首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
A novel and sensitive method was developed for the determination of tebuconazole enantioselectively using reversed‐phase LC‐MS/MS. The separation and determination were performed using on an amylose‐based chiral stationary phase, a Lux 3u Amylose‐2 column (150 mm×2.0 mm), under isocratic conditions at 0.3 mL/min flow rate. A series of chiral stationary phases were investigated and the effect of mobile phase composition on the enantioseparation was discussed. Parameters including the matrix effect, linearity, precision, accuracy and stability were evaluated. Under optimal conditions, the overall mean recoveries for two enantiomers from the soil, tomato, cucumber, pear and apple samples were 79.3–101.1% with 2.8–11.5% intra‐day relative standard deviations (RSDs) and 4.1–8.6% inter‐day RSDs at 5, 25 and 50 μg/kg levels; the mean enantiomer recoveries from the water samples were 89.6–101.9% with 3.3–10.2% intra‐day RSDs and 5.1–7.7% inter‐day RSDs at 0.25, 0.5 and 2.5 μg/kg levels. The limits of detection (LODs) for all enantiomers in tomato, cucumber, pear, apple, soil and water were less than 0.6 μg/kg, whereas the limit of quantification (LOQ) did not exceed 2.0 μg/kg. The results indicate that this proposed method is convenient and reliable for the enantioselective determination of tebuconazole enantiomers in foods and environment samples.  相似文献   

2.
A simple and rapid method for determining six ergot alkaloids and four of their respective epimers was developed for rye and wheat. The analytes were extracted from the sample matrix with ACN/ammonium carbonate solution. The extract was purified with a commercial push‐through SPE column (Mycosep® 150 Ergot). After concentration and filtration steps, the final separation of the analytes was achieved with ultra‐performance LC‐MS/MS. The chromatographic separation of the ergot alkaloids was achieved in 4.5 min. The method performance proved satisfactory in the preliminary validation. The calculated LOQs were low ranging from 0.01 to 1.0 μg/kg for wheat and from 0.01 to 10.0 μg/kg for rye. At the concentration levels of 10, 50 and 200 μg/kg, the recoveries were between 80 and 120% in most cases and the within‐day repeatability (expressed as RSD) ranged between 1.3 and 13.9%. Despite the cleanup of the samples, some matrix effect was observed in the MS, highlighting the necessity of using matrix‐assisted standards. This is the first article to describe the application of the push‐through columns and ultra‐performance LC in the analysis of ergot alkaloids.  相似文献   

3.
A simple, fast and low‐cost extraction method with high‐performance liquid chromatography–tandem mass spectrometry (HPLC‐MS/MS) determination was developed on sulfonamide antibiotics (SAs) in fish tissue. Magnetic separation was first introduced into the rapid sample preparation procedure combined with acetonitrile extraction for the analysis of SAs. Partitioning was rapidly achieved between acetonitrile solution and solid matrix by applying an external magnetic field. Acetonitrile solution was collected and concentrated under a nitrogen stream. The residue was redissolved with 1‰ formic acid aqueous solution and defatted with n‐hexane before analysis. The recoveries of SAs were in the range of 74.87–104.74%, with relative standard deviations <13%. The limits of quantification and the limits of detection for SAs ranged from 5.0 to 25.0 μg kg?1 and from 2.5 to 10.0 μg kg?1, respectively. The presented extraction method proved to be a rapid method which only took 20 min for one sample preparation procedure. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

4.
建立了多类粮食作物中15种磺酰脲类除草剂的超高效液相色谱-串联质谱联用仪(UPLC/MS/MS)多离子监测(MRM)的多残留检测方法。样品经乙腈提取,乙腈饱和的正己烷液-液分配,石墨化碳氨基小柱净化,采用UPLC-MS/MS(ESI+)测定。方法中各种磺酰脲类除草剂在5~200μg/L浓度范围内线性良好,相关系数在0.9995~0.9999。在5~100μg/kg范围内,平均加标回收率在71.6%~115.3%之间,相对标准偏差不大于15%。各种药物的定量限(S/N≥10)均可达到5μg/kg。该方法可同时满足大豆、大米、玉米等多种粮食中磺酰脲类除草剂的检测需求。  相似文献   

5.
This study describes a comparison between LC‐UV and LC–MS method for the simultaneous analyses of a few disease‐modifying agents of multiple sclerosis. Quantitative determination of fampridine (FAM), teriflunomide (TFM) and dimethyl fumarate (DMF) was performed in human plasma with the recovery values in the range of 85–115%. A reversed‐phase high‐performance liquid chromatography (HPLC) with UV as well as MS detection is used. The method utilizes an XBridge C18 silica column and a gradient elution with mobile phase consisting of ammonium formate and acetonitrile at a flow rate of 0.5 mL min?1. The method adequately resolves FAM, TFM and DMF within a run time of 15 min. Owing to low molecular weights, the estimation of DMF and FAM is more versatile in UV than MS detection. With LC‐UV, the detection limits of FAM, TFM and DMF were 0.1, 0.05, 0.05 μg and the quantification limit for all the analytes was 1 μg. With LC–MS, the detection and quantification limits for all of the analytes were 1 and 5 ng, respectively. The two techniques were completely validated and shown to be reproducible and sensitive. They were applied to a pharmacokinetic study in rats by a single oral dose. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

6.
We developed an analytical method using liquid–liquid extraction (LLE) and liquid chromatography–tandem mass spectrometry (LC‐MS/MS) to detect and quantify tebufenozide (TEB) and indoxacarb (IND) residues in animal and aquatic products (chicken muscle, milk, egg, eel, flatfish, and shrimp). The target compounds were extracted using 1% acetic acid (0.1% acetic acid for egg only) in acetonitrile and purified using n‐hexane. The analytes were separated on a Gemini‐NX C18 column using (a) distilled water with 0.1% formic acid and 5 mm ammonium acetate and (b) methanol with 0.1% formic acid as the mobile phase. All six‐point matrix‐matched calibration curves showed good linearity with coefficients of determination (R2) ≥0.9864 over a concentration range of 5–50 μg/kg. Intra‐ and inter‐day accuracy was expressed as the recovery rate at three spiking levels and ranged between 73.22 and 114.93% in all matrices, with a relative standard deviation (RSD, corresponding to precision) ≤13.87%. The limits of quantification (LOQ) of all target analytes ranged from 2 to 20 μg/kg, which were substantially lower than the maximum residue limits (MRLs) specified by the regulatory agencies of different countries. All samples were collected from different markets in Seoul, Republic of Korea, and tested negative for tebufenozide and indoxacarb residues. These results show that the method developed is robust and may be a promising tool to detect trace levels of the target analytes in animal products.  相似文献   

7.
A rapid, simple and sensitive ultra high‐performance liquid chromatography (UHPLC‐MS/MS) method was established for determining the absorption amount of emodin in the five digestive segments of rat. Plasma samples were pre‐purified by solid‐phase extraction (SPE) with Oasis MAX cartridge. Separation of emodin and 1,8‐dihydroxyanthraquinone (internal standard) was performed on an Acquity BEH UHPLC C18 column (100 mm×2.1 mm, 1.7 μm) with gradient elution of methanol and 0.1% formic acid aqueous solution. The LC/MS system was operated under multiple reaction monitoring mode using electrospray ionization (ESI) in negative ion mode. The results showed that this established method was valid and sensitive for emodin within 0.04–16.4 μg/mL, with low limits of detection and quantification of 0.6 ng/mL and 2.4 ng/mL, respectively and upper limit of quantification of 220.0 ng/mL. The intra‐ and interday variations were below 4.9% of RSD. The extraction recoveries were 98.9–106.1% with RSD of 1.9–3.2%. The plasma concentration‐time relationship showed that the absorption of emodin in stomach was faster than in intestine segments. The sequence of absorption amount was: ileum>jejunum>colon≈duodenum>stomach. Most of emodin was absorbed in ileum, and the absorption amount was increased with prolonged retention of drug form in intestine, especially in ileum and jejunum. The developed UHPLC‐ESI‐MS/MS method was appropriate for determining the in vivo absorption of emodin in other herbal medicines or preparations containing this compound.  相似文献   

8.
Cefuroxime lysine is a new second‐generation cephalosporins, which can penetrate the blood–brain barrier to cure the meningitis. In order to investigate its acute toxicokinetic study after intraperitoneal injection of 675 mg/kg cefuroxime lysine, a sensitive and clean ultra‐fast liquid chromatography–tandem mass spectrometry (UFLC‐MS/MS) method for the determination of cefuroxime lysine in microdialysate samples was developed and validated, which was compared with UFLC‐UV as a reference method. Chromatographic separation was performed on a Shim‐pack XR‐ODS C18 column (75 × 3.0 mm, 2.2 µm), with an isocratic elution of 0.1% formic acid in acetonitrile–0.1% formic acid in water (45:55, v/v) for LC‐MS and acetonitrile–20 mm potassium dihydrogen phosphate (pH 3.0,20:80, v/v) for LC‐UV. The lower limit of detection was 0.01 µg/mL for LC‐MS and 0.1 µg/mL for LC‐UV method, with the same corresponding linearity range of 0.1–50 µg/mL. The intra‐ and inter‐day precisions (relative standard deviation) for both methods were from 1.1 to 8.9%, while the accuracy was all within ±10.9%. The results of both methods were finally compared using paired t‐test; the results indicated that the concentrations measured by the two methods correlated significantly (p < 0.05), which suggested that the two methods based on LC‐MS and LC‐UV were suitable for the acute toxicokinetic study. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
A new solid‐phase extraction (SPE) pretreatment method using a home‐made polyvinylpolypyrrolidone‐florisil (PVPP‐F) column was developed for the analysis of patulin in apple and hawthorn products in China. Fifty samples (25 apple juices, 12 apple jams, and 13 hawthorn juices) were prepared using the new method and then analyzed by high performance liquid chromatography with diode array detection (HPLC‐DAD) on an Agela Venusil MP C18 reversed‐phase column (4.6 mm × 250 mm, 5 μm). The cleanup results for all samples using home‐made PVPP‐F column were compared with those obtained using a MycoSep®228 AflaPat column. The correlation coefficient R (0.9998) fulfilled the requirement of linearity for patulin in the concentration range of 2.5–250 μg/kg. The limits of detection (LODs) and quantification (LOQs) of patulin were 3.99 and 9.64 μg/kg for PVPP‐F column, and 3.56 and 8.07 μg/kg for MycoSep®228 AflaPat column, respectively. Samples were spiked with patulin at levels ranging from 25 to 250 μg/kg, and recoveries using PVPP‐F and MycoSep®228 AflaPat columns were in the range of 81.9–100.9% and 86.4–103.9%, respectively. Naturally occurring patulin was found in 2 of 25 apple juice samples (8.0%) and 1 of 13 hawthorn juice samples (7.7%) at concentrations ranging from 12.26 to 36.81 μg/kg. The positive results were further confirmed by liquid chromatography electrospray ionization mass spectrometry (LC‐ESI‐MS).  相似文献   

10.
建立了一种基于QuEChERS前处理技术和超高效液相色谱-串联质谱(UHPLC-MS/MS)同时测定土壤中31种磺酰脲类除草剂残留的方法。通过对色谱条件、提取溶剂、净化剂等进行优化,确定以甲醇和0.1%甲酸+5 mmol/L乙酸铵为流动相,1%(体积分数)乙酸-乙腈为提取溶剂,C18(25.00 mg/mL)为净化剂。31种磺酰脲类除草剂的线性关系良好,相关系数(r2)均不小于0.998 0,定量下限(S/N=10)为0.012~2.321μg/kg。3个加标水平(10、100、400μg/kg)下的平均回收率为71.8%~119%,相对标准偏差(RSD)为0.62%~13%。除烟嘧磺隆、三氟啶磺隆钠、玉嘧磺隆、啶嘧磺隆、氯吡嘧磺隆为中等强度基质效应外,其余待测物均表现为弱基质效应。该方法简便易操作,具有较好的灵敏度和准确度,适用于土壤中31种磺酰脲类除草剂残留的同时检测。  相似文献   

11.
An ultra‐performance LC in combination with MS/MS method was established to evaluate the quality of Wu‐yao (the dried root of Lindera aggregata (Sims) Kosterm. (Lauraceae)) through simultaneous quantitation of five sesquiterpene lactones, linderagalactone D ( 1 ), linderagalactone C ( 2 ), hydroylindestenolide ( 3 ), neolinderalactone ( 4 ) and linderane ( 5 ). All compounds were separated on a Waters Acquity ultra‐performance LC HSS T3 column (2.1 mm×100 mm, 1.8 μm particle size) with linear gradient elution of acetonitrile and 0.1% formic acid. An ESI interface in the positive mode was employed prior to MS detection. All the compounds showed good linearity (R2≥0.9992). The recoveries, measured at three concentration levels, varied from 97.3 to 103.4% with RSDs <4.8%. The simple, rapid and reliable method was successfully applied to quantify the five components in 13 samples of Wu‐yao from different areas.  相似文献   

12.
A solid‐phase extraction (SPE) method was developed to extract 14 pesticides simultaneously from environment samples using cigarette filter as the sorbent before gas chromatography‐mass spectrometry (GC‐MS) analysis. Parameters influencing the extraction efficiency, such as the sample loading flow rate, eluent and elution volume, were optimized. The optimum sample loading rate was 3 mL/min, and the retained compounds were eluted with 6 mL of eluent at 1 mL/min under vacuum. Good linearity was obtained for all the 14 pesticides (r2>0.99) from 0.1 to 20 μg/L for water and from 2 to 400 μg/kg for soil samples. The detection limits (signal‐to‐noise=3) of the proposed method ranged from 0.01 to 0.20 μg/L for water samples and from 0.42 to 6.95 μg/kg for soil samples. The developed method was successfully applied for determination of the analytes in real environmental samples, and the mean recoveries ranged from 76.4 to 103.7% for water samples and from 79.9 to 105.3% for soil samples with the precisions (relative standard deviation) between 2.0 and 13.6%.  相似文献   

13.
A speedy and selective ultra‐HPLC‐MS/MS method for simultaneous determination of deoxynivalenol (DON), 3‐acetyldeoxynivalenol (3‐ADON), 15‐ADON, nivalenol and fusarenon X in traditional Chinese medicines (TCMs) was developed. The method was based on one‐step sample cleanup using reliable homemade cleanup cartridges. A linear gradient mobile‐phase system, consisting of water containing 0.2% aqueous ammonia and acetonitrile/methanol (90:10, v/v) at a flow rate of 0.4 mL/min, and an Acquity UPLC HSS T3 column (100 mm×2.1 mm, 1.8 μm) were employed to obtain the best resolution of the target analytes. [13C15]–DON was used as the internal standard to accomplish as accurate as possible quantitation. The established method was further validated by determining the linearity (R2≥0.9990), sensitivity (LOQ, 0.29–0.99 μg/kg), recovery (88.5–119.5%) and precision (RSD≤15.8%). It was shown to be a suitable method for simultaneous determination of DON, 3‐ADON, 15‐ADON, nivalenol and fusarenon X in various TCM matrices. The utility and practical impact of the method was demonstrated using different TCM samples.  相似文献   

14.
An RP LC‐ESI‐MS/MS method for the determination of the migration of 16 primary phthalic acid esters from plastic samples has been developed using distilled water, 3% acetic acid, 10% alcohol, and olive oil as food simulants. Detection limits were 1.6–18.5 μg/kg in distilled water, 1.4–17.3 μg/kg in 3% acetic acid, 1.4–19.2 μg/kg in 10% alcohol, and 31.9–390.8 μg/kg in olive oil. The RSDs were in the range of 0.07–11.28%. The real plastic products inspection showed that only few analyzed samples were phthalates contaminated. Bis‐2‐ethylhexyl ester and dibutyl phthalate were the common items migrated from the plastic products into food and feeds, but the migration concentrations were far below the limits set by European Union (1.5 mg/kg for bis‐2‐ethylhexyl ester and 0.3 mg/kg for dibutyl phthalate).  相似文献   

15.
A simple confirmatory method for the determination of spiramycin and its metabolite neospiramycin in raw milk using LC ESI MS/MS is presented. Macrolide residues in raw milk were extracted by ACN, and sample extracts were further cleaned up and concentrated using SPE cartridges. Both spiramycin and neospiramycin were protonated in electrospray positive ion mode to form singly and/or doubly charged pseudomolecular ions. Data acquisition was achieved using multiple reaction monitoring, i.e., two transitions, for quantification and confirmation. Matrix‐matched standard calibration curves were utilized to achieve the best accuracy for the method. The method performance was evaluated according to both a conventional validation procedure and a designed experimental result. The measurement uncertainty arising from accuracy and precision was estimated. The method accuracy, expressed as a percentage of an overall recovery, was from 82.1 to 108.8%, and its intermediate precision was less than 20%. LC/ESI‐MS/MS method LODs (S/N ? 3:1) of spiramycin and neospiramycin were less than 1.0 μg/kg.  相似文献   

16.
A rapid and sensitive high‐performance liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated to quantify tilmicosin in pig plasma. Plasma samples were prepared by liquid–liquid extraction. Chromatographic separation was achieved on a C18 column (2.1 × 30 mm, 3.5 μm) using acetonitrile–water (90:10, v /v; water included 0.1% formic acid) as the mobile phase. Mass detection was carried out using positive electrospray ionization in multiple reaction monitoring mode. The calibration curve was linear from 0.5 to 2000 ng/mL (r 2 = 0.9998). The intra‐ and inter‐day accuracy and precision were within the acceptable limits of ±10% for all tilmicosin concentrations. The recoveries ranged from 95 to 99% for the three tested concentrations. The LC–MS/MS method described herein was simple, fast and less laborious than other methods, achieved high sensitivity using a small sample volume, and was successfully applied to pharmacokinetic studies of tilmicosin enteric granules after oral delivery to pigs. In comparison with tilmicosin premix, tilmicosin enteric granules slowed the elimination rate of tilmicosin, prolonged its period of action and significantly improved its bioavailability.  相似文献   

17.
We aimed to investigate the pharmacokinetics, bioavailability and urinary excretion of scopolin and its metabolite scopoletin in rats. An LC–tandem mass spectrometry (MS/MS) method for simultaneous determination of scopolin and scopoletin in rat biomatrices was developed and validated over a plasma and urine concentration range of 5.0–2000 ng/mL. Chromatographic separation was performed on a Hypersil GOLD C18 column with acetonitrile and 0.1% formic acid in water as mobile phase with gradient elution. Detection was performed in the positive ionization and selected reaction monitoring mode. The intra‐ and inter‐batch precision and accuracy, extraction recovery and matrix effect and stability of scopolin and scopoletin were well within the acceptable limits of variation. There was no gender‐related difference in the pharmacokinetic profiles of scopolin. There were significant differences in total area under the concentration–time curve (AUC), time required to achieve a maximal concentration (Tmax) and apparent clearance from plasma (Cl/F) of scopoletin between the male and female rats (p < .05). The bioavailability (F) of scopolin was exceptionally low. The maximal excretion rates were 7.61 μg/h and 7.15 μg/h for scopolin and 31.68 μg/h and 25.58 μg/h for scopoletin in male and female rats, respectively. The LC–MS/MS method was successfully applied to the pharmacokinetic, bioavailability and urinary excretion studies of scopolin and its metabolite scopoletin following a single administration of scopolin to rats.  相似文献   

18.
A simple and reliable method of ultra high performance liquid chromatography coupled with photo‐diode array detection has been proposed for the simultaneous determination of deoxynivalenol and its acetylated derivatives in wheat flour and rice, especially focusing on the optimization of sample extraction, cleanup, and chromatographic separation conditions. Sample pretreatment consisted of a first step using a quick, easy, cheap, effective, rugged, and safe based extraction procedure and a subsequent cleanup step based on solid‐phase extraction. The method was extensively validated in wheat flour and rice, obtaining satisfactory analytical performance with good linearity (R2 ≥ 0.999), acceptable recoveries (80.0–104.4%), and repeatability (RSDs 1.3–10.7%). The limits of detection (21.7–57.4 μg/kg) and quantitation (72.3–191.4 μg/kg) for deoxynivalenols were lower than those usually permitted by various countries’ legislation in these food matrices. The method was applied to 34 wheat and rice samples. The results were further compared with results of ultra high performance liquid chromatography with electrospray ionization tandem mass spectrometry.  相似文献   

19.
A LC‐MS/MS method was developed and validated for the determination of cyclosporine A (CsA) and its three phase 1 metabolites AM1, AM9, and AM4N in whole blood and lymphocytes isolated on the Histopaque gradient. 200 μL of whole blood was precipitated with 10 mol/L zinc sulfate in acetonitrile/methanol (40:60, v/v) and lymphocytes isolated from 1.5 mL blood were extracted with acetonitrile/methanol (40:60, v/v). The analytes and internal standard cyclosporine D were separated on RP column BEH C18, 2.1×50 mm, 1.7 μm using gradient LC‐MS/MS analysis in positive electrospray mode. Time of analysis was 5 min. Linearity in blood was 5–2000 μg/L for CsA, AM1, and AM9; 2–500 μg/L for AM4N; and 2–500 μg/L for all substances in lymphocytes. Coefficient of variations was 1.8–9.8% and recovery was 92.0–110.0%. The method was used in early and chronic renal transplant patients for therapeutic drug monitoring of CsA to compare either its share in lymphocytes as target organ or binding to one lymphocyte. The same parameters were calculated for all metabolites tested.  相似文献   

20.
A sensitive and reliable ultra‐high‐performance liquid chromatography with tandem mass spectrometry (UHPLC–MS/MS) method was developed and validated for simultaneous determination of l ‐tetrahydropalmatine (l ‐THP) and its active metabolites l ‐isocorypalmine (l ‐ICP) and L ‐corydalmine (l ‐CD) in rat plasma. The analytes were extracted by liquid–liquid extraction and separated on a Bonshell ASB C18 column (2.1 × 100 mm; 2.7 μm; Agela) using acetonitrile–formic acid aqueous as mobile phase at a flow rate of 0.2 mL/min in gradient mode. The method was validated over the concentration range of 4.00–2500 ng/mL for l ‐THP, 0.400–250 ng/mL for l ‐ICP and 1.00–625 ng/mL for l ‐CD. Intra‐ and inter‐day accuracy and precision were within the acceptable limits of <15% at all concentrations. Correlation coefficients (r ) for the calibration curves were >0.99 for all analytes. The quantitative method was successfully applied for simultaneous determination of l ‐THP and its active metabolites in a pharmacokinetic study after oral administration with l ‐THP at a dose of 15 mg/kg to rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号