首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
NaA zeolite membranes were synthesized on an asymmetric porous alumina support with a lower mass-flow resistance for development of more economically feasible membranes with higher permeation performance. The support influence on permeation fluxes through the membrane using asymmetric support was investigated by vapor permeation at 100–145 °C in a mixture of water (10 wt.%)/ethanol (90 wt.%) in which the higher permeation fluxes up to 37 kg m−2 h−1 or water permeances up to 3.2 × 10−6 mol m−2 s−1 Pa−1at 145 °C were observed. The performance was higher than those in the previously reported NaA membrane on a monolayer porous alumina support of 31 kg m−2 h−1 or water permeances of 2.5 × 10−6 mol m−2 s−1 Pa−1at 145 °C. These results are experimental evidence to show the effect of asymmetric support utilization in membrane preparation on the higher membrane performance. The estimate of the pressure drop over the both types of support indicates that the improvement of higher permeation fluxes in the asymmetric type membrane could be attributed to the suppression of pressure drop in the support layer due to lower mass-flow resistance there.  相似文献   

2.
Polyelectrolytes were incorporated into porous reinforcing materials to study the properties of ionomers in confined spaces and to determine the effect of the porous material on the behaviour of the membranes. Nafion® was imbibed into porous polypropylene (Celgard®), ultra-high-molecular weight polyethylene (Daramic®), and polytetrafluoroethylene (PTFE) films. Through the use of reinforcing materials, it is possible to prepare membranes that are thinner, but stronger than pure ionomer membranes. Thin reinforced membranes have advantages such as lower areal resistance (as low as 0.14 Ω cm2 for 57 μm CG3501 + Nafion® compared to 0.34 Ω cm2 for 89 μm cast Nafion®) and lower dimensional changes due to swelling (as low as a 4% change in length and width for WDM + Nafion® compared to 13% for cast Nafion®). Using reinforcing materials results in a reduction in important membrane properties compared to bulk Nafion®, such as proton conductivity (as low as 0.016 S cm−1 for CG3401 + Nafion® compared to 0.076 S cm−1 for cast Nafion®), effective proton mobility (as low as 3.2 × 10−4 cm2 V−1 s−1 CG3401 + Nafion® compared to 7.6 × 10−4 cm2 V−1 s−1 for cast Nafion®), and water vapour permeance (as low as 0.036 g h−1 Pa−1 m−2 for WDM + Nafion® compared to 0.056 g h−1 Pa−1 m−2 for cast Nafion®). By normalizing the membrane properties with respect to ionomer content, it was possible to examine the properties of the Nafion® inside the pores of the membranes. The proton conductivity (as low as 0.032 S cm−1 for CG3401 + Nafion®), effective proton mobility (as low as 3.6 × 10−4 cm2 V−1 s−1 for CG3401 + Nafion®), and water vapour permeability (as low as 2.7 × 10−6 g h−1 Pa−1 m−1 for PTFE MP 0.1 + Nafion®) of the ionomer in the membrane are also diminished compared to bulk Nafion® due to decreased connectivity of the ionomer and a restriction in macromolecular motions caused by the pore walls. A series of porous materials with increasing pore were also examined. As the pore size of the PTFE MP materials increased from 0.1 μm to 10 μm, the proton conductivity (0.022 S cm−1 to 0.041 S cm−1), effective proton mobility ((4.1 to 5.6) × 10−4 cm2 V−1 s−1), and water vapour permeability ((2.4 to 4.3) × 10−6 g h−1 Pa−1 m−1) of the reinforced membranes improved with increasing pore size and the properties of the ionomer inside the membranes approached the value of bulk Nafion®.  相似文献   

3.
A TiO2 membrane supported on a planar porous Ti–Al alloy was prepared by combination of electrophoretic deposition and dip-coating. In the electrophoretic deposition process, the membrane thickness increased linearly with the square root of the deposition time, while increased with decrease of the suspension viscosity. The perfect TiO2/Ti–Al composite membrane was obtained by further dip-coating modification. SEM images showed that the surface of the membrane was defect-free. XRD result indicated that rutile TiO2 still remained in the membrane bulk as the main phase, while a new phase titanium oxides with the form of TixOy, where y is less than 2x, was also observed. The supported TiO2/Ti–Al composite membrane had an average pore size of 0.28 μm, a thickness of 40 μm or so and a pure water flux of 3037 L m−2 h−1 bar−1.  相似文献   

4.
This paper investigates the microfiltration of skim milk in order to separate caseins micelles from two whey proteins, α-lactalbumin (α-La) and β-lactoglobulin (β-Lg), using a modified dynamic filtration pilot (MSD) consisting in 6 ceramic 9-cm diameter membrane disks of 0.2 μm pores, rotating around a shaft inside cylindrical housing. A comparison was made with another dynamic filtration module consisting in a disk rotating near a fixed PVDF 15.5 cm diameter membrane with 0.15 μm pores. Maximum permeate fluxes were 120 L h−1 m−2 with the MSD module at 1930 rpm and at 40 °C, and 210 L h−1 m−2 at 2500 rpm and 45 °C, with the rotating disk module. Casein rejection was around 99% at high speed for both membranes. α-La transmission decreased with increasing transmembrane pressure (TMP) from 75% to 60% for ceramic membranes and from 25% to 10% for the PVDF one. β-Lg transmissions were lower, ranging from 23% to 15% for ceramic membranes and from 20% to 5% for the PVDF one. In a concentration test with the PVDF membrane at 2000 rpm, the flux decayed from 200 L h−1 m−2 at initial concentration to 80 L h−1 m−2 at VRR = 3.2 and 22.1% of the initial α-La mass was recovered in the permeate, against 8.1% for β-Lg. Permeate fluxes in the mass transfer limited regime (Jlim) of the MSD and rotating disk module operated at various speeds were well correlated by the equation Jlim = 17.13 Vav where Vav denoted the disk azimuthal velocity averaged over the membrane area. Measurements of Jlim, taken from Ref. [G. Samuelsson, P. Dejlmek, G. Tragardh, M. Paulsson, Minimizing whey protein retention in crossflow microfiltration of skim milk. Int. Dairy J. 7 (1997) 237–242] during MF of skim milk using tubular ceramic membranes at velocities from 1.5 to 8 m s−1 with permeate co-current recirculation were found to obey the same correlation.  相似文献   

5.
The composite tubular membranes were prepared by applying suspensions of zirconia particles to form separation top-layers on two different porous α-alumina supports and heating the coated supports to partly sinter the particles of top-layers. The conditions of synthesizing the ZrO2/α-Al2O3 membranes were investigated systematically. The mean pore diameter of zirconia membrane was about 0.2 μm by gas bubble pressure method, and the pure water flux was about 400 and 1500 l/(m2 h bar) for ZrO2 membrane on symmetric and asymmetric Al2O3 support, respectively. Zirconia membrane and three different alumina membranes were applied to separate oil–water emulsion obtained from steelworks to evaluate the permeability and separation characteristics, the ZrO2/α-Al2O3 MF membrane in this work was the preferred membrane.  相似文献   

6.
We present a new processing scheme for the deposition of microporous, sol–gel derived silica membranes on inexpensive, commercially available anodic alumina (Anodisk™) supports. In a first step, a surfactant-templated mesoporous silica sublayer (pore size 2–6 nm) is deposited on the Anodisk support by dip-coating, in order to provide a smooth transition from the pore size of the support (20 or 100 nm) to that of the membrane (3–4 Å). Subsequently, the microporous gas separation membrane layer is deposited by spin-coating, resulting in a defect-free dual-layer micro-/mesoporous silica membrane exhibiting high permeance and high selectivity for size selective gas separations. For example, in the case of CO2:N2 separation, the CO2 permeance reached 3.0 MPU (1 MPU = 10−7 mol m−2 s−1 Pa−1) coupled with a CO2:N2 separation factor in excess of 80 at 25 °C. This processing scheme can be utilized for laboratory-scale development of other types of microporous or dense inorganic membranes, taking advantage of the availability, low cost and low permeation resistance of anodic alumina (or other metal oxide) meso- and macroporous supports.  相似文献   

7.
We report a new device for the estimation of the content of chlorophyll a pigment in water samples as an indicator of water quality. The extraction of the pigment from water was also optimized. 10 mL of water was filtered through a nylon filter (45 μm pore size and 13 mm of diameter), after the chlorophylls were dissolved by immersing the filter in 1 mL of a low non-hazardous solvent as ethanol. An in-valve in-tube SPME device coupled to capillary liquid chromatography with diode array detection was designed. A capillary column of 70 cm in length (0.32 mm i.d. coated with 5% diphenyl-95% polydimethylsiloxane, 3 μm coating thickness) was used as the loop of the injection valve for preconcentration and a Zorbax SB C18 (SiO2-based) 150 mm × 0.5 mm i.d., 5 μm column (Agilent) was used as analytical column. The achieved detection limit was 0.05 μg L−1 and the working range of concentrations was 0.1-1 μg L−1. % RSD values between 2 and 11 were obtained. Chlorophyll a in several water matrices was determined with good results in presence of other pigments such as chlorophyll b, pheophytin a and pheophytin b.  相似文献   

8.
The bisphenol A (BPA) imprinted polymer microspheres were prepared by simple Pickering emulsion polymerization. Compared to traditional bulk polymerization, both high yields of polymer and good control of particle sizes were achieved. The characterization results of scanning electron microscopy and nitrogen adsorption–desorption measurements showed that the obtained molecularly imprinted polymer microsphere (MIPMS) particles possessed regular spherical shape, narrow diameter distribution (30–60 μm), a specific surface area (SBET) of 281.26 m2 g−1 and a total pore volume (Vt) of 0.459 cm3 g−1. Good specific adsorption capacity for BPA was obtained in the sorption experiment and good class selectivity for BPA and its seven structural analogs (bisphenol F, bisphenol B, bisphenol E, bisphenol AF, bisphenol S, bisphenol AP and bisphenol Z) was demonstrated by the chromatographic evaluation experiment. The MIPMS as solid-phase extraction (SPE) packing material was then evaluated for extraction and clean-up of these bisphenols (BPs) from human urine samples. An accurate and sensitive analytical method based on the MIPMS-SPE coupled with HPLC-DAD has been successfully established for simultaneous determination of eight BPs from human urine samples with detection limits of 1.2–2.2 ng mL−1. The recoveries of BPs for urine samples at two spiking levels (100 and 500 ng mL−1 for each BP) were in the range of 81.3–106.7% with RSD values below 8.3%.  相似文献   

9.
Facilitated transport of Am(III) in nitric acid medium using tetra(2-ethyl hexyl) diglycolamide (TEHDGA) in n-dodecane as carrier was studied. It was aimed at finding out the physico-chemical model for the transport of Am(III) using TEHDGA/n-dodecane as carrier under various experimental parameters like feed acidity, carrier concentration, varying strippant, varying membrane pore size, etc. The feed acidity and carrier concentrations were varied from 1 M to 6 M HNO3 and 0.1 M to 0.3 M TEHDGA/n-dodecane, respectively. The transport of Am(III) increased with increase in feed acidity and carrier concentration reaching maximum at 3 M HNO3 and 0.2 M TEHDGA/n-dodecane, respectively. Several stripping agents were tested and 0.1 M HNO3 was found to be the most suitable stripping agent for this system. Almost quantitative transport of Am(III) was observed at about 180 min with feed acidity of 3 M HNO3, 0.1 M HNO3 as strippant and 0.2 M TEHDGA/n-dodecane as carrier. The pore size of the membrane support was varied from 0.20 μm to 5 μm and the permeation coefficient increased with increase in pore size up to 0.45 μm (2.43 × 10−3 cm/s), and then decreased with further increase in pore size. The plot between permeation coefficient vs. (membrane thickness)−1 was linear which showed that the Am(III) transport was membrane diffusion limited. The membrane diffusion coefficient calculated from the graph was found to be 1.27 × 10−6 cm2/s and its theoretical value was 1.22 × 10−6 cm2/s. The stability of the carrier against leaching out of the membrane support as well as the integrity of membrane support was studied over a period of 30 days and was found to be satisfactory within the studied time period.  相似文献   

10.
A method based on solid-phase microextraction (SPME) and gas chromatography with mass spectrometry (GC/MS) for the determination of 18 organophosphorus pesticides (OPPs) in textiles is described. Commercially available SPME fibers, 100 μm PDMS and 85 μm PA, were compared and 85 μm PA exhibited better performance to the OPPs. Various parameters affecting SPME, including extraction and desorption time, extraction temperature, salinity and pH, were studied. The optimized conditions were: 35 min extraction at 25 °C, 5% NaSO4 content, pH 7.0, and 3.5 min desorption in GC injector port at 250 °C. The linear ranges of the SPME-GC/MS method were 0.1-500 μg L−1 for most of the OPPs. The limits of detection (LODs) ranged from 0.01 μg L−1 (for bromophos-ethyl) to 55 μg L−1 (for azinphos-methyl) and the RSDs were between 0.66% and 9.22%. The optimized method was then used to analyze 18 OPPs in textile sample, and the determined recoveries were ranged from 76.7% to 126.8%. Moreover, the distribution coefficients of the OPPs between 85 μm PA fiber and simulative sweat solution (Kpa/s) were determined. The determined Kpa/s of the OPPs correlated well with their octanol-water partition coefficients (r = 0.764 and 0.678) and water solubility (= −0.892 and −0.863).  相似文献   

11.
Two kinds of mesoporous cellular foams (MCFs), including mesoporous silica materials (MCF-1) and phenyl modified mesoporous materials (Ph-MCF-1), were synthesized and for the first time used as fiber-coating materials for solid-phase microextraction (SPME). By using stainless steel wire as the supporting core, four types of fibers were prepared by sol–gel method and immobilized by epoxy-resin method. To evaluate the performance of the home-made fibers for SPME, seven brominated flame retardants (BFRs), including tetrabromobisphenol A (TBBPA), tetrabromobisphenol S (TBBPS) and related compounds were selected as analytes. The main parameters that affect the extraction and desorption efficiencies, such as extraction temperature, extraction time, desorption time, stirring rate and ionic strength of samples were investigated and optimized. The optimized SPME coupled with high performance liquid chromatography (HPLC) was successfully applied to the determination of the seven BFRs in water samples. The linearity range was from 5.0 to 1000 μg L−1 for each compound except TBBPS (from 1.0 to 1000 μg L−1), with the correlation coefficients (r2) ranging from 0.9993 to 0.9999. The limits of detection of the method were 0.4–0.9 μg L−1. The relative standard deviations varied from 1.2 to 5.1% (n = 5). The repeatability of fiber-to-fiber and batch-to-batch was 2.5–6.5% and 3.2–6.7%. The recoveries of the BFRs from aqueous samples were in the range between 86.5 and 103.6%. Compared with three commercial fibers (100 μm PDMS, 85 μm PA and 65 μm PDMS/DVB), the MCFs-coated fiber showed about 3.5-fold higher extraction efficiency.  相似文献   

12.
A diuretic is a substance widely prohibited in competition sports, by the World Anti-Doping Agency (WADA). In this paper, a sensitive, rapid and convenient analytical solid phase extraction-fluorimetric method for the determination of furosemide (FUR) and amiloride hydrochloride (AMI) diuretics in human urine was developed. FUR and AMI exhibit overlapped fluorescent spectra and urine produces background fluorescence that precludes the direct determination of these diuretics by conventional fluorimetry. AMI was adsorbed using nylon membranes whereas; FUR was detected in aqueous solutions. The optimum analytical conditions for AMI and FUR assay were established. Excitation wavelengths of 365 nm and 237 nm and emission wavelengths of 406 and 415 nm were used for AMI and FUR, respectively. The calibration graphs are linear in the range of 3.7 × 10−4 to 0.8 μg mL− 1 and 1.2 × 10− 3 to 4.0 μg mL− 1, for AMI and FUR, respectively, with a detection limit of 1.1 × 10− 4 and 3.5 × 10− 4 μg mL− 1 (S/N = 3). These concentrations correspond well with the range of the drugs in urine. AMI and FUR were accurately quantified in doped urine samples and urine of subjects under medical treatment with diuretic. The results were validated by recovery test, being highly satisfactory.  相似文献   

13.
In the present work, a rapid and sensitive method for simultaneous determination of penicillin G (PG), benzathine (BE) and procaine (PR) in drug and serum media is introduced. The polar hydro-organic (55/45) mobile phases containing an aqueous solution adjusted to pH = 3.7 and an organic solvent (MeOH) including triethylamine (TEA) and trifluroacetic acid (TFA) are used. The flow rate of 1 ml min−1, a C8 column (150 mm × 46 mm) with 5 μm i.d. and wavelength at 215 nm are selected for optimal separation condition. The limit of detection (LOD), linear concentration range and relative standard deviation (R.S.D.) of this method for the PG are 1.1 μg ml−1, 10-2400 μg ml−1 and 1.7% and for the BE are 1.2 μg ml−1, 12-2100 μg ml−1 and 1.8% and for the PR are 1.5 μg ml−1, 20-2000 μg ml−1 and 2%, respectively. The factorial design is used for the determination of main and interaction effects of pH, flow rate and concentration of MeOH, TEA and TFA in the separation at two levels. Also, the analysis of variance (ANOVA) table is obtained. The results show that TFA and TEA have higher effect than concentration of MeOH, pH and flow rate factors.  相似文献   

14.
A procedure involving the simultaneous performance of liquid–liquid microextraction and polypropylene microporous membrane solid-phase extraction was carried out. The applicability of the proposed procedure was evaluated through extraction of several organochlorine pesticides from river water, tomato and strawberry samples. The parameters affecting the extraction efficiency were optimized by multivariable designs, and the analytical features were estimated. Under optimized conditions, analytes were concentrated onto 1.5 cm long microporous membranes placed directly into the sample containing 15 mL of water with 20 μL of 1-octanol. The best extraction conditions were achieved at 59 °C, with 60 min of extraction time and 2.91 g of sodium chloride. The desorption of the analytes was carried out using 30 μL of a mixture of toluene and hexane in the proportion of 60:40% (v/v) for 10 min. Detection limits in the range of 2.7–20.0 ng L−1, 0.50–1.15 μg kg−1, and 1.53–12.77 μg kg−1 were obtained for river water, strawberry and tomato samples, respectively. Good repeatability was obtained for all three sample types. The results suggest that the proposed procedure represents a very simple and low-cost microextraction alternative rendering adequate limits of quantification for the determination of organochlorine pesticides in environmental and food samples.  相似文献   

15.
Safavi A  Maleki N  Shahbaazi HR 《Talanta》2006,68(4):1113-1119
A sensitive method for the determination of chromium ion(VI) in complex matrices such as crude oil and sludge is presented based on the decreasing effect of Cr(VI) on cathodic adsorptive stripping peak height of Cu-adenine complex. Under the optimum experimental conditions (pH 7.5 Britton-Robinson buffer, 5 × 10−5 M copper, 8 × 10−6 M adenine and accumulation potential −250 mV versus Ag/AgCl), a linear decrease of the peak current of Cu-adenine was observed, when the chromium(VI) concentration was increased from 5 μg L−1 to 120 μg L−1. Detection limit of 2 μg L−1 was achieved for 120 s accumulation time. The relative standard deviations (R.S.D., %) were 1.8% and 4% for chromium(VI) concentrations of 18 μg L−1 and 100 μg L−1, respectively. The method was applied to the determination of chromium(VI) in the presence of high levels of chromium(III), in various real samples such as crude oil, crude oil tank button sludge, waste water and tap water samples. Effects of foreign ions and surfactants on the voltammetric peak and the influences of instrumental and analytical parameters were investigated in detail. The accuracy of the results was checked by ICP and/or AA.  相似文献   

16.
《Analytica chimica acta》2003,476(1):141-148
A flow injection (FI) system combined with two photochemical processes is developed for the sensitive and rapid determination of carbaryl. It is based on the on-line photo-conversion of carbaryl into methylamine which subsequently reacts with Ru(bpy)33+ generated through the on-line photo-oxidation of Ru(bpy)32+ with peroxydisulphate. The linear concentration range of application was 0.04-4.0 μg ml−1 of carbaryl, with an R.S.D. of 1.2% (for a level of 0.50 μg ml−1) and a detection limit of 0.012 μg ml−1. The sample throughput was 200 injections per hour. The applicability of the method was demonstrated by determining carbaryl in commercial formulations, water, soil, grain and blood serum.  相似文献   

17.
For the isocratic ion chromatography (IC) separation of low-molecular-mass organic acids and inorganic anions three different anion-exchange columns were studied: IonPac AS14 (9 μm particle size), Allsep A-2 (7 μm particle size), and IC SI-50 4E (5 μm particle size). A complete baseline separation for all analyzed anions (i.e., F, acetate, formate, Cl, NO2, Br, NO3, HPO42− and SO42−) in one analytical cycle of shorter than 17 min was achieved on the IC SI-50 4E column, using an eluent mixture of 3.2 mM Na2CO3 and 1.0 mM NaHCO3 with a flow rate of 1.0 mL min−1. On the IonPac AS14 column, it was possible to separate acetate from inorganic anions in one run (i.e., less than 9 min), but not formate, under the following conditions: 3.5 mM Na2CO3 plus 1.0 mM NaHCO3 with a flow rate of 1.2 mL min−1. Therefore, it was necessary to adapt a second run with a 2.0 mM Na2B4O7 solution as an eluent under a flow rate of 0.8 mL min−1 for the separation of organic ions, which considerably enlarged the analysis time. For the Allsep A-2 column, using an eluent mixture of 1.2 mM Na2CO3 plus 1.5 mM NaHCO3 with a flow rate of 1.6 mL min−1, it was possible to separate almost all anions in one run within 25 min, except the fluoride-acetate critical pair. A Certified Multianion Standard Solution PRIMUS for IC was used for the validation of the analytical methods. The lowest RSDs (less than 1%) and the best LODs (0.02, 0.2, 0.16, 0.11, 0.06, 0.05, 0.04, 0.14 and 0.09 mg L−1 for F, Ac, For, Cl, NO2, Br, NO3, HPO42− and SO42−, respectively) were achieved using the IC SI-50 4E column. This column was applied for the separation of concerned ions in environmental precipitation samples such as snow, hail and rainwater.  相似文献   

18.
Capillary zone electrophoresis (CZE) with UV detection was used to determine vanadium species. Nitrilotriacetic acid (NTA), hydroxyethylethylenediaminetriacetic acid (HEDTA), ethylenediaminetetraacetic acid (EDTA), diethylenetriaminepentaacetic acid (DTPA), ethylene glycol-bis(2-aminoethylether)-tetraacetic acid (EGTA) and 2,6-pyridinedicarboxylic acid (PDCA) were investigated to determine whether these ligands formed stable anionic complexes with vanadium. Of all the ligands studied HEDTA was the most suitable ligand because it gave the largest UV response with reasonable migration time. Electrospray mass spectrometry (ES-MS) was used to confirm the formation of [VO2(HEDTA)]2− and [VO(HEDTA)]1− in solution. An electrolyte containing 25 mM phosphate, 0.25 mM tetradecyltrimethylammonium bromide (TTAB) at pH 5.5 was optimum for the separation of these anionic vanadium complexes. Sample stacking techniques, including large-volume sample stacking (LVSS) and field-amplified sample injection (FASI), were tested to improve the sensitivity. Best sensitivity was obtained using FASI, with detection limits of 0.001 μM, equivalent to 0.4 μg L−1, for [VO2(HEDTA)]2− and 0.01 μM, equivalent to 3.4 μg L−1 for [VO(HEDTA)]1−. The utility of the method for the speciation of V(IV) and V(V) was demonstrated using ground water samples.  相似文献   

19.
Competitive electrochemical enzyme-linked immunosorbent assays based on disposable screen-printed electrodes have been developed for quantitative determination of ochratoxin A (OTA). The assays were carried out using monoclonal antibodies in the direct and indirect format. OTA working range, I50 and detection limits were 0.05-2.5 and 0.1-7.5 μg L−1, 0.35 (±0.04) μg L−1 and 0.9 (±0.1) μg L−1, 60 and 100 μg L−1 in the direct and indirect assay format, respectively. The immunosensor in the direct format was selected for the determination of OTA in wheat. Samples were extracted with aqueous acetonitrile and the extract analyzed directly by the assay without clean-up. The I50 in real samples was 0.2 μg L−1 corresponding to 1.6 μg/kg in the wheat sample with a detection limit of 0.4 μg/kg (calculated as blank signal −3σ). Within- and between-assay variability were less than 5 and 10%, respectively. A good correlation (r = 0.9992) was found by comparative analysis of naturally contaminated wheat samples using this assay and an HPLC/immunoaffinity clean-up method based on the AOAC Official Method 2000.03 for the determination of OTA in barley.  相似文献   

20.
通过浸渍3-氨丙基甲基二乙氧基硅烷(ADMS)对α-Al2O3中空纤维载体进行有机功能化改性, 使载体表面带正电, 利用NaA分子筛晶种负电性与功能化载体之间的静电吸附机理进行预涂晶种, 采用微波加热-二次生长法于载体表面合成了NaA分子筛膜. 采用X射线衍射(XRD)、zeta 电位、扫描电子显微镜(SEM)等分析手段和气体渗透实验对NaA分子筛膜进行了表征. 考察了未改性NaA分子筛膜与改性NaA分子筛膜的形貌、结构和气体渗透性能差异. XRD结果表明载体表面只有NaA分子筛生成; zeta 电位分析表明NaA分子筛晶种及分子筛前驱体与有机功能化载体电位相反, 存在静电吸附作用; SEM结果显示改性NaA分子筛膜表面颗粒相互联结呈孪生态, 膜厚约5 μm, 膜层致密、均匀、平整; 在不同温度下对H2、O2、N2和C3H8进行气体渗透测试,35 °C条件下改性NaA分子筛膜对H2的渗透率仅为3.6×10-7 mol·m-2·s-1·Pa-1, 较未改性NaA分子筛膜的渗透率(4.0×10-7 mol·m-2·s-1·Pa-1)低, 而改性NaA分子筛膜的H2/C3H8理想分离系数则高达11.25, 远大于未改性NaA分子筛膜的H2/C3H8理想分离系数(5.06).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号