首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A novel flow-injection chemiluminescence method for the determination of DNA at ultra-trace level has been established. In 0.8 M sulfuric acid media, the chemiluminescence of the rhodamine B-cerium (IV) or Ce(IV) system is enhanced by DNA, activated previously by imidazole-HCl buffer solution (pH 7.0). The enhanced intensity of chemiluminescence is in proportion to log DNA concentration 1.0×10−8 to 0.1 μg ml−1 for herring sperm DNA and 2.0×10−6 to 0.2 μg ml−1 for calf thymus DNA with 3σ detection limits of 8.3×10−9 μg ml−1 for herring sperm DNA and 3.5×10−7 μg ml−1 for calf thymus DNA, respectively. The relative standard deviation for 1.0×10−4 μg ml−1 herring sperm DNA was 0.99% and 2.0×10−3 μg ml−1 for calf thymus DNA was 1.1% (n=11). Using the optimized system, DNA contents in six synthetic samples has been determined with recoveries of 99.5-109.0%. The possible mechanism has also been studied in this paper.  相似文献   

2.
Yongqiang Cheng  Yuqin Su 《Talanta》2007,71(4):1757-1761
A novel assay of DNA has been proposed by using ferric nanoparticles as probes coupled with resonance light scattering (RLS) detection. At pH 7.40, the RLS intensity of ferric nanoparticles can be greatly enhanced by the aggregation of positively charged ferric nanoparticles through electrostatic interaction with negatively charged DNA. The enhanced intensity of RLS at 452 nm is proportional to the concentration of DNA in the range of 0.01-0.8 μg ml−1 for calf thymus and salmon sperm DNA and in the range of 0.005-0.3 μg ml−1 for E. coli K12 genomic DNA. Detection limits are 3.6 ng ml−1 for calf thymus DNA, 4.4 ng ml−1 for salmon sperm DNA, and 1.9 ng ml−1 for E. coli K12 genomic DNA, respectively. Compared with the chromophores previously used in RLS assay, the ferric nanoparticles have offered several advantages in easy preparation, good photostability and high sensitivity without being modified or functionalized.  相似文献   

3.
Based on the measurements of molecular absorption and resonance light scattering (RLS), the aggregation of Azur B (AB) was in a medium of pH ranging from 1.98 to 2.56 and ionic strength <0.12 M. The presence of double stranded DNA prompts the aggregation, resulting in enhanced RLS signals. Linear relationships were achieved between the enhanced RLS intensity at 359.7 nm and DNA concentration in the range of 0-4.5 μg ml−1 for both calf thymus DNA (ctDNA) and fish sperm DNA (fsDNA) if 3.0×10−5 M AB was employed. The 3σ limits of detection were 9.3 and 8.9 ng ml−1 for ctDNA and fsDNA, respectively. Five synthetic samples were analysed satisfactorily.  相似文献   

4.
Dongmei Cheng 《Talanta》2009,78(3):949-753
A novel fluorometric sensing of malachite green is proposed in this paper. The native double-stranded calf thymus DNA was used as sensing material. In the presence of native double-stranded calf thymus DNA, malachite green could interact with the DNA, which resulted in a strong fluorescence emission. The fluorescent intensity was linear with malachite green concentration in the range of 4.0 × 10−10 − 1.8 × 10−7 g ml−1 and the limit of detection was 2.0 × 10−10 g ml−1. Before fluorescence measurement, the only required operation is the mixing of two solutions. So, this method is rather simple and rapid. The method is very safe for the analyst. Furthermore, the mechanism for fluorescence enhancing of native double-stranded calf thymus DNA on MG was proposed based on a series of experiments. The results suggest that the interaction between MG and calf thymus DNA is intercalation in nature.  相似文献   

5.
A sensitive and selective flow injection chemiluminescence (CL) method combined with controlled potential electrolysis technique was described for the determination of molybdenum. The method is based on the chemiluminescence reaction of luminol with unstable molybdenum(III) in alkaline solution. The molybdenum(III) was on-line reduced from molybdenum(VI) via controlled potential electrolysis technique using a homemade flow-through carbon electrolytic cell at the potential of −0.6 V (versus Ag/AgCl). The method allows the determination of molybdenum in the 5.0×10−10 to 5.0×10−7 g ml−1 range with a limit of detection (3σ) of 5×10−11 g ml−1 molybdenum. The relative standard deviation is 2.6% for the 1.0×10−9 g ml−1 molybdenum solution in 11 repeated measurements. This method was successfully applied to the determination of molybdenum in water samples.  相似文献   

6.
A novel integrated chemiluminescence (CL) flow sensor for the determination of adrenaline and isoprenaline is developed based on the enhancing effect of analytes on CL emission of luminol oxidized by periodate in alkaline solution. The analytical reagents luminol and periodate are immobilized on anion exchange resins, respectively, and packed in a glass tube to construct a reagentless sensor. The proposed sensor allows the determination of adrenaline and isoprenaline over the range from 2.0×10−8 to 1.0×10−5 g ml−1 and 2.0×10−7 to 5.0×10−5 g ml−1, respectively. The detection limits are 7.0×10−9 g ml−1 for adrenaline and 5.0×10−8 g ml−1 for isoprenaline with a relative standard deviation of 1.7% for the 1.0×10−7 g ml−1 adrenaline (n=11) and 2.1% for 1.0×10−6 g ml−1 isoprenaline (n=11). The sample throughput was 60 samples h−1. The sensor has been successfully applied to the determination of adrenaline and isoprenaline in pharmaceutical preparations.  相似文献   

7.
Long X  Miao Q  Bi S  Li D  Zhang C  Zhao H 《Talanta》2004,64(2):366-372
In weakly acidic buffer medium, the interaction of amikacin with calf thymus DNA, yeast RNA and denatured DNA has been investigated by using resonance Rayleigh scattering (RRS) technique. The result shows that calf thymus DNA is capable of enhancing the RRS intensity of the amikacin, while yeast RNA and denatured DNA have very little enhancement effect. Based on the characteristics, a sensitive assay for detecting double-stranded DNA in the presence of denatured DNA and yeast RNA has been developed. The enhancement of the RRS signal is directly proportional to the concentration of double-stranded DNA in the range 0.02-12.0 μg ml−1 for calf thymus DNA and its detection limit (3σ) is 2.5 ng ml−1. The method shows a wide linear range and high sensitivity, and almost no interference can be observed from RNA, denatured DNA, amino acid and most of the metal ions. The trace amounts of nucleic acid in synthetic samples and practical samples are determined with satisfactory results. Therefore, the proposed method is promising for as an effect means for recognition in vivo and determination in situ of double-stranded DNA.  相似文献   

8.
Song ZH  Zhang N 《Talanta》2003,60(1):161-170
A sensitive chemilumimetric method for the determination of novalgin at the sub-nanogram level is presented. The method is based on immobilized luminol and dichromate chemiluminescence detection coupled with a flow injection system. The intensity of the chemiluminescence can be strongly inhibited by novalgin and the decrement of CL intensity was linear with the logarithm of novalgin concentration in the range of 5.0×10−11 to 5.0×10−8 g ml−1. The detection limit is 2.0×10−11 g ml−1 (3σ) and the relative standard deviation is 2.57% (n=5) for a 1.0×10−10 g ml−1 novalgin sample. A typical analytical procedure, including sampling and washing, could be performed in 1 min at a flow rate of 2.0 ml min−1, giving a throughput of 60 h−1. The proposed procedure was applied successfully in pharmaceutical preparations and furthermore the monitoring of novalgin in human urine without any pre-treatment process during 10 h. It was found that the novalgin concentration reached its maximum after orally administrated for about 4 h, and the novalgin metabolism ratio in 10 h was 10.83% in the body of volunteers. The flow system offered reagentless procedures and remarkable stability in determination of novalgin, and could be easily reused over 600 times.  相似文献   

9.
A chemiluminescence (CL) flow system for determination of thyroxine (Thy) is presented. It is based on the catalytic effect of cobalt(II) on the CL reaction between luminol and hydrogen peroxide. The iodinated chemical structure of Thy causes a heavy atom effect. The luminol CL signals show significant quenching by Thy. The calibration graph for Thy is linear for 15-70 μg ml−1 and the 3σ detection limits are 27 μg ml−1 for d-Thy and 23 μg ml−1 for l-Thy.  相似文献   

10.
Wang Z  Zhang Z  Fu Z  Luo W  Zhang X 《Talanta》2004,62(3):611-617
A novel and sensitive chemiluminescence (CL) method for the determination of aminomethylbenzoic acid and aminophylline coupled with flow-injection analysis (FIA) technique is developed in this paper. It is based on the inhibition effect of the studied drugs on the chemiluminescence emission of N-bromosuccinimide-luminol (NBS-luminol) system. Under the optimum conditions, the decreased CL intensity is linear with the concentration of aminomethylbenzoic acid in the range of 2×10−8 to 1.0×10−6 g ml−1 and with the concentration of aminophylline in the range of 1×10−7 to 7.0×10−6 g ml−1, respectively. The detection limit is 7.0×10−9 g ml−1 for aminomethylbenzoic acid (3σ) and 3.4×10−8 g ml−1 for aminophylline (3σ). The relative standard deviations (R.S.D.) for 11 parallel measurements of 2.0×10−7 g ml−1 aminomethylbenzoic acid and 1.0×10−6 g ml−1 aminophylline are 2.6 and 3.0%, respectively. The proposed methods have been applied for the determination of the studied drugs in their pharmaceutical formulations with satisfactory results. The possible use of the proposed system for the determination of aminomethylbenzoic acid in plasma sample was also tested. The possible inhibition mechanism of aminomethylbenzoic acid and aminophylline on luminol-NBS system was discussed briefly.  相似文献   

11.
A simple chemiluminometric method using flow injection has been developed for the determination of paracetamol (acetaminophen), based on the chemiluminescence produced by the reduction of tris(2,2′-bipyridyl)ruthenium(III). The latter is obtained by oxidation of tris(2,2′-bipyridyl)ruthenium(II) by potassium permanganate in dilute sulphuric acid in the presence of paracetamol. A standard or sample solution was injected into the ruthenium(II) stream (flow rate 1.5 ml min−1) which was then merged with potassium permanganate in dilute sulphuric acid stream (flow rate 0.5 ml min−1). The chemiluminescence intensity is enhanced by the presence of manganese(II) ions. Under the optimum conditions, a linear calibration graph was obtained over the range of 0.3-50.0 μg ml−1 and the detection limit was 0.2 μg ml−1 (s/n = 3). The relative standard deviation of the proposed method calculated from 20 replicate injections of 5.0 μg ml−1 paracetamol was 1.1%. The sample throughput was 90 h−1. The method was successfully applied to the determination of paracetamol in commercial pharmaceutical formulations.  相似文献   

12.
Nanometer-sized fluorescent particles have been successfully synthesized. A synchronous fluorescence method, with high sensitivity and selectivity, has been developed for rapid determination of protein with functionalized CdS as a fluorescence probe. When Δλ=260 nm, maximum synchronous fluorescence is produced at 274 nm at pH 7.0. Under optimal conditions, the calibration graphs are linear over the range 0.1-3.0 μg ml−1 for bovine serum albumin (BSA), 0.1-11.0 μg ml−1 for γ-globulin (γ-G) and 0.1-1.4 μg ml−1 for human serum albumin (HSA), respectively. Limits of determination were 0.01 μg ml−1 for BSA, 0.019 μg ml−1 for γ-G and 0.021 μg ml−1 for HSA, respectively. The relative standard deviations of seven replicate measurements were 1.8% for 1.0 μg ml−1 BSA, 2.2% for 1.0 μg ml−1 γ-G and 2.3% for 1.0 μg ml−1 HSA.  相似文献   

13.
A simpler UV-vis spectrophotometric method was investigated for hydroquinone (HQ) determination using KMnO4 as oxidizing agent for conversion of HQ to p-benzoquinone (BQ) as well as signal enhancer. Various parameters such as analytical wavelength, stability time, temperature, pH, solvent effect and interference of chemicals were checked and parameters optimized by using 1 μg ml−1 standard solution of HQ. Beer's Law was applicable in the range of 0.07-2 μg ml−1 and 0.005-0.05 μg ml−1 at 245.5 nm and at 262 nm for aqueous standard solutions of HQ with linear regression coefficient value of 0.9978 and 0.9843 and detection limit of 0.021 μg ml−1 and 0.0016 μg ml−1 HQ, respectively. Standard deviation of 1.7% and 2.4% was true for 1 μg ml−1 and 0.03 μg ml−1 HQ solution (n = 11) run at respective wavelengths. The method was successfully applied to dilute waste photographic developer samples for free HQ determination.  相似文献   

14.
Chen X  Wang J  Fang Z 《Talanta》2005,67(1):227-232
A micro-sequential injection spectrophotometric procedure for DNA assay was developed based on the employment of a lab-on-valve (LOV) meso-fluidic analytical system. A small amount of crystal violet solution (10 μl) was de-colored inside the flow cell of the LOV at the presence of 5 μl λ-DNA/HindIII within a certain pH range, and the absorbance decrease of crystal violet solution at 591 nm was measured via optical fibers and was employed as the basis of quantification. A uni-variant approach was adopted for the optimization of experimental parameters, including buffer pH, concentration and volume of crystal violet solution, reaction time and sample/reagent loading flow rates. A linear calibration graph was obtained within 0.2-6.0 μg ml−1, along with a detection limit of 0.07 μg ml−1. The procedure was applied for the determination of λ-DNA/HindIII in synthetic samples in comparison with a documented procedure.  相似文献   

15.
A new, accurate, sensitive and fast reversed-phase high-performance liquid chromatography (RP-HPLC) as an analytical method for the quantitative determination of 11 drugs in human urine was worked out, optimized and validated. The objects of analysis were imipenem (IMP), paracetamol (PAR), dipyrone (DPR), vancomycin (VCM), amikacin (AMK), fluconazole (FZ), cefazolin (CFZ), prednisolone (PRE), dexamethasone (DEX), furosemide (FUR) and ketoprofen (KET) belonging to four different groups (antibiotics, analgesic, demulcent and diuretic). For HPLC analysis, diode array (DAD) and fluorescence (FL) detectors were used. The separation of analyzed compounds was conducted by means of a LiChroCART® Purospher® C18e (125 mm × 3 mm, particle size 5 μm) analytical column with LiChroCART® LiChrospher® C18 (4 mm × 4 mm, particle size 5 μm) pre-column with gradient elution. Analyzed drugs were determined within 20 min. The mobile phase was comprised of various proportions of methanol, acetonitrile and 0.05% trifluoroacetic acid in water. AMK was separated and determined from human urine using ortho-phthaldialdehyde-3-mercaptopropionic acid (OPA-3-MPA) as a fluorescent reagent by RP-HPLC-FL. The following retention times for drugs IMP, PAR, DPR, VCM, AMK, FZ, CFZ, PRE, DEX, FUR and KET in human urine were found: 4.01 min, 4.86 min, 6.71 min, 8.14 min, 9.46 min, 10.01 min, 10.90 min, 13.34 min, 14.06 min, 16.03 min and 18.98 min, respectively. Excellent linearity was obtained for compounds in the range of concentration: 0.35-42 μg ml−1, 0.5-45 μg ml−1, 4.5-38 μg ml−1, 0.25-25 μg ml−1, 0.5-35 μg ml−1, 0.25-22 μg ml−1, 0.03-52 μg ml−1, 0.15-25 μg ml−1, 0.25-28 μg ml−1, 0.05-18 μg ml−1 and 0.15-35 μg ml−1 for IMP, PAR, DPR, VCM, AMK, FZ, CFZ, PRE, DEX, FUR and KET, respectively. The limits of detection (LOD) and limits of quantification (LOQ) for analyzed drugs were calculated in all cases and recovery studies were also performed. Ten human urine samples obtained from patients treated in hospital have been tested. In analyzed samples, one or more drugs from the 11 examined drugs were detected. The concentrations of examined drugs in urine samples ranged between: 1.5-12 μg ml−1 of PAR, 5.2-11.5 μg ml−1 of DPR, 0.13-9.5 μg ml−1 of CFZ and 0.1-8 μg ml−1 of FUR. This method can be successfully applied to routine determination of all these drugs in human urine samples.  相似文献   

16.
Chen X  Wang J 《Talanta》2006,69(3):681-685
A sensitive procedure for the quantification of total protein bovine serum albumen (BSA) in human serum was presented with sequential injection sampling and fluorometric detection. A few microliters of sample and fluorescamine solutions were aspirated into the holding coil to facilitate the reaction of protein with fluorescamine by giving rise to a blue-green-fluorescent derivative. The derivative was afterwards excited by a 400 nm radiation from a UV radiator, and the emitted fluorescence was monitored at the wavelength of 470 nm. By loading 5.0 μl of sample and 4.0 μl of fluorescamine solution 0.075% (m/v), a linear calibration graph was obtained within 0.3-12.5 μg ml−1, and a detection limit (3σ) of 0.1 μg ml−1 was achieved, along with a sampling frequency of 40 h−1 and a R.S.D. value of 2.1% at the 5.0 μg ml−1 levels. Protein contents in human serums were analyzed by using the present procedure, and reasonable agreements were obtained with those obtained by a documented spectrophotometric (Biuret) method.  相似文献   

17.
A simple and reliable method based on adsorptive stripping at an electrochemically pretreated glassy carbon electrode (GCE) was proposed for simultaneous or individual determination of guanine and adenine in DNA. The detection sensitivity of guanine and adenine was improved greatly by activating the GCE electrochemically. After accumulation on pretreated GCE at open circuit for 5 min or at the potential of +0.3 V for 120 s, guanine and adenine produced well-defined oxidation peaks at about +0.8 and +1.1 V, respectively in pH 5 phosphate buffer. The detection limit for individual measurement of guanine and adenine was 4.5 ng ml−1 (3×10−8 mol l−1) and 4 ng ml−1 (3×10−8 mol l−1), respectively. Acid-denatured DNA showed two oxidation peaks corresponding to guanine and adenine residues in the same buffer. The proposed method can be used to estimate the guanine and adenine contents in DNA with good selectivity in a linear range of 0.25-5 μg ml−1.  相似文献   

18.
A simple flow injection colourimetric procedure for determining andrographolide was proposed. It is based on the reaction between andrographolide with 3,5-dinitrobenzoic acid, resulting in an intense purplish red complex with a suitable absorption at 536 nm. A standard or sample solution was injected into the 3,5-dinitrobenzoic acid stream (flow rate of 1.0 ml min−1) which was then merged with potassium hydroxide stream with the same flow rate. Optimum conditions for determining andrographolide were investigated by univariate method. Under the optimum conditions, a linear calibration graph was obtained over the range 5.0-150.0 μg ml−1 and the detection limit was 1.50 μg ml−1 (3σ). The relatives standard deviation of the proposed method calculated from 10 replicate injections of 10.0 and 80.0 μg ml−1 andrographolide were 0.66% and 1.64%, respectively. The sample throughput was 50 h−1. The proposed method has been satisfactorily applied to the determination of andrographolide in herb plant samples.  相似文献   

19.
A simple and rapid spectrophotometric method is proposed for the determination of transparent exopolymer particles (TEP) in freshwater samples. In this method, TEP reacts with excess of alcian blue solution yielding a low solubility dye-TEP complex. After centrifugation, the concentration of the remaining dye in the supernatant was determined at 602 nm and its concentration was related to the concentration of TEP in freshwater. The effect of alcian blue concentration from 1.5×10−3 to 9.0×10−3% (m/v), solution pH from 2.5 to 6.9 and stirring time from 20 to 120 s on the analytical curve was investigated. Under the optimum conditions established, such as alcian blue concentration of 3.0×10−3% (m/v); pH of 4.0 (0.2 mol l−1 acetate buffer solution) and stirring time of 1 min, the analytical curve was linear from 0.50 to 10 μg ml−1 (A=0.34−0.037[GX]; r2=0.9999; where A is the absorbance and [GX] the gum xanthan concentration in μg ml−1) with a detection limit of 0.10 μg ml−1. The recovery of TEP (as gum xanthan) for two samples ranged from 95.3 to 108 and the relative standard deviations (R.S.D.s) were lower than 0.8% for gum xanthan solutions at concentrations of 1.0 and 1.5 μg ml−1 (n=8). The results obtained for TEP in freshwater samples using the proposed spectrophotometric method and those obtained using a literature method are in agreement at the 95% confidence level and within an acceptable range of error.  相似文献   

20.
Haiping Zhou  Jinghe Yang 《Talanta》2009,78(3):809-813
It is found that Al(III) can further enhance the intensity of resonance light scattering (RLS) of the silver nanoparticles (AgNPs) and nucleic acids system. Based on this, a novel method of determination of nucleic acids is proposed in this paper. Under optimum conditions, there are linear relationships between the enhancing extent of RLS and the concentration of nucleic acids in the range of 1.0 × 10−9-1.0 × 10−7 g mL−1, 1.0 × 10−7-2.0 × 10−6 g mL−1 for fish sperm DNA (fsDNA), 1.0 × 10−9-7.0 × 10−8 g mL−1 for calf thymus DNA (ctDNA) and 1.0 × 10−9-1.0 × 10−7 g mL−1 for yeast RNA (yRNA). The detection limits (S/N = 3) of fsDNA, ctDNA and yRNA are 4.1 × 10−10 g mL−1, 4.0 × 10−10 g mL−1 and 4.5 × 10−10 g mL−1, respectively. The studies indicate that the RLS enhancement effect should be ascribed to the formation of AgNPs-Al(III)-DNA aggregations through electrostatic attraction and adsorption bridging action of Al(III). And the sensitivity and stability of the AgNPs-fsDNA system could be enhanced by Al(III).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号