共查询到20条相似文献,搜索用时 114 毫秒
1.
2.
3.
4.
5.
6.
7.
喷动床气固流动特性的三维CFD-DEM数值模拟 总被引:1,自引:0,他引:1
开展了柱锥形气固流动特性的CFD-DEM耦合三维数值模拟研究。气相场采用基于欧拉坐标体系的k-ε双方程湍流模型,固相场采用基于拉格朗日坐标体系的DEM直接数值模拟方法,跟踪离散颗粒场的每一个颗粒,考虑颗粒与颗粒(壁面)之间的碰撞力、曳力、重力、Magnus升力、saffman升力。颗粒之间的碰撞采用Hertz-Mindlin无滑移模型计算。模拟对象为柱锥形喷动床,其直径为0.152 m,喷口直径为0.019 m,模拟颗粒数22万,探讨了喷动床中射流随时间的发展,不同气速下床内气固流动结构,以及颗粒速度与颗粒浓度的分布,并与实验数据进行了对比。 相似文献
8.
《工程热物理学报》2015,(7)
本文介绍一种采用光纤式高速摄影测量装置获取三维柱锥形冷态喷动床试验台内部气固两相流颗粒瞬时速度的测量方法、及其测量不确度的分析。基于获取的颗粒相运动视频,计算出颗粒瞬时速度、颗粒相速度和颗粒温度,它们分别用于表征测量区域中颗粒群流动的快慢和脉动的强弱。测量结果表明:镜头畸变校正环节是影响颗粒瞬时速度测量的主要因素,本测量装置的颗粒瞬时速度的测量不确定度为士2.383%;颗粒相速度在喷泉核心区(r/R≤0.2)为正,绝对值较大,沿半径方向减小到零,然后在r/R=0.45处转变方向并逐渐增大;颗粒温度在区域r/R≤0.2和r/R≥0.65变化显著,对应着喷动床内颗粒喷射上行和下落的主要区域,这证实了公开文献中喷动床内颗粒脉动动能分布的数值模拟结果。 相似文献
9.
10.
11.
A review of schemes for multiple access in fiber optic networks shows that a hybrid of wavelength and code division multiple access (WCDMA) combines the best features of both. In particular, the hybrid scheme retains the large information carrying capacity of wavelength division multiple access (WDMA) and flexibility of code division multiple access (CDMA). In this paper WDMA, optical CDMA (OCDMA), and WCDMA networks are discussed. In OCDMA networks, concept of incoherent and coherent coding including inverse decoding and matched filter is introduced. The delay performance of both WDMA and WCDMA networks, under the simple suboptimum access protocols based on cyclic search, is computed. It has been shown quantitatively that tuning delay significantly affects the delay performance of both WDMA and WCDMA networks. Futhermore, delay performance of WCDMA networks is always better than the WDMA networks for the same tuning delay, load, and number of users. 相似文献
12.
Guided-Wave Two-Dimensional Acousto-Optic Scanner Using Proton-Exchanged Lithium Niobate Waveguide 总被引:1,自引:0,他引:1
Two-dimensional scanning of a 0.6328 mum guided-light beam has been realized using noncolinear acousto-optic (AO) coplanar Bragg diffraction together with colinear AO guided-mode to substrate radiation-mode conversion in a Z-cut Xpropagation LiNbO3 proton-exchanged (PE) waveguide. The two surface acoustic (SAW) waves utilized are at the center frequencies of 500 and 200 MHz, propagating in the Y and X axes, respectively. Two-dimensional scanning of approximately 720 resolvable light beam spots, namely, 18 40 (horizontal vertical) scanning, has been demonstrated using a light beam of 1.0 mm aperture. The total number of resolvable beam spots can be greatly increased from 720 by simply utilizing SAW transducers of larger bandwidth and a light beam of greater aperture. It should also be possible to significantly increase the diffraction efficiency from 3 % by optimizing the parameters of the PE waveguide and the SAWs. 相似文献
13.
A simple technique of pulse compression, based on the linear chirp compensation of self-phase modulation (SPM) spectra in dispersion shifted fibers, is demonstrated. The optimization procedure is carried out, for a short span of a single-mode fiber, using a parabolic law, which describes the behavior of the squared output pulse width versus the pump peak power in the case of Gaussian pulses. The experimental results give a minimum pulse duration of 233 fs, which is in good agreement with the model. Shorter and coherent pulses, down to 90 fs, have been obtained by inserting an interference filter at the optical output. 相似文献
14.
S. G. Nedel’ko M. A. Krysyuk A. L. Apanasenko L. N. Lymarenko Z. T. Moroz 《Journal of Applied Spectroscopy》1997,64(1):55-61
Results of a study of the effect of γ-radiation on the spectral luminescence properties of cadmium tungstate crystals doped
with silver, bismuth, and molybdenum cations are presented. Spectral characteristics of the nondnnnoped crystals are briefly
described. Absorption and photo and X-ray luminescence spectra of the crystals taken before and after exposure to γ-radiation
(5.5·104 Gy) are compared. It is found that the spectral characteristics of the crystals doped with silver, bismuth, and molybdenum
cations do not change markedly after the exposure. The relation between the type of impurity-induced defects, individual characteristics
of the impurity cations, and the character of the effect of γ-radiation on the spectral luminescence properties of impure
crystals is analyzed (preliminarily).
Translated from Zhurnal Prikladnoi Spektroskopii, Vol. 64, No. 1, pp. 55–60, January–February, 1997. 相似文献
15.
A multi-conjugate adaptive optics (MCAO) can offer a possibility of widening field of view (FOV) characterized by the isoplanatic angle, and the choose of conjugate height becomes a basic problem for MCAO, which influences the size of iosplanatic angle. Considering the application of lidar, the isoplanatic angle's expressions of two deformable mirrors (DMs) MCAO for uplink and downlink are deduced. The effects of conjugate heights for dual-conjugate AO are thoughtfully discussed, and the isoplanatic angles are further analyzed. The results show that the isopanatic angle varies with the conjugate height and reaches the maximum as the conjugate height is at the optimal altitude. Moreover, the optimal conjugate height changes with the propagation distance. 相似文献
16.
Due to the limit of response speed of the present single-photon detector, the code rate is still too low to come into practical use for the present quantum key distribution (QKD) system.A new idea is put up to design a quick single-photon detector.This quick single-photon detector is composed of a multi-port optic-fiber splitter and many avalanche photo diodes (APDs).Au of the ports with APDs work on the time division and cooperate with a logic discriminating and deciding unit driven by the clock signal.The operation frequency lies on the number N of ports, and can reach N times of the conventional single-photon detector.The single-photon prompt detection can come true for high repetition-rate pulses.The applying of this detector will largely raise the code rate of the QKD, and boost the commercial use. 相似文献
17.
18.
References: 《声学学报:英文版》2008,27(1):23-33
The performance of port/starboard discrimination of dual-line array will be seriously degraded when the space between the two line arrays of the dual-line array is mismatched. The directivity function of the delay-sum and delay-subtract beamforming is deduced and the port/starboard discrimination of the delay-sum and delay-subtract beamforming is also studied both under the ideal status and the status under which the space between the two line arrays of the dual-line array is mismatched. Analysis results show the delay-subtract beamforming has better performance of port/starboard discrimination. At last, the sea trial results demonstrate the theoretical results. 相似文献
19.
The Shanghai Synchrotron Radiation Facility(SSRF)booster ring,a full energy injector for the storage ring,is deigned to accelerate the electron beam energy from 150MeV to 3.5GeV that demands high extraction efficiency at the extraction energy with low beam loss rate when electrons are ramping.Closed orbit distortion(COD)caused by bending magnet field uniformity errors which affects the machine performance harmfully could be effectively reduced by bending magnet location sorting.Considering the affections of random errors in measurement,both ideal sorting and realistic sorting are studied based on measured bending magnet field uniformity errors and one reasonable combination of bending magnets which can reduce the horizontal COD by a factor of 5is given as the final installation sequence of the booster bending magnets in this paper. 相似文献
20.
With a novel light-weight and absolutely calibrated ultraviolet (UV) spectrometer, UV skylight radiances and O3 slant column densities are measured by balloon-borne limb measurements in Xinjiang area, China. UV skylight radiances measured at the height of 31 km are compared with the results from Modtran in the wavelength range from 290 to 420 nm. O3 slant column densities are derived from radiance spectra in the Huggins bands (320 - 335 nm) using differential optical absorption spectroscopy method. And the parameter exhibits a good correlation with the same value simulated by radiative transfer model (Tracy). The O3 profile simultaneously measured by an O3 sonde is used as input in Tracy calculations. The O3 sonde is launched on the same balloon. 相似文献