning electron microscopy. The parameters that affected the extraction efficiencies, i.e. polymerization time, type of desorption solvent and its volume, sample flow rate, sample volume, sample pH, ionic strength, and organic modifier were investigated. Under the optimal conditions, the method was linear over the range of 0.5–10 μg/L and a detection limit of 0.5 ng/L. This simple, rapid, and cost‐effective method was successfully applied to the preconcentration of polycyclic aromatic hydrocarbons from water samples. The developed method provided a high enrichment factor with good extraction efficiency (85–98%) and a relative standard deviation <10%.  相似文献   

18.
To enhance the extraction performance, a mesoporous silica was modified with ordered mesoporous carbon for solid‐phase microextraction. Three stainless‐steel wires coated with the mesoporous material were placed in a polyetheretherketone tube for getting an extraction tube. The tube was coupled to high‐performance liquid chromatography with diode array detector, and the online analysis system was constructed. Then its extraction performance was evaluated using hydrophobic polycyclic aromatic hydrocarbons, phthalates, and hydrophilic neonicotinoids. The best selectivity was presented for polycyclic aromatic hydrocarbons. Several main conditions were optimized such as sampling volume, sampling rate, methanol concentration in the sample, and desorption time, a rapid and sensitive analytical method was established toward polycyclic aromatic hydrocarbons. The analytical method exhibited wide linear range from 0.017 to 15 µg/L with acceptable correlation coefficients more than 0.9990, limits of detection in 0.005‐0.020 µg/L, limits of quantification ranging from 0.017 to 0.066 µg/L as well as large enrichment factors of 377‐2314. It was successfully applied to detect trace polycyclic aromatic hydrocarbons in some real water samples including tap water, snow water, and domestic sewage.  相似文献   

19.
In this work, a graphene composite was coated onto etched stainless‐steel wire through a sol–gel technique and it was used as a solid‐phase microextraction (SPME) fiber. The prepared fiber was characterized by SEM, which revealed that the fiber had a highly porous structure. The application of the fiber was evaluated through the headspace SPME of five halogenated aromatic hydrocarbons (chlorobenzene, bromobenzene, 1,3‐dichlorobenzene, 1,2‐dichlorobenzene, and 1,2,4‐trichlorobenzene) in water samples followed by GC with flame ionization detection. The main factors influencing the extraction efficiency, including headspace volume, extraction time, extraction temperature, stirring rate, ionic strength of sample solution, and desorption conditions, were studied and optimized. Under the optimum conditions, the linearity of the method ranged from 2.5 to 800.0 μg/L for 1,2,4‐trichlorobenzene and from 2.5 to 500.0 μg/L for chlorobenzene, bromobenzene, 1,3‐dichlorobenzene, and 1,2‐dichlorobenzene, with the correlation coefficients (r) ranging from 0.9962 to 0.9980, respectively. The LODs (S/N = 3) of the method for the analytes were in the range between 0.5 and 1.0 μg/L. The recoveries of the method for the analytes obtained for the spiked water samples at 50.0 and 250.0 μg/L were from 76.0 to 104.0%.  相似文献   

20.
A highly porous fiber coated with polythiophene/hexagonally ordered silica nanocomposite was prepared for solid‐phase microextraction (SPME). The prepared nanomaterial was immobilized onto a stainless‐steel wire for the fabrication of the SPME fiber. Polythiophene/hexagonally ordered silica nanocomposite fibers were used for the extraction of some polycyclic aromatic hydrocarbons from water samples. The extracted analytes were transferred to the injection port of a gas chromatograph using a laboratory‐designed SPME device. The results obtained prove the ability of the polythiophene/hexagonally ordered silica material as a new fiber for the sampling of organic compounds from water samples. This behavior is due most probably to the increased surface area of the polythiophene/hexagonally ordered silica nanocomposite. A one‐at‐a‐time optimization strategy was applied for optimizing the important extraction parameters such as extraction temperature, extraction time, ionic strength, stirring rate, and desorption temperature and time. Under the optimum conditions, the LOD of the proposed method is 0.1–3 pg/mL for analysis of polycyclic aromatic hydrocarbons from aqueous samples, and the calibration graphs were linear in a concentration range of 0.001–20 ng/mL (R2 > 0.990) for most of the polycyclic aromatic hydrocarbons. The single fiber repeatability and fiber‐to‐fiber reproducibility were less than 8.6 and 19.1% (n = 5), respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号