首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 63 毫秒
1.
PVC-based membranes of meso-tetrakis-{4-[tris-(4-allyl dimethylsilyl-phenyl)-silyl]-phenyl}porphyrin (I) and (sal)2trien (II) as electroactive material with dioctylphthalate (DOP), tri-n-butylphosphate (TBP), chloronapthalene (CN), dibutylphthalate (DBP) and dibutyl(butyl) phosphonate (DBBP) as plasticising solvent mediators have been found to act as Ni2+ selective sensor. The best performance was obtained with the sensor having a membrane of composition of I: sodium tetraphenyl borate: PVC in the ratio 5:5:150. The sensor exhibits Nernstian response in the activity range 2.5 × 10−6 to 1.0 × 10−1 M, performs satisfactorily over wide pH range (2–5.5) with a fast response time (8 s). The sensor was found to work satisfactorily in partially non-aqueous media up to 20% (v/v) content of methanol or ethanol and acetone and could be used over a period of 4 months. Potentiometric selectivity coefficients determined by matched potential method (MPM) indicate excellent selectivity for Ni2+ ions. The sensors could be used successfully in the estimation of nickel in different brand of chocolates and also as an indicator electrode in potentiometric titration.  相似文献   

2.
Gupta VK  Goyal RN  Al Khayat M  Kumar P  Bachheti N 《Talanta》2006,69(5):1149-1155
Poly(vinyl chloride) (PVC) based membranes containing 4-tert-butylcalix[4]arene (I) as an electroactive material alongwith anion excluder sodiumtetraphenylborate (NaTPB) and plasticizer tri-butylphosphate (TBP) have been developed to fabricate a new zinc-selective sensor. Out of various compositions, the best performance was exhibited by the membrane having I, NaTPB, TBP and PVC in the ratio 8:5:100:200 (w/w). The sensor works well in the concentration range 9.8 × 10−6 to 1.0 × 10−1 mol dm−3 with a near-Nernstian slope of 28.0 ± 1.0 mV/decade of activity. The detection limit is down to 5.0 × 10−7 mol dm−3. The working pH range of this sensor is 2.5–4.3 and it works well in partially non-aqueous medium up to 15% (v/v) (methanol, ethanol and acetone). It exhibits a fast response time of 30 s and could be used for more than four months without any considerable change in response characteristics. It has excellent selectivity for Zn(II) over other mono-, bi- and trivalent cations which have been reported to cause interference in the working of other sensors. It has been successfully used as an indicator electrode in the potentiometric titration of Zn(II) against EDTA and also to estimate zinc ions in industrial waste waters.  相似文献   

3.
A new PVC membrane electrode for Zn2+ ions based on tetra(2-aminophenyl) porphyrin (TAPP) as membrane carrier is prepared. The sensor exhibits a linear stable response over a wide concentration range (5.0×10−5 to 1.0×10−1 M) with a slope of 26.5 mV/decade and a limit of detection 3.0×10−5 M (1.96 ppm). It has a response time of about l0 s and can be used for at least 8 months without any divergence in potential. The propose membrane sensor revealed good selectivities for Zn2+ over a wide variety of other metal ions and can be used in pH range of 3.0–6.0. It was successfully applied to the direct determination of zinc in a pharmaceutical sample and also as an indicator electrode in potentiometric titration of Zn2+ ions.  相似文献   

4.
Li CY  Zhang XB  Jin Z  Han R  Shen GL  Yu RQ 《Analytica chimica acta》2006,580(2):143-148
An amide-linked 2,6-bis{[(2-hydroxy-5-tert-butylbenzyl)(pyridyl-2-methyl)-amino]-methyl}-4-methylphenol-ruthenium(II) tris(bipyridine) 2PF6 complex, 1, was first used to recognize Co(II) in EtOH/H2O (1:1, v/v) solution, with the ruthenium(II) tris(bipyridine) moiety selected as a fluorophore and the multi-substituted phenol unit chosen as a receptor. The fluorescence quenching of 1 was attributed to the formation of an inclusion complex between multi-substituted phenol unit and Co(II) by 1:1 complex ratio (K = 2.5 × 105), which has been utilized as the basis of the fabrication of the Co(II)-sensitive fluorescent chemosensor. The analytical performance characteristics of the proposed Co(II)-sensitive chemosensor were investigated. The sensor can be applied to the quantification of Co(II) with a linear range covering from 1.0 × 10−7 to 5.0 × 10−5 M and a detection limit of 5 × 10−8 M. The experiment results show that the response behavior of 1 to Co(II) is pH-independent in medium condition (pH 4.5–9.5) and show excellent selectivity for Co(II) over transition metal cations except Cu(II). The chemosensor has been used for determination of Co(II) in water samples.  相似文献   

5.
Hassan SS  Ali MM  Attawiya AM 《Talanta》2001,54(6):1153-1161
Two novel uranyl PVC matrix membrane sensors responsive to uranyl ion are described. The first sensor incorporates tris(2-ethylhexyl)phosphate (TEHP) as both electroactive material and plasticizer and sodium tetraphenylborate (NaTPB) as an ion discriminator. The sensor displays a rapid and linear response for UO22+ ions over the concentration range 1×10−1–2×10−5 mol l−1 UO22+ with a cationic slope of 25.0±0.2 mV decade−1. The working pH range is 2.8–3.6 and the life span is 4 weeks. The second sensor contains O-(1,2-dihydro-2-oxo-1-pyridyl)-N,N,N′,N′-bis(tetra-methylene)uronium hexafluorophosphate (TPTU) as a sensing material, sodium tetraphenylborate as an ion discriminator and dioctyl phenylphosphonate (DOPP) as a plasticizer. Linear and stable response for 1×10−1–5×10−5 mol l−1 UO22+ with near-Nernstian slope of 27.5±0.2 mV decade−1 are obtained. The working pH range is 2.5–3.5 and the life span of the sensor is 6 weeks. Interference from many inorganic cations is negligible for both sensors. However, interference caused by some ions (e.g. Th4+, Cu2+, Fe3+) is eliminated by a prior ion exchange or solvent extraction step. Direct potentiometric determination of as little as 5 μg ml−1 uranium in aqueous solutions shows an average recovery of 97.2±1.3%. Application for the determination of uranium at levels of 0.01–1 wt.% in naturally occurring and certified ores gives results with good correlation with data obtained by X-ray fluorescence.  相似文献   

6.
In this work, nickel hexacyanoferrate-modified electrode was developed to determine potassium ions in biodiesel by potentiometry. The modified electrodes exhibit a linear response to potassium ions in the concentration range of 4.0 × 10−5 to 1.0 × 10−2 mol L−1, with a detection limit of 1.9 × 10−5 mol L−1, and a near-Nernstian slope (53–55 mV per decade) at 25 °C. The method developed in this work was compared with flame photometry and the potassium concentration found in biodiesel showed that the modified electrode method gives results similar to those obtained by flame photometry.  相似文献   

7.
Li Liu  Jun-feng Song  Peng-fei Yu  Bin Cui 《Talanta》2007,71(5):1842-1848
A novel voltammetric method for the determination of β-d-glucose (GO) is proposed based on the reduction of Cu(II) ion in Cu(II)(NH3)42+–GO complex at lanthanum(III) hydroxide nanowires (LNWs) modified carbon paste electrode (LNWs/CPE). In 0.1 mol L−1 NH3·H2O–NH4Cl (pH 9.8) buffer containing 5.0 × 10−5 mol L−1 Cu(II) ion, the sensitive reduction peak of Cu(II)(NH3)42+–GO complex was observed at −0.17 V (versus, SCE), which was mainly ascribed to both the increase of efficient electrode surface and the selective coordination of La(III) in LNW to GO. The increment of peak current obtained by deducting the reduction peak current of the Cu(II) ion from that of the Cu(II)(NH3)42+–GO complex was rectilinear with GO concentration in the range of 8.0 × 10−7 to 2.0 × 10−5 mol L−1, with a detection limit of 3.5 × 10−7 mol L−1. A 500-fold of sucrose and amylam, 100-fold of ascorbic acid, 120-fold of uric acid as well as gluconic acid did not interfere with 1.0 × 10−5 mol L−1 GO determination.  相似文献   

8.
Singh AK  Mehtab S  Saxena P 《Talanta》2006,69(5):1143-1148
A novel bromide ion-selective PVC membrane sensor based on 2,3,10,11-tetraphenyl-1,4,9,12-tetraazacyclohexadeca-1,3,9,11-tetraene zinc(II)complex (I) as carrier has been developed. The electrode exhibited wide working concentration range 2.2 × 10−6 to 1.0 × 10−1 M and a limit of detection as 1.4 × 10−6 M with a Nernstian slope of 59.2 ± 0.5 mV per decade. The response time of electrode was 20 s over entire concentration range. The electrode possesses the advantages of low resistance, fast response and good selectivities for bromide over a variety of other anions and could be used in a pH range of 3.5–9.5. It was successfully used as an indicator electrode in the potentiometric titration of bromide ions with silver ion and also in the determination of bromide in real samples.  相似文献   

9.
Hu YJ  Tan SZ  Shen GL  Yu RQ 《Analytica chimica acta》2006,570(2):170-175
A novel optical sensor based on covalent immobilization for picric acid assay has been described. To improve the stability of the sensor, a terminal double bond was attached to the fluorescent compound, 3-amino-9-ethylcarbazole (AEC), via methacryloyl chloride. The resultant compound, 3-(N-methacryloyl) amino-9-ethylcarbazole (MAEC) was copolymerized with 2-hydroxypropyl methacrylate on surface-modified quartz glass plates by UV irradiation. The resulting optical sensor (optode membrane) was used to determine picric acid based on fluorescence quenching. It shows a linear response toward picric acid in the concentration range of 9.33 × 10−8 to 9.33 × 10−5 mol l−1, with rapid response, high stability and good selectivity to picric acid.  相似文献   

10.
A new modified carbon paste electrode (CPE) based on a recently synthesized Schiff base complex of Fe(III) as a suitable carrier for I ion is described. The electrode exhibits a super Nernstian slope of 71.0±0.3 mV per decade for I ion over a wide concentration range from 1.0×10−6 to 5.0×10−1 M, with a low detection limit of 6.5×10−7 M. It has a relatively fast response time, a satisfactory reproducibility and relatively long life time. The proposed sensor shows a fairly good selectivity toward I ion in comparison to other common anions. The potentiometric response is independent of the pH of the test solution in the pH range 3.5–10.0. Spectrophotometric studies confirmed the redox-type response mechanism of the electrode toward iodide ion. The proposed electrode was used as an indicator electrode in potentiometric titration of iodide ion.  相似文献   

11.
Trace amounts of nickel(II) can function as a trigger (=reaction initiator) in an autocatalytic reaction with the sodium sulfite/hydrogen peroxide system. Based on this finding, sub-μg L−1 levels of nickel(II) were determined by a time measurement using the autocatalytic reaction. The detection range using the above method was 10−9–10−5 M, the detection limit (3σ) was 8.1 × 10−10 M (0.047 μg L−1), and the relative standard deviation was 2.66% at nickel(II) concentration of 10−7 M (n = 7). This method was applied to length detection-flow injection analysis. The detection range for the flow injection analysis was 2 × 10−9–2 × 10−3 M. The detection limit (3σ) was 1.4 × 10−9 M (0.082 μg L−1), and the relative standard deviation was 1.86 at initial nickel(II) concentration of 10−6 M (n = 7).  相似文献   

12.
Nest-shaped cluster [MoOICu3S3(2,2′-bipy)2] (1) was synthesized by the treatment of (NH4)2MoS4, CuI, (n-Bu)4NI, and 2,2′-bipyridine (2,2′-bipy) through a solid-state reaction. It crystallizes in monoclinic space group P21/n, a=9.591(2) Å, b=14.820(3) Å, c=17.951(4) Å, β=91.98(2)°, V=2549.9(10) Å3, and Z=4. The nest-shaped cluster was obtained for the first time with a neutral skeleton containing 2,2′-bipy ligand. The non-linear optical (NLO) property of [MoOICu3S3(2,2′-bipy)2] in DMF solution was measured by using a Z-scan technique with 15 ns and 532 nm laser pulses. The cluster has large third-order NLO absorption and the third-order NLO refraction, its 2 and n2 values were calculated as 6.2×10−10 and −3.8×10−17 m2 W−1 in a 3.7×10−4 M DMF solution.  相似文献   

13.
A biomimetic potentiometric sensor for the specific recognition of methylphosphonic acid (MPA), the degradation product of nerve agents sarin, soman, VX, etc., was designed. This involves the preparation of MPA imprinted polymer particles and removal of the template by soxhlet extraction. Subsequently, the leached MIP particles were dispersed in 2-nitrophenyloctyl ether (plasticizer) and embedded in polyvinyl chloride matrix. The sensor responds to MPA in the concentration range 5 × 10−8 to 1 × 10−4 and 1 × 10−3 to 1 × 10−1 M with a detection limit of 5 × 10−8 M. The selectivity of the sensor has been tested with respect to chemical analogues such as phosphoric acid, sodium dihydrogen phosphate, organophosphorous pesticide and triazine herbicides. The utility of the sensor was tested for field monitoring of MPA in spiked ground water.  相似文献   

14.
A new, highly sensitive and simple kinetic method for the determination of thyroxine was proposed. The method was based on the catalytic effect of thyroxine on the oxidation of As(III) by Mn(III) metaphosphate. The kinetics of the reaction was studied in the presence of orthophosphoric acid. The reaction rate was followed spectrophotometrically at 516 nm. It was established that orthophosphoric acid increased the reaction rate and that the extent of the non-catalytic reaction was extremely small. A kinetic equation was postulated and the apparent rate constant was calculated. The dependence of the reaction rate on temperature was investigated and the energy of activation and other kinetic parameters were determined.

Thyroxine was determined under the optimal experimental conditions in the range 7.0 × 10−9 to 3.0 × 10−8 mol L−1 with a relative standard deviation up to 6.7% and a detection limit of 2.7 × 10−9 mol L−1. In the presence of 0.08 mol L−1 chloride, the detection limit decreased to 6.6 × 10−10 mol L−1. The proposed method was applied for the determination of thyroxine in tablets. The accuracy of the method was evaluated by comparison with the HPLC method.  相似文献   


15.
Huang F  Jin G  Liu Y  Kong J 《Talanta》2008,74(5):1435-1441
Phenylephrine (i.e. PHE) and chlorprothixene (i.e. CPT), two effective and important antipsychotic drugs with low redox activity, were found generating an irreversible anodic peak at about +0.89 V (vs. SCE) and +1.04 V in 0.05 M HAc–NaAc (pH 5.0) or NH2CH2COOH–HCl (pH 2.4) buffer solution at poly(4-aminobenzene sulfonic acid) modified glassy carbon electrode (i.e. poly(4-ABSA)/GC), respectively. Sensitive and quantitative measurement for them based on the anodic peaks was established under the optimum conditions. The anodic peak current was linear to PHE and CPT concentrations from 1 × 10−7 to 1.5 × 10−5 M and 2 × 10−6 to 4.5 × 10−5 M, the detection limits obtained were 1 × 10−8 and 1 × 10−7 M, separately. The modified electrode exhibited some excellent characteristics including easy regeneration, high stability, good reproducibility and selectivity. The method proposed was successfully applied to the determination of PHE and CPT in drug injections or tablets and proved to be reliable compared with ultraviolet spectrophotometry. The modified electrode was characterized by electrochemical methods.  相似文献   

16.
Chi Y  Xie J  Chen G 《Talanta》2006,68(5):1544-1549
The electrochemiluminescent (ECL) response of allopurinol was studied in aqueous media over a wide pH range (pH 2–13) using flow injection (FI) analysis. It was revealed that allopurinol itself had no ECL activity, but could greatly enhance the ECL of Ru(bpy)32+ in alkaline media giving rise to a sensitive FI-ECL response. The effects of experimental conditions including the mode of applied voltage signal, the potential of working electrode, pH value, the flow rate of carrier solution, and the concentration of Ru(bpy)32+ and allopurinol on the ECL intensity were investigated in detail. The most sensitive FI-ECL response of allopurinol was found at pH 12.0, where the FIA-ECL intensity showed a linear relationship with concentration of allopurinol in the range 1 × 10−8 mol L−1 to 5 × 10−7 mol L−1, and the detection limit was 5 × 10−9 mol L−1.  相似文献   

17.
Various amino acid derivatives of monascus pigments were synthesized. The effects of pigment derivatives on the pigment adsorption ratio, electrophoretic mobility (EPM) of bacterial cells, and antibacterial activity were investigated under varying conditions of pigment type, pigment concentration, pH, and ionic strength. Two hydrophobic and two hydrophilic derivatives were selected as model pigments. There was a close relationship between the antimicrobial activity and the pigment adsorption ratio. Against Escherichia coli, the hydrophobic l-Tyr and l-Phe derivatives (log P = 3.18 and 3.57) exhibited high antimicrobial activities (MIC = 8 and 16 mg/L) and high cellular adsorption ratios (9.6 and 10.9 mg/L). The hydrophilic l-Glu and l-Asn derivatives (log P = 1.40 and 0.47) exhibited low activities (MIC = 64 and 128 mg/L) and low adsorption ratios (4.7 and 4.0 mg/L). The electrophoretic mobility of 11 different bacteria varied between −1.93 × 10−8 and −1.19 × 10−8 m2 V−1 s−1 regardless of Gram+ or Gram. The l-Phe derivative showed low MIC values (high antimicrobial activities) against bacteria with a high electrophoretic mobility. A positive linearity between the pigment adsorption ratio and the electrophoretic mobility was established. When the four pigment derivatives were added to E. coli solutions, the electrophoretic mobility of cells in all cases sharply increased with an increasing pigment concentration. The mobility value was high for hydrophobic pigment derivatives in descending order of l-Phe (0.8 × 10−8 m2 V−1 s−1), l-Tyr (0.68 × 10−8 m2 V−1 s−1), l-Glu (0.46 × 10−8 m2 V−1 s−1), and l-Asn (0.44 × 10−8 m2 V−1 s−1). Additional adsorption of the hydrophobic derivatives probably occurred due to a hydrophobic interaction between the pigment and the pigment-coated cells. The electrophoretic mobility decreased gradually with an increasing pH and/or ionic strength with both addition and no addition of the pigment derivatives. The pattern of change of the pigment adsorption ratio under varying pH and/or ionic strength values was similar to the pattern for electrophoretic mobility.  相似文献   

18.
A lithium phthalocyanine radical and the analogous aluminum phthalocyanine radical were synthesized as part of an investigation of isostructural dopants. An improved synthesis of the free base of octa(pentoxy)phthalocyanine (H2Pc*) involves the reduction of 1,2-dicyano-4,5-dipentoxybenzene with hydroquinone. Deprotonation with lithium bis(trimethylsilyl)amide leads to the dilithium derivative Li2Pc* and subsequent oxidation with ferrocenium yields the radical LiPc*. Treatment of H2Pc* with Et2AlCl gives ClAlPc* and reduction with sodium amalgam yields AlPc*, the first reported aluminum phthalocyanine radical. In the solid state LiPc* and AlPc* are electrical conductors with pressed-pellet conductivities of 8 × 10−11 Ω−1 cm−1 and 5 × 10−7 Ω−1 cm−1, respectively.  相似文献   

19.
A simple, rapid and sensitive method for the determination of chromium(III) and total chromium using the simple dual T channels on glass chip with negative pressure pumping system and chemiluminescence (CL) detection is presented. The CL reaction was based on luminol oxidation by hydrogen peroxide in basic aqueous solution catalyzed by chromium(III). Total chromium in form of chromium(III) was achieved after chromium(VI) was completely reduced by acidic sodium hydrogen sulfite. Total chromium could then be determined with the same strategy as the chromium(III). The CL reagent was composed of 1.0 × 10−4 mol/L luminol, 1.0 × 10−2 mol/L hydrogen peroxide and 0.10 mol/L sodium bromide in 0.050 mol/L carbonate buffer (pH 11.00). The 1.0 × 10−2 mol/L ethylenediaminetetraacetic acid was added into the sample solution in order to improve the selectivity. Chromium(III) could be detected at a notably concentration of 1.6 × 10−16 mol/L and a linear calibration curve was obtained from 1.0 × 10−15 to 1.0 × 10−13 mol/L. The sample and CL reagent consumption were only 15 and 20 μL, respectively. The analysis time was less than 1 min per sample with the precision (%R.S.D.) was 4.7%. The proposed method has been applied successfully to the analysis of river water, mineral waters, drinking waters and tap water. Its performance was verified by the analysis of certified total chromium-reference materials and by recovery measurement on spiked synthetic seawater sample.  相似文献   

20.
A PVC membrane electrode based on bis-2-thiophenal propanediamine (TPDA) coated directly on graphite is described. The electrode exhibits a Nernstian response for Cu2+ over a very wide concentration range (1.0×10−1 to 6.0×10−8 M) with a detection limit of 3.0×10−8 M (2.56 ng ml−1). It has a fast response time and can be used for at least 2 months without any major deviation. The proposed sensor revealed very good selectivities for Cu2+ over a wide variety of other metal ions and could be used in the pH range of 3.0–7.0. It was successfully used for direct determination of copper in black tea and as an indicator electrode in potentiometric titration of copper ion.  相似文献   