首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 578 毫秒
1.
A method for the simultaneous determination of μg/1 or sub-μg/1 levels of cadmium and lead in sea water by chelation ion chromatography is demonstrated. The method consists in the preconcentration of a sea-water sample containing cadmium and lead on an iminodiacetate chelating resin; alkali and alkaline earth metals are removed from the resin with an ammonium acetate buffer, the metals are eluted and separated by cation-exchange chromatography, followed by postcolumn derivatization with 4-(2-pyridylazo)resorcinol and spectrophotometric detection at 520 nm. The concentration and separation steps are automated. The detection limit, when concentrating 200 ml of sea water, was found to be 2 ng for cadmium and 6 ng for lead. Relative standard deviations of 4.5% and 6.8% for 10 μg/1 of cadmium and lead, respectively, were obtained. Transition metals (Fe, Co, Ni, Zn, Cu, Mn) do not interfere in the analysis. An application of the method to the determination of cadmium and lead in sea-water samples collected in the Taranto gulf (Italy) is presented.  相似文献   

2.
Almendro JM  Ojeda CB  de Torres AG  Pavon JM 《Talanta》1993,40(11):1643-1648
A method is proposed for the solvent extraction of cadmium using 1,5-bis(di-2-pyridylmethylene)thiocarbohydrazide (DPTH) as extractant. The optimum extraction conditions were evaluated from a critical study of the effect of pH, concentration of extractant, shaking time and ionic strength. The maximum volume ratio of the aqueous to organic phase was 30:1 for a single-stage extraction of99-100% of the metal ion. The detection limit is 0.01 ng/ml cadmium, and the calibration is linear from 0.1 to 5 ng/ml. The relative standard deviation for 10 replicate measurements is 1.8% for 2 ng/ml cadmium. The extraction method was applied to the determination of cadmium in some biological materials using graphite furnace atomic absorption spectrometry.  相似文献   

3.
A procedure for separation and preconcentration of trace amounts of cadmium has been proposed. A column of analcime zeolite modified with benzyldimethyltetradecylammonium chloride and loaded with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) was used for retention of cadmium. The cadmium was quantitatively retained on the column at pH approximately 9 and was recovered from column with 5 ml of 2 M nitric acid with a preconcentration factor of 140. Anodic stripping differential pulse voltammetry was used for determination of cadmium. A 0.05 ng/ml detection limit for the preconcentration of aqueous solution of cadmium was obtained. The relative standard deviation (RSD) for eight replicate determinations at the 1 microg/ml cadmium levels was 0.31% (calculated with the peak height obtained). The calibration graph using the preconcentration system was linear from 0.01 to 150 microg/ml in final solution with a correlation coefficient of 0.9997. For optimization of conditions, various parameters such as the effect of pH, flow rate, instrumental conditions and interference of number of ions, were studied in detail. This method was successfully applied for determination of cadmium in various complex samples.  相似文献   

4.
A computer-controlled flow injection system was developed for the determination of cadmium in a hydrometallurgical zinc refining process stream. An anion-exchange method in acidic potassium iodide medium was used for the on-line separation of cadmium from the matrix zinc. 1-(4-Nitrophenyl)-3-(4-phenylazophenyl)triazene (Cadion) was used as the chromogenic reagent for the spectrophotometric detection of cadmium. In order to expand the dynamic range of the flow injection - spectrophotometry, a computer-aided time-based variable-volume injection method has been employed for the introduction of the sample into the flow injection system. Samples ranging from 0.56 to 350 microl can be delivered by controlling the time period of the sample introduction valve and the flow rate of the carrier solution. The system permits a throughput of 5 samples per hour. The reproducibility has been proven to be satisfactory with a relative standard deviation of less than 6.2% (sample injected: 0.56 microl of 850 microg Cd/ml; n=100) and 5.0% (350 microl of 0.14 microg Cd/ml; n=5). The determination limit was 20 microg Cd/ml with 0.56 microl sample injection and 0.05 microg Cd/ml with 350 microl sample injection (the absolute amount of cadmium injected into the system was 11 ng and 17.5 ng, respectively).  相似文献   

5.
A new method for the determination of cadmium and lead in human teeth was developed based on dispersive liquid‐liquid microextraction preconcentration and graphite furnace atomic absorption spectrometry determination. In the proposed approach, O,O‐diethyldithiophosphate (DDTP) was used as a chelating agent, and carbon tetrachloride and methanol were selected as extraction and dispersive solvents. Some factors influencing the extraction efficiency of cadmium and lead and their subsequent determination, including extraction and dispersive solvent type and volume, pH of sample solution, concentration of the chelating agent and extraction time, were studied and optimized. Under the optimum conditions, the enrichment factor of 116 and 68 for cadmium and lead were achieved. The detection limit for cadmium and lead was 5.6 and 45 ng L?1, and the relative standard deviation (R.S.D) was 4.5% and 3.8% (n = 7, c = 1.0 ng mL?1), respectively. Verification of the accuracy of the method was carried out by analysis of a standard reference material (NIST 1486, bone meal). The method was successfully applied to the determination of trace amount of cadmium and lead in human teeth samples with satisfactory results.  相似文献   

6.
Two flow injection inductively coupled plasma atomic emission spectrometric methods for the preconcentration and determination of trace amounts of cadmium in sea-water and waste-water samples are described based on the adsorption of the metal ion on a micro-column placed in the injection valve of the FI manifold and packed with silica gel funtionalised with 1,5-bis(di-2-pyridyl) methylene thiocarbohydrazide (DPTH-gel) and silica gel functionalised with methylthiosalicylate (TS-gel), respectively. Various parameters and chemical variables affecting the preconcentration and determination of this metal by ICP-AES are evaluated. The DPTH-gel preconcentration method has a linear calibration range from 5 to at least 100 ng ml(-1) of cadmium, with a R.S.D. of 1.1% for ten independent analyses of 100 ng ml(-1), a detection limit of 1.1 ng ml(-1) and a throughput of 40 samples per hour using a 60 s preconcentration time. The TS-gel preconcentration method shows a linear range between 10 and 100 ng ml(-1), with a R.S.D. of 2.5% for ten independent analyses of 100 ng ml(-1), a detection limit of 4.3 ng ml(-1) and a sample throughput of 24 samples per hour for a preconcentration time of 120 s. Validation was carried out against a certified reference water sample and by determining the analyte content in spiked synthetic sea-water, sea-water and waste-water.  相似文献   

7.
A new method for the simultaneous determination of lead, cadmium and mercury ions in microwave-digested foodstuffs by reversed-phase high-performance liquid chromatography combined with on-line enrichment technique has been developed. The foodstuff samples were digested by microwave digestion. The lead, cadmium and mercury ions can be precolumn derivatized with 5,10,15,20-tetrakis(3-aminophenyl)porphine (T3APP) to form color chelates; then, the Hg-T3APP, Cd-T3APP and Pb-T3APP chelates can be enriched and separated on a valve switching HPLC system combined with on-line enrichment technique. The linearity ranges are 0.01-120 microg/l for each metal ion. The detection limits (S/N = 3) of lead, cadmium and mercury are 1.2 ng/l, 0.5 ng/l and 0.8 ng/l, respectively. This method was applied to the determination of lead, cadmium and mercury in foodstuffs with good results.  相似文献   

8.
Robles LC  Aller AJ 《Talanta》1995,42(11):1731-1744
The retention of cadmium by the bacteria Escherichia coli and Pseudomonas putida was optimized in order to develop a rapid and selective preconcentration method for cadmium from biological and environmental samples prior to determination by electrothermal atomic absorption spectrometry. Living and lyophilized cells for both bacteria were used, but the method using dead cells shows better analytical capabilities. Cadmium from aqueous solutions is easily retained on the outer membrane of both bacteria in the pH range 4-10, although the selected working pHs for E. coli and P. putida were 5 and 9, respectively. Cadmium retained by the bacteria was dispersed in 3.5 M nitric acid and the slurry was introduced directly into the graphite tube. The best sensitivity and detection limit were obtained for E. coli (0.03 ng ml(-1) and 0.04 ng ml(-1) respectively, in the absence of any chemical modifier). A strong spectral interference from nickel chloride was found and methods to overcome it were developed. The proposed extraction procedure was tested by the determination of cadmium in different standard biological and environmental samples.  相似文献   

9.
Yebra MC  Enríquez MF  Cespón RM 《Talanta》2000,52(4):631-636
A rapid, sensitive, accurate and precise flame atomic absorption method is described for the determination of cadmium in mussels. The method is based on the continuous precipitation of cadmium as an ion pair between tetraiodocadmate and quinine and dissolution of the precipitate with ethanol. The metal can be preconcentrated 32-fold using 15 ml of sample solution by using a time-based technique at a sampling flow rate of 3.0 ml min(-1). The proposed method allows the determination of cadmium in the range 0.25-5.5 mug g(-1). The precision (relative standard deviation) obtained for different amounts of cadmium is in the range 1.5-4.7% at the 0.25-5.0 mug g(-1) level. The method demonstrates high tolerance to interferences, and the data obtained are in agreement with the certified value of a selected reference material. This procedure was applied to the determination of cadmium in mussel samples from estuaries in Galicia (Spain).  相似文献   

10.
本文报道了流动注射在线柱预富集ICP光谱测定痕量金属的方法,以meso-四(4-磺基苯)卟啉为柱前衍生试剂,硅胶作固定相和盐酸作洗脱液,对痕量金属离子Cu、Mn、Ni、Fe、Pb、Cd进行在线预富集检测。在给定实验条件下,方法的富集倍数为9.3~11.3,检出限和测定的相对标准偏差(n=6)分别在0.32~26.8ng/ml和1.3%~3.0%范围内。方法用于小牛肝和西红柿叶样品分析,结果与参考值吻合。  相似文献   

11.
A technique for determination of mercury is described; it is based on electrolytic reduction of Hg(II) ion on a graphite cathode, the trapping of mercury vapor and its volatilization into a quartz tube aligned in the optical path of an atomic absorption spectrometer. The electrochemical cell consisted of a graphite cathode and an anode operating with constant direct current for the production of mercury atoms. A pre-activated graphite rod was used as the cathode material. The optimum conditions for electrochemical generation of mercury cold vapor (the electrolysis time and current, the flow rate, the type of electrode and electrolyte) were investigated. The characteristic electrochemical data with chemical cold vapor using NaBH4-acid were compared. The presence of cadmium(II), arsenic(III), antimony(III), selenium(IV), bismuth(III), silver(I), lead(II), lithium(I), sodium(I) and potassium(I) showed interference effects which were eliminated by suitable separation techniques. The calibration curve is linear over the range of 5-90 ng ml(-1) mercury(II). The detection limit is 2 ng ml(-1) of Hg(II) and the RSD is 2.5% (n = 10) for 40 ng ml(-1). The accuracy and recovery of the method were investigated by analyzing spiked tap water and river water.  相似文献   

12.
Legotte PA  Rosa WC  Sutton DC 《Talanta》1980,27(1):39-44
A method for determining cadmium and lead in urine and other biological samples by graphite-furnace atomic-absorption spectrometry is reported. Samples were analysed after wet or dry ashing and without extraction or matrix-modification techniques, in laminar-flow clean-room; negligible blank contributions were found. Matrix interference effects were observed only for lead and were resolved by the method of standard additions. Five NBS biological reference materials were used as internal quality-control standards. The urinary levels for non-exposed volunteers ranged from 0.16 +/- 0.01 to 1.65 +/- 0.20 and from 6 +/- 1 to 31 +/- 6 ng/ml for cadmium and lead, respectively; this corresponds to 0.15 +/- 0.02 to 2.01 +/- 0.16 and 7 +/- 1 to 31 +/- 3 mug/day. The average relative standard deviation for 60 urine samples was 10% for cadmium and 13% for lead.  相似文献   

13.
A new method for direct spectrophotometric determination of cadmium with 4-(2-pyridylazo)-resorcinol is reported. Absorption maximum, molar absorptivity and Sandell's sensitivity of the 1:1 (M:L) complex are 510 nm, 2.5 x 10(5) l mol(-1) cm(-1) and 3.55 ng cm(-2), respectively. A linear calibration graph is obtained up to 4.49 microg ml(-1). The zero-crossing measurement technique is found suitable for the direct measurement of the first-derivative value at the specified wavelengths. Cadmium(II) (0.42-9.2 microg ml(-1)) and mercury(II) (0.35-7.4 microg ml(-1)) in different ratios have been determined simultaneously. A critical evaluation of the proposed method is performed by statistical analysis of the experimental data. The developed method was applied to the simultaneous spectrophotometric determination of Cd and Hg in some synthetic mixtures and was found to give satisfactory results.  相似文献   

14.
A new catalytic spectrophotometric method is reported for the simultaneous determination of nitrite and nitrate by flow injection analysis, based on the catalytic effect of nitrite on the redox reaction between pyrogallolsulfonephthalein and potassium bromate in acidic media. Nitrate can also be on-line reduced to nitrite with a modified copper-coated cadmium reduction column. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of pyrogallolsulfonephthalein at 465 nm. Various analytical parameters such as effects of acidity, reagent concentrations, flow rates, sample sizes, lengths of the reaction coil and temperatures were studied and were optimized. Under the optimized conditions, the calibration graph was linear for 2.4 to 160 ng ml(-1) of nitrite and 4.0 to 100 ng ml(-1) of nitrate. The influences of potential interfering cations and anions for nitrite and nitrate determination were studied. The method is successfully applied for food and water samples. Up to ten samples can be analyzed per hour.  相似文献   

15.
A flow injection analysis-flame atomic absorption spectrometric method for the determination of cadmium in seawater was developed with the aim of yielding a sensitive assay with a low detection limit. The method employs a field flow preconcentration technique involving a minicolumn containing Amberlite XAD-4 impregnated with the complexing agent 4-(2-pyridylazo) resorcinol. A Plackett-Burman 2(7)x3/32 design for seven factors (sample pH, sample flow rate, eluent volume, eluent concentration, eluent flow rate, ethanol percentage in the eluent and minicolumn diameter) was carried out in order to find the significant variables affecting the field continuous preconcentration system (FCPS) and the flow injection elution manifold for cadmium determination in seawater samples by flame atomic absorption spectrometry. Cadmium can be preconcentrated with an enrichment factor of 1053 for a sample volume of 200 mL and a preconcentration time of 57 min. In these experimental conditions, the method provides a linear relationship between absorbance and cadmium concentration in the range from 22-1900 ng L(-1), with a detection limit (3SD) of 6 ng L(-1). The precision (expressed as relative standard deviation) for eleven independent determinations reached values of 8.9-0.8% in cadmium solutions of 50-700 ng L(-1). Analysis of certified reference materials (SLEW-3 and NASS-5) showed good agreement with the certified value. This procedure was applied to the determination of cadmium in seawater from Galicia (Spain).  相似文献   

16.
Cadmium in polyethylene was determined by both inductively coupled plasma atomic emission spectrometry (ICP-AES) and atomic absorption spectrometry (AAS) with continuous-flow gas-phase sample introduction in a reaction medium of ascorbic acid. In the presence of mixture of cobalt and thiourea in the ascorbic acid solution, the sensitivities by both ICP-AES and AAS for cadmium were greatly enhanced. The gaseous cadmium species was phase-separated in a gas–liquid separator and directed via a stream of argon carrier gas to an inductively coupled plasma and an electrically heated quartz tube atomizer (QTA) for atomic spectrometry. Under the optimized experimental conditions, the best attainable detection limits at Cd I 228.802 nm line were 1.3 and 0.017 ng/ml with linear dynamic ranges of 10–500 ng/ml and 0.1–1 ng/ml in concentrations by ICP-AES and QTA-AAS, respectively. The instrumental precisions expressed as the relative standard deviation (R.S.D.) from ten replicate measurements of 50 and 1 ng/ml cadmium by ICP-AES and QTA-AAS were 5.6% and 3.2%, respectively. With the use of ICP-AES and QTA-AAS with gas-phase sample introduction method, six- and 200-fold improvements in detection limits for cadmium were obtained in comparison with their conventional solution nebulization methods, respectively. After the effects of several diverse elements on the determination of cadmium by ICP-AES and QTA-AAS with the present gas-phase sample introduction systems were examined, these methods were applied to the determination of low concentrations of cadmium in polyethylene. The results obtained by the present method were in good agreement with the certified values.  相似文献   

17.
In this work, a new chelating resin [1,5-bis (2-pyridyl)-3-sulphophenyl methylene] thiocarbonohydrazide immobilised on aminopropyl-controlled pore glass (550 A; PSTH-cpg) was synthesised and packed in a microcolumn which replaced the sample tip of the autosampler arm. The system was applied to the preconcentration of lead. When microliters of 10% HNO3, which acts as elution agent, pass through the microcolumn, the preconcentrated Pb(II) is eluted and directly deposited in a tungsten-rhodium coated graphite tube. With the use of the separation and preconcentration step and the permanent modifiers, the analytical characteristics of the technique were improved. The proposed method has a linear calibration range from 0.012 to 10 ng ml(-1) of lead. At a sample frequency of 36 h(-1) with a 90 s preconcentration time, the enrichment factor was 20.5, the detection and determination limits were 0.012 and 0.14 ng ml(-1), respectively and the precision, expressed as relative standard deviation, was 3.2% (at 1 ng ml(-1)). Results from the determination of Pb in biological certified reference materials were in agreement with the certified values. Seawaters and other biological samples were analysed too.  相似文献   

18.
Nagaosa Y  Yamada T 《Talanta》1984,31(5):371-374
A selective and specific method is presented for anodic-stripping voltammetric determination of cadmium after extraction with 0.1Mtetrabutylammonium iodide solution in acetonitrile from aqueous ammonium sulphate solutions. The detection limit of this method is 0.2 ng ml (in the acetonitrile extract). Interference from matrices or large amounts of elements reduced at more positive potentials can be eliminated by prior extraction. The method has been applied to trace analysis for cadmium in zinc, lead and indium metals, and some inorganic salts.  相似文献   

19.
An automated solvent extraction method for determination of lead and cadmium down to the 50 ng/ml level has been developed. Optimum conditions for selective and sensitive determination were designed and verified by using the flow-injection scanning method.  相似文献   

20.
An intermittent on-line concentration and separation system coupled with HG-AFS was developed to eliminate serious interferences from Cu2+, Pb2+ and Zn2+ on the determination of cadmium. In the present method, the interferences from common coexisting ions, such as Cu2+, Pb2+, Zn2+, Fe3+ and Ni2+, were greatly reduced. Under the optimized conditions, a detection limit of 3 pg ml(-1) (3sigma, n=11) and a precision of 1.9% RSD for 1 ng ml(-1) of Cd were obtained. The method was successfully applied to the determination of cadmium in a series of Chinese Geological Reference Materials (SRMs) and GBW01621 ferronickel alloy using simple aqueous standard calibration technique. The results obtained were in good agreement with the certified values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号