首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
An adsorptive stripping voltammetric (AdSV) procedure for simultaneous determination of Ni(II) and Co(II) in the presence of nioxime as a complexing agent at an in situ plated lead film electrode was described. The Co(II) signal was enhanced by exploitation of the catalytic process in the presence of nitrite. Ni(II) and Co(II) signals are better separated than in the case of bismuth film electrodes. Calibration graphs for an accumulation time of 120 s are linear from 1 × 10−9 to 1 × 10−7 mol L−1 and from 1 × 10−10 to 5 × 10−9 mol L−1 for Ni(II) and Co(II), respectively. The proposed procedure was applied for Ni(II) and Co(II) determination in water certified reference materials.  相似文献   

2.
Li Liu  Jun-feng Song  Peng-fei Yu  Bin Cui 《Talanta》2007,71(5):1842-1848
A novel voltammetric method for the determination of β-d-glucose (GO) is proposed based on the reduction of Cu(II) ion in Cu(II)(NH3)42+–GO complex at lanthanum(III) hydroxide nanowires (LNWs) modified carbon paste electrode (LNWs/CPE). In 0.1 mol L−1 NH3·H2O–NH4Cl (pH 9.8) buffer containing 5.0 × 10−5 mol L−1 Cu(II) ion, the sensitive reduction peak of Cu(II)(NH3)42+–GO complex was observed at −0.17 V (versus, SCE), which was mainly ascribed to both the increase of efficient electrode surface and the selective coordination of La(III) in LNW to GO. The increment of peak current obtained by deducting the reduction peak current of the Cu(II) ion from that of the Cu(II)(NH3)42+–GO complex was rectilinear with GO concentration in the range of 8.0 × 10−7 to 2.0 × 10−5 mol L−1, with a detection limit of 3.5 × 10−7 mol L−1. A 500-fold of sucrose and amylam, 100-fold of ascorbic acid, 120-fold of uric acid as well as gluconic acid did not interfere with 1.0 × 10−5 mol L−1 GO determination.  相似文献   

3.
In this work, nickel hexacyanoferrate-modified electrode was developed to determine potassium ions in biodiesel by potentiometry. The modified electrodes exhibit a linear response to potassium ions in the concentration range of 4.0 × 10−5 to 1.0 × 10−2 mol L−1, with a detection limit of 1.9 × 10−5 mol L−1, and a near-Nernstian slope (53–55 mV per decade) at 25 °C. The method developed in this work was compared with flame photometry and the potassium concentration found in biodiesel showed that the modified electrode method gives results similar to those obtained by flame photometry.  相似文献   

4.
Singh AK  Mehtab S  Saxena P 《Talanta》2006,69(5):1143-1148
A novel bromide ion-selective PVC membrane sensor based on 2,3,10,11-tetraphenyl-1,4,9,12-tetraazacyclohexadeca-1,3,9,11-tetraene zinc(II)complex (I) as carrier has been developed. The electrode exhibited wide working concentration range 2.2 × 10−6 to 1.0 × 10−1 M and a limit of detection as 1.4 × 10−6 M with a Nernstian slope of 59.2 ± 0.5 mV per decade. The response time of electrode was 20 s over entire concentration range. The electrode possesses the advantages of low resistance, fast response and good selectivities for bromide over a variety of other anions and could be used in a pH range of 3.5–9.5. It was successfully used as an indicator electrode in the potentiometric titration of bromide ions with silver ion and also in the determination of bromide in real samples.  相似文献   

5.
Trace amounts of nickel(II) can function as a trigger (=reaction initiator) in an autocatalytic reaction with the sodium sulfite/hydrogen peroxide system. Based on this finding, sub-μg L−1 levels of nickel(II) were determined by a time measurement using the autocatalytic reaction. The detection range using the above method was 10−9–10−5 M, the detection limit (3σ) was 8.1 × 10−10 M (0.047 μg L−1), and the relative standard deviation was 2.66% at nickel(II) concentration of 10−7 M (n = 7). This method was applied to length detection-flow injection analysis. The detection range for the flow injection analysis was 2 × 10−9–2 × 10−3 M. The detection limit (3σ) was 1.4 × 10−9 M (0.082 μg L−1), and the relative standard deviation was 1.86 at initial nickel(II) concentration of 10−6 M (n = 7).  相似文献   

6.
A new, highly sensitive and simple kinetic method for the determination of thyroxine was proposed. The method was based on the catalytic effect of thyroxine on the oxidation of As(III) by Mn(III) metaphosphate. The kinetics of the reaction was studied in the presence of orthophosphoric acid. The reaction rate was followed spectrophotometrically at 516 nm. It was established that orthophosphoric acid increased the reaction rate and that the extent of the non-catalytic reaction was extremely small. A kinetic equation was postulated and the apparent rate constant was calculated. The dependence of the reaction rate on temperature was investigated and the energy of activation and other kinetic parameters were determined.

Thyroxine was determined under the optimal experimental conditions in the range 7.0 × 10−9 to 3.0 × 10−8 mol L−1 with a relative standard deviation up to 6.7% and a detection limit of 2.7 × 10−9 mol L−1. In the presence of 0.08 mol L−1 chloride, the detection limit decreased to 6.6 × 10−10 mol L−1. The proposed method was applied for the determination of thyroxine in tablets. The accuracy of the method was evaluated by comparison with the HPLC method.  相似文献   


7.
A novel copper(II) thiocyanate complex [Cu(im)2(NCS)2] 1 (im=imidazole) has been prepared and characterized by spectroscopic analysis and crystallographic method. This supramolecular compound exhibits a three-dimensional solid state structure constituted by N–HS hydrogen bonds and π–π stacking interactions. The compound in DMF solutions has a very strong third-order non-linear optical (NLO) behavior with absorption coefficient and refractive index 2=1.18×10−11 mw−1, n2=−9.00×10−16 m2w−1, respectively, and third-order NLO susceptibility χ(3) of 7.00×10−10 esu.  相似文献   

8.
Excitation of solutions of Fe(bipy)2(CN)2 by a 266-nm laser pulse produces a hydrated electron and the oxidized complex, Fe(bipy)2 (CN)2+, in the primary photochemical step, in homogeneous aqueous solution as well as in aqueous solutions containing cetyltrimethylammonium bromide (CTAB) or sodium dodecyl sulfate (SDS) micelles. In all cases nascent hydrated electrons react with ground state Fe(bipy)2(CN)2 to form Fe(bipy)2(CN)2, and comparison of the decay constants in the three media (H2O: k = 2.8 × 1010 M−1 s−1; CTAB: k = 2.9 × 1010 M−1 s−1; SDS: k = 5.5 × 109 M−1 s−1), shows that the reaction is essentially unaffected by CTAB micelles but is much slower in SDS solution. Similar micellar effects were found for the back reaction between eaq and Fe(bpy)2(CN)2+. Rate constants for the scavenging of the photogenerated hydrated electrons by methyl viologen (MV2+) cations and NO3 anions were measured in the three systems, and the results indicate that for scavenging by MV2+ the rate constants are decreased in the micelle systems (k in H2O, 8.4 × 1010; CTAB, 3.5 × 1010 and SDS, 1.58 × 1010 M−1 s−1), whereas for NO3 the CTAB micelle decreases while the SDS micelle enhances the scavenging compared to water solution (k in H2O, 8.3 × 109; CTAB, 7 × 108; and SDS, 2.05 × 1010 M−1 s−1). For the comproportionation reaction between Fe(bipy)2(CN)2+ and Fe(bipy)2(CN)2 both micelles reduce the rate (k in H2O, 3.3 × 1010; CTAB, 2.3 × 1010; and SDS, 1.05 × 1010 M−1s−1), but while the reaction of Fe(bipy)2(CN)2+ with MV+ is increased in CTAB compared to water, it is slowed in SDS (k in H2O, 2.4 × 1010; CTAB, 8.9 × 1010; and SDS, 1.8 × 1010 M−1s−1). All effects observed in these microheterogeneous systems can be uniformly interpreted in terms of Coulombic interactions between the actual reactants and the charged surface of the micelles.  相似文献   

9.
Zhang BT  Zhao L  Lin JM 《Talanta》2008,74(5):1154-1159
Based on the chemiluminescence (CL) phenomena of folic acid in peroxomonosulfate-cobalt(II) system, a rapid and sensitive CL method was developed for determination of folic acid in pharmaceutical preparations and its urinary metabolism processes. Under the optimum conditions, the relative CL intensity was linear over the concentration ranging from 10−9 to 8 × 10−7 mol L−1 (R2 = 0.9991) with a detection limit as low as 6 × 10−10 mol L−1 (S/N = 3) and relative standard deviation was 2.63% for 2 × 10−8 mol L−1 folic acid (n = 11). This method has been successfully applied to the determination of folic acid in tablets and human urine. The blank CL emission was yielded owing to the formation of singlet oxygen molecular pair from the quenching experiment of 1,4-diazabicyclo[2.2.2]octane, and pterine-6-carboxylic acid might be the degradation intermediate in this system and it also acts an energy acceptor and sensitizes the chemiluminescence based on the studies of the CL and fluorescence spectra.  相似文献   

10.
A new PVC membrane electrode for Zn2+ ions based on tetra(2-aminophenyl) porphyrin (TAPP) as membrane carrier is prepared. The sensor exhibits a linear stable response over a wide concentration range (5.0×10−5 to 1.0×10−1 M) with a slope of 26.5 mV/decade and a limit of detection 3.0×10−5 M (1.96 ppm). It has a response time of about l0 s and can be used for at least 8 months without any divergence in potential. The propose membrane sensor revealed good selectivities for Zn2+ over a wide variety of other metal ions and can be used in pH range of 3.0–6.0. It was successfully applied to the direct determination of zinc in a pharmaceutical sample and also as an indicator electrode in potentiometric titration of Zn2+ ions.  相似文献   

11.
Antigen I/II can be found on streptococcal cell surfaces and is involved in their interaction with salivary proteins. In this paper, we determine the adsorption enthalpies of salivary proteins to Streptococcus mutans LT11 and S. mutans IB03987 with and without antigen I/II, respectively, using isothermal titration calorimetry. In addition, protein adsorption to the cell surfaces was determined spectrophotometrically. S. mutans LT11 with antigen I/II, yielded a much higher, exothermic adsorption enthalpy at pH 6.8 (ranging from −2073 × 10−9 to −31707 × 10−9 μJ per bacterium) when mixed with saliva than did S. mutans IB03987 (−165 × 10−9 to −1107 × 10−9 μJ per bacterium) at all bacterial concentrations studied (5 × 109, 5 × 108, and 5 × 107 ml−1), largest effects per bacterium being observed for the lowest concentration. However, the enthalpy of salivary protein adsorption to S. mutans LT11 became smaller at pH 5.8. Adsorption isotherms for the S. mutans LT11 showed considerable protein adsorption at pH 6.8 (1.2–2.1 mg/m2), that decreased only slightly at pH 5.8 (1.1–1.6 mg/m2), with the largest amount adsorbed at the lowest bacterial concentration. This suggests that the protein(s) in the saliva with the strongest affinity for antigen I/II is (are) readily depleted from saliva. In conclusion, antigen I/II surface proteins on S. mutans play a determinant role in adsorption of salivary proteins through the creation of enthalpically favorable adsorption sites.  相似文献   

12.
Chi Y  Xie J  Chen G 《Talanta》2006,68(5):1544-1549
The electrochemiluminescent (ECL) response of allopurinol was studied in aqueous media over a wide pH range (pH 2–13) using flow injection (FI) analysis. It was revealed that allopurinol itself had no ECL activity, but could greatly enhance the ECL of Ru(bpy)32+ in alkaline media giving rise to a sensitive FI-ECL response. The effects of experimental conditions including the mode of applied voltage signal, the potential of working electrode, pH value, the flow rate of carrier solution, and the concentration of Ru(bpy)32+ and allopurinol on the ECL intensity were investigated in detail. The most sensitive FI-ECL response of allopurinol was found at pH 12.0, where the FIA-ECL intensity showed a linear relationship with concentration of allopurinol in the range 1 × 10−8 mol L−1 to 5 × 10−7 mol L−1, and the detection limit was 5 × 10−9 mol L−1.  相似文献   

13.
Huang F  Jin G  Liu Y  Kong J 《Talanta》2008,74(5):1435-1441
Phenylephrine (i.e. PHE) and chlorprothixene (i.e. CPT), two effective and important antipsychotic drugs with low redox activity, were found generating an irreversible anodic peak at about +0.89 V (vs. SCE) and +1.04 V in 0.05 M HAc–NaAc (pH 5.0) or NH2CH2COOH–HCl (pH 2.4) buffer solution at poly(4-aminobenzene sulfonic acid) modified glassy carbon electrode (i.e. poly(4-ABSA)/GC), respectively. Sensitive and quantitative measurement for them based on the anodic peaks was established under the optimum conditions. The anodic peak current was linear to PHE and CPT concentrations from 1 × 10−7 to 1.5 × 10−5 M and 2 × 10−6 to 4.5 × 10−5 M, the detection limits obtained were 1 × 10−8 and 1 × 10−7 M, separately. The modified electrode exhibited some excellent characteristics including easy regeneration, high stability, good reproducibility and selectivity. The method proposed was successfully applied to the determination of PHE and CPT in drug injections or tablets and proved to be reliable compared with ultraviolet spectrophotometry. The modified electrode was characterized by electrochemical methods.  相似文献   

14.
Electrochemical studies of famotidine were carried out using voltammetric techniques: cyclic voltammetry, linear sweep and square wave adsorptive stripping voltammetry. The dependence of the current on pH, buffer concentration, nature of the buffer, and scan rate was investigated. The best results for the determination of famotidine were obtained in MOPS buffer solution at pH 6.7. This electroanalytical procedure enabled to determine famotidine in the concentration range 1 × 10−9–4 × 10−8 mol L−1 by linear sweep adsorptive stripping voltammetry (LS AdSV) and 5 × 10−10–6 × 10−8 mol L−1 by square wave adsorptive stripping voltammetry (SW AdSV). Repeatability, precision and accuracy of the developed methods were checked. The detection and quantification limits were found to be 1.8 × 10−10 and 6.2 × 10−10 mol L−1 for LS AdSV and 4.9 × 10−11 and 1.6 × 10−10 mol L−1 for SW AdSV, respectively. The method was applied for the determination of famotidine in urine.  相似文献   

15.
Ohura H  Imato T  Yamasaki S 《Talanta》1999,49(5):1383-1015
A rapid potentiometric flow injection technique for the simultaneous determination of oxychlorine species such as ClO3–ClO2 and ClO3–HClO has been developed, using both a redox electrode detector and a Fe(III)–Fe(II) potential buffer solution containing chloride. The analytical method is based on the detection of a large transient potential change of the redox electrode due to chlorine generated via the reaction of the oxychlorine species with chloride in the potential buffer solution. The sensitivities to HClO and ClO2 obtained by the transient potential change were enhanced 700–800-fold over that using an equilibrium potential. The detection limit of the present method for HClO and ClO2 is as low as 5×10−8 M with use of a 5×10−4 M Fe(III)–1×10−3 M Fe(II) buffer containing 0.3 M KCl and 0.5 M H2SO4. On the other hand, sensitivity to ClO3 was low when a potential buffer solution containing 0.5 M H2SO4 was used, but could be increased largely by increasing the acidity of the potential buffer. The detection limit for ClO3 was 2×10−6 M with the use of a 5×10−4 M Fe(III)–1×10−3 M Fe(II) buffer containing 0.3 M KCl and 9 M H2SO4. By utilizing the difference in reactivity of oxychlorine species with chloride in the potential buffer, a simultaneous determination method for a mixed solution of ClO3–ClO2 or ClO3–HClO was designed to detect, in a timely manner, a transient potential change with the use of two streams of potential buffers which contain different concentrations of sulfuric acid. Analytical concentration ranges of oxychlorine species were 2×10−5–2×10−4 M for ClO3, and 1×10−6–1×10−5 M for HClO and ClO2. The reproducibility of the present method was in the range 1.5–2.3%. The reaction mechanism for the transient potential change used in the present method is also discussed, based on the results of batchwise experiments. The simultaneous determination method was applied to the determination of oxychlorine species in a tap water sample, and was found to provide an analytical result for HClO, which was in good agreement with that obtained by the o-tolidine method and to provide a good recovery for ClO3 added to the sample.  相似文献   

16.
A sensitive and rapid electrochemical method was developed for the determination of telmisartan based on the enhancement effect of sodium dodecyl benzene sulfonate (SDBS). In 0.1 mol L−1 HClO4 and in the presence of 7.5 × 10−5 mol L−1 SDBS, a well-defined and sensitive oxidation peak was observed for telmisartan at the acetylene black (AB) paste electrode. However, the oxidation peak is poor-shaped and the peak current is very low in the absence of SDBS, suggesting that SDBS shows obvious enhancement effect for the determination of telmisartan. After all the experimental parameters were optimized, a sensitive and simple electrochemical method was developed for determining telmisartan. The oxidation peak current is proportional to the concentration of telmisartan over the range from 2.5 × 10−7 to 2.0 × 10−5 mol L−1. The detection limit is 7.5 × 10−8 mol L−1 after 2 min of accumulation. This new voltammetric method was successfully used to detect telmisartan in drugs.  相似文献   

17.
A series of fluorenyl-containing sulfonated poly(aryl ether ether ketone ketone)s (SPFEEKK) were synthesized via aromatic nucleophilic substitution polymerization. The sulfonation content (SC) was controlled by the feed ratios of sulfonated and nonsulfonated monomers. Flexible and strong membranes in the sulfonic acid form were obtained from cast membranes in the sodium salt forms by treatment with acid. The thermal properties, water uptake, swelling ratio, water state, oxidative stability, proton conductivity and methanol permeability were investigated. All the polymers had proton conductivities greater than 1 × 10−2 S/cm at room temperature, and the conductivity values of m-SPFEEKK-80 and p-SPFEEKK-80 were up to 1.86 × 10−1 and 1.78 × 10−1 S/cm at 100 °C. This series of polymers also possessed good dimensional stability in water and low methanol crossover.  相似文献   

18.
Güçlü K  Sözgen K  Tütem E  Ozyürek M  Apak R 《Talanta》2005,65(5):1226-1232
The proposed method for ascorbic acid (Vitamin C) (AA) determination is based on the oxidation of AA to dehydroascorbic acid with a Cu(II)-2,9-dimethyl-1,10-phenanthroline (neocuproine (Nc)) reagent in ammonium acetate-containing medium at pH 7, where the absorbance of the formed bis(Nc)-copper(I) chelate is measured at 450 nm. This chelate was formed immediately and the apparent molar absorptivity for AA was found to be 1.60 × 104 dm3 mol−1 cm−1. Beer's law was obeyed between 8.0 × 10−6 and 8.0 × 10−5 M concentration range. The relative standard deviation for 90 μg AA was 3%. The Cu(II)-Nc reagent is a milder and therefore more selective oxidant than the conventional Fe(III)-1,10-phenanthroline (phen) reagent used for the same assay. This feature makes the proposed method superior for real samples such as fruit juices containing weak reductants such as citrate, oxalate and tartarate that otherwise produce positive errors in the Fe(III)-phen method when equilibrium is achieved. The developed method was applied to a number of commercial fruit juices, pharmaceutical preparations containing Vitamin C, and red wine. The meta-bisulfite content of wine was removed with an anion exchanger at pH 3 prior to analysis, and a difference extractive–spectrophotometric method of AA assay in wine was developed so as to suppress the interferences caused by wine anthocyanins and polyphenols. The findings of the developed method for fruit juices and pharmaceuticals were also statistically compared with those of HPLC so as to establish it as a reliable novel method.  相似文献   

19.
A lithium phthalocyanine radical and the analogous aluminum phthalocyanine radical were synthesized as part of an investigation of isostructural dopants. An improved synthesis of the free base of octa(pentoxy)phthalocyanine (H2Pc*) involves the reduction of 1,2-dicyano-4,5-dipentoxybenzene with hydroquinone. Deprotonation with lithium bis(trimethylsilyl)amide leads to the dilithium derivative Li2Pc* and subsequent oxidation with ferrocenium yields the radical LiPc*. Treatment of H2Pc* with Et2AlCl gives ClAlPc* and reduction with sodium amalgam yields AlPc*, the first reported aluminum phthalocyanine radical. In the solid state LiPc* and AlPc* are electrical conductors with pressed-pellet conductivities of 8 × 10−11 Ω−1 cm−1 and 5 × 10−7 Ω−1 cm−1, respectively.  相似文献   

20.
A μ-bis(tridentate) ligand named 2-phenyl-1,3-bis[3′-aza-4′-(2′-hydroxyphenyl)-prop-4-en-1′-yl]-1,3-imidazolidine (I) has been synthesized and scrutinized to develop iron(III)-selective sensors. The addition of sodium tetraphenyl borate and various plasticizers, viz., chloronaphthalene, dioctylphthalate, o-nitrophenyl octyl ether and dibutylphthalate has been used to substantially improve the performance of the sensors. The membranes of various compositions of the ligand were investigated and it was found that the best performance was obtained for the membrane of composition (I) (10 mg):PVC (150 mg):chloronaphthalene (200 mg):sodium tetraphenyl borate (9 mg). The sensor showed a linear potential response to iron(III) over wide concentration range 6.3 × 10−6 to 1.0 × 10−1 M (detection limit 5.0 × 10−6 M) with Nernstian slope (20.0 mV/decade of activity) between pH 3.5 and 5.5 with a quick response time of 15 s. The potentiometric selectivity coefficient values as determined by match potential method (MPM) indicate excellent selectivity for Fe3+ ions over interfering cations. The sensor exhibits adequate life of 2 months with good reproducibility. The sensor could be used in direct potentiometry.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号