首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 765 毫秒
1.
A mid-infrared carbon monoxide (CO) sensor system based on a dual-channel differential detection method was developed using a broadband light source in the 4.60 µm wavelength region and a single-reflection spherical optical chamber with ∼0.373 m absorption path length. CO detection was realized by targeting the wideband strong absorption lines within 4.55–4.65 µm. A dual-channel pyroelectric detector as well as a self-developed digital signal processor (DSP) based orthogonal lock-in amplifier was employed to process CO sensing signal. A minimum detection limit of ∼0.5 ppm in volume (ppmv) was achieved with a measurement time of 6 s, based on an Allan deviation analysis of the sensor system. The response time (1000  0 ppmv) was determined to be ∼7 s for the CO sensor operation. Due to the characteristics of low detection limit, fast response time and high cost performance, the proposed sensor has relatively good prospect in coal-mining operation.  相似文献   

2.
A miniature mid-infrared (mid-IR) methane (CH4) sensor system was developed by employing a wide-band wire-source and a semi-ellipsoid multi-pass gas cell. A dual-step differential method instead of the traditional one-step differential method was adopted by this sensor to tune measuring range/zero point and to suppress the additive/multiplicative noise. This method included a first subtraction operation between the two output signals (including a detection signal and a reference signal) from the dual-channel detector and a second subtraction operation on the amplitudes of the first-subtraction signal and the reference signal, followed by a ratio operation between the amplitude of the second-subtraction signal and the reference signal. Detailed experiments were performed to assess the performance of the sensor system. The detection range is 0–50 k ppm, and as the concentration gets larger than 12 k ppm, the relative detection error falls into the range of −3% to +3%. The Allan deviation is about 4.65 ppm with an averaging time of 1 s, and such value can be further improved to 0.45 ppm with an averaging time of 124 s. Due to the cost-effective incandescence wire-source, the small-size ellipsoid multi-pass gas cell and the miniature structure of the sensor, the developed standalone device shows potential applications of CH4 detection under coal-mine environment.  相似文献   

3.
We developed a very sensitive high-frequency carrier-type thin film sensor with a sub-pT resolution using a transmission line. The sensor element consists of Cu conductor with a meander pattern (20 mm in length, 0.8 mm in width, and 18 μm in thickness), a ground plane, and amorphous CoNbZr film (4 μm in thickness). The amplitude modulation technique was employed to enhance the magnetic field resolution for measurement of the high-frequency field (499 kHz), a resolution of 7.10×10?13 T/Hz1/2 being achieved, when we applied an AC magnetic field at 499 kHz. The phase detection technique was applied for measurement of the low frequency field (around 1 Hz). A small phase change was detected using a dual mixer time difference method. A high phase change of 130°/Oe was observed. A magnetic field resolution of 1.35×10?12 T/Hz1/2 was obtained when a small AC field at 1 Hz was applied. We applied the sensor for magnetocardiogram (MCG) measurement using the phase detection technique. We succeeded in measuring the MCG signal including typical QRS and T waves, and compared the MCG with a simultaneously obtained conventional electrocardiogram (ECG) signal.  相似文献   

4.
A high sensitivity sensor, combining a multipass cell and wavelength modulation spectroscopy in the near infrared spectral region was designed and implemented for trace gas detection. The effective length of the multipass cell was about 290 meters. The developed spectroscopic technique demonstrates an improved sensitivity of methane in ambient air and a relatively short detection time compared to previously reported sensors. Home-built electronics and software were employed for diode laser frequency modulation, signal lock-in detection and processing. A dual beam scheme and a balanced photo-detector were implemented to suppress the intensity modulation and noise for better detection sensitivity. The performance of the sensor was evaluated in a series of measurements ranging from three hours to two days. The average methane concentration measured in ambient air was 2.01 ppm with a relative error of ± 2.5%. With Allan deviation analysis, it was found that the methane detection limit of 1.2 ppb was achieved in 650 s. The developed sensor is compact and portable, and thus it is well suited for field measurements of methane and other trace gases.  相似文献   

5.
The present paper introduces a facile and cost-effective route for the direct dispersion of multi-walled carbon nanotubes (MWCNTs) in DNA solution. Their application in detecting Escherichia coli O157:H7 using DNA biosensor was demonstrated. The dispersion state of the MWCNTs was characterized via UV–Vis spectroscopy, transmission electron microscopy, and field emission scanning electron microscopy. The interaction between DNA sequence and the MWCNTs was investigated using Raman spectroscopy and Fourier transform infrared spectroscopy. As-obtained MWCNT solution was used in the preparation of DNA sensor. Results revealed that the developed DNA sensor can detect a DNA target as low as 1 nM in a buffer solution. The sensitivity of the DNA sensor reached approximately 0.19 nM/mV. The effect of dispersion parameters, including pH values, DNA concentration, ion strength, and sonication time, on sensor response was also studied. The DNA sensor can respond well to 120 min of sonication time, a pH value of 9, and 20 μM of DNA sequence concentration. The results of the present study showed a potential application of the DNA sensor in the detection of Escherichia coli O157:H7.  相似文献   

6.
A compact system for methane sensing based on the Quartz-Enhanced Photoacoustic Spectroscopy technique has been developed. This development has been taken through two versions which were based respectively on a Fabry Perot quantum wells diode laser emitting at 2.3 μm, and on a quantum wells distributed feedback diode laser emitting at 3.26 μm. These lasers emit near room temperature in the continuous wave regime. A spectrophone consisting of a quartz tuning fork and one steel microresonator was used. Second derivative wavelength modulation detection was used to perform low methane concentration measurements. The sensitivity and the linearity of the QEPAS sensor were studied. A normalized noise equivalent absorption coefficient of 7.26 × 10−6 cm−1 W/Hz1/2 was achieved. This corresponds to a detection limit of 15 ppmv for 12 s acquisition time.  相似文献   

7.
The fabrication method and the pyroelectric response of a single element infrared sensor based lead zirconate titanate (PZT) particles and polyvinylidene fluoride P(VDF-TrFE) copolymer composite thick film is reported in this paper. A special thermal insulation structure, including polyimide (PI) thermal insulation layer and thermal insulation tanks, was used in this device. The thermal insulation tanks were fabricated by laser micro-etching technique. Voltage responsivity (RV), noise voltage (Vnoise), noise equivalent power (NEP), and detectivity (D*) of the PZT/P(VDF-TrFE) based infrared sensor are 1.2 × 103 V/W, 1.25 × 106 V Hz1/2, 1.1 × 10−9 W and 1.9 × 108 cm Hz1/2 W−1 at 137.3 Hz modulation frequency, respectively. The thermal time constant of the infrared sensor τT was about 15 ms. The results demonstrate that the composite infrared sensor show a high detectivity at high chopper frequency, which is an essential advantage in infrared detectors and some other devices.  相似文献   

8.
《Current Applied Physics》2010,10(2):370-372
In this work, the methanol sensors were fabricated by using Pt dot catalyst electrode and the level of electrochemical response was analyzed. This kind of sensors can be applicable to sensing the methanol concentration in real-time. When we measured the methanol sensor with 5 nm of Pt dot, we could get 2.00 × 10−6, 3.06 × 10−6 and 6.25 × 10−6 A of electric current value for the methanol concentration of 1, 2 and 3 mole, respectively. The measured voltage was 1 V. To optimize the sensitivity level of Pt dot catalyst electrode, the electrodes were made in H-grid shape. The distance between electrode branches was designed to be 80, 150 and 300 μm, respectively. When we measured the electric current–voltage characteristics of methanol sensor with 2 M of methanol, it was 3.06 × 10−6, 2.02 × 10−6 and 1.50 × 10−6 A, for 80, 150 and 200 μm, respectively. Thus it is suggested that more efficient response of methanol sensing is possible when the distance between electrodes is reduced.  相似文献   

9.
A portable near-infrared (NIR) CH4 detection sensor based on a distributed feedback (DFB) laser modulated at 1.654 μm is experimentally demonstrated. Intelligent temperature controller with an accuracy of −0.07 to +0.09 °C as well as a scan and modulation module generating saw-wave and cosine-wave signals are developed to drive the DFB laser, and a cost effective lock-in amplifier used to extract the second harmonic signal is integrated. Thorough experiments are carried out to obtain detection performances, including detection range, accuracy, stability and the minimum detection limit (MDL). Measurement results show that the absolute detection error relative to the standard value is less than 7% within the range of 0–100%, and the MDL is estimated to be about 11 ppm under an absorption length of 0.2 m and a noise level of 2 mVpp. Twenty-four hours monitoring on two gas samples (0.1% and 20%) indicates that the absolute errors are less than 7% and 2.5%, respectively, suggesting good long term stability. The sensor reveals competitive characteristics compared with other reported portable or handheld sensors. The developed sensor can also be used for the detection of other gases by adopting other DFB lasers with different center-wavelength using the same hardware and slightly modified software.  相似文献   

10.
In the present paper, a laser-coupled optical fiber is introduced for pH sensing of Methyl red solution in the Ethanol solvent. Then it is modified for corrosion detection when it was placed inside a corrosive solution. Second-harmonic (SH) radiation of a microchip Q-switched pulsed Nd:YAG laser operating at λ=532 nm is generated via KTP nonlinear crystal, and it is launched into the fabricated fiber sensor. The provided evanescent field is absorbed by the surrounding environment in the sensing region, and the output intensity of the absorbed laser beam is monitored and recorded in the presence of the different kind of solvents and corrosive solutions. To increase the sensitivity of the pH sensor the fiber-optic probe is coiled and fixed on a Poly Propylene (PP) mount with 6 cm diameter and 10 cm long. The fabricated sensor is then calibrated for pH measurement of unknown media. For corrosion detection, a spin motor is used to uniformly coat a small portion of the fiber designed as U-shaped after its clad was removed by a simple chemical method. It is then electroplated by a very thin Fe–C film to form a corrosion sensor. It is observed that while the concentration of the NH4Cl solution is changed from 0.068 to 0.125 mol/l and its pH from zero to 14, the output intensity of the launched laser is increased due to the Fe–C film corrosion.  相似文献   

11.
The paper proposes a readout circuit architecture with adjustable integration time for dual-band infrared detectors. The readout circuit uses direct injection to be combined with a capacitive trans-impedance amplifier. The amplifier is sharing between two pixels to reduce the complexity of the readout circuit. The proposed device reduces power consumption and area overhead compared to traditional structures. An experimental chip was fabricated using the TSMC 0.35 μm 2P4 M 5 V process. The resulting unit pixel layout area is 40 μm × 40 μm with input photocurrent ranging from 0.11 pA to 50 nA. CTIA mode is applicable from 0.11 pA to 10 nA, while DI mode is applicable from 3.3 pA to 50 nA. The maximum operating frequency of the chip are 4 MHz. The CTIA output swing is 1.2 V, the DI output swing is 2 V. The signal to noise ratio of the readout circuit is 65 dB and power consumption is less than 9.6 mW.  相似文献   

12.
Experiments on resonator micro-optic gyro (RMOG) with a digital proportional integral (PI) feedback scheme are performed. In this experimental setup, the key rotation sensing element is a polarization maintaining silica waveguide ring resonator (WRR) with a ring length of 7.9 cm and a diameter of 2.5 cm. A good linearity of 0.0015% over a wide range of ± 2 × 104 °/s can be achieved for the RMOG theoretically. The optimal digital PI feedback scheme is adopted in the frequency servo loop to reduce the reciprocal frequency fluctuations due to the WRR resonance frequency and laser frequency drifts. Residual equivalent input fluctuation can be reduced as low as 0.03 °/s/√Hz based on the optimal digital PI feedback scheme, which is close to the shot noise limited spectral density 0.02 °/s/√Hz of the RMOG with the input optical power of 0.2 mW. Relationship between RMOG output signal and angular rate is obtained from ± 0.1 °/s to ± 5 °/s. The standard deviation of the residuals between RMOG output results and linear fit curve is 0.066 °/s. For an integration of the processing circuit, all the processing circuit is implemented by a field programmable gate array (FPGA) instead of instruments. The output of this digitalized RMOG is obtained over a range of ± 550 °/s. The linearity of this digitalized RMOG is 0.0169%.  相似文献   

13.
A mini eye-safe KTiAsO4 intracavity optical parametric oscillator (IOPO) employing the shared cavity configuration and driven by a diode-end-pumped composite Nd:YAG/Cr4+:YAG laser is demonstrated in this paper. Under an incident laser diode power of 11 W, a maximum average output power of 424 mW at 1534 nm was obtained. The corresponding signal pulse width and repetition rate were 1.2 ns and 16.7 kHz, respectively. The fluctuation of the average signal output power over long-term operation was found to be ±3.0%. A theoretical model for the compact IOPO was also presented in this paper.  相似文献   

14.
To see improvements in the imaging performance near biomaterial implants we assessed a multispectral fully phase-encoded turbo spin-echo (ms3D-PE-TSE) sequence for artifact reduction capabilities and scan time efficiency in simulation and phantom experiments.For this purpose, ms3D-PE-TSE and ms3D-TSE sequences were implemented to obtain multispectral images (± 20 kHz) of a cobalt-chromium (CoCr) knee implant embedded in agarose. In addition, a knee implant computer model and the acquired ms3D-PE-TSE images were used to investigate the possibilities for scan time acceleration using field-of-view (FOV) reduction for off-resonance frequency bins and compressed sensing reconstructions of undersampled data. Both acceleration methods were combined to acquire a + 10 kHz frequency bin in a second experiment.The obtained ms3D-PE-TSE images showed no susceptibility related artifacts, while ms3D-TSE images suffered from hyper-intensity artifacts. The limitations of ms3D-TSE were apparent in the far off-resonance regions (±[10–20] kHz) located close to the implant. The scan time calculations showed that ms3D-PE-TSE can be applied in a clinically relevant timeframe (~ 12 min), when omitting the three central frequency bins. The feasibility of CS acceleration for ms3D-PE-TSE was demonstrated using retrospective reconstructions before combining CS and rFOV imaging to decrease the scan time for the + 10 kHz frequency bin from ~ 10.9 min to ~ 3.5 min, while also increasing the spatial resolution fourfold. The temporally resolved signal of ms3D-PE-TSE proved to be useful to decrease the intensity ripples after sum-of-squares reconstructions and increase the signal-to-noise ratio.The presented results suggest that the scan time limitations of ms3D-PE-TSE can be sufficiently addressed when focusing on signal acquisitions in the direct vicinity of metal implants. Because these regions cannot be measured with existing multispectral methods, the presented ms3D-PE-TSE method may enable the detection of inflammation or (pseudo-)tumors in locations close to the implant.  相似文献   

15.
A new characterization of Lophine as a sensitive layer to measure Nitrate in drinking water is presented in this paper. The characterization was performed with a standard slide and a standard multimode fiber coated with a Lophine sensitive layer (2,4,5-Triphenylimidazol (C21H16N2)). Spectral characterization has been conducted in the wavelength range from 300 to 1100 nm. We have demonstrated that Lophine can be used as a fiber sensor for the detection of Nitrate in drinking water. The sensing properties of the fiber sensor were analyzed at room temperature. Successful results were achieved when sensing Nitrate in the range between 1 mg/l and 70 mg/l. The response time was 20 ms and the recovery time was 40 ms.  相似文献   

16.
A resonant photoacoustic cell intended for laser-spectroscopy gas sensing is represented. This cell is a miniature imitation of a macro-scale banana-shaped cell developed previously. The parameters, which specify the cavity shape, are chosen so as not only to provide optimal cell operation at a selected acoustic resonance but also to reduce substantially the cell sizes. A miniaturized prototype cell (the volume of acoustic cavity of ∼5 mm3) adapted to the narrow diffraction-limited beam of near-infrared laser is produced and examined experimentally. The noise-associated measurement error and laser-initiated signals are studied as functions of modulation frequency. The background signal and the useful response to light absorption by the gas are analyzed in measurements of absorption for ammonia in nitrogen flow with the help of a pigtailed DFB laser diode oscillated near a wavelength of 1.53 μm. The performance of prototype operation at the second longitudinal acoustic resonance (the resonance frequency of ∼32.9 kHz, Q-factor of ∼16.3) is estimated. The noise-limited minimal detectable absorption normalized to laser-beam power and detection bandwidth is ∼8.07 × 10−8 cm−1 W Hz−1/2. The amplitude of the background signal is equivalent to an absorption coefficient of 2.51 × 10−5 cm−1. Advantages and drawbacks of the cell prototype are discussed. Despite low absorption-sensing performance, the produced miniaturized cell prototype shows a good capability of gas-leak detection.  相似文献   

17.
We propose an efficient approach to develop large-range liquid level sensors based on an extrinsic Fabry–Perot optical fibre interferometer with an all fused-silica structure and CO2 laser heating fusion bonding technology. The sensor exhibits signatures of a high sensitivity of 5.3 nm/kPa (36.6 nm/psi), a resolution of 6.8 Pa (9.9×10−4 psi) and an extreme low temperature dependence of 0.013 nm/°C. As a result, a high resolution of the water level measurement of approximately 0.7 mm on the length scale of 5 m and small errors of the water pressure measurement induced by the temperature dependence within 0.0025 kPa/°C (0.00036 psi/°C, water level 0.25 mm/°C) are achieved, thus providing useful applications for the detection of the large-range liquid level in harsh environments.  相似文献   

18.
In this paper, two hybrid multimode/single mode fiber FabryPérot (FP) cavities were compared. The cavities fabricated by chemical etching are presented as high temperature and strain sensors. In order to produce this FP cavity a single mode fiber was spliced to a graded index multimode fiber with 62.5 μm core diameter. The FabryPérot cavities were tested as a high temperature sensor in the range between room temperature and 700 °C and as strain sensors. A reversible shift of the interferometric peaks with temperature allowed to estimate a sensitivity of 0.75 ± 0.03 pm/°C and 0.98 ± 0.04 pm/°C for the sensor A and B respectively. For strain measurement sensor A demonstrated a sensitivity of 1.85 ± 0.07 pm/μ? and sensor B showed a sensitivity of 3.14 ± 0.05 pm/μ?. The sensors demonstrated the feasibility of low cost fiber optic sensors for high temperature and strain.  相似文献   

19.
This paper proposes a solution to the excessive area penalty associated with traditional buffer direct injection (BDI) for single pixel. The proposed solution reduces the area and power consumption of BDI to combine the direct injection (DI) within a shared architecture, while a dual-mode readout circuit expands the functionality and performance of the array readout circuit of infrared sensor. An experimental array of 10 × 8 readout circuits was fabricated using TSMC 2P4M 0.35 μm 5 V technology. Measurements were obtained using a main clock with a frequency of 3 MHz and power consumption of 9.94 mW. The minimum input current was 119 pA in BDI and 1.85 pA in DI. The signal swing was 2 V, the root mean square noise voltage was 1.84 mV, and the signal-to-noise ratio was 60 dB. This approach is applicable to mid- and long-band sensors to increase injection efficiency and resolution.  相似文献   

20.
This paper describes the performance of an amperometric sensor for thiol detection. The sensor was designed based on a Prussian blue (PB) glassy carbon (GC) electrode. Prussian blue was chemically deposited onto the glassy carbon electrode by a dropletting method. Thiol compounds were detected at the PB-modified GC electrode by electrooxidation. A PB-modified glassy carbon electrode was applied to detect thiol at an applied potential of +0.25 V versus the Ag/AgCl electrode. This sensor showed an excellent electrochemical response for thiol compounds below μmol level with high sensitivity and selectivity and short response time. In the case of aminoethanethiol, the sensor showed a wide linearity range with RSDs <4% for the whole analyses, which reflected the highly reproducible sensor performance. The optimal conditions were investigated. By using the optimized conditions, the detection limit was found to 0.4 μM for aminoethanethiol (based on S/N = 3).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号